• Title/Summary/Keyword: Insertion Force

Search Result 139, Processing Time 0.023 seconds

A Study on Pressure Distribution for Uniform Polishing of Sapphire Substrate

  • Park, Chul jin;Jeong, Haedo;Lee, Sangjik;Kim, Doyeon;Kim, Hyoungjae
    • Tribology and Lubricants
    • /
    • v.32 no.2
    • /
    • pp.61-66
    • /
    • 2016
  • Total thickness variation (TTV), BOW, and surface roughness are essential characteristics for high quality sapphire substrates. Many researchers have attempted to increase removal rate by controlling the key process parameters like pressure and velocity owing to the high cost of consumables in sapphire chemical mechanical polishing (CMP). In case of the pressure approach, increased pressure owing to higher deviation of pressure over the wafer leads to significant degradation of the TTV. In this study, the authors focused on reducing TTV under the high-pressure conditions. When the production equipment polishes multiple wafers attached on a carrier, higher loads seem to be concentrated around the leading edge of the head; this occurs because of frictional force generated by the combination of table rotation and the height of the gimbal of the polishing head. We believe the skewed pressure distribution during polishing to be the main reason of within-wafer non-uniformity (WIWNU). The insertion of a hub ring between the polishing head and substrate carrier helped reduce the pressure deviation. Adjusting the location of the hub ring enables tuning of the pressure distribution. The results indicated that the position of the hub ring strongly affected the removal profile, which confirmed that the position of the hub ring changes the pressure distribution. Furthermore, we analyzed the deformation of the head via finite element method (FEM) to verify the pressure non-uniformity over the contact area Based on experiment and FEM results, we determined the optimal position of hub ring for achieving uniform polishing of the substrate.

A Finite Element Analysis of Stress Distribution in the Temporomandibular Joints Following the Teeth Loss (치아결손이 측두하악관절의 응력분포에 미치는 영향에 관한 유한요소법적 분석)

  • Woo-Cheon Kee;Jae-Kap Choi;Jae-Hyun Sung
    • Journal of Oral Medicine and Pain
    • /
    • v.16 no.1
    • /
    • pp.33-72
    • /
    • 1991
  • The purpose of this study was to investigate the stress distribution and the displacement in the temporomandibular joints following the teeth loss patterns. The three dimensional finite element method was used for a mathematical model. The finite element model was composed of 1,632 elements and 2,411 nodes in the mandible with articular disc and mandibular fossa of the temporal bone. The masseter, the temporal and the internal pterygoid muscle forces were applied at each insertion site, bisecting point of gonion and antegonion, tip of the coronoid process, and gonion at the ration of 2:2:1 respectively. The directions of muscles force were obtained from frontal and lateral cephalometric tracings using bony landmarks of the skull. The results were as follows : 1. In control model, the minimum principal stresses were concentrated on the region of anterosuperior part of the condyle head and articular disc, and maximum principal stresses on the anterior part of the condyle head and posterolateral part of the articular disc. 2. In case of unilateral teeth loss, the greater principal stress appeared at the teeth loss side and the principal stresses increased at the teeth loss side as the number of the posterior teeth loss went up. 3. In case of bilateral teeth loss, the principal stresses were greater than those of the control model and as the number of the posterior teeth loss increased, the grater principal stresses on the temporomandibular joints appeared at the both side. 4. When the posterior teeth existed bilateral, the principal stress patterns were similar to those of the control model. 5. The displacement ws directed mainly upward and backward in the upper part of the temporomandibular joints and upward and forward in the largest part of the condyle head. The displacement increased as the number of the posterior teeth loss went up.

  • PDF

MOUTHGUARD FOR RELIEF OF REPEATED CLENCHING STRESS TO CERVICAL RESTORATIONS DURING EXERCISES (운동시의 습관적인 이 악물기가 치경부 수복물에 가해지는 스트레스를 분산하기 위한 마우스가드의 사용)

  • Yoon, Sung-Young;Song, Chang-Kyu;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.1
    • /
    • pp.20-23
    • /
    • 2010
  • Mouthguards were used to protect boxers from lip lacerations and other soft tissue injuries in the late 19th century. Now they are used various parts of dental treatment, which are sports protective aid, bleaching tray, orthodontic retainer, implant insertion guide tray, splint and so on. Repeated dislodgement of Class V restoration due to habitual clenching stress should be restored with stress control. Mouthguard can be used as stress relief device. This case describes methods that can relieve occlusal force to teeth by using mouthguard. Satisfactory results can be obtained by using mouthguard for retention of repeated dislodgement Class V restorations. If patients suffered from repeated restorations of Class V due to clenching, mouthguard can be used additional device to relieve the occlusal stress in conservative dentistry.

