• Title/Summary/Keyword: Instrument Accuracy

Search Result 336, Processing Time 0.024 seconds

STATUS AND PROGRESS OF ARGO-M SYSTEM DEVELOPMENT (인공위성 레이저추적 시스템(ARGO-M) 개발 현황)

  • Park, Eun-Seo;Yu, S.Y.;Lim, H.C.;Bang, S.C.;Seo, Y.K.;Park, J.H.;Jo, J.H.;Park, J.U.;Nah, J.K.;Jang, J.G.;Jang, B.H.;Kim, K.D.;Kim, B.I.;Park, C.H.;Lee, S.H.;Ham, S.Y.;Son, Y.S.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.3
    • /
    • pp.49-59
    • /
    • 2012
  • KASI (Korea Astronomy and Space Science Institute) has developed an SLR (Satellite Laser Ranging) system since 2008. The name of the development program is ARGO (Accurate Ranging system for Geodetic Observation). ARGO has a wide range of applications in the satellite precise orbit determination and space geodesy research using SLR with mm-level accuracy. ARGO-M (Mobile, bistatic 10 cm transmitting/40 cm receiving telescopes) and ARGO-F (Fixed stationary, about 1 m transmitting/receiving integrated telescope) SLR systems development will be completed by 2014. In 2011, ARGO-M system integration was completed. At present ARGO-M is in the course of system calibration, functionality, and performance tests. It consists of six subsystems, OPS (Optics System), TMS (Tracking Mount System), OES (Opto-Electronic System), CDS (Container-Dome System), LAS (Laser System) and AOS (ARGO Operation System). In this paper, ARGO-M system structure and integration status are introduced and described.

Sensitivity Analysis and Estimation of the Depth of Investigation in Small-Loop EM Surveys (소형루프 전자탐사의 감도분석 및 가탐심도 추정)

  • Song Yoonho;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.299-308
    • /
    • 2002
  • We have derived an analytical expression for the sensitivity of the frequency domain small-loop electromagnetic (EM) surveys over a two-layer earth in order to estimate the depth of investigation with an instrument having the source-receiver separation of about 2 m. We analyzed the sensitivities to the lower layer normalized by those to the upper half-space and estimated the depth of investigation from the sensitivity analyses and the mutual impedance ratio. The computational results showed that the in-phase components of the sensitivity to the lower layer dominates those to the upper layer when the thickness of the upper layer is less than 20 m, while the quadrature components are not sensitive to the lower layer over the entire frequency range. Hence we confirmed that the accurate measurement of the in-phase component is essential to increase the depth of investigation in the multi-frequency small-loop EM survey. When conductive basement of 10 ohm-m underlies the upper layer of 100 ohm-m, an accurate measurement of the in-phase components ensures the depth of the investigation more than 10 m even accounting a noise effect, from which we conclude that the small-loop EM survey is quite effective in imaging the conductive plume down to a considerable depth. On the other hand, in the presence of the resistive basement of 1,000 ohm-m, the depth of investigation may not exceed 5 m considering the instrumental accuracy, which implies that the application of the small-loop EM survey is not recommended over the resistive environment other than detecting the buried conductor.

Development of HPLC-UV method for detection and quantification of seven organic acids in animal feed (사료 중 유기산 7종 동시분석법 개발 및 유통 사료의 모니터링)

  • Kim, Jin kug;Lee, Mi Jin;Lee, Ye Ji;Kim, Hye Jin;Jeong, Min Hee;Kim, Ho Jin
    • Analytical Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.202-208
    • /
    • 2016
  • 본 연구에서는 사료 첨가제로 이용되고 있는 유기산 7종(formic acid, malic acid, lactic acid, acetic acid, citric acid, fumaric acid, propionic acid)의 동시분석법 개발을 위한 연구를 실시하였다. 7종의 화합물은 표준물질의 Retention time과 UV spectra를 통해 구별하였고, 분석법 검증은 직선성, 민감성, 선택성, 정확성, 정밀성을 통하여 검증하였다. 그 결과로 LOD와 LOQ의 범위가 각각 43~26,755 μg/kg, 12-8,026 μg/kg으로 설정하였고, 평균 회수율이 79.3~95.2%로 우수하게 보였으며, intra-day, inter-day에 대한 전반적인 상대 표준 편차(%RSD)는 3.2% 미만으로 나타났다. 이와 같이 검증된 자료를 통해 유기산의 동시분석에 대한 직선성, 민감성, 선택성, 정확성 및 정밀성을 확인하였고, 높은 수준을 나타냄을 알 수 있었다. 이를 바탕으로 유기산이 검출되는 단미사료 46 가지를 분석에 적용하여 진행하였고, 정량과 동시분석 검출을 위한 방법은 RP-HPLC/UV 검출기를 이용하여 성공적으로 개발되었다. 따라서 본 연구결과를 바탕으로 하여 사료 중의 유기산의 분석이 신속하고 정확해졌을 뿐 아니라, 다른 종류의 사료 또한 이를 적용하여 효율적으로 이용할 수 있을 것으로 판단된다.

