• 제목/요약/키워드: Input-output method

검색결과 2,857건 처리시간 0.026초

소속함수 수정 알고리즘과 ANFIS를 이용한 퍼지논리 제어기의 설계 (Design of FLC using the Membership function modification algorithm and ANFIS)

  • 최완규;이성주
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2001년도 춘계학술대회 학술발표 논문집
    • /
    • pp.43-46
    • /
    • 2001
  • We, in this paper, design the Sugeno-models fuzzy controller by using the membership function modification algorithm and ANFIS, which are clustering and learning the input-output data. The membership function modification algorithm constructs the more concrete fuzzy controller by clustering the input-output data from the fuzzy inference system. ANFIS construct the Sugeno-models fuzzy controller by learning the input-output data from the above controller. We showed that the fuzzy controller designed by our method could have the stable learning and the enhanced performance.

  • PDF

Medical Tourism Industry in Kangwon Province and Its Economic Impacts on the Region

  • Zhu, Yan Hua;Kang, Joo Hoon;Jung, Yong-Sik
    • 한국산업정보학회논문지
    • /
    • 제19권3호
    • /
    • pp.115-125
    • /
    • 2014
  • This paper has two purposes. The first is to suggest the new and simple method to derive a regional input-output model from the national input-output table published by the Bank of Korea. The interregional input-output table has not been devised in spite of its potential use while the national table has been made every five years with the revised version during each five years. Second, this paper aims to derive Kangwon interregional input-output model from the national model using the regional supply proportion of industry and to analyze the effect of medical tourism industry on the regional economy of Kangwon Province. The paper measures, in particular, the effect of medical tourism industry on the financial self-sufficiency of Kangwon Province using the estimated output elasticity of tax revenue with the autoregressive distributed lag scheme ADL(1,1) in which the dependent variable and the single explanatory variable are each lagged once.

Separate Fuzzy Regression with Crisp Input and Fuzzy Output

  • Yoon, Jin-Hee;Choi, Seung-Hoe
    • Journal of the Korean Data and Information Science Society
    • /
    • 제18권2호
    • /
    • pp.301-314
    • /
    • 2007
  • The aim of this paper is to deal with a method to construct a separate fuzzy regression model with crisp input and fuzzy output data using a best response function for the center and the width of the predicted output. Also we introduce the crisp mean and variance of the predicted fuzzy value and also give some examples to compare a performance of the proposed fuzzy model with various other fuzzy regression model.

  • PDF

고정밀 자석전원을 위한 전류형 PWM 컨버터의 입출력 필터설계 (Input and output filter design of current source PWM converter for high-precision magnet power supply)

  • 김효성;최재호
    • 대한전기학회논문지
    • /
    • 제45권1호
    • /
    • pp.30-41
    • /
    • 1996
  • Current Source(CS) PWM converter is appropriate for the magnet power supply system which requests high power and high precision current control. Input and output filters should be installed to eliminate the current or voltage harmonics caused by the PWM switching for the CS PWM converter. But the input/output filters limit the output DC current range and may destroy the system with filter resonance, and make the system equation more complicated. In this paper, systematic and simple filter design method which considers not only the harmonic attenuation but also the total system good transfer function characteristics in the dc filter. The simulated and experimental results verify the proposed theory. (author). refs., figs., tabs.

  • PDF

Survey of National Corrosion Cost

  • Kim, Jong Jip
    • Corrosion Science and Technology
    • /
    • 제5권5호
    • /
    • pp.173-176
    • /
    • 2006
  • Previous national studies on costs of corrosion are reviewed and brief explanations are given of the Uhlig method, Hoar method and Input-output method that are employed for corrosion cost estimation. Total costs of corrosion of 11 countries are summarized and the results by Uhlig methods are compared especially for the recent studies from the U.S, Japan and China.