Seymour's Fracture of the Base of the Distal Phalanx in a Child (소아 원위지골 기저부에서 발생한 Seymour씨 골절의 치험례)

  • Kim, Cheol Hann;Tark, Min Sung
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.776-779
    • /
    • 2006
  • Purpose: Prior to closure of the epiphysis of the distal phalanx, fracture usually occurs through the growth plate, Salter-Harris type I or II, or through the juxtaepiphyseal region 1 to 2 mm distal to the growth plate. The terminal tendon of extensor inserts into the epiphysis only, while insertion site of the flexor digitorum profundus spans both the epiphysis and metaphysis. Because of the difference between these tendon insertions, this injury mimics a mallet deformity. But, this type of injury does not involve a tear or avulsion of the extensor, unlike mallet finger of adults. Seymour was the first to describe this type of injury in children and called after his name, Seymour's fracture. This fracture is prone to infection or remain the residual deformity unless adequate treatment. Methods: We report a case of Seymour's fracture. A 9-year-old boy presented a laceration of the nail matrix, with the nail lies degloved from the nail fold on the right middle finger gotten from an impact against a door. An X-ray examination showed the fracture line lying 1 mm distal to the growth plate. The injury was treated with debridement and the fracture was reduced by applying hyperextension force. Under the C-arm, a single 0.7 mm K-wire was used to immobilize the distal interphalangeal joint. Intravenous antibiotics were applied for 5 days after surgery. Results: The K-wire was removed in the 3rd week. No infection or significant deformity was found until follow-up of 12 months. Conclusions: Seymour's fracture may be at first classically mallet deformity by its appearance. But it is anatomically different and more problematic injury. If it isn't corrected at the time of injury, derangement of the extensor mechanism, and growth deformity of the distal phalanx may occur. The fracture site should be debrided, removed of any interposed soft tissue, and the patient should be given appropriate antibiotics. Reduction should be maintained by K-wire fixation. We experienced no infection or premature epiphyseal closure.

A Disparate Low Loss DC to 90 GHz Wideband Series Switch

  • Gogna, Rahul;Jha, Mayuri;Gaba, Gurjot Singh;Singh, Paramdeep
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.2
    • /
    • pp.92-97
    • /
    • 2016
  • This paper presents design and simulation of wide band RF microswitch that uses electrostatic actuation for its operation. RF MEMS devices exhibit superior high frequency performance in comparison to conventional devices. Similar techniques that are used in Very Large Scale Integration (VLSI) can be employed to design and fabricate MEMS devices and traditional batch-processing methods can be used for its manufacturing. The proposed switch presents a novel design approach to handle reliability concerns in MEMS switches like dielectric charging effect, micro welding and stiction. The shape has been optimized at actuation voltage of 14-16 V. The switch has an improved restoring force of 20.8 μN. The design of the proposed switch is very elemental and primarily composed of electrostatic actuator, a bridge membrane and coplanar waveguide which are suspended over the substrate. The simple design of the switch makes it easy for fabrication. Typical insertion and isolation of the switch at 1 GHz is -0.03 dB and -71 dB and at 85 GHz it is -0.24 dB and -29.8 dB respectively. The isolation remains more than - 20 db even after 120 GHz. To our knowledge this is the first demonstration of a metal contact switch that shows such a high and sustained isolation and performance at W-band frequencies with an excellent figure-of merit (fc=1/2.pi.Ron.Cu =1,900 GHz). This figure of merit is significantly greater than electronic switching devices. The switch would find extensive application in wideband operations and areas where reliability is a major concern.