Guidelines for Free-Hand Aspiration(FHA) of Putaminal Hemorrhage (피각부 자발성 뇌내출혈의 혈종흡입술을 위한 지표)

  • Yim, Sin Gil;Oh, Min Suk;Lim, Jun Seob;Kang, Myung Gi;Kwak, Yeon Sang;Park, Seung Gyu;Song, Gyung Bae;Kim, Han Yung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.294-299
    • /
    • 2001
  • Objectives : CT-guided stereotactic evacuation for spontaneous intracerebral hemorrhage can minimize the brain damage and can be performed safely and simply under local anesthesia. But that procedure is time consuming and has a risk of rebleeding because of the stress during head pin fixation. So authors describe easy and precise guidelines for FHA of putaminal hemorrhage without stereotactic instrument. Methods and Materials : We analyzed the data of 298 patients who underwent CT-guided stereotactic aspiration of putaminal hematoma in our hospital between January 1990 and December 2000. We divided the patients into three groups according to the location of hematoma : anterior portion, middle portion and posterior portion of putamen. Total number of catheters inserted into the hematoma were 345 and there were with regard to the direction and depth of catheters. Results : Proposed guidelines of catheter insertion to putaminal hemorrhage in our institution. 1) hematoma at the anterior portion of putamen ; Direction of catheter was the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between external auditory meatus(EOM) and 1cm posterior to EOM. Depth of catheter was 6-6.5cm. 2) hematoma at the middle portion of putamen ; Direction of catheter was the midpupillary line of the the eye and the point intersecting a line drawn from the burr hole to a point between 1cm and 2cm posterior to EOM. Depth of catheter was 6.5-7cm. 3) hematoma at the posterior portion of putamen ; Direction of catheter was 15 degree laterally from the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between 2cm and 3cm posterior to EOM. Depth of catheter was 7-7.5cm. We have performed FHA of putaminal hemorrhage in 48 cases according to this guideline. All catheter were inserted exactly at the center of hematoma and average operation time was about 30 minutes. Conclusion : Our proposed guidelines for putaminal hemorrhage are considered to be safe and simple method with similar accuracy and rapid decompression compared with traditional stereotactic method. Main advantages of this technique were unnecessity of stereotactic frame application and less time requirement for hematoma removal.

  • PDF

Fabrication and Evaluation of Diameter 1 m Off-axis Parabolic mirror (직경 1 m 비축포물면의 가공 및 평가)

  • Yang, Ho-Soon;Lee, Jae-Hyeob;Jeon, Byung-Hyug;Lee, Yun-Woo;Lee, Kyoung-Muk;Choi, Se-Chol;Kim, Jong-Min
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.4
    • /
    • pp.287-293
    • /
    • 2008
  • The collimator which makes a collimated beam, is an essential instrument for assembly and evaluation of telescopes. Recently, the Cassegrain type collimator has been widely used for its compact size as the focal length of high resolution cameras becomes longer. However, this kind of collimator has a disadvantage in that the secondary mirror is a heat source which can degrade the evaluation accuracy for an IR camera system. In this paper, we present the fabrication and measurement process for an off-axis parabolic mirror with the physical diameter pf 1 m, effective diameter 930 mm, and the focal length 6 m. After four months of works we obtained the final surface wave-front error of 30.4 nm rms ($\lambda$/138, ${\lambda}=4.2\;{\mu}m$), which is capable of evaluation of an IR camera as well as a visible camera.

Measurement and analysis of PM10 and PM2.5 from chimneys of coal-fired power plants using a light scattering method (광산란법을 이용한 국내 석탄화력발전소 굴뚝에서 배출되는 PM10, PM2.5 측정 및 분석)

  • Shin, Dongho;Kim, Younghun;Hong, Kee-Jung;Lee, Gunhee;Park, Inyong;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.16 no.4
    • /
    • pp.131-140
    • /
    • 2020
  • Air pollutants emitted from chimneys of coal-fired power plants are considered to be a major source of fine particulate matter in the atmosphere. In order to manage fine particle in the chimney of a coal-fired power plant, it is necessary to know the concentration of fine particle emitted in real time, but the current system is difficult. In this study, a real-time measurement system for chimney fine particle was developed, and measurements were performed on six coal-fired power plants. Through the measurements, the mass concentration distribution according to the particle size could be secured. All six chimneys showed bimodal distribution, and the count median diameters of each mode were 0.5 and 1.1 ㎛. In addition, it was compared with the gravimetric measurement method, and it was determined that the relative accuracy for PM10 was within 20%, and the value measured using the developed measuring instrument was reliable. Finally, three power plants were continuously measured for one month, and as a result of comparing the concentration of PM10 according to the amount of power generation, it was confirmed that the PM10 discharged from the chimney increased in the form of an exponential function according to the amount of power generation.

