• Title/Summary/Keyword: Installation Cost

Search Result 1,175, Processing Time 0.03 seconds

Solar Photovoltaic According to Installation of Cooling System (냉각시스템에 의한 태양광 발전의 효율 개선)

  • Yum, Sung-Bae;Choi, Hong-Kyoo;Choi, Young-Jun;Hong, Seong-Goo;Kim, Tae-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.66-71
    • /
    • 2009
  • The solar photovoltaic power generator can get more power with the higher solar radiation quantity. However, if the higher solar radiation quantity on cell becomes high temperature, the efficiency of generate will be reduced. To install cooling system for this kind of device can be the way to solve high temperature problem on cell but another problems after install it such as increasing of solar generated quantity problem cost to install cooling system and cost to be maintained cooling system weren't discussed to practical use this system. So the present paper described about effect and commercial business possibility of cooling system. After installing a cooling system the results of experiment about 5.76[%] average annual increasing of solar photovoltaic can expect.

Solar photovoltaic according to installation of cooling system (냉각시스템 설치에 따른 태양광 발전)

  • Hong, Seong-Goo;Choi, Hong-Kyoo;Yoo, Hai-Chool;Lee, Chan-Jae;Han, Sang-Kwon;Kim, Tae-Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.189-192
    • /
    • 2008
  • The solar photovoltaic Power generator can get more power with the higher solar radiation quantity. However, if the higher solar radiation quantity on cell becomes high temperature, the efficiency of generate will be reduced. To install cooling system for this kind of device can be the way to solve high temperature problem on cell but another problems after install it such as increasing of solar generated quantity problem, cost to install cooling system and cost to be maintained cooling system weren't discussed to practical use this system. So the present paper described about effect and commercial business possibility of cooling system.

  • PDF

Understanding College Students' Perception of Green Building Products

  • Jung, Younghan;Jeong, Myung Goo;Considine, Carol
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.503-507
    • /
    • 2015
  • Sustainability continues to gain traction in all industry sectors as people become aware of the advantages of green products. The voluntary use of green products in buildings in the United States continues to grow due to long-term cost saving and the ecological benefit to nature. The voluntary installation of green products is associated with end-users' expectations and perceptions including cost saving, sustainable behavior, and social responsibility. Although involuntary use of green products has similar expectations and perceptions, the installation decision is not based on the goodwill from end-users. This paper surveys college students to capture current experience levels, expectations, and perceptions in regard to green products and/or sustainability and to understand their attitudes about involuntary use of a green product. The installation of low water pressure showerheads in a dormitory provides data to support perception, expectation, and future direction of adoption of green products in public buildings. This information may be used to facilitate sustainable behaviors among involuntary groups regarding to the adoption of green products. The primary objective of this paper is to investigate the college students' perception of a green product, particularly when the students are involuntarily exposed to the green products. As a secondary objective, the paper also attempts to address the college students' general understanding on sustainability and green products. The findings of this study could support the growing importance of sustainable behavior among higher education beyond social responsibility and provide a benchmark against which to improve future change while fostering sustainable behaviors over time among the public.

  • PDF

Design and Implementation of Automatic Installation System for PDA (휴대 정보터미널을 위한 애플리케이션 자동설치 시스템의 설계 및 구현)

  • 나승원;오세만
    • The Journal of Society for e-Business Studies
    • /
    • v.8 no.3
    • /
    • pp.165-176
    • /
    • 2003
  • Instead of existing cell phones, PDAs are observed as leading wireless Internet devices recently Numerous applications are developed by extended usage of PDAs and it should be installed appropriately according to devices. Furthermore, when battery is discharged, all data stored in RAM(Random Access Memory) becomes obsolete. So it should be recovered or reinstalled from flash memory, backup media or something. In this paper, we present an automatic application installation system(PAIS : PDA Automatic Installation System) to solve problems that users have to install applications by themselves whenever it is necessary. With this system, users feel comfortable by saving time and effort to install each applications and application development companies save cost needed to make materials illustrating installation process. Consequently PAIS may flourish wireless Internet business.

  • PDF

A Study on the Optimum Design of Axial Rotary Sensible Heat Exchanger for the Heat Recovery of Exhaust Gas (배기열(排氣熱) 회수용(回收用) 축류(軸流) 회전형(回轉形) 현열교환기(顯熱交換器)의 최적설계(最適設計)에 관한 연구(硏究))

  • Choi, Y.D.;Park, S.D.;Woo, J.S.;Tae, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.2
    • /
    • pp.131-141
    • /
    • 1991
  • A method of optimum design of an axial rotary sensible heat exchanger for the heat recovery of exhaust gas from the air conditioning space was developed in consideration of economics of investment cost and profit according to the installation of heat exchangers. Leakage rate of exhaust gas was calculated and the correlation for the pressure drop due to leakage of exhaust gas was proposed. Heat transfer between the matrix and exhaust and intake gas was analysed to calculate the effectiveness of heat exchanger, which was used for the optimum design of rotary heat exchanger. The results show that optimum rotational speed increases as the length of rotor increases and there exists optimum NTU which maximizes the gain of total cost according to the installation of rotary heat exchanger.

