• Title/Summary/Keyword: Inside outside test

Search Result 245, Processing Time 0.028 seconds

A Study on Customer's Satisfaction and Intention in Multiplex Theater (멀티플렉스영화관에서의 고객만족과 고객의도에 관한 연구)

  • Chang Kyung;Ko Hyun-Min
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.28 no.2
    • /
    • pp.1-7
    • /
    • 2005
  • Today, it can not be denied that customer's satisfaction is one of the most important key factors for business success. This paper studies relationships between customer's satisfaction and intention in multiplex, where customer satisfaction means several kinds of the satisfaction of both facility and personnels inside and outside multiplex while the intention means that customer has the intention that he/she will revisit, inform by word of mouth, and stay at multiplex in the future. The number of subjects In this study is 346 persons stayed at four multiplexes, among which we obtained valid responses from 326 persons through questionnaire investigation. We held hypotheses for the relationships, and for the testing, used methods are Spearman's correlation, Mann-Whitney test, etc, and for statistical analysis, SPSS 10.1 software was used. Thus, we found statistically significant results. The relation between customer's satisfaction and his/her favorable intention is positive. With the information given in this paper we can notice which kind of satisfaction is highly related to each intention of customer, so that multiplex can be operated more effectively toward high revenue.

Commercial Production of Seed Garlic by Tissue Culture Technique (조직배양에 의한 씨마늘의 상업적 생산)

  • NAM Sang-Il;PARK Ju-Hyun;CHOI Jong-In;KWON Ki-Seok;UHM Jeong-Sik
    • Proceedings of the Korean Society of Plant Biotechnology Conference
    • /
    • 2002.04a
    • /
    • pp.33-40
    • /
    • 2002
  • We, Tong Yang Moolsan Co. Ltd. (TYM) set up the mass-production system for virus-free seed garlic via tissue culture technique. TYM's tissue culture technique is called as 'Multiple shoot propagation technique'. This technique can lead mass propagation of genetically homogeneous seed garlic in a short period because of its highly proliferation rate of in vitro shoots ($15^{10}$ /year). TYM researchers applied the technique to some selected garlic cultivars with superior characteristics and carried out field test of productivity in the inside and outside of the country for several years. According to the yearly results of field test with virus-free seed garlic, we ascertained that virus-free seed garlic can produce the highly yield increase (max. above $50\%$) and also can enhance the product quality. Consequently, we estimated that TYM's seed garlic will contribute to farmers with increase of income and can elevate the national position of garlic market in the world for its competitive power of technical and production cost.

  • PDF

Effect of Artificial Aeration System on Water Quality of Yeoncho Lake (연초호의 인공 순환 장치 운영에 의한 수질 개선 효과 분석)

  • Seo, Dong-Il;Hwang, Hyun-Dong;Lee, Eun-Hyoung;Heo, Woo-Myung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.357-365
    • /
    • 2004
  • Effect of artificial circulation on amelioration of water quality in Yeoncho Lake was analyzed using summer data between 1991-2002. Two sites, intake tower area where aeration systems are concentrated in and near the inlet of reservoir were selected for comparison in this study. Summer averages between may and september Showed that aeration system might be beneficial in the improvement of water quality of BOD5, COD, and TN while Chl-a concentration and transparency did show opposite pattems. Wilcoxon's singed rank test for matched pair indicated slight increase of BOD5 and COD concentrations in the vicinity of intake tower while other variables did not show any significant differences from data of inlet of reservoir. During the study, it was found that the following subjects need to be investigated for more detailed analysis. 1) Dynamic pollutant loading from outside and inside the lake, 2) Biological, Chemical and Physical lake data when aeration systems are in and not in operation and 3) Radius of influence of aeration system.

