• 제목/요약/키워드: Inspection station

검색결과 137건 처리시간 0.025초

농어촌용수 및 농업생산기반시설의 실태조사에 따른 기후변화 영향 분석 (Analysis on the Impact of Climate Change on the Survey of Rural Water District and Agricultural Production Infrastructure)

  • 김수진;배승종;최진용;김성필;은상규;유승환;장태일;고남영;황세운;김성준;박태선;정경훈;송석호
    • 한국농공학회논문집
    • /
    • 제60권5호
    • /
    • pp.1-15
    • /
    • 2018
  • This study aims to effective survey on actual condition for impact and vulnerability assessment on climate change in agriculture and rural community (limited to rural water and agricultural infrastructure, Paragraph 3, Article 2 of the Rearrangement of Agricultural and Fishing Villages Act) entrusted to Korea Rural Community Corporation based on the Law (Paragraph 2, Article 47 of the Framework Act on Agriculture, Rural community and Food industry). The results are summarized as follows. The rural water was divided into three categories (abnormal climate, water use, and flood control), and 31 indicators were selected. The reservoirs were divided into four categories, and 20 indicators were selected. The pumping stations were divided into two categories, 7 indicators, and the drainage pump stations were divided into two categories, 5 indicators were chosen. A survey on actual condition of each indicator was conducted and the result of the impact assessment was calculated. The 65 rural water showed values ranged from 0.855 to 1.308. The reservoir ranged from 0.966 to 23.338 as a result of the impact assessment on the 16 indicators. The pumping station was able to calculate the results of the safety inspection and the thorough safety inspection, and the drainage pump station was able to calculate only the result of the safety inspection. It is judged that it will be necessary to secure and analyze data on indicators with no data in the future. The results of this research can be utilized as baseline data that can deal with climate change preemptively.

주요선진국 전파관리제도와 국내 전파관리 제도에 대한 조사 (Domestic Radio Waves Propagate Management and Control Systems Investigate the System Status)

  • 김성홍;석경휴
    • 한국전자통신학회논문지
    • /
    • 제12권1호
    • /
    • pp.1-8
    • /
    • 2017
  • 주요 선진국의 전파이용 관리 패러다임이 Command & Control ${\Rightarrow}$ Market Based ${\Rightarrow}$ Open Access ${\Rightarrow}$ Manage By Technology & Technical Analysis로 변화되고 있는데, 이는 다양한 신규 기술 서비스의 출현, 전파이용자의 급증 등 환경변화에 대한 정책대응과 시장활성화를 위함이다. 그러나 이러한 패러다임의 변화에도 혼간섭 등의 영향을 주지 않는 범위에서 전파를 이용해야 한다는 전파관리의 기본원칙은 준수되어야 한다. 전파유효 이용 및 혼간섭을 방지하기 위해 세계 각국은 자국에 적합한전파관리 규제를 법제화하고, 규율하고 있다.

ITU의 전파관리제도와 주요선진국 전파관리 사전 사후 규제에 대한 연구 (Study on the Radio Regulations of the ITU Radio Regulations institutions and developed countries before and after regulations)

  • 최우진;신현식
    • 한국전자통신학회논문지
    • /
    • 제11권6호
    • /
    • pp.553-560
    • /
    • 2016
  • 주요 선진국의 전파이용 관리 패러다임이 Command & Control $\Rightarrow$ Market Based $\Rightarrow$ Open Access $\Rightarrow$ Manage By Technology & Technical Analysis로 변화되고 있는데, 이는 다양한 신규 기술 서비스의 출현, 전파이용자의 급증 등 환경변화에 대한 정책대응과 시장활성화를 위함이다. 그러나 이러한 패러다임의 변화에도 혼간섭 등의 영향을 주지 않는 범위에서 전파를 이용해야 한다는 전파관리의 기본원칙은 준수되어야 한다. 전파유효 이용 및 혼간섭을 방지하기 위해 세계 각국은 자국에 적합한 전파관리 규제를 법제화하고, 규율하고 있다.

