Gondola is widely used as a construction facility to perform external finishing work without using scaffolding at a construction site. However, since 2000, there have been 17 deaths from now so these risks associated with work can not be ignored. Therefore, it is expected that it will contribute greatly to prevent related disasters if introducing necessary measures to prevent repeated related disasters and installing additional safety devices. In order to eliminate the risk factor according to the operation of the gondola, it is necessary for the operator to use it to use it while the examination of each product is completed, and to use the over load Dangerous arbitrary measures such as arbitrary operation of the prevention device, removal of the safety fence for convenience of work, installation of the wire rope installed in the air, falling out of the wire rope and falling to the ground Do not perform such sealing measures so that any operation of the overload prevention device can not be done so as not to take such arbitrary measures, or wire the power supply wire to the safety fence so as not to delete the safety fence. Then, when the safety fence is removed, so that it does not become a gondola operation, or when replacing the wire rope in the air, to prevent the wire rope from coming off, Additional measures such as installing falling down prevention device may be necessary.
This study examines the Gyeongju Seokguram Grotto restoration project (1961-1962) by architect Kim Chung Up (1922-1988) and introduces the documents he wrote at the time of planning. The study highlights Kim's Plan attempt to adopt Buckminster Fuller's idea of the Geodesic Dome, while inheriting the architect Pai Ki Hyung's previous design plan which was nullified. As Seokguram Grotto's water leak and deterioration issues have been brought up, the four-times survey was carried out by experts team between 1958 and 1960, under Ministry of Education's direction. Pai designed an initial restoration plan based on the survey's result, which was a double-dome structure with a concrete film on the outer periphery as a way to protect Seokguram Grotto in January 1961. However, as drawbacks, such as the heavy load of the concrete dome, and non-installation of entrance hall, have been indicated in the review process, the Cultural Properties Committee rejected the plan. Subsequently, Kim was appointed as the supervisor of the second restoration project. Kim drew up a process management schedule to be implemented from August 1961 to December 1963 and designed the conception plans for the second restoration design. This study analyzes Kim's Plan by examining sketches, site plans, floor plans, and sections. Kim planned to maintain the idea of the double-dome structure proposed by Pai while applying Buckminster Fuller's idea of the Geodesic Dome. Kim planned to lighten the dome structure by applying a steel-frame Geodesic Dome so that the dome structure could be supported by its own. The study is expected to reclaim the omitted parts from Seokguram Grotto's historical description and Kim's careers.
본 연구에서는 터널 지보재의 거동을 전기펄스를 이용한 계측 시스템인 TDR센서를 이용하여 파악하고자 하였다. 터널 지보재의 거동을 파악하기 위해 먼저 구리테이프를 TDR센서의 계측재료로 이용하여 터널 지보재에 설치하기 위한 제작기법에 대해 연구하였다. 그 결과 구리테이프의 상부에 유리테이프, 하부에 스티로폼+전자파 차단시트를 설치했을 때 TDR센서의 민감도가 적절했고 노이즈 발생량도 적었다. PVC파이프 터널모형단면을 통해 단면의 강성과 지점 조건에 따라 데이터의 형태가 어떠한 경향을 나타내는 지 확인할 수 있었다. 이는 실제 현장에 구리테이프를 이용하여 터널 지보재의 거동을 정확히 파악하기 위해서는 지보재의 강성과 지점 조건을 현장과 동일하게 하여야 함을 알 수 있었다. TDR데이터와 유한요소해석과의 비교를 통해 TDR센서를 이용하여 터널의 거동을 파악할 수 있음을 알 수 있다. TDR데이터를 통해 지보재의 변형을 정성적으로 파악할 수 있고, 응력과 변형률 관계를 통해 지보재의 부재력까지 파악할 수 있을 것으로 기대된다.
본 연구는 임도 설계자가 보다 간편하고 정확하게 임도 배수시설을 설계하는 데에 기여할 수 있는 임도 배수시설 규격 산정 프로그램을 개발하는 데에 목적이 있다. 본 프로그램의 특징은 임도설계자가 현장 측량을 하기에 앞서 실내에서 임도의 예측을 실시할 때 현장 측량을 통해 취득해야 하는 데이터가 없이도 간편하게 강우강도를 이용하여 유역 내 유출량을 산출할 수 있도록 하였다. 그리고 이를 통해 배수구조물의 최소 규격을 산출해 줌으로써 과도한 설계를 억제할 수 있게 하였다. 또한 임도가 시설되는 지역의 각 유역별 유출량을 산출함으로써 배수구조물의 적절한 배치에 기여코자 하였다. 특히 배수관의 설치에 따른 전과정을 보고서로 작성하여 파일 및 출력물 형태로 제공함으로써 합리적인 설계과정을 보여줄 뿐만 아니라 오류 발생시 즉각적인 수정이 가능케 함으로써 임도 설계기술의 상향평준화에 기여할 수 있을 것으로 생각된다.
본 연구는 국내 가선집재 작업 현장 실태에 대한 사례 조사를 통해 작업의 생산성에 영향을 미치는 집재 작업의 설계와 가선 설치의 공학적 문제점을 파악하고, 그로 인해 손실되는 생산성과 증가되는 비용을 분석하기 위한 목적으로 수행되었다. 분석 결과, 가선집재 설계 시 현장의 지형적 입지여건과 공학적 안전성이 충분히 고려되지 않아 대부분 가선의 처짐(deflection)을 확보하지 못하는 것으로 나타났다. 이로 인해 시간 당 생산성이 최대 65%까지 감소하고, 집재비용이 2배 이상 증가되어 전반적인 작업의 효율성이 떨어지는 것으로 나타났다. 따라서 앞으로 국내에서 가선집재 작업이 확대되기 위해서는 작업 안전과 효율을 확보할 수 있는 가선의 설치와 장비의 운용, 불필요한 생산비용을 최소화할 수 있는 현장 기술의 보급이 필요하다.