Optimizing the maximum reported cluster size for normal-based spatial scan statistics

  • Yoo, Haerin;Jung, Inkyung
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.4
    • /
    • pp.373-383
    • /
    • 2018
  • The spatial scan statistic is a widely used method to detect spatial clusters. The method imposes a large number of scanning windows with pre-defined shapes and varying sizes on the entire study region. The likelihood ratio test statistic comparing inside versus outside each window is then calculated and the window with the maximum value of test statistic becomes the most likely cluster. The results of cluster detection respond sensitively to the shape and the maximum size of scanning windows. The shape of scanning window has been extensively studied; however, there has been relatively little attention on the maximum scanning window size (MSWS) or maximum reported cluster size (MRCS). The Gini coefficient has recently been proposed by Han et al. (International Journal of Health Geographics, 15, 27, 2016) as a powerful tool to determine the optimal value of MRCS for the Poisson-based spatial scan statistic. In this paper, we apply the Gini coefficient to normal-based spatial scan statistics. Through a simulation study, we evaluate the performance of the proposed method. We illustrate the method using a real data example of female colorectal cancer incidence rates in South Korea for the year 2009.

Control and Monitor of Heat Exchange Ventilation Facility by Smart Phone (스마트폰을 이용한 열교환기 환기장치의 제어 및 계측)

  • Chung, Myung-jin;Lee, Jin-ho;Hong, Jong-sung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1027-1029
    • /
    • 2015
  • Heat exchange ventilation facility is using for heating the inflow outside-air with warm outflow inside-air. Energy cost is saved and respiratory disease caused by temperature difference of air is prevented. In this paper, system for remote control and monitoring of heat exchange ventilation facility is developed. This system is applied in chicken breeding farm, and verification test of performance such as temperature and humidity control and monitoring is conducted. From verification test, temperature control error is measured as under 2degrees around the chicken breeding farm.

  • PDF

Development of a Groundwater Sampler and Test in a Well Affected by Seawater Intrusion (지하수 샘플러 개발 및 해수침투 관측정에서의 평가)

  • Lee, Bong-Joo;Moon, Sang-Ho;Kim, Gee-Pyo;Kim, Yong-Cheol;Kim, Yong-Je;Koh, Gi-Won
    • The Journal of Engineering Geology
    • /
    • v.18 no.3
    • /
    • pp.331-338
    • /
    • 2008
  • A new ground water sampler was developed and evaluated for target depth sampling under most rigorous field conditions. This new concept sampler comprises an air-cylinder, a hypodermic needle and a sampling bottle. Pressurized air or nitrogen gas can be used as a mechanical power source to operate the sampler. The air-cylinder is used to jab the hypodermic needle into the rubber cap of the sampling bottle. The hypodermic needle functions as a pathway to inject groundwater into the sampling bottle. Field test was conducted in a seawater intrusion monitoring well located at Handong district of Jeju Island. Water qualities in this well are periodically changed from the effects of sea water. Water sampling fir the same target depth in this well were tried at various times, and variations in electrical conductivity and pressure at the inside and outside of the sampler were measured using CTD divers. We found that the device could collect water samples only when it was actuated, and the pattern and range of variations in electrical conductivities and pressures measured at the inside and outside of the sampler were nearly identical. These results indicate that water samples using the sampler presented in this study represent correctly water qualities in which the samplings were made at a specific target depth in a well.

The Development of Performance Test Equipment For Evaluating Endothermic Performance of Fuel Supply and Cooling System in High-Speed Vehicles (고속비행체 연료 공급 및 냉각 계통의 흡열성능 평가를 위한 성능시험 장치 개발)

  • Kim, Minsang;Choi, Won;Jun, Pilsun;Park, Jeongbae
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.4
    • /
    • pp.43-49
    • /
    • 2019
  • In this study, a test equipment which enables to feed endothermic fuel which is heated in the inside and outside environment of a high-speed vehicle and evaluate the heat exchangers' performance was designed and manufactured. For smooth operation of the test equipment, a test procedure that supplied endothermic fuel at high temperatures was established. The catalyst performance test was conducted based on the supply condition of the endothermic fuel and the amount of heat absorbed was analyzed. The validation of the test equipment was proved by comparing the results of catalytic reaction with the previous studies under similar reaction condition. This test equipment can be utilized in the endothermic reaction tests of catalyzed endothermic fuel under various conditions.

