• Title/Summary/Keyword: Instantaneous Reactive Power Control

Search Result 80, Processing Time 0.034 seconds

New Sensorless Control of PMSM using Reactive Power (무효전력을 이용한 영구자석 동기전동기의 새로운 센서리스 제어)

  • Han, Yoon-Seok;Choi, Jung-Soo;Kim, Young-Seok;Shin, Jae-Wha
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.237-239
    • /
    • 2001
  • This paper presents a new speed sensorless control method of permanent magnet synchronous motors based on instantaneous reactive power. The proposed system is constructed in a synchronously rotating reference frame and is very simple. The new approach is not dependent upon the stator resistance, nor is it affected by mechanical motor parameters. The effectiveness of the proposed system is confirmed by the simulation results.

  • PDF

Sensorless Vector Control for PMSM Using Instantaneous Reactive Power (무효전력을 이용한 영구자석 동기전동기의 위치 및 속도 센서리스 제어)

  • Jin, Chang-Eon;Han, Yoon-Seok;Shin, Jae-Wha;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1053-1055
    • /
    • 2000
  • This paper describes a new approach to estimating permanent magnet synchronous motor(PMSM) speed and position from measured terminal voltages and currents for speed-sensorless vector control. The proposed system is based on observing the instantaneous reactive power of the motor. The described technique is very simple and robust to variations of motor parameters. The new approach is not dependent upon the value of the stator resistance. Also, MRAS schemes are chosen for determining the adaptive law for the speed and the position estimator. The effectiveness is verified by simulation.

  • PDF

Sensorless Control of IPMS on an Instantaneous Reactive Power Preceding Initial Position Estimation and Parameter Measurement (초기위치 추정 및 파라미터 계측을 선행하여 순시무효전력을 이용한 IPMSM의 센서리스 제어)

  • Kim, Won-Suk;Joung, Woo-Talk;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.207-209
    • /
    • 2005
  • Recently, the use of IPMSM is coming to be active, in many industrial applications. In sensorless drive of IPMSM, it is important to know the exact information of the initial rotor position, because the wrong estimation of the initial rotor position brings about the decrease of the starting torque, or a temporary reverse revolution, In addition, PMSM is necessary to use the accurate information of the inductance for the precise torque control owing to the reluctance torque. In this paper presents initial rotor position estimation method and, measure method of the each-axis inductance. And to minimize the speed estimations error, the estimated speeds are compensated by using an instantaneous reactive power in synchronously rotating reference frame.

  • PDF

Sensorless Vector Control for PMSM Using Instantaneous Reactive Power (무효전력을 이용한 영구자석 동기전동기의 위치 및 속도 센서리스 제어)

  • Jin, Chang-Eon;Han, Yoon-Seok;Shin, Jae-Wha;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.384-386
    • /
    • 2000
  • This paper describes a new approach to estimating permanent magnet synchronous motor(PMSM) speed and position from measured terminal voltages and currents for speed-sensorless vector control. The proposed system is based on observing the instantaneous reactive power of the motor. The described technique is very simple and robust to variations of motor parameters. The new approach is not dependent upon the value of the stator resistance. Also, MRAS schemes are chosen for determining the adaptive law for the speed and the position estimator. The effectiveness is verified by the experimental results.

  • PDF

A Current Sharing Circuit for the Parallel Inverter

  • Lee, Chang-Seok;Kim, Si-Kyung
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.176-181
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employs active and reactive power control of frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel-connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employees an instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Furthermore, the proposed control scheme is verified through the experiment in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF

A novel control strategy of active power filter type bidirectional UPS (능동필터형 쌍방향 UPS의 새로운 제어기법)

  • Kim, Je-Hong;Yeom, Sang-Ku;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2082-2084
    • /
    • 1997
  • This paper proposes a new control strategy of bidirectional uninterruptible power supply(UPS) with the performance of active power filter which compensate the harmonics and reactive power. To improve the transient response for the effective compensation in active power filter mode, it is considered that a simple and precise calculation method of the compensation reference current for the harmonics and reactive power compensation. So a novel closed-loop control strategy is used to calculate the reference current. And the current regulated instantaneous voltage control scheme is used in back-up power mode. The system model and control algorithm are described and analyzed, and the system Performance is verified by the simulation and experimental results.

  • PDF

Sensorless Controller for a Interior Permanent Magnet Synchronous Motor based on a Fuzzy Controller and Instantaneous Reactive Power (퍼지 제어기와 순시무효 전력을 이용한 IPMS모터의 Sensorless 제어)

  • Kang, Hyoung-Seok;Joung, Woo-Taik;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.175-177
    • /
    • 2005
  • An interior permanent magnet synchronous motor (IPMSM) is receiving increased attention for many industrial applications because of its high torque to inertia ratio, superior power density, and high efficiency. This paper presents algorithm for speed sensorless vector control based on a fuzzy controller and an instantaneous reactive power. Effectiveness of algorithm is confirmed by the experiments.

  • PDF

Multifunctional UPS with Mode Transfer Method (모드절환식 다기능 무정전 전원장치)

  • Kim, Je-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1049-1051
    • /
    • 2001
  • This paper proposes a new control strategy of multifunctional uninterruptible power supply(UPS) with the performance of active power filter which compensate the harmonics and reactive power. To improve the transient response for the effective compensation in active power filter mode, it is considered that a simple and precise calculation method of the compensation reference current for the harmonics and reactive power compensation. So a novel closed-loop control strategy is used to calculate the reference current. And the current regulated instantaneous voltage control scheme is used in back-up power mode. The system model and control algorithm are described and analyzed, and the system performance is verified by the simulation results.

  • PDF

New Control Strategy for Three-Phase Grid-Connected LCL Inverters without a Phase-Locked Loop

  • Zhou, Lin;Yang, Ming;Liu, Qiang;Guo, Ke
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.487-496
    • /
    • 2013
  • The three-phase synchronous reference frame phase-locked loop (SRF-PLL) is widely used for synchronization applications in power systems. In this paper, a new control strategy for three-phase grid-connected LCL inverters without a PLL is presented. According to the new strategy, a current reference can be generated by using the instantaneous power control scheme and the proposed positive-sequence voltage detector. Through theoretical analysis, it is indicated that a high-quality grid current can be produced by introducing the new control strategy. In addition, a kind of independent control for reactive power can be achieved under unbalanced and distorted grid conditions. Finally, the excellent performance of the proposed control strategy is validated by means of simulation and experimental results.

A New Control Method of Series Single-Phase Hybrid Active Power Filter (직렬형 단상 하이브리드 능동 전력필터의 새로운 제어법)

  • Kim, Jin-Sun;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.149-151
    • /
    • 2005
  • This paper deals with the novel control algorithm of single-phase hybrid active power filter for the compensation of harmonic current components in nonlinear R-L load with passive active power filters. To construct two-axes coordinate, an imaginary second phase was made by giving time delay to line current. In this proposed method, the new signal, which was the delayed through the filtering by the phase-delay property of low-pass filter, is used as the secondary phase. Because two phases have different phase, instantaneous calculation of harmonic current is possible. In this paper, a reference voltage is created by multiplying gain of filter by compensation current using the rotating reference frames that synchronizes with source-frequency, not applying to instantaneous reactive power theory which has been used with the existing fixed reference frames. This paper shows the experimental results, which provide a high accuracy and extremely fast response of single-phase hybrid active Bower filter under the operation with the proposed control method.

  • PDF