보호접지로 활용하기 위한 건축물 구조체의 접지저항 측정분석 (Grounding Resistance Measurement and Analysis of Building Structures for Applying as Safety Earthing)

  • 오세중;김찬오
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.50-55
    • /
    • 2012
  • Grounding is very important for electrical safety. But it is very difficult to secure enough space for the installation and management of grounding in the city because of the congestion of the buildings. Therefore, to solve this problem, this paper suggest structure-grounding application taking advantage of building structure as protective grounding. And, to verify its feasibility, this paper shows the result to measure and analyze grounding-resistance of structure for 12 buildings mainly structed in the city.

콘크리트에 매입된 기초접지극의 크기 및 설치방법에 관한 고찰 (A Consideration of Volume and Installation Method of Concrete-Embedded Foundation Earthed an Electrode)

  • 이주철;이영철;김재철
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.82-88
    • /
    • 2013
  • IEC standards do not require to limit the earthing resistance of the concrete-embedded foundation earthing electrode which is installed to a specific value. However, in Korea the value of $5{\Omega}$ and below applies to the earthing resistance for a domestic customer whose receiving voltage is 22.9kV. This paper calculates the minimum area and volume of the concrete-embedded foundation earthing electrode in order to obtain a specific value of the earthing resistance when the electrode of the building's lightning protection system and that of its power system are interconnected. It also suggested the most appropriate method of installing the foundation earthing electrode, taking the electric characteristics of concrete into account.

수조모델 실험에 의한 접지저항 추정 (Estimation of Groungding Registance by Water Tank Model)

  • 최종규;고희석;이충식;김주찬
    • 조명전기설비학회논문지
    • /
    • 제17권2호
    • /
    • pp.41-48
    • /
    • 2003
  • 접지 시설의 효율적인 시설 계획을 위해서는 시공 전에 접지전극에 전류가 유입할 때 접지 전극주변에 발생하는 전위분포 및 전류에 의한 접지저항을 추정하는 것이 접지 설계에 있어서 매우 중요하다. 본 논문에서는 사각판상의 접지전극을 대지에 직접 시공 매설하여 지표면 전위의 분석으로 접지저항을 측정하고, 또한 사각판상 접지 저항 값의 이론적 계산식에서 구한 접지저항값과 축소된 사각판상의 접지전극 모델을 수조에 넣고 모의 실험을 통해 측정된 접지저항값을 비교·분석하였다.

지표면전위 해석에 의한 접지저항 측정기법에 관한 연구 (A Study on the Measurement of Grounding Resistance based on the Earth Surface Potential Analysis)

  • 윤장완;안용호;정길조;한병성
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.117-123
    • /
    • 2002
  • 접지저항의 측정은 접지계통의 접지성능이 적정한가를 평가하기 위한 가장 기본적이고 중요한 작업이라고 할 수 있다. 그러나 실제 현장에서, 특히 접지극의 크기가 큰 경우일수록 접지저항을 정확히 측정하기란 쉽지 않은데, 이는 정확한 접지전위 측정을 위한 기준전위 점을 찾기가 힘들기 때문이다. 본 논문에서는 접지극 주변에서 측정한 지표면전위를 분석하여 기준전위 점의 위치를 정확히 식별하는 방법과 그 정당성을 제시하였다.

현장실증시험에 의한 대지저항률별 접지저항 보정계수의 결정 (The Determination of Corrective Coefficient for Ground Resistance about Variation of Soil Resistivity by Field Test)

  • 심건보;김경철;이형수;박재덕;박상만
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.288-292
    • /
    • 2006
  • Usually, equations that calculate ground resistance of earth electrode was already informed well by form of earth electrode. But, when apply on the spot because general expressions are very insufficient at point that calculate exact ground resistance value by variation of earth electrode, and constant value that corrective coefficient for ground resistance calculation is fixed regardless of change of the earth resistivity specially is presented, it is actuality that difficulty is. Therefore, in this study, about these problem, proposed corrective coefficient for calculation of ground resistance according to change of the earth resistivity.

