A Study on the Single Phase Voltage-Controlled Active Power Filter for Power Quality Improvement

전력품질 개선을 위한 단상 전압제어형 능동전력필터 시스템에 관한 연구

  • 손진근 (경원전문대학 전기제어시스템과)
  • Published : 2003.05.01

Abstract

In this paper, a single Phase voltage source voltage-controlled active power filter(APF) for power quality improvement was proposed. The proposed APF has the performance of harmonic suppression and unity power factor correction. The performance of harmonic suppression can be obtained by controlling the waveshape of the APF output voltage to be sine wave. And, unity power factor is controlled by the reactive power control loop of the APF output. Simulation and experimental results using diode rectifier showed that the voltage-controlled APF, unlike the current-controlled APF, can reduce the voltage harmonics as well as current harmonics. Also the results showed that the input dover factor and power quality were greatly improved.

Keywords

References

  1. L. A. Moran, J. W. Dixon, and R. R. Wallace, 'A three-phase active power filter operating with fixed switching frequency for reactive power and current harmonic compensation,' IEEE Trans. on Industrial Electronics, vol. 42, no. 4, pp. 402-408, Aug. 1995 https://doi.org/10.1109/41.402480
  2. Hirofumi Akagi, 'New trends in active filters for power conditioning,' IEEE Transactions on Industry application, vol. 32, no. 6, pp. 1312-1322, Nov./Dec. 1996 https://doi.org/10.1109/28.556633
  3. B. Singh, K. Al-Haddad, and A. Chandra, 'A review of active filters for power quality improvement,' IEEE Transactions on Industrial Electronics, vol. 46, no. 5, pp. 960-971, Oct. 1999 https://doi.org/10.1109/41.793345
  4. H. Fujita and H. Akagi, 'The unified power quality conditioner: The integration of series and shunt active filters,' IEEE Transactions on Power Electronics, vol. 13, no. 2, pp. 315-322, Mar. 1998 https://doi.org/10.1109/63.662847
  5. J.C. Wu and H. L. Iou, 'A new UPS scheme provides harmonic suppression and input power factor correction,' IEEE Transactions on Industrial Electronics, vol. 42, no. 6, pp. 629-635, Dec. 1995 https://doi.org/10.1109/41.475503
  6. B. Singh, K. AI-Haddad, and A. Chandra, 'A review of active filters for power quality improvement,' IEEE Transactions on Industrial Electronics, vol. 46, no. 5, pp. 960-971, Oct. 1999 https://doi.org/10.1109/41.793345
  7. Jin-Geun Shon, K. Shinohara, and K. Yamamoto, ' The Improvement of. Power Quality for Nonlinear Loads by Voltage Controlled Active Power Filter', in Conf. Rec. JIASC2002 Annu. Meeting, No.73, pp.361-364. August 2002
  8. 손진근 외3명, '회전자 저항 변동보상에 의한 유도전동기의 최대효율 제어기법', 대한전기학회 논문지, 제49P권, 제2호, pp.42-49, 2000.10
  9. 孫 珍劤, 篠原 勝次, 山本 吉朗, '無效電力および電壓高調波補償用電壓制御形アクティブフィルタ', 日本電氣學會半導體電力變換硏究會, SPC-02-106, pp.59-64, 2002.11