• Title/Summary/Keyword: Inspection bodies

Search Result 34, Processing Time 0.025 seconds

Iron supplement tablet embedded in the oral cavity mimicking neoplasm: a case report

  • Corliano, Fabrizio;Falco, Paola;Cambi, Jacopo;Brindisi, Leopoldo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.2
    • /
    • pp.111-114
    • /
    • 2016
  • The detection of foreign bodies in the upper-aerodigestive tract is a fairly frequent event and can occur in various areas and for various reasons. In rare cases, foreign bodies can simulate a neoplasia. We evaluated similar cases during emergency regimen with an oral cavity mucosal lesion, causing lockjaw, sore throat, dysphagia, and swelling of the submandibular and laterocervical region. Physical examination revealed an extensive mucosal ulceration in the floor of the mouth and the lateral surface of the tongue, comparable to oral cancer. During a second, more accurate assessment, a partially deteriorated iron supplement tablet was found embedded in a mucosal pocket. After removing the tablet, gradual normalization of the tissue was observed without any sequelae. This is one of the many reasons why it is advisable and useful in cases of oral lesions to collect a detailed medical history and to perform an accurate clinical evaluation, including inspection and palpation of the lesion, before proceeding to further diagnostic assessments, especially in elderly patients taking many medications. However unlikely, it is possible that difficulty in swallowing pills or tablets could generate tumorlike lesions.

Quality Assurance Experience in Korea

  • Lee, Jone-Chan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.4 no.1
    • /
    • pp.23-29
    • /
    • 1984
  • This paper describes the evolution of quality assurance in Korea from it's total reliance on foreign contractors to the present status of conducting all QA functions independently. A brief status of the Republic of Korea Regulatory Bodies, licensing precess, codes and standards, and the quality organization of the Korea Electric Power Corporation are also included.

  • PDF

Sequential hepatic ultrastructural changes and apoptosis in rabbits experimentally infected with Korean strain of rabbit hemorrhagic disease virus (RHDVa) (국내 분리 토끼출혈병 바이러스(RHDVa)를 감염시킨 토끼 간장에서의 경시적인 초미세구조 변화와 apoptosis)

  • Park, Jung-Won;Chun, Ji-Eun;Bak, Eun-Jung;Kim, Han;Lee, Myeong-Heon;Hwang, Eui-Kyung;Kim, Jae-Hoon;Lee, Chung-Bok;Woo, Gye-Hyeong
    • Korean Journal of Veterinary Research
    • /
    • v.53 no.1
    • /
    • pp.11-17
    • /
    • 2013
  • In this study, to understand the pathogenesis of new rabbit hemorrhagic disease virus (RHDVa) serotype, we carried out to administrate RHDVa to rabbits, and to examine sequential electron microscopic changes and relationship between pathogenesis and apoptosis. TUNEL-positive cells began to be observed from 24 hours after inoculation (HAI) and the number of positive cells was slightly increased with the course of time. Whereas marked increase of positive cells was seen in the liver from the rabbits died acutely. Typical viral particles with cup-like projections and a diameter of 30~40 nm were detected in homogenized liver samples and tissues at 36 and 48, and 48 HAI, respectively. Ultrastructurally, glycogen deposition was observed from the first stage of hepatocellular degeneration by RHDVa infection and then, swelling and disruption of cristae of mitochondria by viral particles, swelling of smooth endoplasmic reticulum, vacuoles and vesicles were detected. Condensation, margination and fragmentation of chromatin were observed in degenerative hepatocytes at 36 and 48 HAI, indicating apoptotic bodies. These data offer that hepatocytic apoptosis by RHDV infection could be closely related with mitochondrial impairment in the hepatocytes.

A Study on the Analysis of Current Situation of Safety Inspections cost in Apartment houses (공동주택 안전점검대가 현황분석에 관한 연구)

  • Go, Seong-Seok;Song, Do-Heom;Yun, Yeong-Chae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.2
    • /
    • pp.62-70
    • /
    • 2014
  • An apartment house, a private facility, is a house built for many persons to live independently in a building. An apartment house is a building where life damage can happen most in case of a safety accident due to insufficient inspections. However, formal inspections are being realized due to awareness shortage of managing bodies about safety inspection and low-price order-receiving of diagnosing enterprises via the lowest bidding method. This is because it is judged that remarkable costs are inputted in repairs and reinforcement such as maintenance of a structure and that there is a large possibility of human damage in case of a safety accident in a structure. So, this paper aims to derive the points to improve in the current criterion to execute an efficient detailed inspection. As its method, the design price and execution price situation of 66 buildings inspected in detail for recent 3 years for the class 2 facilities in Gwangju Metropolitan City and Jeonranam-do are examined and analyzed. The state2 object buildings to inspect are selected through this. And this paper aims to present the points to improve through the analysis of current problems by evaluating the detailed inspection report and the detailed inspection execution price calculation criterion for the selected 10 apartment houses.

Study for confidence security of certification of management system and validity examination (경영시스템 인증의 신뢰성 확보 및 유효성 심사에 관한 연구 -ISO 9001 인증을 중심으로-)

  • Lee, Eun-Sook;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.127-135
    • /
    • 2009
  • In today's society it is often required to state objectively conformity of products (including services) to specified requirements. Conformity assessment bodies (CABs). can objectively state such conformity. These CABs perform conformity assessment activities that include certification, inspection, testing and calibration. A system to accredit CABs conformity assessment services should provide confidence to the purchaser and regulator. Certification of management system is one of means of providing assurance that the organization has implemented a system for the management of the relevant aspects of its activities, in line its policy.