  • PDF

966nm 레이저 펄스를 이용한 바나듐 이산화물 박막 기반 전자 소자에서의 멤리스터 특성에 관한 연구 (Study on Memristive Characteristics in Electronic Devices Based on Vanadium Dioxide Thin Films Using 966nm Laser Pulses)

  • 김지훈;이용욱
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.59-65
    • /
    • 2015
  • By harnessing the thermal hysteresis behavior of vanadium dioxide($VO_2$), we demonstrated multi-resistance states in a two-terminal electronic device based on a $VO_2$ thin film by using a 966nm infrared laser diode as an excitation light source for resistance modulation. Before stimulating the device using 966nm laser pulses, the thermal hysteresis behavior of the device resistance was measured by using a temperature chamber. After that, the $VO_2$ device was thermally biased at ${\sim}71.6^{\circ}C$ so that its temperature fell into the thermal hysteresis region of the device resistance. Six multi-states of the device resistance could be obtained in the fabricated $VO_2$ device by five successive laser pulses with equal 10ms duration and increasing power. Each resistance states were maintained while the temperature bias was applied. And, the resistance fluctuation level was within 2.2% of the stabilized resistance and decreased down to less than 0.9% of the stabilized resistance 5s after the illumination.

고성능 필터를 이용한 접지저항 측정시스템의 설계 (Design of the Ground Resistance Measuring System using high Performance Filter System)

  • 이기홍;정재기;주형준
    • 조명전기설비학회논문지
    • /
    • 제15권6호
    • /
    • pp.43-48
    • /
    • 2001
  • 본 논문에서는 지중의 노이즈들로부터 영향을 받지않는 접지저항 측정시스템을 설계하였다. 일반적으로 기존 의 접지저항 측정기는 지중에 노이즈가 잠재되어 있을 경우, 접지저항 측정신호가 영향을 받아 정확한 접지저항을 측정하기 어렵다. 따라서 본 논문에서는 L-C공진필터와 마이크로프로세서를 이용하여 지중의 잡음환경에서도 정확히 접지저항을 측정할 수 있는 접지저항 측정기를 설계하였다. 또한 현장시험을 통해 설계된 접지저항측정기가 지중의 노이즈로부터 영향을 받지않음을 입증하였다.

  • PDF

Basic study on correction method of measured earthing resistance by 4-potential method

  • Saki, Ueta;Takehiko, Takahashi
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.53-56
    • /
    • 2008
  • The full of potential method is generally used for measuring the earthing-resistance. This method needs two auxiliary electrodes and it is required that two auxiliary electrodes are placed at enough distances from the earthing electrode, e.g. building foundation. However, in urban area there is not enough space for taking measurement. So, it is very difficult to measure the earth resistance precisely. However, there is the 4- potential method when it stand on the theory of the full of potential method. It is the purpose of this paper to basic study on correction method of measured earthing resistance by 4-potential method.

  • PDF

철근콘크리트 아파트의 철근구조체에 대한 전기적 연속성 평가 (Evaluation of Steelwork Continuity within Reinforced Concrete Apartment Structures)

  • 이기홍;이택섭;김언석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.125-127
    • /
    • 2005
  • This paper conducted to evaluate electrical continuity of steelworks within reinforced concrete apartment structures as the down conductor in external lightning protection system. The reinforcing bars in reinforced concrete structures can be used as the down conductor when their overall electrical resistance is not greater than the resistance value of 0.2 ohm between the uppermost part and the ground level. According to the results of electrical resistances measured by 4-terminal low resistance measurements, the steelworks in reinforced concretes structures exhibited the electrical continuity with low electrical resistance.

  • PDF

모형실험을 통한 모래지반에서 석션버켓기초의 관입저항력 평가 (Investigation on the Penetration Resistance of Suction Bucket Foundation in Sand using Model Test)

  • 김근수;권오순;오명학;장인성
    • 한국지반환경공학회 논문집
    • /
    • 제15권6호
    • /
    • pp.75-83
    • /
    • 2014
  • 석션버켓기초는 펌프로 버켓 내부의 물을 외부로 배출할 때 발생한 압력차로 지반에 설치되는 기초이다. 버켓기초는 외해의 플랫폼이나 석유 가스 시추시설을 계류시키기 위한 앵커로 주로 사용되었으나, 최근 유럽을 중심으로 해상풍력발전의 기초로 적용되기 시작하면서 국내에서도 큰 관심을 받고 있다. 석션버켓기초의 관입저항력 산정은 석션버켓기초를 성공적으로 시공하기위해 고려해야 할 주요 사항 중의 하나이다. 본 연구는 석션버켓기초를 관입시킬 때 필요한 관입력을 평가하기 위해 실내모형실험을 수행하였다. 실내모형실험은 압입설치 및 석션설치에서 측정한 관입저항력을 관입성능평가에서 많이 사용되는 기존의 이론식과 비교하여 강도감소계수의 적절한 범위를 검토하였다.