• Title/Summary/Keyword: Instantaneous power control

Search Result 287, Processing Time 0.025 seconds

A Position Sensorless Control System of SRM using Instantaneous Rotor Position Estimation (순시 회전자 위치 추정을 통한 위치센서 없는 스위치드 릴럭턴스 전동기의 제어시스템)

  • Kim Min-Huei;Baik Won-Sik;Lee Sang-Suk;Park Chan-Gyu
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.976-980
    • /
    • 2004
  • This paper presents a position sensorless control system of Switched Reluctance Motor (SRM) using neural network. The control of SRM depends on the commutation of the stator phases in synchronism with the rotor position. The position sensing requirement increases the overall cost and complexity. In this paper, the current-flux-rotor position lookup table based position sensorless operation of SRM is presented. Neural network is used to construct the current-flux-rotor position lookup table, and is trained by sufficient experimental data. Experimental results for a 1-hp SRM is presented for the verification of the proposed sensorless algorithm.

  • PDF

Instantaneous Torque Estimation and Switching Angle Control for Optimal Operation of SRM (SRM의 최적운전을 위한 순시토크 추정과 스위칭 각 제어)

  • Baik Won-Sik;Kim Min-Huei;Kim Nam-Hun;Choi Kyeong-Ho;Kim Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.944-948
    • /
    • 2004
  • This paper presents a simple torque estimation method and switching angle control of Switched Reluctance Motor (SRM) using Neural Network (NN). SRM has gaining much interest as industrial applications due to the simple structure and high efficiency. Adaptive switching angle control is essential for the optimal driving of SRM because of the driving characteristic varies with the load and speed. The proper switching angle which can increase the efficiency was investigated in this paper. NN was adapted to regulate the switching angle and nonlinear inductance modelling. Experimental result shows the validity of the switching angle controller.

  • PDF

Air Gap Control of Hybride Bearingless SRM (하이브리드극 구조의 베어링리스 SRM 공극 제어)

  • Wang, Huijun;Park, Tae-Hub;Kim, Tae-Hyoung;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.268-270
    • /
    • 2008
  • Bearingless switched reluctance motors (SRM) have combined advantages of conventional SRM and magnetic bearings. Therefore in this paper based on novel structure of Bearingless SRM, an accurate mathematic model of radial force is deduced. Meanwhile in order to realize steady suspending, a novel radial force control method- Direct Instantaneous Radial Force Control (DIRFC) is presented. The effectiveness of new model and DIRFC is proved by the simulation results.

  • PDF

The reduction of spatter in $CO_2$ inverter Arc Weling machine by the current control at the moment of short (단락순간의 전류제어에 의한 $CO_2$ 인버터 아크 용접기의 스패터 저감)

  • 고재석;채영민;이승요;목형수;최규하
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.585-590
    • /
    • 1999
  • The conventional $CO_2$ inverter arc machine has constant voltage output characteristic and uses constant wire speed controller for welding current control. By adoption of PWM inverter to the welding machine, the spattering was reduced rather than the thyrister arc welding machine or AC arc welding machine. Moreover, by the high switching frequency, the output reactor size could be reduced evidently. Recently, the studies on optimal voltage and current waveform for the welding performance improvement have been studied. In this paper, a new instantaneous output current control scheme during the short circuit mode was proposed and showed the capability of arc stability improvement and the reduction of spatter generation.

  • PDF

Instantaneous Control of Single Phase AC/DC PWM Parallel Converters (단상 AC/DC PWM 병렬 컨버터의 순시 제어)

  • Won June-Hee;Cheong Dal-Ho;Oh Jae-Yoon
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.356-359
    • /
    • 2001
  • In this paper, the new control algorithm is proposed that compensates instantaneously the active and reactive components of the input currents by the synchronous d,q axis conversion of a single-phase current in controlling the single-phase AC/DC parallel converters for a high speed train. The leakage inductance of a transformer was used as a boost inductance and the ripple of a transformer's primary current was reduced considerably by the parallel operation of the two converters with a proper switching phase-shift. The stable and fast control response characteristic is certificated by a simulation.

  • PDF

Symbol Error Rate Analysis for Fixed Multi-User Superposition Transmission in Rayleigh Fading Channels (레일레이 페이딩 채널에서 고정적 다중사용자 중첩 전송에 대한 심벌 오차율 성능 분석)

  • Lee, In-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.10
    • /
    • pp.1379-1385
    • /
    • 2018
  • In the conventional multi-user superposition transmission, the power allocation coefficients of data symbols and the received signal processing of users are determined by the condition of instantaneous channel powers. However, the use of instantaneous channel powers can increase the system complexity. Hence, we consider fixed multi-user superposition transmission using average channel powers. The fixed multi-user superposition transmission can reduce the system complexity because it uses the condition of average channel powers that slowly change over time in order to decide the power allocation coefficients and the received signal processing. In this paper, we analyze the average symbol error rate for the fixed multi-user superposition transmission. In particular, an expression for the average symbol error rate of M-ary Quadrature Amplitude Modulation is derived assuming Rayleigh fading channels. In addition, through the numerical results, we show that the conventional and fixed multi-user superposition transmissions achieve the similar average symbol error rate performances at the user in the severe channel condition.

