• Title/Summary/Keyword: Instantaneous Voltage control

Search Result 205, Processing Time 0.023 seconds

Minimization of Active Power and Torque Ripple for a Doubly Fed Induction Generator in Medium Voltage Wind Power Systems under Unbalanced Grid Conditions

  • Park, Yonggyun;Han, Daesu;Suh, Yongsug;Choi, Wooyoung
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.1032-1041
    • /
    • 2013
  • This paper investigates control algorithms for a doubly fed induction generator with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power systems under unbalanced grid conditions. Three different control algorithms to compensate for unbalanced conditions have been investigated with respect to four performance factors; fault ride-through capability, instantaneous active power pulsation, harmonic distortions and torque pulsation. The control algorithm having a zero amplitude of torque ripple shows the most cost-effective performance concerning torque pulsation. The least active power pulsation is produced by the control algorithm that nullifies the oscillating component of the instantaneous stator active and reactive powers. A combination of these two control algorithms depending on the operating requirements and the depth of the grid unbalance presents the most optimized performance factors under generalized unbalanced operating conditions leading to high performance DFIG wind turbine systems.

Design and Implementation of Instantaneous Power Estimation Algorithm for Unified Power Conditioner

  • S., Sindhu;M.R., Sindhu;Nambiar, T.N.P.
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.815-826
    • /
    • 2019
  • This paper discusses a simple control approach for a Unified Power Conditioner (UPC) system to achieve power quality compensation at the point of common coupling in distribution systems. The proposed Instantaneous Power Estimation Algorithm (IPEA) for shunt and series active power filters uses a simple mathematical concept that reduces the complexity in the design of the controller. The performance of a UPC is verified with a system subjected to voltage distortions, sags/swells and unbalanced loads using MATLAB/SIMULINK. The simulation study shows that a UPC with the proposed control algorithm can effectively compensate for voltage and current harmonics, unbalance and reactive power. The control algorithm is experimentally implemented using dSPACE DS1104 and its effectiveness has been verified.

Space Vector Modulated Three-Phase Soft-Switching Active Rectifier and Its Performance Evaluations

  • Fujii Yuma;Ahmed Tarek;Imamura Kosuke;Hiraki Eiji;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.213-215
    • /
    • 2003
  • This paper presents an instantaneous space vector modulated voltage source type three-phase soft-switching PFC rectifier using a single auxiliary resonant DC Link snubber for alternative energy utilizations. in the first place, the operating principle of an active auxiliary resonant DC link snubber circuit is described including its unique features. In the next place, the simulation analysis of three-phase soft-switching PWM rectifier is implemented, and the operating performances or the three-phase voltage-fed PWM rectifier treated here, which can operate under the conditions of sinewave line current shaping and utility power factor are evaluated and discussed on tile basis of this simulation results.

  • PDF

Instantaneous Voltage Sag Corrector Using Series Compensator in Transfer Power Line Generator (송전선 직렬보상을 이용한 순시전압강하 보상기)

  • Lee, Sang-Hoon;Min, Wan-Ki;Jeon, Byeong-Seok;Lee, Dae-Jong;Hong, Hyun-Mun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.21-25
    • /
    • 2006
  • This paper describes the novel control techniques design of VSC(Voltage Sag Corrector) for the purpose of power line quality enhancement. A fast detecting technique of voltage sag is implemented through the detection of instantaneous value on synchronous rotating do-reference frame. The first order digital filter is added in the detection algorithm to protect the insensitive characteristics against the noise. The relationship between the total detection time and cut-off frequency of the filter is described. The size of the capacitor bank used as the energy storage element is designed from the point of view of input/output energy with circuit analysis. Finally, the validity of the proposed scheme is proven through the simulated results.

