• Title/Summary/Keyword: Input Current Improvement

Search Result 182, Processing Time 0.032 seconds

An Input Current Waveshaping AC-DC Converter for Rectifier Loads

  • Singh, Bhim;Garg, Vipin;Bhuvaneswari, G.
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • This paper presents the design and analysis of a new input AC current wave shaping AC-DC converter for cost effective harmonic mitigation under varying loads. The proposed converter consists of a delta-polygon connected autotransformer based twelve-pulse AC-DC converter and a small rating passive shunt filter tuned at $11^{th}$ harmonic frequency. The proposed AC-DC converter eliminates the most dominant $5^{th},\;7^{th}$ and $11^{th}$ harmonics and reduces higher order harmonics; thereby, resulting in an improved power quality at AC mains. Moreover, the design of the autotransformer is modified to make it suitable for retrofit applications, where presently a 6-pulse diode bridge rectifier is used. To validate the proposed approach, various power quality indices are presented under varying loads. Experimental results obtained on the developed converter are given to validate the model and design of the proposed converter.

Topology of input current waveform improvement type single-phase rectifier (입력전류 파형 개선형 단상 정류기의 토폴로지)

  • 이상현;박진민;문상필;서기영
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.403-406
    • /
    • 2003
  • For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. However, most of these employ switching devices, such as FET and the like. The absence of switching devices mattes systems more tolerant to over-load and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced The result are confirmed by the theoretical and experimental implementations.

  • PDF

Characteristics of Non-Isolated OSAKA Converter -Characteristics of Three-Phase Soft-Switching Power Factor Corrected Converter for Large Scale Power Without Three-Phase Transformer-

  • Taniguchi, Katsunori;Shimomori, Wataru;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1383-1386
    • /
    • 2005
  • Non-isolated OSAKA Converter, which removes a three-phase transformer, is described in this paper. The converter switches once in every half cycle of an AC commercial power source. Therefore, it can solve many problems caused by the high frequency operation. The proposed converter achieves the soft-switching operation and the EMI noise can be reduced. In this circuit, the resonant capacitor, which is used for the soft-switching operation, is utilized for the improvement of an input current waveform. To achieve low cost and compact structure, non-isolated OSAKA converter removes a three-phase transformer of the OSAKA converter. By removing the three-phase transformer, three phase currents occur the interferences each other. To avoid the interference, a new switching method for non-isolated OSAKA converter is preposed. The converter can be constructed by the low-speed large power devices. The converter generates the low distorted input current waveforms with high power factor.

  • PDF

Contract Awarding Process and its Reasonable Improvement for Defense Acquisition (공공사업 경쟁입찰에서 낙찰자 결정방법분석 및 국방획득사업의 합리적인 사업자결정 방안)

  • Eo, Hajoon;Kim, Sung-Chul
    • Journal of Information Technology Services
    • /
    • v.14 no.2
    • /
    • pp.69-86
    • /
    • 2015
  • The current contract awarding process regulated by laws and ordinances is analyzed and more reasonable processes are suggested. To this end, the principle of economic analysis is described with emphasis on the cost-effectiveness analysis, and the laws and ordinances regulating the process are thoroughly examined. The current contract awarding rule is based on the weighted sum of effectiveness score and cost score. This may not conform to the framework of economic analysis where effectiveness is supposed to be measured as an output and cost measured as an input. An improvement is attempted to the defense acquisition system and it is recognized that the economic analysis and policy consideration should be performed separately. Concept of statistical testing is introduced to see if the results of the cost effectiveness analyses show the significant difference between the alternatives. It is suggested that the contract awarding process can be improved by performing significance test followed by the aggregation of the two analyses. A minor improvement is also suggested on the application of current rules.

A Control Scheme for Quality Improvement of Input-Output Current of Small DC-Link Capacitor Based Three-Level NPC Inverters (소용량 직류단 커패시터를 가지는 3-레벨 NPC 인버터의 입-출력 전류 품질 향상을 위한 제어 기법)

  • In, Hyo-Chul;Kim, Seok-Min;Park, Seong-Soo;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.369-372
    • /
    • 2017
  • This paper presents a control scheme for three-level NPC inverters using small DC-link capacitors. To reduce the inverter system volume, the film capacitor with small capacitance is a promising candidate for the DC-link. When small capacitors are applied in a three level inverter, however, the AC ripple component increases in the DC-link NPV (neutral point voltage). In addition, the three-phase input grid currents are distorted when the DC-link capacitors are fed by diode rectifier. In this paper, the additional circuit is applied to compensate for small capacitor systems defect, and the offset voltage injection method is presented for the stabilization in NPV. These two proposed processes evidently ensure the quality improvement of the input grid currents and output load currents. The feasibility of the proposed method is verified by experimental results.