Electric Arc Furnace Voltage Flicker Mitigation by Applying a Predictive Method with Closed Loop Control of the TCR/FC Compensator

  • Kiyoumarsi, Arash;Ataei, Mohhamad;Hooshmand, Rahmat-Allah;Kolagar, Arash Dehestani
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.116-128
    • /
    • 2010
  • Modeling of the three phase electric arc furnace and its voltage flicker mitigation are the purposes of this paper. For modeling of the electric arc furnace, at first, the arc is modeled by using current-voltage characteristic of a real arc. Then, the arc random characteristic has been taken into account by modulating the ac voltage via a band limited white noise. The electric arc furnace compensation with static VAr compensator, Thyristor Controlled Reactor combined with a Fixed Capacitor bank (TCR/FC), is discussed for closed loop control of the compensator. Instantaneous flicker sensation curves, before and after accomplishing compensation, are measured based on IEC standard. A new method for controlling TCR/FC compensator is proposed. This method is based on applying a predictive approach with closed loop control of the TCR/FC. In this method, by using the previous samples of the load reactive power, the future values of the load reactive power are predicted in order to consider the time delay in the compensator control. Also, in closed loop control, two different approaches are considered. The former is based on voltage regulation at the point of common coupling (PCC) and the later is based on enhancement of power factor at PCC. Finally, in order to show the effectiveness of the proposed methodology, the simulation results are provided.

A Study on Current Harmonics Reduction and Unbalanced Source Voltage Compensation Using Series Active Power Filter and Parallel Passive Filter (직렬 능동전력필터와 병렬 수동필터를 이용한 고조파 전류 저감 및 불평형 전원 전압 보상에 관한 연구)

  • Oh, Jae-Hoon;Ko, Su-Hyun;Han, Yoon-Seok;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.196-199
    • /
    • 2001
  • This paper deals with current harmonics and unbalanced source voltages compensation using combined filter system. Filter system consists of a series active filter and parallel passive filters. Passive filters were a traditional method to compensate current harmonics, so those were installed in power system widely. The active filter can be a substitution to improve filtering characteristics and complement drawbacks of the passive filter. The combined system of the active power filter and passive filter can has a better compensation performances and economical goods. The series type active power filter injects compensation voltage into power system by transformers. It's compensation principle is able to applicate for voltage compensation. A new control algorithm for series active filter to compensate current harmonics and unbalanced source voltages is proposed. In the proposed algorithm, a compensation voltage for harmonic reduction is calculated directly by instantaneous reactive power theory, and a compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. By experiments, we show validity of proposed compensation method.

  • PDF

High Power Energy Harvesting Systems for IoT Sensor Nodes Systems (IoT 센서노드 시스템을 위한 고출력 에너지 하베스팅 시스템)

  • Kim, Yongseok;Park, Yong Su;Baek, Donkyu
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.27 no.4
    • /
    • pp.29-36
    • /
    • 2022
  • Existing IoT sensor nodes operate by receiving energy from a battery. But due to the characteristics of sensor nodes that are widely distributed for collecting various information, there is a disadvantage that the battery needs to be periodically replaced. In order to overcome this disadvantage, energy can be harvested from sunlight or high-temperature steam through an energy harvesting system. However, since the harvested power is quite limited, it is difficult to use applications that require instantaneous high power such as communication. We propose the design of the high-power energy harvesting system where a switch control unit compensates for the limited harvested energy with the energy storage device such as a capacitor. To verify the proposed system, an energy harvesting system based on sunlight was implemented, and we confirmed the maximum supply power to the application and the maximum supply time according to capacity of the energy storage device.

A Simple Resonant DC Link Snubber-Assisted Bi-directional Three-phase PWM Converter for Battery Energy Storage Systems

  • Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.133-139
    • /
    • 2002
  • In this paper, a prototype of an active auxiliary quasi-resonant DC link (QRDCL) snubber assisted voltage source bidirectional power converter (AC to DC and DC to AC) operating at zero voltage soft-switching (BVS) PWM nlode is presented for a Battery Energy Storage System (BESS). The operating principle of this QRDCL circuit and multifunctional control-based converter system, including PWM inverter mode in which energy flows from the battery bank to the three-phase utility-grid in addition to an active PWM converter mode in which energy flows from the utility-grid to the battery banks are described respectively by the control implementation on the basis of d-q coordinate plane transformation. The multifunctional operation characteristics of this three-phase ZVS PWM bi-directional converter with QRDCL is demonstrated fer a BESS under the power conditioning and processing schemes of energy supply mode and energy storage mode, and compared with a conventional three-phase hard switching PWM bi-directional converter for a BESS. The effectiveness of the three-phase ZVS PWM hi-directional converter with QRDCL is proven via the simulation analysis.