• Title/Summary/Keyword: Input output analysis

Search Result 2,374, Processing Time 0.031 seconds

Analysis, Design and Implementation of a Soft Switching DC/DC Converter

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.20-30
    • /
    • 2013
  • This paper presents a soft switching DC/DC converter for high voltage application. The interleaved pulse-width modulation (PWM) scheme is used to reduce the ripple current at the output capacitor and the size of output inductors. Two converter cells are connected in series at the high voltage side to reduce the voltage stresses of the active switches. Thus, the voltage stress of each switch is clamped at one half of the input voltage. On the other hand, the output sides of two converter cells are connected in parallel to achieve the load current sharing and reduce the current stress of output inductors. In each converter cell, a half-bridge converter with the asymmetrical PWM scheme is adopted to control power switches and to regulate the output voltage at a desired voltage level. Based on the resonant behavior by the output capacitance of power switches and the transformer leakage inductance, active switches can be turned on at zero voltage switching (ZVS) during the transition interval. Thus, the switching losses of power MOSFETs are reduced. The current doubler rectifier is used at the secondary side to partially cancel ripple current. Therefore, the root-mean-square (rms) current at output capacitor is reduced. The proposed converter can be applied for high input voltage applications such as a three-phase 380V utility system. Finally, experiments based on a laboratory prototype with 960W (24V/40A) rated power are provided to demonstrate the performance of proposed converter.

A Prototype Development of Personal Low-frequency Stimulator with Characteristic Analysis (개인용 저주파 자극기의 특성분석 및 Prototype개발)

  • Lee, Gi-Song;Lee, Dong-Ha;Yu, Jae-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.349-352
    • /
    • 2003
  • A personal low-frequency stimulator is a portable device to relax muscle pains of a person. The stimulator generates combined low-frequency pulses to be applied to pads attached to painful muscles. This paper reports a development of such device with its characteristic analyses. The major components of our stimulator are MCU, high-voltage generating circuit part, high-voltage switching circuit part, input switch part and display unit. High-voltage generating circuit is designed by using a boost converter circuit and allows user control of the output voltage. High-voltage switching circuit, controlled by MCU, generates output voltage to be applied to pads. Input switch part is composed of power supply, intensity selection, mode selection and memory. Display unit adopts a text LCD module to display modes, Intensity, output frequency and user set-up time. Our designed safety circuit, to protect human body from possible electric shock, slowly increases the output voltage to the selected output intensity. It continuously checks the output pulse shape and disable the output when dangerous pulses are detected. This paper also shows some experimental results.

  • PDF

Design and FEM Analysis of Multilayer Piezoelectric Transformer for AC-adapter (AC-adapter를 위한 적층형 압전트랜스포머의 설계 및 유한요소해석)

  • 정현호
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.529-533
    • /
    • 2000
  • This paper present a new sort of multilayer piezoelectric ceramic transformer for AC-adapt. This piezoelectric transformer operates n the second thickness extensional vibration mode. The output voltage of the multilayer piezoelectric transformer was simulated using ANSYS. As results, the maximum stress appeared at the two points where one is the middle of input and the other is middle of output side in Second thickness extensional vibration mode. And output voltage was inversely decreased by increasing number of output layers.

  • PDF

Design and Response Analysis of Wideband Monopulse Radar System Robust to Noise Jamming Signal (잡음 재밍 신호에 강인한 광대역 모노펄스 레이더 시스템 설계 및 응답 특성 분석)

  • Shin, Bohun;Yang, Haejoon;Kim, Changyeol;Park, Soryoung;Noh, Sanguk;Nam, Ilku
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.94-102
    • /
    • 2018
  • In this paper, the wideband mono-pulse radar using AGC and limiter is designed. The output response characteristics of the mono-pulse radar using AGC and limiter are analyzed, respectively. In addition, the output response for jamming input signals is analyzed. The range tracking loop in the mono-pulse radar has robust output response to the noise jamming input signal. Although the output settling response of the AGC-based mono-pulse radar is larger than that of the limiter-based mono-pulse radar, the AGC-based mono-pulse radar has robustness to the noise jamming input signal due to feedback loop.

An Economic Evaluation about Research and Development for Renewable energy in Korea (대체에러지 기술개발에 대한 수익성 평가분석)

  • 전영서;김진오
    • Journal of Korea Technology Innovation Society
    • /
    • v.7 no.2
    • /
    • pp.325-349
    • /
    • 2004
  • This paper tried to evaluate an economic analysis about research and development far areas of renewable resource in Korea. To evaluate this validity, we tried to calculate the spillover effect of R&D investment through input-output table. In the first stage of spillover effect, we simply calculate the rate of return on R&D investment for renewable energy resources in Korea through the input-output model, which can calculate the value added as well as output based upon the price of 2000 year. According to the first stage calculation, the rate of return on R&B investment in solar heat is higher than any other renewable energy. In the second stage we tried to calculate the second round of spill over effect, which derives from the additional amount of supply of renewable resources due to the R&D investment. The overall evaluation of R&D invesment including the first stage as well as second stage spillover effect shows that bio-energy and waste energy generate 14 times as well as 2.5 times in the rate of return respectively.

