Digital Power Control of LLC Resonant Inverter for Microwave Oven (전자레인지용 LLC 공진형 인버터의 디지털 출력 제어)

  • Kang, Kyelyong;Kim, Heung-Geun;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.457-462
    • /
    • 2017
  • This paper proposes a digital power control of the LLC resonant half-bridge inverter for high power microwave oven application. Conventional half-bridge inverter for driving a microwave oven uses a hardware-based power control method which varies the frequency according to the AC source voltage. In this case, it is difficult to control the output power according to the variation of the load status of magnetron. The proposed power control consists of an instantaneous current generator and a current controller. Instantaneous current generator makes an instantaneous current reference from power command using input voltage information. Current controller controls input current which has an information of status of magnetron. The proposed power control does not require any compensation algorithm for the change of the load status of the magnetron and change of input voltage. The validity of the proposed method for the control of the change of input voltage and frequency is verified by both simulation and experiment.

A study on the power factor improvement of the Boost Forward Converter (BF 컨버터의 역률 개선에 관한 연구)

  • 임승하
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.3
    • /
    • pp.56-63
    • /
    • 1999
  • In this paper, we realize the active PFC(Power Factor Correction) system of BF (Boost Forward) converter with PWM-PFM control technique to control DC output voltage, and to control the input current with sinusoidal wave synchronized by the converter and inverter using power switching element, FET and IGBT. The control circuit of the suggested Boost converter is implemented with a microprocessor 80C196. After making the ratio of output voltage to current as 50V/1A and the duty ratio greater than 0.5. When input voltage is 30V and boost inductance is 1.1mH. We control the voltage changing rate according to the variation of load resistance using a PWM-PFM control technique. And finally we prove experimentally. PF can be improved up to 0.96 using the current shaping technique.

  • PDF

A Study on Industrial DNC System of Computer System (Computer System에 의한 산업용 DNC System에 관한 연구)

  • Park Young sik;Oh Chang-ju
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.2
    • /
    • pp.145-152
    • /
    • 2000
  • Some evolutional system has been used to promote the efficiency of the DNC(Direct Numerical Control) Controller. However, these are many inconvenience to this operator because it lacks harmony in interaction between the computer and the NC(Numerical Control) Controller. Also, there are some controversial points when data error occurs at the Data Input/Output. Accordingly, this paper explores a new Data Remote Control System. In this study, the NC Controller of the DNC network has to get full data by removing data error in this system. In this system, the main merits are easy manufacturing and the convenience of Data Input/Output. That is, remote control of the NC machine tool is possible without mutual interaction between the computer and itself.

  • PDF

Energy-saving optimization on active disturbance rejection decoupling multivariable control

  • Da-Min Ding;Hai-Ma Yang;Jin Liu;Da-Wei Zhang;Xiao-Hui Jiang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.850-860
    • /
    • 2023
  • An industrial control process multiple-input multiple-output (MIMO) coupled system is analyzed in this study as an example of a Loss of Coolant Accident (LOCA) simulation system. Ordinary control algorithms can complete the steady state of the control system and even reduce the response time to some extent, but the entire system still consumes a large amount of energy after reaching the steady state. So a multivariable decoupled energy-saving control method is proposed, and a novel energy-saving function (economic function, Eco-Function) is specially designed based on the active disturbance rejection control algorithm. Simulations and LOCA simulation system tests show that the Eco-function algorithm can cope with the uncertainty of the multivariable system's internal parameters and external disturbances, and it can save up to 67% of energy consumption in maintaining the parameter steady state.

Advanced Control of Three-Phase Four-Wire Inverters using Feedback Linearization under Unbalanced and Nonlinear Load Conditions (불평형 비선형 부하시 궤환선형화 기법을 이용한 3상 4선식 인버터의 제어 성능 개선)

  • Vo, Nguyen Qui Tu;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.333-341
    • /
    • 2013
  • In this paper, a feedback linearization control is proposed to regulate the output voltages of a three-phase four-wire inverter under the unbalanced and nonlinear load conditions. First, the nonlinear model of system including the output LC filters is derived in the d-q-0 synchronous reference frame. Then, the system is linearized by the multi-input multi-output feedback linearization. The tracking controllers for d-q-0-components of three-phase line-to-neutral load voltages are designed by linear control theory. The experimental results have shown that the proposed control method gives the good performance in response to the load conditions.

A Self-Tuning Fuzzy Controller for Torque and RPM Control of a Vehicle Engine

  • Seon, Kwon-Seok;Na, Seung-You
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1995.10b
    • /
    • pp.25-28
    • /
    • 1995
  • A Practical application of self-tuning fuzzy controller to a multi-input multi-output complex system of a vehicle engine is investigated. The ovjective is to design a controller to improve the transient performance in torque and RPM mode changes. For the performance improvement in the multivariable comples system, the self-tuning function of internal parameters is essential and practical. The measured output variables using different control schemes are compared the advanteges of the self-tuning fuzzy logic controller are better output performances and the effectiveness in the controller design using many parameters.

  • PDF

Systolic Architecture Vitrual Output Queue with Weighted Round Robin Algorithm (WRR 알고리즘 지원 시스톨릭 구조 가상 출력 큐)

  • 조용권;이문기;이정희;이범철
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.347-350
    • /
    • 2002
  • In the input buffer switch system, VOQ(Virtual Output Queue) archives 100% throughput. The VOQ with the systolic architecture maintains an uniform performance regardless of a number of Packet class and output port, so that it doesn't have a limitation of scalability. In spite of these advantages, the systolic architecture VOQ is difficult to change sorting order In this paper, we Proposed a systolic architecture VOQ which support weighted round robin(WRR) algorithm to provide with flow control service.

  • PDF

Design and Development of 200 W Power Converter (200 W급 LED 구동용 전원장치 설계 및 개발)

  • Kim, HyungJoong;Joung, Gyubum
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.242-243
    • /
    • 2012
  • In this paper, 200 W power supply for LED driver has been designed, analyzed, simulated and tested. Input AC voltage of 100VAC-240VAC was converted to DC voltage by high power factor converter. Output voltage was controlled, and output current was controlled by constant current when output current was reached to LED maximum rated current. By simulation and experimental test, voltage and current control and high power factor characteristics are verified.

  • PDF

Control of Power Distribution for Multiple Receivers in SIMO Wireless Power Transfer System

  • Kim, Gunyoung;Boo, Seunghyun;Kim, Sanghoek;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.4
    • /
    • pp.221-230
    • /
    • 2018
  • A method to control the power distribution among receivers by the load values in a single-input, multiple-output (SIMO) wireless power transfer (WPT) system is investigated. We first derive the value of loads to maximize total efficiency. Next, a simple, but effective analytical formula of the load condition for the desired power distribution ratio is presented. The derived load solutions are simply given by system figure of merits and desired power ratios. The formula is validated with many numerical examples via electromagnetic simulations. We demonstrate that with the choice of loads from this simple formula, the power can be conveniently and accurately distributed among receivers for most practical requirements in SIMO WPT systems.

Modeling of gas turbine control system (가스터빈 제어시스템의 모델링)

  • 이원규
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.2
    • /
    • pp.26-30
    • /
    • 2000
  • In this paper, we obtain a mathematical model of a gas turbine control system from experimental data. The gas turbine in Gunsan power plant is selected as controlled system. The recursive least square algorithm is used to model the plant. For parameter estimation, plant is assumed as second order system and forgetting factor is 0.98 and the period of input and output signal period is 1sec. As a result, input and output characteristics of real system and modeling are identified.

  • PDF