• 제목/요약/키워드: Instantaneous compensation

검색결과 117건 처리시간 0.026초

An ANN Controlled Three-Phase Auto-Tuned Passive Filter for Harmonic and Reactive Power Compensation

  • Sindhu, M.R.;Nair, Manjula;Nambiar, T.N.P.
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.403-409
    • /
    • 2009
  • Automatically tuned passive filters can improve power quality to a great extent in power systems. A novel three-phase shunt auto-tuned filter is designed to effectively compensate source current harmonics and to provide reactive power required by the non-linear load, which draws a highly reactive, harmonic-rich current from the supply. An artificial neural network (ANN) based controller selects filter component values in accordance with reactive power requirement and harmonic compensation. Traditional passive filters are permanently connected to the system and draw large amounts of source current even under light load conditions. By using auto-tuned filters, the passive filter components can be controlled according to load variations and, hence, draw only required source currents. The selection is done by the ANN with the help of a properly tuned knowledge base to provide instantaneous compensation using a digital controller.

상관함수에 의한 순시전력이론을 이용한 DSP 능동전력필터 (A DSP Based Active Power Filter with Instantaneous Correlation Power Theory)

  • 정영국;임영철
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.50-56
    • /
    • 1999
  • 본 연구에서는 시간영역에서 전력이 해석되어지므로 이해하기 쉽고, 비교적 계측하기 용이한 상관함수에 의한 순시전력이론에 대해서 고찰하였다. 상관함수에 의한 순시전력이론은 시간영역에서 전압과 전류의 자기상관함수와 상호상관함수에 의해서 전력과의 전압과 상관성에 따라 상관전력과 비상관 전력으로 분해된다. 분해된 두 가지 전력성분으로부터 비선형 부항의 특성에 따라 전력과 전류를 유효성분, 기본파 무효성분 그리고 고조파성분 등 3성분으로 분해한다. 능동전력필터는 그 보상특성상 전력과 전류의 3성분만을 다루며, 실시간 제어를 위해 그외의 여러 복잡한 그리고 구현의 어려움이 있는 전력모델은 경제적이지 못하다. 상관함수적인 순시전력이론에 의해 분석된 전력성분들의 타당성을 입증하기 위해서 전압형 DSP능동전력필터를 제작하였다. 싸이리스터 제어 유도전동기 구동시스템의 전력을 제안된 순시전력이론에 의해 3성분으로 분해한 후, 이들 성분중에서 보상기준전류로 고조파성분과 기본파 무효성분을 각각 제어하여 그 보상결과로부터 타당성을 입증하였다.

회전좌표계를 이용한 단상능동전력필터의 제어방법에 관한 연구 (A study on the Control Method of Single-Phase APF Using RRF Method)

  • 김영조;허진석;김영석
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.576-584
    • /
    • 2003
  • 본 논문에서는 비 선형 단상부하에 의해 발생하는 전류 고조파를 보상하기 위한 단상능동전력필터의 새로운 제어방법을 제안한다. 부하전류에 시간지연을 주어 임의의 두 번째 상을 생성한 후 단상시스템을 두 상을 갖는 시스템으로 만들어 복소계산을 가능하게 한다. 기존의 방법은 부하전류를 1/4 T(T는 기본파의 주기) 만큼 지연시켜서 가상의 상을 만들었지만, 본 논문에서 제안하는 방법은 저역통과필터가 상 지연의 특성을 가지는 것을 이용하여 필터를 통과한 지연된 위상을 가진 새로운 신호를 두 번째 상으로 이용하였다. 두 개의 위상이 다른 상이 존재하므로 고조파 전류의 순시계산이 가능하게 된다. 기존의 고정좌표계를 이용하여 순시무효전력이론을 적용하지 않고, 본문에서는 전원주파수에 동기하는 회전좌표계를 사용하여 순시계산을 하였고, 보상전류 지령치를 구하였다. 전류원으로 사용되는 RL부하에 대하여 시뮬레이션과 실험을 수행하였고, 제안된 제어법의 유효성을 입증하였다.

직렬 능동전력필터와 병렬 수동필터를 이용한 고조파 전류 저감 및 불평형 전원 전압 보상에 관한 연구 (A Study on Current Harmonics Reduction and Unbalanced Source Voltage Compensation Using Series Active Power Filter and Parallel Passive Filter)

  • 오재훈;고수현;한윤석;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.196-199
    • /
    • 2001
  • This paper deals with current harmonics and unbalanced source voltages compensation using combined filter system. Filter system consists of a series active filter and parallel passive filters. Passive filters were a traditional method to compensate current harmonics, so those were installed in power system widely. The active filter can be a substitution to improve filtering characteristics and complement drawbacks of the passive filter. The combined system of the active power filter and passive filter can has a better compensation performances and economical goods. The series type active power filter injects compensation voltage into power system by transformers. It's compensation principle is able to applicate for voltage compensation. A new control algorithm for series active filter to compensate current harmonics and unbalanced source voltages is proposed. In the proposed algorithm, a compensation voltage for harmonic reduction is calculated directly by instantaneous reactive power theory, and a compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. By experiments, we show validity of proposed compensation method.