  • PDF

Medium Voltage Resonant Converter with Balanced Input Capacitor Voltages and Output Diode Currents

  • Lin, Bor-Ren;Du, Yan-Kang
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.389-398
    • /
    • 2015
  • This paper presents a 1.92 kW resonant converter for medium voltage applications that uses low voltage stress MOSFETs (500V) to achieve zero voltage switching (ZVS) turn-on. In the proposed converter, four MOSFETs are connected in series to limit the voltage stress of the power switches at half of the input voltage. In addition, three resonant circuits are adopted to share the load current and to reduce the current stress of the passive components. Furthermore, the transformer primary and secondary windings are connected in series to balance the output diode currents for medium power applications. Split capacitors are adopted in each resonant circuit to reduce the current stress of the resonant capacitors. Two balance capacitors are also used to automatically balance the input capacitor voltage in every switching cycle. Based on the circuit characteristics of the resonant converter, the MOSFETs are turned on under ZVS. If the switching frequency is less than the series resonant frequency, the rectifier diodes can be turned off under zero current switching (ZCS). Experimental results from a prototype with a 750-800 V input and a 48V/40A output are provided to verify the theoretical analysis and the effectiveness of the proposed converter.

SAMPLING BASED UNCERTAINTY ANALYSIS OF 10 % HOT LEG BREAK LOCA IN LARGE SCALE TEST FACILITY

  • Sengupta, Samiran;Dubey, S.K.;Rao, R.S.;Gupta, S.K.;Raina, V.K
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.690-703
    • /
    • 2010
  • Sampling based uncertainty analysis was carried out to quantify uncertainty in predictions of best estimate code RELAP5/MOD3.2 for a thermal hydraulic test (10% hot leg break LOCA) performed in the Large Scale Test Facility (LSTF) as a part of an IAEA coordinated research project. The nodalisation of the test facility was qualified for both steady state and transient level by systematically applying the procedures led by uncertainty methodology based on accuracy extrapolation (UMAE); uncertainty analysis was carried out using the Latin hypercube sampling (LHS) method to evaluate uncertainty for ten input parameters. Sixteen output parameters were selected for uncertainty evaluation and uncertainty band between $5^{th}$ and $95^{th}$ percentile of the output parameters were evaluated. It was observed that the uncertainty band for the primary pressure during two phase blowdown is larger than that of the remaining period. Similarly, a larger uncertainty band is observed relating to accumulator injection flow during reflood phase. Importance analysis was also carried out and standard rank regression coefficients were computed to quantify the effect of each individual input parameter on output parameters. It was observed that the break discharge coefficient is the most important uncertain parameter relating to the prediction of all the primary side parameters and that the steam generator (SG) relief pressure setting is the most important parameter in predicting the SG secondary pressure.

Extended Fuzzy DEA

  • Guo, Peijun;Tanaka, Hideo
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.06a
    • /
    • pp.517-521
    • /
    • 1998
  • DEA(data envelopment analysis) is a non-parametric technique for measuring and evaluating the relative efficiencies of a set of entities with common crisp inputs and outputs. In fact, in a real evaluation problem input and output data of entities often flucturate. These fluctuating data can be represented as linguistic variables characterized by fuzzy numbers. Based on a fundamental CCR model, a fuzzy DEA model is proposed to deal with fuzzy input and output data, Furthermore, a model that extends a fuzzy DEA to a more general case is also proposed with considering the relation between DEA and RA (regression analysis) . the crisp efficiency in CCR modelis extended to an L-R fuzzy number in fuzzy DEA problems to reflect some uncertainty in real evaluation problems.

  • PDF

Sweden at the Innovation Frontier - Assessing Performance and Challenges in a Disruptive World

  • Deiaco, Enrico;Bager-Sjogren, Lars
    • STI Policy Review
    • /
    • v.3 no.2
    • /
    • pp.1-46
    • /
    • 2012
  • The paper assesses the innovative performance and challenges that a small innovative country like Sweden faces in an era of intense global competition. We contrast innovative performance with similar countries in Europe as well as discus the reliability and validity of indicators used to shape policy development. The conclusion from the analysis shows that available input-output indicators must be used with some caution. Even if the supply and quality of indicators has increased for policy analysis, they still lack precision and validity to make broad claims about the innovative performance of companies and nations. It is argued that understanding knowledge flows (rather than simple input-output metrics) are a key to understand innovation processes for small countries at the innovation frontier; subsequently, small countries will have to abandon failed policy orthodoxies in order to cope with future policy challenges.