• Title/Summary/Keyword: Insertion 4p

Search Result 350, Processing Time 0.02 seconds

A Design of Transmission Channel for 40Gb/s backplane Ethernet based on IEEE P802.3ba (IEEE P802.3ba 기반의 40 Gb/s 백플레인 이더넷 전송채널의 설계)

  • Yang, Choong-Reol;Kim, Kwang-Joon;Kim, Whan-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.4B
    • /
    • pp.637-646
    • /
    • 2010
  • For 40 Gb/s data transmission through electrical backplane trace up to 40 inch length on four layer fire-resistant (FR-4), we have designed the 40 Gb/s backplane channel model consisting of four channel 10 Gb/s. Simulation results show an enhancement of backplane channel characteristics excellent more than requirements specified in IEEE P802.3ba at 10 Gb/s. This paper provides a review of the structures and algorithms used in receive and adaptive equalization for 40 Gb/s backplane Ethernet. The use of this backplane channel model could achieves better receive equalizer at great data rate than 10 Gb/s.

The reliability of Anycheck device related to healing abutment diameter

  • Lee, Dong-Hoon;Shin, Yo-Han;Park, Jin-Hong;Shim, Ji-Suk;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.83-88
    • /
    • 2020
  • PURPOSE. The purpose of this in vitro study was to examine the reliability of the Anycheck device and the effect of the healing abutment diameter on the Anycheck values (implant stability test, IST). MATERIALS AND METHODS. Thirty implants were placed into three artificial bone blocks with 10 Ncm, 15 Ncm, and 35 Ncm insertion torque value (ITV), respectively (n = 10). (1) The implant stability was measured with three different kinds of devices (Periotest M, Osstell ISQ Mentor, and Anycheck). (2) Five different diameters (4.0, 4.5, 4.8, 5.5, and 6.0 mm) of healing abutments of the same height were connected to the implants and the implant stability was measured four times in different directions with Anycheck. The measured mean values were statistically analyzed. RESULTS. The correlation coefficient between the mean implant stability quotient (ISQ) and IST value was 0.981 (P<.01) and the correlation coefficient between the meant periotest value (PTV) and IST value was -0.931 (P<.01). There were no statistically significant differences among the IST values with different healing abutment diameters. CONCLUSION. There was a strong correlation between the Periotest M and Anycheck values and between the ISQ and IST. The diameter of the healing abutment had no effect on the Anycheck values.

Another Glenoid Measurements for Shoulder Surgery

  • Jeong, Yeon-Seok;Yum, Jae-Kwang;Lee, Jun-Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.4
    • /
    • pp.179-185
    • /
    • 2018
  • Background: We analyzed the angle between the glenoid anterior surface and glenoid axis, the range of the glenoid apex and the location of the glenoid apex for assistance during shoulder surgery. Methods: Sixty-two patients underwent a computed tomography of the shoulder with a proximal humerus fracture. In the range of the glenoid apex, the ratios of the distribution of triangles with a Constant anterior and posterior area of the glenoid were measured. The location of glenoid apex was confirmed as the percentage of the position with respect to the upper part of the glenoid with the center of the part, analyzed the angle between the glenoid anterior surface and glenoid axis was measured. Results: The angle between the glenoid anterior surface and glenoid axis was $19.80^{\circ}{\pm}3.88^{\circ}$. The location of the glenoid apex is $60.36%{\pm}9.31%$, with the upper end of the glenoid as the reference. The range of the glenoid apex was $21.16%{\pm}4.98%$. When the height of the glenoid becomes smaller, the range of the glenoid apex tends to become larger (p=0.001) and the range of the glenoid apex becomes wider (p=0.001) as the glenoid width narrows. Conclusions: We believe the anatomical measurements of the glenoid will be helpful for a more accurate insertion in glenoid component. It is thought that more accurate insertion is possible if we can set other anatomical measurements using computed tomography imaging of the glenoid which can develop into the study of other anatomical measurements.