Orthodontic correction of bialveolar protrusion by interproximal reproximation and water-soluble tubes bonded with deflection-based bonding technique: A case report (인접면 삭제와 변위-기반 접착술로 부착한 수용성 튜브를 이용한 절치 돌출의 교정 치료: 증례보고)

  • Roh, Yu-Yeon;Lim, Sung-Hoon;Jeong, Seo-Rin
    • The Journal of the Korean dental association
    • /
    • v.55 no.12
    • /
    • pp.850-860
    • /
    • 2017
  • Orthodontic treatment with premolar extraction is usually performed to correct bialveolar protrusion. These methods require the use of stiff rectangular working archwire which requires lengthy alignment and leveling before insertion. In this case report, interproximal reproximation was performed instead of extraction. To establish clearance between the archwire and resin domes fixing the archwire, an archwire was inserted into a water-soluble tube before fabricating resin domes. This tube is solved away by the saliva. During fabrication of resin domes, the archwire was deflected intentionally reflecting the displacement of teeth from their ideal position. This can be called as deflection-based bonding (DBB) technique. DBB is different from conventional method of positioning the brackets on its ideal position and then inserting an archwire to align the brackets. Because the orthodontic force of the archwire comes from its deflection from passive configuration, deflecting an archwire as needed can move the teeth more predictably than just bonding brackets on its ideal position. Also, areas with good alignment before orthodontic treatment can be maintained simply by not deflecting the archwire during bonding in these areas. After initial alignment, interproximal reproximation was performed to create 4.8 mm space in the maxillary arch and 4.2 mm space in the mandibular arch. These spaces were closed using orthodontic mini-implant anchorage thus retracting the maxillary incisors 4 mm posteriorly accompanied with 0.7 mm and 0.3 mm distal movement of right and left molars. By using interproximal reproximation and water-soluble tube with DBB, mild bialveolar protrusion was successfully treated without extraction.

  • PDF

Seismic retrofitting by base-isolation of r.c. framed buildings exposed to different fire scenarios

  • Mazza, Fabio;Mazza, Mirko
    • Earthquakes and Structures
    • /
    • v.13 no.3
    • /
    • pp.267-277
    • /
    • 2017
  • Base-isolation is now being adopted as a retrofitting strategy to improve seismic behaviour of reinforced concrete (r.c.) framed structures subjected to far-fault earthquakes. However, the increase in deformability of a base-isolated framed building may lead to amplification in the structural response under the long-duration horizontal pulses of high-magnitude near-fault earthquakes, which can become critical once the strength level of a fire-weakened r.c. superstructure is reduced. The aim of the present work is to investigate the nonlinear seismic response of fire-damaged r.c. framed structures retrofitted by base-isolation. For this purpose, a five-storey r.c. framed building primarily designed (as fixed-base) in compliance with a former Italian seismic code for a medium-risk zone, is to be retrofitted by the insertion of elastomeric bearings to meet the requirements of the current Italian code in a high-risk seismic zone. The nonlinear seismic response of the original (fixed-base) and retrofitted (base-isolated) test structures in a no fire situation are compared with those in the event of fire in the superstructure, where parametric temperature-time curves are defined at the first level, the first two and the upper levels. A lumped plasticity model describes the inelastic behaviour of the fire-damaged r.c. frame members, while a nonlinear force-displacement law is adopted for the elastomeric bearings. The average root-mean-square deviation of the observed spectrum from the target design spectrum together with a suitable intensity measure are chosen to select and scale near- and far-fault earthquakes on the basis of the design hypotheses adopted.

The effect of cetirizine, a histamine 1 receptor antagonist, on bone remodeling after calvarial suture expansion

  • Hwang, Soonshin;Chung, Chooryung J.;Choi, Yoon Jeong;Kim, Taeyeon;Kim, Kyung-Ho
    • The korean journal of orthodontics
    • /
    • v.50 no.1
    • /
    • pp.42-51
    • /
    • 2020
  • Objective: The objective of this study was to evaluate the effects of cetirizine, a histamine 1 receptor antagonist, on bone remodeling after calvarial suture expansion. Methods: Sixty male Sprague-Dawley rats were divided into 4 groups; the phosphate-buffered saline (PBS)-injected no expansion group, cetirizine-injected no expansion group, PBS-injected expansion group, and cetirizine-injected expansion group, and were observed at 7, 14, and 28 days. Five rats per group were examined at each observation day. Daily injections of cetirizine or PBS were administered to the relevant groups starting 2 weeks prior to expander insertion. A rapid expander was inserted in the calvarial bone to deliver 100 cN of force to the parietal suture. The specimens were prepared for hematoxylin and eosin and tartrate-resistant acid phosphatase (TRAP) staining. Suture opening and bone regeneration were evaluated using microcomputed tomography and bone histomorphometric analysis. Serum blood levels of osteocalcin and carboxy-terminal collagen crosslinks (CTX) were also evaluated. Results: TRAP-positive cell counts and CTX levels decreased while osteocalcin levels increased in the cetirizine-injected expansion group at observation day 28. In the expansion groups, the mineralized area gradually increased throughout the observation period. At day 28, the cetirizine-injected expansion group showed greater bone volume density, greater mineralized area, and narrower average suture width than did the PBS-injected expansion group. Conclusions: Cetirizine injection facilitated bone formation after suture expansion, mostly by suppressing osteoclastic activity. Histamine 1 receptor antagonists may aid in bone formation after calvarial suture expansion in the rat model.