Effect of Metals used in Orthopedic on Magnetic Resonance Imaging I (정형보철용 금속이 자기공명영상에 미치는 영향 I)

  • Kim, Hyeong-Gyun;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.46-50
    • /
    • 2012
  • Stainless steel and titanium used for orthopedic prosthetic metal, magnetic resonance imaging was measured quantitatively the extent of distortion. Based on reading tests at varying metal magnetic resonance imaging (MRI) were investigated. To two image acquisition conditions for having three metal bodies mutually quantitative it compared analyzed the image of cross direction and the image of lengthwise. As for the distortion of the magnetic resonance image, as for the distortion of image it became small in the order of Clip, Strainless and Titanium. In addition, with T1WI and T2WI which are image acquisition condition T2WI the distortion of image became small. As for the distortion of the image by the metal, you could see the distortion of image in elliptical shape, the metal a bigger image distortion appeared in many parts. If clinical doctor has the condition of the same operation, use the Titanium material, it can, raising the diagnostic value of magnetic resonance image inspection after the operating from Stainless.

Subtalar Arthroscopy (거골하 관절의 관절경술)

  • Ahn, Jae-Hoon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.235-241
    • /
    • 2009
  • The development of good quality small-diametered arthroscopes and refined arthroscopic techniques has contributed to the improvement of the subtalar arthroscopy. The therapeutic indications are synovectomy, removal of loose bodies, debridement and drilling of osteochondritis dissecans, excision of subtalar impingement lesions and osteophytes, lysis of adhesions for post-traumatic arthrofibrosis, removal of a symptomatic os trigonum, calcaneal fracture assessment and reduction, and arthroscopic arthrodesis of the subtalar joint. The subtalar arthroscopy can be done in supine position using thigh holder or in lateral decubitus position. The arthroscope generally used is a 2.7-mm 30 degrees short arthroscope. Noninvasive distraction with a strap around the hindfoot can be helpful. Usually anterolateral, middle and posterolateral portals are utilized for inspection and instrumentation within the joint. Twoportal posterior subtalar arthroscopy in prone position can be performed as well with 4.0-mm 30 degrees arthroscope, depending on the type and location of the subtalar pathology. The subtalar arthroscopy is a technically demanding procedure, which requires proper instrumentation and careful operative technique. Possible complications are nerve damage and persistent wound drainage.

  • PDF

Study on the Necessity and Specific Recommendations for Enhancing the Legal Requirements for Underwater Recreational Vessel Propeller Guards (수중레저선박 스크류망 제도개선의 필요성과 구체적인 제안)

  • Jung-Soo Lee;Jeong-Tack Min;Ho-Yun Jang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.2
    • /
    • pp.226-232
    • /
    • 2024
  • During scuba diving in Korea, accidents involving bodies being struck by the ship propeller when entering and exiting the water, repeatedly occur every year. In response to the need to reduce accidents and implement safety management measures, Korea has established regulations for the installation and management of propeller guards. However, owing to the absence of clear production regulations in domestic laws and regulations, the installation standards are ambiguous, and the inspection items are limited to the appearance and fixation status. As a result, the safety of divers in propeller accidents is not guaranteed. Therefore, this study was conducted to specify the current legal requirements for the installation and inspection of propeller guards. To achieve this goal, we conducted a thorough analysis of the current state of domestic and foreign propeller guards and the legal factors pertaining to safety standards. Based on this analysis, we identified specific areas for improvement and proposed a plan to enhance the system for installation and inspection. The installation standards for propeller guards were clearly outlined in terms of the lattice size and material. Additionally, inspection standards were proposed for appearance, fixation, and material condition, along with clear indicators for assessing them.

Automatic Detection of Foreign Body through Template Matching in Industrial CT Volume Data (산업용 CT 볼륨데이터에서 템플릿 매칭을 통한 이물질 자동 검출)

  • Ji, Hye-Rim;Hong, Helen
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.12
    • /
    • pp.1376-1384
    • /
    • 2013
  • In this paper, we propose an automaticdetection method of foreign bodies through template matching in industrial CT volume data. Our method is composed of three main steps. First,Indown-sampling data, the product region is separated from background after noise reduction and initial foreign-body candidates are extracted using mean and standard deviation of the product region. Then foreign-body candidates are extracted using K-means clustering. Second, the foreign body with different intensity of product region is detected using template matching. At this time, the template matching is performed by evaluating SSD orjoint entropy according to the size of detected foreign-body candidates. Third, to improve thedetection rate of foreign body in original volume data, final foreign bodiesare detected using percolation method. For the performance evaluation of our method, industrial CT volume data and simulation data are used. Then visual inspection and accuracy assessment are performed and processing time is measured. For accuracy assessment, density-based detection method is used as comparative method and Dice's coefficient is measured.

Development of Steel Wire-Integrated Deck Plate Applicable to Slab with 180mm Thickness (두께 180mm 슬래브에 적용 가능한 철선일체형 데크 플레이트 개발)

  • Lee, Yong Jae;Yoon, Sang Chun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.89-98
    • /
    • 2012
  • A steel wire-integrated deck plate that welds integrated triangle truss steel wires on a galvanized steel sheet is developed to reduce construction costs of slabs or formworks such as shores and supports, and it is already widely applied in many construction fields. In this research, experimental tests for 14 full scale specimens, which are in the same field conditions, are conducted on several parameters such as the diameter of top, bottom and lattice steel wire, cutting methods of ends. According to the result, changes in final destruction types of the test bodies and cutting methods of ends didn't affect structural performance of test specimens, and for a 4.0m-span test specimen, there was no big problems in using bottom bar D7 or D8.