Improved Ship and Wake Detection Using Sentinel-2A Satellite Data (Sentinel-2A 위성자료를 활용한 선박 및 후류 탐지 개선)

  • Jeon, Uujin;Seo, Minji;Seong, Noh-hun;Choi, Sungwon;Sim, Suyoung;Byeon, Yugyeong;Han, Kyung-soo
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.3
    • /
    • pp.559-566
    • /
    • 2021
  • It is necessary to quickly detect and respond to ship accidents that occur continuously due to the influence of the recently increased maritime traffic. For this purpose, ship detection research is being actively conducted based on satellite images that can be monitored in real time over a wide area. However, there is a possibility that the wake may be falsely detected as a ship because the wake removal is not performed in previous studies that performed ship detection using spectral characteristics. Therefore, in this study, ship detection was performed using SDI (Ship Detection Index) based on the Sentinel-2A satellite image, and the wake was removed by utilizing the difference in the spectral characteristics of the ship and the wake. Probability of detection (POD) and false alarm rate (FAR) indices were used to verify the accuracy of the ship detection algorithm in this study. As a result of the verification, POD was similar and FAR was improved by 6.4% compared to the result of applying only SDI.

Evaluation of Retrieval Accuracy of NO2 Column Density from Pandora Raw Data According to Wavelength Range and Absorption Cross-section Using DOAS Method (Pandora 원시자료로부터 차등흡수분광법을 이용하여 이산화질소 칼럼 농도 산출 시 파장 구간 및 흡수단면적에 따른 산출 정확도 평가)

  • Kim, Serin;Kim, Daewon;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.2
    • /
    • pp.215-222
    • /
    • 2022
  • In this study, the effect of wavelength range and absorption cross-section used to retrieve nitrogen dioxide (NO2) vertical column density (VCD) from Pandora was analyzed using Differential Optical Absorption Spectroscopy (DOAS). During the GEMS Map of the Air Pollution (GMAP) 2020 campaign, data from direct sunlight observation with Pandora instrument in Seosan was used, and NO2 VCD was retrieved under four conditions. The average NO2 VCD under the four conditions ranged from 1.22×1016~1.38×1016 molec. cm-2, with a maximum difference of 0.16×1016 molec. cm-2 between each condition. The fitting error averaged 3.19~9.59%, showing an error within 10% in all cases, and the RMS was 5.11×10-3~7.16×10-3 molec. cm-2. The retrieved NO2 VCD using 4 conditions shows a slope in the range of 0.98 to 1.09 and correlation of 0.96 to 0.98 in comparison with Pandonia Global Network (PGN).

A Study on the Effects of Read Along by Google with Primary ELLs' Pronunciation and Affective Domains (구글 Read Along 앱 활용이 초등영어학습자의 발음과 정의적 영역에 미치는 효과)

  • Yoon, Tecnam
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.10
    • /
    • pp.437-444
    • /
    • 2022
  • The purpose of this study was to investigate the effects of Read Along by Google with primary English learners' pronunciation and affective domains. In order to answer these two questions, a 4-week pilot study was conducted with 24 participants in the 6 th grade. Read Along as a main learning tool was utilized for a reading-aloud activity, and a pre-/post pronunciation test and survey on the affective factors were distributed as a research instrument. The results indicated that a read-aloud activity with Read Along brought a positive impact on the development of learners' pronunciation ability in terms of accuracy and fluency. Participants showed improvement in the post-pronunciation test, compared to the pre-one and there was a significant difference based on the result of the paired samples t-test. Next, the results of the survey on the affective domains illustrated that participants showed overall improvement in learning interest and confidence and there was a significant difference in these factors. Yet, there was not a significant difference in the learning attitude, even though they showed partial improvement.

Effect of Tongue Exercise on Stroke Patients With Dysphagia : A Systematic Review (혀 운동(tongue exercise)이 연하장애를 가진 뇌졸중 환자에게 미치는 효과 : 체계적 고찰)

  • Son, Yeong Soo;Choi, Yoo Im
    • Therapeutic Science for Rehabilitation
    • /
    • v.11 no.3
    • /
    • pp.7-22
    • /
    • 2022
  • Objectives : This study was a systematic review of tongue movements in stroke patients with dysphagia. This study aimed to provide a basis for verifying the effects of tongue movement and identifying the tendency of tongue movement. Methods : A systematic review was conducted using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses checklist and flow chart. PubMed, MEDLINE, CINAHL, RISS, and e-articles databases were searched. A total of six documents were investigated, and the PEDro scale was used to evaluate the quality of the papers. Results : Three intervention methods were included in the six papers analyzed. Regarding the type of tongue exercise, three TPRT (Tongue to Palate Resistance Trainings) and two TSAT (Tongue Strength and Accuracy Training) were mediated through the IOPI (Iowa Oral Performance Instrument), and only one study applied TSE (Tongue Stretching Exercise). The treatment effects for each intervention implemented in the literature were confirmed to be effective. However, generalizability of findings is difficult because of the small sample size. Further, no significant difference was found between the experimental and control groups. Conclusions : This study can help occupational therapists provide efficient swallowing rehabilitation treatment by applying tongue exercises to stroke patients with dysphagia. More research should be conducted to determine the effects of tongue exercise.