Evaluation of the stability of sandblasted, large-grit, acid-etched implants with tapered straight body design (테이퍼드 직선형 SLA 임플란트의 안정성 평가)

  • Kim, Yong-Gun;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.80-88
    • /
    • 2018
  • Purpose: Implant surface modification and implant design are the principle targets for achieving successful primary stability. The aim of this study was to measure implant stability quotient (ISQ) values of sandblasted, large-grit, acid-etched (SLA) implants with tapered straight body design during the healing period, and to determine the various factors affecting implant stability. Materials and Methods: To measure implant stability, resonance frequency analysis (RFA) was performed in 26 patients (13 women and 13 men) with 44 SLA implants with tapered straight body design. Implant stability (ISQ values) was evaluated at baseline and healing abutment connection (12 weeks), and the correlations between RFA and insertion torque (IT), bone quality, and jawbone were determined. Results: The mean ISQ value of the implants was $69.4{\pm}10.2$ at the time of implant placement (baseline) and $81.4{\pm}6.9$ at the time of healing abutment connection (P < 0.05). Significant differences were found between RFA and bone quality and between RFA and jawbone (P < 0.05). No significant differences were found between RFA and IT, insertion area, fixture diameter, and implant length (P > 0.05). Conclusion: ISQ values of SLA implants with tapered straight body design were high at baseline and healing abutment connection. It was concluded that SLA implants with tapered straight body design show improved primary and secondary stability, and that immediate or early loading may be applicable.

Comparison of the retentive characteristics of two additional attachment used with an implant bar attachment (임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장 치의 유지력 특성 비교)

  • Choi, Jae-Won;Chae, Sung-Ki;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.173-180
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the retentive characteristics of the additional attachments used with implant bar attachment under repeated insertion/removal cycles. Materials and methods: The newly developed attachment and the commercially available attachment were investigated: ADD-Lock (AL), Locator blue (LB). Two fixtures were placed parallel to each other on the custom lower mounting, and patrix of each attachment was fixed to the fixture. Also, the matrix of each attachment was placed on the opposing upper mounting. A universal testing machine was used to measure the retentive force during initial, 100, 250, 500, 1000, 2000, and 2500 repeated insertion/removal cycles. Wear and deformation of the attachment s were observed by scanning electron microscopy (SEM). Mann-Whitney U test (α=.05) and wilcoxon signed-rank test (α=.05) were performed to compare retentive force between each group and before and after 2500 repeated insertion/removal cycles. Results: In terms of initial retentive force and retentive force after 2500 repeated insertion/removal cycles, the AL group (15.24 ± 1.46 N and 9.74 ± 1.16 N) showed significantly smaller values than the LB group (43.53 ± 12.39 N and 22.99 ± 4.77 N) (P<.05). Also, in the loss of retentive force, the AL group (5.50 ± 1.08 N, 36.08%) showed a smaller value than the LB group (20.54 ± 11.89 N, 47.19%) (P<.05). Based on SEM analysis, The AL group showed noticeable wear and deformation in the patrix and the LB group in the matrix. Conclusion: Locator showed a higher initial retentive force than newly developed attachment, while the loss of retentive force was also higher. Both additional attachments are considered to have sufficient retentive force after repeated insertion/removal cycles.

Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar

  • Chae, Sung-Ki;Cho, Won-Tak;Choi, Jae-Won;Bae, Eun-Bin;Bae, Ji-Hyeon;Bae, Gang-Ho;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.12-21
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models. MATERIALS AND METHODS. Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADD-TOC; PNUAdd Co., Ltd., Busan, Republic of Korea) as the experimental group. A CAD-CAM milled bar was mounted on a master model and 3 threaded holes for connecting a bar attachment was formed using a tap. Locator and ADD-TOC attachments were then attached to the milled bar. Simulated mastication and repeated insertion/removal were performed over 400,000 cyclic loadings and 1,080 insertions/removals, respectively. Wear patterns on deformed attachment were investigated by field emission scanning electron microscopy. RESULTS. For the ADD-TOC attachments, chewing simulation and repeated insertion/removal resulted in a mean initial retentive force of 24.43 ± 4.89 N, which were significantly lower than that of the Locator attachment, 34.33 ± 8.25 N (P < .05). Amounts of retention loss relative to baseline for the Locator and ADD-TOC attachments were 21.74 ± 7.07 and 8.98 ± 5.76 N (P < .05). CONCLUSION. CAD-CAM milled bar with the ADD-TOC attachment had a lower initial retentive force than the Locator attachment. However, the ADD-TOC attachment might be suitable for long-term use as it showed less deformation and had a higher retentive force after simulated mastication and insertion/removal repetitions.

