• 제목/요약/키워드: Inorganic samples

검색결과 468건 처리시간 0.024초

알루미늄 주조품의 미세조직 및 기계적 특성에 미치는 유·무기 화합물 중자의 영향 (Effects of Organic and Inorganic Binder Core on Microstructure and Mechanical Properties of Al Casting Products)

  • 신상수;김우천;김억수;임경묵;박정욱
    • 한국주조공학회지
    • /
    • 제33권4호
    • /
    • pp.147-156
    • /
    • 2013
  • The effects of core materials on the microstructure and mechanical properties of Al casting products have been investigated. The Al casting samples and cylinder head were fabricated by using organic and inorganic binder core respectively, and their microstructure and mechanical properties were evaluated. The Al casting samples fabricated by using inorganic core showed the better mechanical properties such as tensile strength and elongation than those of the Al casting samples fabricated by using organic core. That's because the Al casting samples contained small amount of pore defects and had fine microstructure compared with the Al casting samples fabricated by using organic core. Also, the use of inorganic core effectively reduced harmful gas emission and pollution.

춘천에서 2002년 봄철 황사 발생기간 동안에 채취된 미세분진 중 무기성분의 특성 (Characteristics of Inorganic Components in Fine Particles Collected at Chunchon during the Springtime Yellow Sand Occurrence Period in 2002)

  • 김희갑;정경미;김동진;이종태
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권4호
    • /
    • pp.333-339
    • /
    • 2002
  • Yellow sand (YS) storms were observed about ten times in the Korean peninsula during March and April in 2002. Twenty four hour fine particle (PM$\_$2.5/) samples were collected onto the 47 mm Teflon - coated quartz filters over 9 days during and after the events using the MiniVol Portable Air Sampler at a flow rate of 5 liters per minute. The highest PM$\_$2.5/ concentration measured during the YS period was 289 $\mu\textrm{g}$/㎥, which is 13 times higher than the lowest of the values for the samples collected during the non-yellow sand period. The filter samples were analyzed for inorganic ions using the IC, AAS and Autoanalyzer, and for metals using the ICP-MS. The results showed that the concentrations of some inorganic ions (e.g., Ca$\^$2+/ and SO$_4$$\^$2-/) and metals (e.g., Fe, Mn) of soil origin were elevated during the yellow sand events.

무기안료를 함유한 도료의 금속 원소 분석에 의한 유해성 분류에 관한 연구 (A Study on Hazard Classification by Metal Element analysis of Paints Containing Inorganic Pigment)

  • 한정희;이도희;이나루
    • 한국산업보건학회지
    • /
    • 제34권3호
    • /
    • pp.193-201
    • /
    • 2024
  • Objectives: Paints contain various types of metal substances. However, our review of MSDS (Material Safety Data Sheets) for paints found that their components were often kept secret or exact content information was otherwise not provided. We analyzed the metal elements in various inorganic pigment-based paints available in South Korea in this study and checked whether they contain hazardous metal substances as defined by the Occupational Safety and Health Acts. We investigated issues of health hazard classification related to the metal elements. The study is intended to contribute to strengthening the management of hazardous substances by suggesting improvements to MSDS. Methods: We randomly selected 19 samples that were predicted to contain hazardous inorganic pigments after reviewing MSDS among paints currently in use. The samples were analyzed using XRF (X-ray Fluorescence spectrometry), ICP_OES (Inductively Coupled Plasma-Optical Emission Spectroscopy) and SP-ICP-MS (Single Particle-ICP-Mass Spectroscopy). Results: The most common elements in the samples were Al (aluminum), Fe (iron), Ti (titanium), Ca (calcium), and Si (silica). One sample contained more lead than allowed by the limits. There were ten samples that could potentially contain nanoforms, seven samples that contained titanium dioxide, and six samples that contained complex inorganic color pigments (CICPs). Conclusions: Inorganic pigments in paints should be evaluated for hazards separately from other metallic compounds and reflected in the MSDS because they have different characteristics than other metallic compounds. These include particle size, crystal structure, and complex substances. The results of this study can be helpful for determining whether a paint contains sufficient hazardous metal compounds to affect its classification, and it can be a guideline for improving MSDS through comparative review and rationalization with the manufacturer's MSDS. This would make it possible to contribute to the management of chemical substances in the workplace through the proper MSDS disclosure of paints.

$\gamma$선조사에 의한 B종절연재료의 전기적 특성변화에 대한 실험적 연구 (The experimental study of $\gamma$ ray irradiation effect on electrical properties of B-kind insulator)

  • 천희영;성영권;이덕출
    • 전기의세계
    • /
    • 제18권2호
    • /
    • pp.15-20
    • /
    • 1969
  • The main focus of this paper is on the study of the .gamma. ray irradiation effect upon the electrical properties of a B-kind insulator which is one of the inorganic insulators. The mica is so typical of the B kind insulators as to be selected for a sample. DC, AC, and Impulse voltage is applied to the variable .gamma. ray irradiated dose samples with the constant time duration and the time variable samples with the .gamma. ray irradiated dose. The dielectric breakdown voltage and dielectric constant are measured from the samples and we get the experimental data that the dielectric breakown voltage variations are relatively large, but the dielectric constants are almost constant. The above conclusion is useful for the selection and application of the inorganic insulators under the irradiation effects, and we expect that the conclusion can apply to not only B-kind insulators but also the inorganic insulators.