주택화재 예방을 위한 저소비 전력의 광전식 단독경보형감지기 개발에 관한 연구 (A Study on the Development of the Photo-electric Single Station Smoke Alarm of Low Power Consumption for Residential Fire Prevention)

  • 박세화;조재철
    • 한국화재소방학회논문지
    • /
    • 제24권1호
    • /
    • pp.46-53
    • /
    • 2010
  • 주택화재 예방을 위해 10년 동안 전지 교체 없이 지속적으로 유지가 되도록 회로 설계된 저소비 전력의 광전식 단독경보형감지기의 개발 경험을 보고한다. 시장규모가 국내에 비해 100배 이상 큰 일본을 대상으로 인증을 받도록 개발되었고, KFI 규격과 JFEII에 대한 시험 규격 비교 검토도 수행되었다. 감지기의 경보는 부저와 표시 LED를 통해 표현되며, 경보와 고장 및 화재 시의 동작 주기와 동작 시간이 기술되어 있다. 소비 전류를 줄이기 위해 적용된 주요 전자 회로 부분과 구현된 감지기의 동작 특성 분석 결과가 나타나 있다. 또한, 구현된 감지기의 소비 전류 측정값과 전지의 방전 특성 실험 결과를 통해 10년 동안 적용 가능함을 나타내었다.

자유 진동 실험을 통한 VRS-RTK 기법을 이용한 골조 구조물의 모니터링 적용성 검토 (Verification on the Application of Monitoring for Frame Structures Using the VRS-RTK Method through the Free Vibration Test)

  • 최세운;박효선;김법렬;이홍민;김유석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.174-182
    • /
    • 2014
  • 건물의 풍진동을 모니터링 하기 위해, 두 개 (이동국과 기준국)의 global positioning system (GPS)에 기반한 종래의 real-time kinematic (RTK) 기법이 널리 적용되고 있다. 그러나 이는 기준국을 위한 공간을 확보하거나 유지 관리하는데 어려움을 겪을 수 있다. 한편, 최근에 하나의 이동국 만을 이용하여 구조물의 움직임을 계측할 수 있는 새로운 virtual reference station (VRS)-RTK 기법이 개발되었으며, 측량 분야에서 널리 사용되고 있다. 본 연구에서는 골조 구조물의 횡방향 구조 응답을 모니터링하기 위한 VRS-RTK 기법의 적용성을 평가하기 위해 단층 골조 모형 (1차 고유진동수 : 1 Hz)과 3층 골조 모형 (1차 고유진동수 : 0.85 Hz)의 자유진동 실험을 수행하였다. GPS에 의해 계측된 변위 및 가속도 응답의 신뢰성을 평가하기 위해, 레이져 변위계와 가속도계가 설치되었으며, 이들로부터 얻은 계측값을 GPS의 계측값과 비교하였다. 또한, 건물의 지속적인 모니터링을 위한 적절한 계측 샘플링 수를 파악하기 위해, 변위 응답에서의 오차가 각기 다른 GPS 샘플링 수 (5, 10, 20 Hz)에서 평가되었다. 실험 결과, GPS으로부터 얻은 변위 및 가속도 응답은 레이져 변위계와 가속계로부터 얻은 응답과 좋은 유사 관계를 가지는 것을 확인하였다. 그리고, GPS 샘플링 수가 증가할수록 변위 오차는 감소하였으며, 3층 실험체에 대해서는 20 Hz의 GPS 샘플링 수로 구조물의 전 모드 성분 (1, 2, 3차 모드)을 검출할 수 있었다.