A Study on the Single Phase Voltage-Controlled Active Power Filter for Power Quality Improvement (전력품질 개선을 위한 단상 전압제어형 능동전력필터 시스템에 관한 연구)

  • 손진근
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.238-245
    • /
    • 2003
  • In this paper, a single Phase voltage source voltage-controlled active power filter(APF) for power quality improvement was proposed. The proposed APF has the performance of harmonic suppression and unity power factor correction. The performance of harmonic suppression can be obtained by controlling the waveshape of the APF output voltage to be sine wave. And, unity power factor is controlled by the reactive power control loop of the APF output. Simulation and experimental results using diode rectifier showed that the voltage-controlled APF, unlike the current-controlled APF, can reduce the voltage harmonics as well as current harmonics. Also the results showed that the input dover factor and power quality were greatly improved.

A Study on the Power Factor Improvement of Ballast (전구식 형광등 안정기의 역률개선에 관한 인구)

  • Choi, J.D.;Oh, S.U.;Seong, S.J.;Baek, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.522-524
    • /
    • 1994
  • This paper presents power factor and distortion improvement methods via active boost converter and mode select. This method not only reduces the current and voltage distortion but also the physical size and expected low cost. Optimum parameter values arc derived to minimize the harmonise in the input current. A theoretical analysis, simulation and experimental results arc presented.

  • PDF

The Improvement of Matching of Amplifier Input Transistor for Display Driver IC (Display Driver IC용 Amplifier Input Transistor의 Matching 개선)

  • Kim, Hyeon-Cheol;Roh, Yong-Han
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.3
    • /
    • pp.213-216
    • /
    • 2008
  • The voltages for pixel electrodes on LCD panels are supplied with analog voltages from LCD Driver ICs (LDIs). The latest LDI developed for large LCD TV's has suffered from the degradation of analog output characteristics (target voltage: AVO and output voltage deviation: dVO). By the failure analysis, humps in $I_D-V_G$ curves have been observed in high voltage (HV) NMOS devices for input transistors in amplifiers. The hump is investigated to be the main cause of the deviation for the driving current in HV NMOS transistors. It also makes the matching between two input transistors worse and consequently aggravates the analog output characteristics. By simply modifying the active layout of HV NMOS transistors, this hump was removed and the analog characteristics (AVO &dVO) were improved significantly. In the help of the improved analog characteristics, it also became possible to reduce the size of the input transistors less than a half of conventional transistors and significantly improve the integration density of LDIs.

Performance of Compressor with Variable Capacity (용량가변 방식을 적용한 압축기의 성능연구)

  • 권영철;진의선;허삼행;김대훈;홍주태;문제명
    • Journal of Energy Engineering
    • /
    • v.13 no.3
    • /
    • pp.214-218
    • /
    • 2004
  • In the present study, the variation of input power and efficiency improvement of a scroll compressor applying PWM method are experimentally investigated. The cooling capacity, input power and COP are measured under the cooling operation. The input power due to the change of the condenser and the coil addition in a main current part is measured to enhance the compressor efficiency. Measured results show that the input power and COP increase with increasing the tooling capacity. And the minimum input power of the compressor is observed. By the adoption of the double system, the consumption of compressor input power is reduced, compared with the existing system.

An Empirical Study of Comprehensive Health Screening Medical Service Quality with Kano Model and PCSI Index (Kano 모델 및 PCSI 지수를 활용한 종합건강검진 의료서비스 품질에 대한 실증적 연구)

  • PARK, Ae-Jun
    • The Journal of Industrial Distribution & Business
    • /
    • v.10 no.7
    • /
    • pp.71-82
    • /
    • 2019
  • Purpose - This study aims to identify the priorities of medical service quality improvement by customer satisfaction characteristics and potential customer satisfaction improvement (PCSI) index based on the dualistic quality classification of Kano Model (1984) for Comprehensive Health Screeening Center in General Hospitals and Centers only for Comprehensive Health Screening and suggest a direction for future improvement. Research design, data, and methodology - Through advanced research on health screening medical service quality, this study set four service quality factors, including tangible, human, process and supportive factors, and 39 measurement items. Based on these items, the study used 117 questions, which consist of dualistic quality factors, customer satisfaction coefficients, positive and negative questions for PCSI index and questions for current satisfaction. 300 effective samples were collected for adults in their 20s who experienced health screening service in Seoul, Gyeonggi-do and Incheon within the past two years. Collected data were input in the quality evaluation duality table to categorize quality factors and calculate customer satisfaction coefficients by Timko(1993). The study also analyzed PCSI index in comparison with current satisfaction and identified priorities in quality improvement. Results - It was found that the most urgent factors to improve the quality in both groups were adequate waiting hours and emergency response for complications, which are process factors classified as unitary quality. It is urgently needed to improve the quality as the PCSI index was high in supportive factors (complaint response team) as attractive quality in Comprehensive Health Screening Center in General Hospitals and in process factors (prevention of infection) as unitary quality in Centers only for Comprehensive Health Screening. As the PCSI index was low in space use as a tangible factor, it was found that the current level can be maintained instead of improvement. Conclusions - To improve the health screening medical service quality, it is required to focus on process factors (adequate waiting hours, emergency response for complications, prevention of infection) and supportive factors (complaint response team) among service qualities perceived by users. It is proposed to ensure continuous efforts to manage and reinforce priorities as a direction for future improvement in health screening service.