A Current Sharing Circuit for the Parallel Inverter

  • Lee, Chang-Seok;Kim, Si-Kyung
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.176-181
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employs active and reactive power control of frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel-connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employees an instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Furthermore, the proposed control scheme is verified through the experiment in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF

A Torque Ripple Reduction of Miniature BLDC using Instantaneous Voltage Control (초고속 소형 BLDC의 순시 전압 제어에 의한 토크 리플 억제)

  • Lee, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.191-198
    • /
    • 2007
  • This paper proposes the instantaneous source voltage and phase current control for torque ripple reduction of a high speed miniature BLDC motor. As compared with general BLDC motor, a high speed miniature BLDC motor has a fast electrical time-constant. So the current and torque ripple are very serious in a conventional PWM switching during conduction period. In order to reduce the switching current ripple, instantaneously controlled source voltage is supplied to the inverter system according to the motor speed and load torque. In addition, the fast hysteresis current controller can keep the phase current In the limited band. The proposed method is verified by the computer simulation and experimental results.

A Study on the Unity Power Factor Converter to Inhibit Harmonics of Distributed Line (배전선로의 고조파 성분억제가 가능한 단위역률 전력변환기 개발에 관한 연구)

  • 박성준;변영복;권순재;김철우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.5
    • /
    • pp.57-63
    • /
    • 1995
  • In this paper, 3-Phase PWM AC/DC step up type converter that reduces the harmonics and reactive power of the distribution line is analyzed and the stable control method is proposed as controlling the sinusoidal phase current and phase voltage in phase. In implementation of controller, simple control algorithm is derived as the instantaneous voltage control methods without current sensor. The instantaneous voltage is controled by PWM method and the switching frequency is presented in low range 3 [kHz] for reducing the switching loss. In case of active load, four quadrants operation converter regenerate power from the load to the power source is conducted. Through the computer simulation and experimentation, the proposed control method is justified.

  • PDF

A Parallel Inverter System with an Instantaneous Power Balance Control (순시전력 균형제어를 이용한 병렬 인버터 시스템)

  • Sun, Young-Sik;Lee, Chang-Seok;Kim, Si-Kyung;Kim, Chang-Bong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.1
    • /
    • pp.19-28
    • /
    • 2000
  • The parallel inverter is widely utilized because of its fault-tolerance capability, high-current output at constant voltages and system modularity. The conventional paralled inverter usually employes an active and reactive power control or a frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes novel control scheme for equalization of output power between the parallel connected inverters. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employes a instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Futhermore, the proposed constrol scheme is verified through the simulation in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF

Adaptation of Space Vector Modulation to Single-Phase High Power PWM Converters (단상 PWM 컨버터에 적용한 공간 벡터 PWM)

  • Lee, Hee-Myun;Lee, Dong-Myung
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.442-443
    • /
    • 2011
  • In this paper, a voltage control method based on DQ transformation and Space Vector Pulse Width Modulation (SVPWM) for a single phase three-level converter is proposed. This control method is designed to use DC values instead of using instantaneous values of current which are usually used in single-phase application, so that it results in a fast and robust voltage control response. Simulation results demonstrate the validity of the control strategies.

  • PDF

Stand-Alone Wind Energy Conversion System with an Asynchronous Generator

  • Singh, Bhim;Sharma, Shailendra
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.538-547
    • /
    • 2010
  • This paper deals with a stand-alone wind energy conversion system (WECS) with an isolated asynchronous generator (IAG) and voltage and frequency (VF) control feeding three-phase four-wire loads. The reference generator currents are estimated using the instantaneous symmetrical component theory to control the voltage and frequency of an IAG system. A three-leg voltage source converter (VSC) with an isolated star/delta transformer is used as an integrated VSC. An integrated VSC with a battery energy storage system (BESS) is used to control the active and reactive powers of the WECS. The WECS is modeled and simulated in MATLAB using the Simulink and the Sim Power System (SPS) toolboxes. The proposed VF controller functions as a voltage and frequency regulator, a load leveler, a load balancer and a harmonic eliminator in the WECS. A comparison is made on the rating of the VSC with and without ac capacitors connected at the terminals of an IAG. Simulation and test results are presented to verify the control algorithm.