Verification of the Theoretical Model for Analyzing Dynamic Behavior of the PIG from Actual Pigging

  • Kim, Dong-Kyu;Cho, Sung-Ho;Park, Seoung-Soo;Park, Yong-Woo;Yoo, Hui-Ryong;Nguyen, Tan-Tien;Kim, Sang-Bong
    • Journal of Mechanical Science and Technology
    • /
    • 제17권9호
    • /
    • pp.1349-1357
    • /
    • 2003
  • This paper deals with verification of the theoretical model for dynamic behavior of Pipeline Inspection Gauge (PIG) traveling through high pressure natural gas pipeline. The dynamic behavior of the PIG depends on the differential pressure across its body. This differential pressure is generated by injected gas flow behind the tail of the PIG and expelled gas flow in front of its nose. To analyze the dynamic behavior characteristics such as gas flow in pipeline, and the PIG position and velocity, not only the mathematical models are derived, but also the theoretical models must be certified by actual pigging experiment. But there is not any found results of research on the experimental certification for dynamic behavior of the PIG. The reason is why the fabrication of the PIG as well as, a field application are very difficult. In this research, the effectiveness of the introduced solution using the method of characteristics (MOC) was certified through field application. In-line inspection tool, 30" geometry PIG, was fabricated and actual pigging was carried out at the pipeline segment in Korea Gas Corporation (KOGAS) high pressure system, Incheon LT (LNG Terminal) -Namdong GS (Governor Station) line. Pigging is fulfilled successfully. Comparison of simulation results with experimental results show that the derived mathematical models and the proposed computational schemes are effective for predicting the position and velocity of the PIG with a given operational conditions of pipeline.

철도차량용 제륜자의 자동 검사 시스템 (Automated Inspection System for Brake Shoe of Rolling Stock)

  • 김현철;김회율
    • 대한전자공학회논문지SP
    • /
    • 제46권6호
    • /
    • pp.1-15
    • /
    • 2009
  • 본 논문에서는 이동 중인 철도차량 제륜자의 두께, 편마모 및 제륜자와 차륜 사이의 거리를 자동으로 측정하는 시스템을 제안한다. 철도차량의 제륜자는 촬영 시스템이 설치된 곳을 지날 때 자동으로 촬영되며, 두께 등을 측정하기 위해 가장 먼저 영상 내에서 제륜자의 위치를 검출한다. 이는 제륜자의 위치가 영상 마다 다르기 때문이며 이를 적응적으로 찾기 위해, 제륜자와 차륜 사이에 나타나는 그림자 영역을 이용한다. 그림자 영역의 경계는 9차 다항식을 통해 모델링되며, 그 영역을 지나는 임의의 곡선 (초기 곡선)은 제약 곡선 피팅 방법을 통해 검출된다. 다음은 검출된 초기 곡선과 명암도 변화 정보를 이용하여 제륜자의 앞과 뒤, 차륜 상의 세 곡선 및 제륜자의 수직면을 지나는 직선을 검출한다. 최종적으로, 앞서 구한 곡선과 직선을 이용하여 제륜자의 두께, 편마모 및 제륜자와 차륜 사이의 거리를 측정한다. 실험에서는 제안된 방법을 실제 선로에서 촬영한 영상에 대해 적용해 보았으며, 그 결과 평균 0.654mm의 두께 측정 오차를 나타내었다.

국내 전파관리 제도 개선을 위한 미국의 전파관리규제에 대한 연구 (A Study on Radio Wave Management Regulations in the United States to Improve the Domestic Radio Wave Management System)

  • 윤찬호;석경휴
    • 한국전자통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.379-388
    • /
    • 2020
  • 현행 무선업무 및 무선국 분류체계의 문제점을 분석하고, 미국의 전파관리 사례를 조사하여 합리적이고 효율적인 전파관리 방안을 마련하는 것이 본 연구의 내용 및 범위이다. 본 연구결과를 전파법 시행령, 무선업무 및 무선국종 분류기준 등에 관한 법제도 개정 시 기초자료로 활용할 수 있다. 향후 새로운 무선업무/무선국의 정의 및 분류체계에 대한 상세한 해설집을 마련하여 실무에서의 정책 순응도를 높이는 한편, 무선국 허가·검사 업무의 정합성 및 효율성 제고에 기여할 수 있을 것으로 기대된다.