Implementation of Quad-Band p-HEMT SP6T Switch for Handset Applications (개인 휴대통신용 4중대역 p-HEMT SR6T 스위치 구현)

  • Shin, One-Chul;Jeong, In-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.1
    • /
    • pp.97-101
    • /
    • 2011
  • Quad band p-HEMT SP6T switch for handset applications was developed. To achieve the low insertion loss and high isolation, trade-off between "On" state and "Off" state was considered by optimization of unit cell. Especially, in case isolation between transmit port and receive port, it was achieved by large capacitors and miniaturization of chip size was achieved by common voltage control and ground using back via process. Designed SP6T switch has size of $950um{\times}100um$ and take into consideration the gate recess error, excellent loss and isolation was confirmed in operating frequency.

Characterization of the Genes of Salmonella typhimurium conferring the penetration of cultured HEp-2 and Chinese hamster cells

  • Park, Jeong-Uk;Jeong, Mi-Yeon;Kim, Mi-Rim;Jeong, Yeong-Gi;Ju, U-Hong
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.584-587
    • /
    • 2000
  • The invasion genes from Salmonella typhimurium were identified by the construction of a cosmid library and subcloning genes into a plasmid vector, pGEM-7Z. The 4.65 kb fragment of the invasion-conferring genomic region of the subclone, pSV6235 was sequenced in both direction. The three open reading frames, which were located at downstream of a promoter region, were designated as sir (Salmonella invasion region)A coding for the 36 amino acids, sirB coding for the 132 amino acids and sirC for the 82 amino acids, respectively. Interesingly, the genomic region of pSV6235 was highly homologous to Yersinia enterocolitica genomic DNA for a high pathogenicity island and Salmonella enteritidis insertion element IS1351 and IS200 DNA. These results show that there could be a significant relationship between S. typhimurium, Y. enterocolitica and S. enteritidis with respect to horizontal evolution process and acquisition of virulence determinants by means of transposon, plasmid or bacteriophage.

  • PDF

Evidence for two $Na^+$/$H^+$ Antiport Systems in Escherichia coli

  • Seo, Sung-Yum
    • Korean Journal of Microbiology
    • /
    • v.30 no.4
    • /
    • pp.269-277
    • /
    • 1992
  • Several insertion mutants of Escherichia coli in the ant gene, coding for $Na^{+}$ $H^{+}$ antiport activity, showed littel, if any, reduction in the antiport activity. $Na^{+}$ dependent transport activity also remained at wild type level. These facts led to the idea that E. coli has evolved at least two distinct systems for extrusion of $Na^{+}$ The antiport activities were studied under various conditions to reveal different properties of these systems. For convenience these activities are referred to as major and minor activities. The distinguishing properties of the two systems include : kinetics (Km, Vm) at pH 7.8, competition pattern between $Na^{+}$ and Li$^{+}$ , pH profiles, pattern of the change in kinetic parameters as a function of pH, and sensitivity to protease, chemicals and heat.

  • PDF

( A Study on the Characteristics of the P ( VDF-TrFE ) Acoustic Microscope Transducer (P (VDF-TrFE ) 초음파현미경용 트랜스듀서의 특성에 관한 연구)

  • 하강열
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.30 no.3
    • /
    • pp.227-236
    • /
    • 1994
  • The characteristics of the P(VDF-TrFE) acoustic microscope transducer were evaluated theoretically and experimentally by comparison with those of the PVDF and the ZnO acoustic microscope transducers. It was found that its insertion loss was about 5dB lower than that of the PVDF and about 13$\textbf{dB}$ higher than that of the ZnO. And its relative bandwidth was 20% which could produce the effective acoustic pulse waves having about 4 periods duration into water. Another finding was that the effective horizontal focusing resolution and the focal depth were $120\mu m and $1.5mm$, respectively.

  • PDF