Research on the Location Decision of Korea Land Spatialization Program's Test-bed (지능형국토정보기술 테스트베드 입지선정에 관한 연구)

  • Song, Ki-Sung;Park, Ji-Man;Lee, Jung-Hun;Kim, Byung-Guk
    • Journal of Korea Spatial Information System Society
    • /
    • v.11 no.4
    • /
    • pp.1-8
    • /
    • 2009
  • The Korean Government recognized that the importance of spatial information market is promoting Korean Land Spatialization Program(KLSP) to commercialize and practice of the technology. For achieve this purpose, KLSP is planning to build test-bed for field test, integration, display of outcomes. The most important problem in this process is reasonable decision of location. In this paper, the subject is to find how to decide efficiently in locating facilities to test Geospatial information technology like KLSP Test-bed. Consequently, we look over some cases of the inside and outside of the country, and analyze property of outcomes to apply the test-bed. And then we find assessment items for locating.

  • PDF

Analysis of Cooling Effect on the Plastic Film Cover of Greenhouse Module Depending on the Shade and Water Curtain (온실지붕 차광과 수막 수준에 따른 냉방효과 분석)

  • Kim, Young-Bok;Park, Joong-Chun;Lee, Seung-Kyu;Kim, Sung-Tae;La, Woo-Jung;Huh, Moo-Ryong;Jeong, Sung-Woo
    • Journal of Bio-Environment Control
    • /
    • v.15 no.4
    • /
    • pp.306-316
    • /
    • 2006
  • In this study, the effect of the shade level, water flow rate applied to the shades and the temperature of water on the greenhouse cooling was investigated depending on the shade level of 0, 35, 55, 75%, and water flow rate and water temperature by the test on the small wooden frames to find out the low cost cooling method. With increasing of the dry bulb temperature of outside air, the dry bulb temperature in the wooden frames increased. For the frames with the shade and water, inside temperatures of the frames were lower of -0.2$\sim$-1.2$^{\circ}C$ than the temperature of the outside air and higher than the water temperature. For the frames without water, inside temperatures of the frames were higher of 1.7$\sim$4$^{\circ}C$ than the outside and not affected by the shade level very much. The water flow rate and the temperature of the water were not the important factors to decrease the inside temperatures in the frames. The black globe temperature became lower with increasing of shade level. The shade frames with water curtain showed the best cooling effect because of reducing thermal radiation and cooling the plastic film cover. The surface temperatures of the plastic film cover for the water supplied modules became lower with increasing of the shade level. The relative humidity was decreased with the dry bulb temperature in the frame increasing and not affected by the dry bulb temperature of the outside air for the frames with the shade and water.

Heat Transfer in the Passive Containment Cooling System (수동형 격납용기 냉각계통에서의 열전달)

  • Cha, Jong-Hee;Jun, Hyung-Gil;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.281-291
    • /
    • 1995
  • The objective of this work is to obtain the experimental data for the heat transfer processes occurring both on the inside and outside surfaces of containment steel wall with dry and wet outer surface conditions in the passive containment cooling system. The test model represented a 60$^{\circ}$ section of a containment vessel based on the AP 600 geometry. Major linear dimensions of the test model ore reduced tv a factor of ten. To simulate the decay heat a steam generator heated by electricity was placed in the test model. The maximum heat flux was 8.91 kW/$m^2$. Two types of tests were performed. The one was the tort on the natural convection of air without water film flow. The other was the evaporative heat transfer test with the falling water film flow and natural air draft. no test result shooed that the heat transfer capability by the natural convection from the containment to the air without oater film flow was limited at about 1.48 kW/$m^2$ heat flux. It was found that the heat removal capability was remarkably enhanced in the tests with the waster film flow and air draft. The obtained heat transfer data ore compared with the existing correlations.

  • PDF