  • PDF

순간정전 보상을 갖는 능동 전력 필터 (An active power filter with an instantaneous power failure compensation)

  • 이용덕;이우철;이택기;김득수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.293-295
    • /
    • 2007
  • This paper proposes a control algorithm for the power supply to maintain the desired output voltage waveform when the instantaneous power failure occurs. The proposed system switches the control mode between the voltage-controlled and the current-controlled modes in the instantaneous power failure. The proposed control method has little steady-state error and good transient response. The validity of the proposed scheme is investigated through simulation and experimental results.

  • PDF

2상 유도전동기용 벡터제어 인버터를 위한 전류측정 오차 보상 방법 (Compensation Method of Current Measurement Error for Vector-Controlled Inverter of 2-Phase Induction Motor)

  • 이호준;윤덕용
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1204-1210
    • /
    • 2016
  • The phase currents must be accurately measured to achieve the instantaneous torque control of AC motors. In general, those are measured using the current sensors. However, the measured current signals can include the offset errors and scaling errors by several components such as current sensors, analog amplifiers, noise filter circuits, and analog-to-digital converters. Therefore, the torque-controlled performance can be deteriorated by the current measurement errors. In this paper we have analyzed the influence caused by vector control of 2-phase induction motor when two errors are included in measured phase currents. Based on analyzed results, the compensation method is proposed without additional hardware. The proposed compensation method was applied vector-controlled inverter for 2-phase induction motor of 360[W] class and verified through computer simulations and experiments.

순시전압강하 보상 기능을 가지는 무정전전원공급장치의 개발 (Development of Uninterruptible Power Supply with Voltage Sag Restorer Function)

  • 박종찬;손진근
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.95-101
    • /
    • 2014
  • In this paper, UPS, with a built-in instantaneous sag drop compensation features, was developed to improve performance. The improved UPS, using instantaneous moving average method, compensates by quickly measuring the voltage and series inverter of half-bridge type, using line-interactive method that links with the voltage of the battery and power source, was developed. In addition, by developing a parallel inverter that uses a high-efficiency PWM switching method, overall UPS system was enhanced. To verify the performance of the proposed algorithm, single-phase 5[kVA] UPS systems were designed and the experimental system was constructed. The low-cost type of Cortex-M3 module CPU STM32F103R8T6 (32[bit]) is attached and the switching time of mode transfer was set within 4 [ms]. THD of the linear load operates in less than 3[%], and the stability of the output voltage operates in approximately ${\pm}2[%]$ range. The superior performance of the operations was confirmed with the system set as above.

유도전동기의 속응 토크제어를 위한 파라미터 변동의 적응보상기법 (Adaptive Compensation Technique of Parameter Variation for Quick Torque Response of an Induction Motor Drive)

  • 손진근;정을기;김준환;전희종
    • 전력전자학회논문지
    • /
    • 제3권3호
    • /
    • pp.206-213
    • /
    • 1998
  • 본 논문에서는 유도전동기의 속응 토크제어를 위한 파라미터 변동의 적응보상기법을 제안하였다. 제어성능을 현저히 저하시키는 원인으로 작용하는 파라미터의 변동을 보상하기 위하여 본 논문에서는 모델기준 적응제어(MRAC)방식을 적용하여 회전자 저항값 변동을 추정 보상한다. 본 적응제어방식은 실측 순시무효전력과 추정 순시무효전력의 오차관계에서 실시간으로 회전자 저항값 변동을 추정 보상하는 방식이다. 본 방식은 전동기 파라미터를 사용하지 않고 실측 순시무효전력을 기준모델로 적용하기 때문에 전동기 등 등가모델에서 구한 기존의 다른 기준모델에 비해 강인한 시스템이 된다. 추정된 회전자 저항값을 이용하여 자속관측기를 구성하고 이를 직접베터 제어방식에 적용하였으며, 시뮬레이션 및 실험을 통하여 속응 토크제어가 원활히 수행됨을 입증하였다.

  • PDF

능동필터형 쌍방향 UPS의 새로운 제어기법 (A novel control strategy of active power filter type bidirectional UPS)

  • 김제흥;염상구;최재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2082-2084
    • /
    • 1997
  • This paper proposes a new control strategy of bidirectional uninterruptible power supply(UPS) with the performance of active power filter which compensate the harmonics and reactive power. To improve the transient response for the effective compensation in active power filter mode, it is considered that a simple and precise calculation method of the compensation reference current for the harmonics and reactive power compensation. So a novel closed-loop control strategy is used to calculate the reference current. And the current regulated instantaneous voltage control scheme is used in back-up power mode. The system model and control algorithm are described and analyzed, and the system Performance is verified by the simulation and experimental results.

  • PDF

순간전압변동 보상 기능을 갖는 3상 하이브리드형 직렬 능동전력필터 (3-Phase Hybrid Series Active Power Filter with Instantaneous Voltage Fluctuations Compensation)

  • 이승요
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.739-743
    • /
    • 2000
  • With significant development of power electronics technology the proliferation of nonlinear loads such as such as static power converters has deteriorated power quality in power transmission distribution systems. Notably voltage harmonics resulting from current harmonies produced by the nonlinear loads have become a serious problem in many systems Moreover momentary interruptions and voltage sags are responsible for many of the power quality problems found in typical industrial plants. Int his paper proposed 3 phase hybrid series active power filter is not only for harmonic compensation but also for harmonic isolation between supply and load and for voltage regulation and imbalance compensation Through computer simulations we have verified the effectiveness of the proposed system.

  • PDF