• Title/Summary/Keyword: Installation Cost

Search Result 1,175, Processing Time 0.032 seconds

Optimal configuration for underground power distribution system and its case study (국내 지중 배전계통의 부하특성별 최적계통 결정절차 및 사례검토)

  • Roh, Hwang-Nai;Cho, Seong-Soo;Park, Chang-Ho;Kim, Byung-Sook;Lee, Soo-Muk
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1450-1452
    • /
    • 1999
  • This paper presents the method of determination for optimal underground power distribution system in our country. To get optimal system, it is necessary to evaluate reasonably important factors such as installation cost, reliability index, customer interruption cost, convenience of installation and system flexibility. This study also described the new method which was applied to UI-San industrial park as a case study.

  • PDF

A Study of I/O Serial Communication Systems Between Overground And Overhead Controllers

  • Kim, Duk-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.122-128
    • /
    • 2007
  • This paper represents the Input/Output (I/O) serial communication methods between overground and overhead controllers using a programmable logic controller (PLC). In general, the systems composed by overground and overhead controllers use exclusive serial communication units. This, however, has a demerit such as a high cost as well as some restrictions of the system itself. Thus, this paper suggests methods by I/O cards for data communication between overground and overhead controllers. In this system, there is no special card and it therefore has a lower cost and is more flexible than the exclusive serial communication unit.

Development of Economic Evaluation of Indoor Lighting System (실내 조명시스템의 경제성 평가법 개발)

  • Cho, Sook-Hyun;Lee, Min-Wook;Choi, Hyeon-Seok;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.1
    • /
    • pp.8-14
    • /
    • 2012
  • An economic evaluation is required to reduce the cost of energy and lighting in the design of interior lighting. WEELS2011 is developed as a method of economic evaluation for LED lighting systems. Economic evaluation for fluorescent and LED lightings and after applying rebate to LED system is conducted using WEELS2011. The utilization and analysis of WEELS2011 are suggested for the reduction of energy and lighting cost.

Effects of reflective index of fiber sensor coil end on current measurement (광CT 센서코일 끝단의 반사율이 전류측정에 미치는 영향)

  • Park, Hyoung-Jun;Kim, Hyun-Jin;Song, Min-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.74-77
    • /
    • 2008
  • We improved an efficiency of fiber-optic current transformer by using a metal-coated sensor coil. To reduce the linear birefringence, we used a length of spun fiber as sensor coil, and then used a flint glass fiber coil for comparison. To make the sensor coil in the reflection type, we used different reflection mirrors at the end of the sensor coil, such as a Faraday rotator mirror, a simple mirror, a metal-coated fiber end and a simple fiber end. From the experimental results, the linear error of current measurements were less than ${\sim}$ 0.2 % regardless of the mirror types. The metal-coated sensor was the most cost-effective considering the fabrication cost and the simple structure.

  • PDF

A Study on Switched Reluctance Motor Driving using Commutator (정류자를 이용한 스위치드 릴럭턴스 전동기의 구동에 관한 연구)

  • Won, Sung-Hong;Han, Hak-Guhn;Jung, In-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.67-74
    • /
    • 2012
  • This paper presents the novel design and implementation of a switched reluctance motor with commutator. Unlike typical switched reluctance motor, this motor doesn't require semi-conductor devices and inverter circuits for driving. Instead, the brushes and commutator can make rotating field for driving the switched reluctance motor. Moreover, because this motor has no magnet, the total cost for manufacturing the motor is very cheap. In order to verify the usability of the proposed motor, the authors manufactured the prototype motor, and showed the torque-speed curve of the motor.

500VA Hybrid filter development for harmonic elimination of a single phase power (단상 전원의 고조파 제거용 500VA급 Hybrid 필터 개발)

  • Park, Jong-Yeon;Lee, Hu-Chan;Lee, Bong-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.249-253
    • /
    • 2006
  • Because of the high cost for the active power filter, passive filters have been widly used to absorb harmonic currents of nonlinear loads and can also improve the power factor. They are not often optimal filters because the passive filters are designed with the fixed load conditions. In this paper we proposed the method which only the necessary harmonic filters are operated by detecting the various harmonic current components. By the experimental results using the proposed system for the 500VA rectifier load, we concluded that the researched hybrid filter is cost effective and the performance is better than the passive filter.

  • PDF

A Study on the Electric System Design by the Forecasting of Maximum Demand (최대수요전력 예측에 의한 전기계통 설계에 관한 연구)

  • 황규태;김수석
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.1
    • /
    • pp.29-39
    • /
    • 1992
  • In this paper, the basic idea of optimum electric system design by means of the forecasting of maximum demand is presented, and the load characteristics and practical operating conditions are based on the technical data. After reconstruction of th model plant by use of above method, power supply reliability, future extention, initial cost, and running cost saving effects are analyzed. As a result, it is verified that the systems wherein the power is supply to each load frm main transformer whose capacity is calculated by forecasting are economic rather than the systems wherein the power is supply to each electric feeders from each corresponding transformer.

  • PDF

Symmetrical Cockcroft-Walton circuit for Transformerless High Step-Up DC-DC Converter (변압기 없는 고승압 직류 컨버터용 대칭형 Cockcroft-Walton 회로)

  • Cha, Dae-Joong;Baek, Ji-Eun;Ko, Kwang-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.70-75
    • /
    • 2015
  • High Step-up DC-DC Converters have been demanded for renewable energy applications. Transformer or coupled inductor is generally used to boost output voltage of converters. This methods can relatively obtain high voltage than others, whereas have heavy weight and high cost. To complement these disadvantages, we studied transformerless high step-up DC-DC converter. In various transformerless topologies, Boost converters combined with Cockcroft-Walton have studied. In this paper, we proposed a symmetrical Cockcroft-Walton circuit for transformerless high step-up DC-DC converter. Finally, we simulated proposed converter to compare with existing converter. As a result, proposed converter has higher duty ratio or lower cost than existing transformerless converters which are discussed in this paper.

An Analysis of Economy Improvement Method and Power Demand Effect when the Battery is Applied to the Building Based on the Measured Energy Consumption (전기저장장치의 건물수용가 적용에 따른 Demand영향 및 경제성 향상방안)

  • Yang, Seung-Kwon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.5
    • /
    • pp.86-93
    • /
    • 2015
  • Recently, ESS became efficient device to stabilize electric power supply system with the development SG related technology. In fact. there are some constraints to supply ESS, because of the high cost and required space, but rapid technology development for ESS will make it more useful soon. So, through this paper, we analyzed the benefit and demand effect when the battery is applied the building based on the measured energy consumption. After that, we got the conclusion that there is a volume limit in ESS application, in a benefit view point. And we realized that there is a demand violation, and the Cost-based BEMS is the best solution to enhance the effect of ESS application.

A Study on High Efficiency for Grid-connected Modular Photovoltaic Power Conversion System (계통 연계 모듈형 태양광 전력변환장치 고효율화에 관한 연구)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.36-44
    • /
    • 2014
  • The conventional central photo voltaic inverters have several problems. First, shadow problem in each solar panel, and high DC voltage problem from each panel because of concentration to one central inverter. Therefore, module integrated inverter is proposed to solve these problems. The inverter should be small and cost effective. The cost and size in the inverter depend on the inductor. So the switching frequency should be increased to reduce the inductor and total size, but there is a problem in efficiency because of the losses in turn-on and turn-off. In the paper, the critical conduction mode(CRM) switching method is adopted to reduce the switching loss and interleaving method is proposed to increase the efficiency in Flyback converter. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype system rated at 200W.