LPG 잔류물질의 성분 및 조성 분석 (The Component and Compositional Analysis of Trace Materials in LPG)

  • 김영구
    • 대한화학회지
    • /
    • 제46권4호
    • /
    • pp.317-323
    • /
    • 2002
  • 국내에서 유통되고 있는 LPG중의 잔류물질을 분석하였다. 시료 채취 장소는 LPG용기 재검사장의 용기 2곳, LPG집단공급시설 기화기 6곳 및 LPG충전소의 압축기 오일 1곳이었다. LPG용기재검사장의 용기내 잔류물질의 성분은 alkene, diene계통의 물질(탄산소$\leq$9), 방향족 탄화수소와 타르성 화학물질 (탄소수$\geq$10)으로서 각가 1.5∼39.9%, 0.7%, 57.8∼96.0%이었다. 반면에 LPG집단공급시설의 잔류물질 및 LPG 충전소 오일 중의 타르성 화학물질은 96.6%이상이었다. 채취한 9가지 시료는 3가지 군집으로 분류되었다. SE사 용기 재검사장 시료 (SE사 시료와 S사 LPG 용기 재검사장 시료와의 유클리디안 RMS 거리=2.11), S사 LPG용기재검사장 시료 (집단공급시설시료 군과의 유클리디안 RMS거리=0.110), 집단공급시설 시료군(유클리디안 RMS거리〈0.075)이다. LPG 집단공급시설 시료의 성분이 LPG충전소 압축기오일의 조성과 매우 유사하고, 충전소 오일의 밀도와 집단공급시설의 시료 밀도가 각각 0.873, 0.873 $\pm$0.00798 (99% 신뢰구간)인 것으로 보아 타르성 화학물질은 LPG유통과정의 압축기 오일로부터 유입한 것으로 추정한다

원적외선 건조온도에 따른 백삼의 주근과 세근의 이화학적 특성 (Physicochemical Characteristics on Main and Fine root of Ginseng Dried by Various Temperature with Far-Infrared drier)

  • 이가순;김관후;김현호;성봉재;이희철;이용구
    • 한국약용작물학회지
    • /
    • 제16권4호
    • /
    • pp.211-217
    • /
    • 2008
  • 수삼을 주근 및 세근으로 분리하여 원적외선건조기를 이용하여 건조온도(70, 80, 90, 100, 110, 120, 130 및 $140^{\circ}C$)에 따라 건조한 후, 사포닌, 당, 유기산 및 색도를 분석하였다. 건조한 주근의 총사포닌 함량은 건조온도가 높을수록 미량 증가하여 $130^{\circ}C$에서 가장 높았고 세근에서는 온도가 증가할수록 감소하였다. 세근에서 온도가 증가할수록 급격하게 감소한 ginsenoside는 Re, Rc, Rb1 및 Rb2 이었고 Rg1, Rg3, Rf 및 Rb3는 미량씩 증가하였다. 가용성 당은 주근, 세근 모두 $70^{\circ}C$에서 가장 많이 용출되었고, 유기산 함량은 주근 세근 모두 $120^{\circ}C$에서 가장 많은 함량을 보였다. 건조온도에 따른 색도는 온도가 증가할수록 밝기는 주근 세근 모두 감소하였고 적색도는 온도가 증가할수록 높아져서 $120^{\circ}C$에서 가장 높았고 황색도는 $100^{\circ}C$에서 가장 높았으며 그 이상의 온도에서는 감소하는 경향이었다. 따라서 수삼 건조 시 건조온도에 따라 사포닌 구성함량 변화의 차이를 보임으로서 백삼의 이용목적에 맞게 수삼 건조 시 온도, 건조 형태 및 주근과 세근을 분리하여 건조하는 방법을 이용하는 것이 바람직할 것으로 생각된다.