Shape anisotropy and magnetic properties of Co/Ni anti-dot arrays

  • Deshpande, N.G.;Seo, M.S.;Kim, J.M.;Lee, S.J.;Lee, Y.P.;Rhee, J.Y.;Kim, K.W.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.444-444
    • /
    • 2011
  • Recently, patterned magnetic films and elements attract a wide interest due to their technological potentials in ultrahigh-density magnetic recording and spintronic devices. Among those patterned magnetic structures, magnetic anti-dot patterning induces a strong shape anisotropy in the film, which can control the magnetic properties such as coercivity, permeability, magnetization reversal process, and magneto-resistance. While majority of the previous works have been concentrated on anti-dot arrays with a single magnetic layer, there has been little work on multilayered anti-dot arrays. In this work, we report on study of the magnetic properties of bilayered anti-dot system consisting of upper perforated Co layer of 40 nm and lower continuous Ni layer of 5 nm thick, fabricated by photolithography and wet-etching processes. The magnetic hysteresis (M-H) loops were measured with a superconducting-quantum-interference-device (SQUID) magnetometer (Quantum Design: MPMS). For comparison, investigations on continuous Co thin film and single-layer Co anti-dot arrays were also performed. The magnetic-domain configuration has been measured by using a magnetic force microscope (PSIA: XE-100) equipped with magnetic tips (Nanosensors). An external electromagnet was employed while obtaining the MFM images. The MFM images revealed well-defined periodic domain networks which arise owing to the anisotropies such as magnetic uniaxial anisotropy, configurational anisotropy, etc. The inclusion of holes in a uniform magnetic film and the insertion of a uniform thin Ni layer, drastically affected the coercivity as compared with single Co anti-dot array, without severely affecting the saturation magnetization ($M_s$). The observed changes in the magnetic properties are closely related to the patterning that hinders the domain-wall motion as well as to the magneto-anisotropic bilayer structure.

  • PDF

A STUDY ON THE POLYMERIZATION STRESS OF COMPOSITE RESINS (복합레진의 중합수축력에 관한 연구)

  • Kim, Boo-Rang;Choi, Ho-Young;Min, Byung-Soon;Park, Sang-Jin;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.331-341
    • /
    • 1992
  • The purpose of this study was to measure the polymerization contraction stress of two types of composite resins; chemical cured type(Cliarfil F II, Kuraray, Japan) and photo-cured type(Photo-Clearfil Bright, Kuraray, Japan). The stresses of composite resin by contraction measured with specially designed measuring device(Fig. 1). The stresses caused by shrinkage during hardening of specimens were measured according to the type of composite resins, thickness of specimen(0.65, 1.30 and 1.95mm), and ratio of catalyst to base in case of only chemical cured composite resin(0.5, 1.0 and 1.5). As the composite resin specimen shrank on hardening, the load cell recorded force vs time automatically on pen-recorder(Toa, Japan) with a cross-head speed 60mm/hr at 0~10 voltages up to 2 hours. The experiments were conducted in a room maintained at $23{\pm}2^{\circ}C$ and relative humidity $50{\pm}10%$. The results were as follows. 1. The contraction stress during hardening was higher in photo cured composite resin than in chemical cured composite resin. 2. The contraction stress during hardening was increased with thickness of composite resin specimen. 3. In chemical cured composite resin, the polymerization contraction stress was decreased with ratio of catalyst and base. 4. The contraction stress during polymerization was higher in early time after insertion of photo cured composite resin and chemical cured composite resin.

  • PDF