후설치 앵커는 기존 콘크리트 부재에 구조 및 비구조 부재를 접합시키는 구조재료로 그 사용빈도가 점점 증가하고 있다. 하지만, 실제 현장에서 내부 철근 및 시공오류로 성능저하가 일어나는 경우가 종종 발생하고 있어 그 성능평가 과정이 필요하다. 본 연구에서는 비틀림 제어 확장형 후설치 앵커 성능을 평가하기 위하여 모재 콘크리트 압축강도와 유효 묻힘깊이를 변수로 한 단일앵커 인발시험을 수행하였다. 실무에서 가장 많이 쓰이는 M10과 M20의 인발강도 시험을 수행한 결과, M10 및 M20앵커 모두 변동계수 15% 이내 값을 가지고 있어 KCI 2012에서 제시하는 신뢰도를 모두 만족하는 것으로 나타났다. 또한, 묻힘깊이 및 콘크리트 강도가 인발강도에 영향을 미치는 것을 확인하였다. 영향 계수를 확인하기 위하여 기존 유사연의 결과 및 본 연구 결과를 바탕으로 후설치앵커의 설계식을 수정 제안하여 그 결과를 비교하였다.
최근 미세먼지에 대한 국민들의 불안감이 증가함에 비산먼지에 대한 관심이 증가하고 있다. 비산먼지는 도로재비산먼지 다음으로 건설현장에서 많이 발생하는데 이 중 대부분을 차지하는 소규모 현장은 비산먼지 관련 규정이 없어 제대로 된 관리가 이뤄지지 않고 있는 실정이다. 이에 본 연구에서는 소규모 현장 비산먼지 관리 규정 수립에 기여하고 비산먼지 저감방안을 마련하고자 서울시 소규모 현장에서 발생하는 비산먼지를 측정 및 분석을 진행했다. 소규모 현장에서 발생하는 비산먼지의 시간별 변동을 확인했고 담장과 난간 뒤에서 측정했을 때 상대적으로 농도가 낮은 것을 통해 비산먼지 저감방안으로 간이 펜스 설치 방안을 제시했다.
Generally, in construction sites, the pipe support installation workers often use support pins of 9~10 mm which are much smaller than the safety standard sizes for work convenience. Although the safety certification standard thickness of the support pins is 11 mm, and the supervisors are often indifferent to this. Hence, products with far lower performance than the pipe support safety certification value of 40,000 N, which is applied in the supporting post-structural review, are used. Accordingly, this acts as a factor causing collapse accidents in the process of pouring concrete at the construction site. Therefore, this study performed compression experiments on new and reused pipe supports to determine how the thickness of the support pins affects the structural compression performance of the pipe support by considering the thickness of the support pins as a critical variable among various factors affecting the pipe support performance. In the course of the study, the compression test of the pipe support (V2, V4) for the new products showed that only 14 (58.3%) of the total 24 samples satisfied the safety certification standard value of 40,000 N, which indicates that more thorough quality control is required in the manufacturing process. Additionally, comparing the thickness of the support pins and their fracture shape shows that the pipes with support length of 4.0 m or longer are much more affected by the buckling of the entire length than the thickness of the support pins. Of the several factors affecting the performance of reused pipe supports, it was found that, similar to the new products, the use of support pins, with thickness of 12 mm rather than 11 mm, can satisfy the safety certification value more appropriately. Therefore, regardless of the state of usage, it could be concluded that it is necessary to use 12 mm products, whose thickness is larger than that of the safety certification standard value of 11 mm, to improve the performance of the pipe supports.
3차원 초음파풍속계는 PC와 RS232C(:Recommended Standard 232C) 인터페이스로 연결하여 관측 자료를 전송한다. 관측 장소에 따라 PC와 센서를 연결하는 케이블 연장이 필요한 경우가 종종 발생한다. 항공기상청 항공기상관측장비 테스트베드에서 PC를 두는 콘테이너와 장비 설치하는 곳까지 거리가 30 m 이상 되어 본래의 AWM2919(:Appliance Wiring Material 2919) 케이블로의 연장이 필요했다. 문제 해결을 위해서 AWM2919 케이블 연장, PC와의 인터페이스를 RS232C에서 RS485로 개조, RS485 검사 등의 조치를 하였다. 연장된 케이블로 장비를 설치한 후에 원격으로 자료를 수집하고 분석하여 성공적인 케이블 연장을 확인하였다.
In this study, an analysis was conducted to analyze the structural stability of the piezoelectric power generation module and to determine the optimal burying hole interval for concrete, the installation site of the power generation module. A piezoelectric element refers to a functional ceramic having a piezoelectric direct effect that converts mechanical energy into electrical energy and a piezoelectric reverse effect. In the analysis of the piezoelectric power generation module, the load condition was applied with about 16 tons and a total of 10 wheels in consideration of the container trailer. The purpose was to evaluate the stability of major components of the piezoelectric power generation module through finite element analysis. In order to determine the optimal burying location of the concrete ground for burying the piezoelectric power generation module, the stability of the ground structure according to the distance of the holes was determined. As a result of the analysis, the maximum stress of the piezoelectric power generation module was generated in the support spring, showing a stress of about 276.7 MPa. It was found that the spacing of holes for embedding the piezoelectric power generation module should be set to a minimum of 100 mm or more.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.