입출력 큐를 갖는 ATM 스위치에서의 우선순위에 관한 성능 분석 (Performance study of the priority scheme in an ATM switch with input and output queues)

  • 이장원;최진식
    • 전자공학회논문지S
    • /
    • 제35S권2호
    • /
    • pp.1-9
    • /
    • 1998
  • ATM was adopted as the switching and multiplexing technique for BISDN which aims at transmitting traffics with various characteristics in a unified network. To construct these ATM networks, the most important aspect is the design of the switching system with high performance and different service capabilities. In this paepr, we analyze the performance of an input and output queueing switch with preemptive priority which is considered to be most suitable for ATM networks. For the analysis of an input queue, we model each input queue as two separate virtual input queues for each priority class and we approximage them asindependent Geom/Geom/1 queues. And we model a virtual HOL queue which consists of HOL cells of all virtual input queues which have the same output address to obtain the mean service time at each virtual input queue. For the analysis of an output quque, we obtain approximately the arrival process into the output queue from the state of the virtual HOL queue. We use a Markov chain method to analyze these two models and obtain the maximum throughput of the switch and the mean queueing delay of cells. and analysis results are compared with simulation to verify that out model yields accurate results.

  • PDF

다차원 스펙트럼 해석법을 이용한 차실내 운전자석 진동전달경로 규명에 관한 연구 (A Study on Vibration Transfer Path Identification of Vehicle Driver's Position by Multi-dimensional Spectral Analysis)

  • 이유엽;박상길;오재응
    • 한국소음진동공학회논문집
    • /
    • 제17권8호
    • /
    • pp.741-746
    • /
    • 2007
  • In this study, transfer path identification and output estimation are simulated by multi-dimension spectral analysis method (MDSA). Multi -input/single-output system give expression the vehicle suspension which each inputs are correlated reciprocally. In case of correlating with inputs, the system needs separating the each input signal by MDSA. Main simulations are about finding effective input by coherent output spectrum and selecting optimal input's number by multiple coherence function. Also, by shielding transfer path of each input, transfer path characteristic is identified in terms of overall integrated contribution level.

단상 다기능 UPS 입.출력 필터 설계 (Design of Input.Output Filter of Single Multifunctional UPS)

  • 김제홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.307-310
    • /
    • 2002
  • A design for the input filter and the output filter of a single-phase UPS system is proposed. And also, this paper describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

퍼지모델의 새로운 설정 방법 (A New Identification Method for a Fuzzy Model)

  • 박민기;지승환;박민용
    • 한국지능시스템학회논문지
    • /
    • 제5권2호
    • /
    • pp.70-78
    • /
    • 1995
  • 입출력 데이터를 이용한 퍼지모델의 설정은 구조 설정과 변수 설정으로 나누어진다. 본 논문에서는 기존 방법의 문제점을 해결하고 퍼지모델의 이러한 구조와 변수를 설정하는 새로운 방법을 제안한다. 입출력 데이터가 주어지면, 후건부 변수는 선형성과연속성을 고려하여 휴(Hough) 변환과클러스터링 방법에 의해 각각 설정된다. 또한 경사 하강법(Gradient descent method)을 사용하여 퍼지모델 변수의 미세조정을 행한다. 마지막으로 단일 입출력 시스템에 대하여 시뮬레이션을 통해 제안된 방법의 유효성을 보인다.

  • PDF

전압 이득과 변조지수 제어에 의한 3상 Z-소스 인버터의 출력 교류 전압 제어 (Output AC Voltage Control of a Three-Phase Z-Source Inverter by the Voltage Gain and Modulation Index Control)

  • 김세진;정영국;임영철;양승학
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1996-2005
    • /
    • 2010
  • This paper proposes a new method for constant control of the output AC voltage of a voltage-fed three phase Z-source inverter (ZSI), in case of Z-network DC voltage variation or heavy change of load. The modulation index for the reference output AC voltage of ZSI can be calculated by the basic definition of ZSI, the input DC voltage and capacitor voltage of Z-network. And, the output AC voltage of ZSI is controlled by the modified space vector modulation (SVM) with the calculated modulation index. By the proposed method, the modulation index of output AC voltage is closely following in the reference modulation index. The validity of the proposed method is verified using PSIM simulation. In case which the input DC voltage of ZSI is heavily changed from 100[V] to 70[V] (or to 150[V]) and in case which load is changed from $30[\Omega]$ to $10[\Omega]$, we confirmed that the output AC voltage of ZSI is constantly controlled by the proposed method because the modulation index of ZSI is also simultaneously changed. Finally, FFT and %THD of the output voltage and current of ZSI by the proposed method are analyzed.