  • PDF

Application of the Worksheet for Economics Evaluation of Lighting Systems (조명시스템의 경제성 평가를 위한 Worksheet 적용)

  • Sim, Sang-Man;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.7-13
    • /
    • 2000
  • It is important to decide the best beneficial lighting system in the space when we design the lighting at first stage. A Worksheet to simplify the evaluation of the economics of the lighting system was developed. And it was applied to a general office room for each lamp and ballast combinations, and to a factory room with a high ceiling for each HID lamp systems. When we design the lighting system using the Worksheet, we can easily evaluate the economics through converting the total cost invested on the lighting system to the present value or the annual cost.

  • PDF

Improving Feed Value of Agricultural By-Products (농산부산물(農産副産物)의 사료화(飼料化))

  • Kang, Tae-Hong
    • Applied Biological Chemistry
    • /
    • v.27
    • /
    • pp.18-28
    • /
    • 1984
  • In order to improve feed values of Korean agricultural by-products, various treatments including physical, chemical, physicochemical and fermentation were suggested in th is review article. Physical treatments such as chopping, grinding and pelleting reduce partiole size of agricultural by-products, and increase passage rate from the rumen, thus may increase voluntary feed intake and weight gain. Digestibility and voluntary feed intake of straw, rice hull and sawdust, also, may be increased by chemical treatment using sodium hydroxide or ammonia. Especially, because nitrogen content of by-products increase and toxic problem is not posed by ammonia treatment, it's practical usage is recommended in Korea. Silage or fermentation treatment using principles of microbial fermentation may improve palatability of low quality by-products. As mentioned above, it is concluded that various treatments suggested are desirable and improve feed value but may raise several problems. Unfortunately, because cost for installation and products is great and processing work is complicate, farmers are not using well these processing methods until now. Therefore, in order to increase the practical usage at farm level, it is thought that many research works be achieved for efficient process which have simple operation and low installation cost.

  • PDF

Establishment of Preventive Maintenance Planning for Generation Facility Considering Cost (비용을 고려한 발전설비의 예방유지보수 계획 수립)

  • Kim, Hung-Jun;Shin, Jun-Seok;Kim, Jin-O;Kim, Hyung-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.328-333
    • /
    • 2007
  • Traditional maintenance planning is based on a constant maintenance interval for equipment life. In order to consider economic aspect for tm based preventive maintenance, preventive maintenance is desirable to be scheduled by RCM(Reliability-Centered Maintenance) evaluation. The main objective of RCM is to reduce the maintenance cost, by focusing on the most important functions of the system and avoiding or removing maintenance actions that are not strictly necessary. So, Markov state model is utilized considering stochastic state in RCM In this paper, a Markov state model much can be used for scheduling and optimization of maintenance is presented. The deterioration process of system condition is modeled by the stepwise Markov model in detail. Also, because the system is not continuously monitored, the inspection is considered. In case study, simulation results about RCM will be shown using the real historical data of combustion turbine generating unit in Korean power systems.

  • PDF

A Study on the Cost Effective DSM Method for Lighting Power Control through Pilot Test Based on Pre-Verified Methodologies (다양한 형태의 조명(형광등) 전력제어 실증시험을 통한 비용효과적인 전력수요관리방법 도출)

  • Yang, Seung-Kwon;Kim, Dae-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.7-13
    • /
    • 2013
  • The portion of lighting power consumption for our country is up to 20~30% of the total amount. Currently, most of the DSM(Demand side management) of lighting power is delivered in supply of high efficient lighting to customers. On the contrary, applications of lighting power to power load leveling are still rare. In this paper, the simulations for various control types of lighting power for load leveling are tried, and we obtained the cost effective and optimal control method through that. This simulation was executed in test office with fluorescent light by us based on applying 8 control types(on, off & dimming), considering customers' satisfaction, for instance, minimum intensity of illumination allowed. According to the result of this test, we found that mixed type(chessboard(on-off) plus dimming control(10%)) is most effective.

Evaluation for the Test Installation of Slab Track by Using Precast Concrete Panels (Precast Concrete Panel을 사용한 슬라브궤도 시험시공에 대한 평가)

  • Kim Soon-Cheol;Kong Sun-Yong;Kang Jeong-Ok;Lee Jong-Min;Han Kwang-Seob
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1071-1077
    • /
    • 2004
  • This paper is presenting the performance evaluation on the installed concrete panels. As a result of the evaluation, the resistance to track displacement of temporary support structure was improved and it resulted in the improvement of work stability during installation. And, by the application of new technology and the saving of concrete consumption, both workability and cost were improved and, therefore, the shorter project period and cost saving can be expected. Furthermore, as a result of noise & vibration measurement at site, it has shown good effects of anti-noise and anti-vibration. In conclusion, this process was proved as very effective for track improvement.

  • PDF