  • PDF

글로우 방전/방출분광분석법에 의한 주철시료의 분석 (Analysis of Cast Iron by Glow Discharge Emission Spectrometry)

  • 조경행;우진춘;한명섭
    • 분석과학
    • /
    • 제6권3호
    • /
    • pp.297-305
    • /
    • 1993
  • 글로우 방전 방출원을 다색화장치에 연결시켜 개발된 글로우방전/방출분광법으로 탄소의 농도가 수 퍼센트에 이르러 스파크방출분광법으로서는 분석이 곤란한 주철시료를 분석하고 정확성을 검토하고자 하였다. 알곤가스 압력, 전압, 방전시간 등 glow discharge lamp(GDL)의 방전조건을 최적화시키고 이 조건에서 두 종류의 주철 표준시료(BAS, LECO)에 대해 원소별 방출 복사선의 세기와 농도의 상관관계를 조사하였다. Mn, Si, P, S 등 대부분 원소의 검정곡선이 양호한 직선성을 보여 주었고 탄소의 경우에는 표준시료의 종류에 따라 절편과 기울기값이 미소하게 계통적인 차이를 나타내었다.

  • PDF

경기북부지역 지하수의 지역별 미량무기물질 함유실태 조사연구 (A survey on the content of inorganic materials in ground-water of Northern Gyeonggi area)

  • 오조교;손진석;배용수;정은희;박진호;황선민;정연훈
    • 환경위생공학
    • /
    • 제19권1호
    • /
    • pp.8-16
    • /
    • 2004
  • Ground water samples were collected from residential, green" industrial, landfill and mining area and analyzed for 23 inorganics from March to October in 2002. The results are as follows; 1. The detection frequencies of inorganic materials such as As, Ba, B, Mo, Ca, Mg, Al, Cu, Fe, Mn, Zn, Na, K were 7.2∼77.1% which showed that these inorganics were detected in many ground waters. 2. The detection frequencies of 7 inorganics(Cd, Cr, Ph, Se, Sb, Be, Tl) were commonly low at ranging from 0.42 to 2.5%. These inorganics were contained in ground water partially. 3. Three inorganics such as Hg, Ni, Ag were not detected in any ground-water samples. 4. Compared to the other areas, ground water samples from landfill area contained greater concentration in many inorgainics and then showed higher levels in industral, residential, mining and green area in order. 5. Compared to noted concentrations of bottled water, inorganic minerals including Ca, Mg, Na, K related to taste were fluent in target samples. The results showed that the average concentrations of Mg, Na, K were 4.0 mg/l, 14.7 mg/l, 1.5 mg/l respectively. 6. The concentrations of inorganics such as Sb, Ba, Mo, Be, Tl, K in some ground water samples exceeded the water quality standards of WHO, the US and UK. Especially, Ba, Mo, K also showed relatively high detection frequencies so these inorganics need to be considered as analytes in Korea Drinking Water Regulation in further study.

Differential Pulse Polarography에 의한 무기물 시료 중 Germanium의 미량 분석에 관한 연구 (A Study on the Trace Analysis of Germanium in Inorganic Matrices by Differential Pulse Polarography)

  • 신호상;오윤숙;신학수
    • 분석과학
    • /
    • 제9권3호
    • /
    • pp.253-261
    • /
    • 1996
  • 무기시료 중에 게르마늄의 DPP에 의한 미량 분석법이 연구되었다. 1, 2, 3-트리하이드 록시벤젠이 함유된 과염소산 용액 중에 게르마늄(IV)의 환원 피크가 -0.45V(기준전극 Ag/AgCl)에서 나타났고, 이 피크의 높이는 농도에 직선성을 보였다. 게르마늄 분석시에 감도 및 정밀도에 영향을 주는 인자들이 조사되었고, 최적 조건하에서 검출한계는 1ng/ml였다. 무기물 시료들은 potassium pyrosulfate를 사용한 용융법으로 분해하였다. 게르마늄 검출시 Se(IV), Pb(II), As(III)의 간섭에 대한 조사가 있었고, 이들 간섭은 10M HCl용액 중에서 $CCl_4$로 추출함으로써 해결할 수 있었다. 무기물 시료들 (Pb bf. dust, Cu bf. dust, 편마암, Cu anode slime)중의 게르마늄 함량은 위의 방법으로 정량되었다.

  • PDF

이온크로마토그래피를 활용한 무기산류 정도관리 방법 연구 (A Study on Quality Control of Inorganic Acids using Ion Chromatograph)

  • 박해동;박승현;정기효
    • 한국산업보건학회지
    • /
    • 제31권1호
    • /
    • pp.22-30
    • /
    • 2021
  • Objectives: The objectives of this study were to develop a quality control protocol of inorganic acids using ion chromatograph and to evaluate analytical proficiency of the legally designated agencies. Methods: This study prepared inorganic acid samples by injecting three anion certified solutions (chloride, nitrate, and sulfate) on the quartz filters. To investigate the storage stability and concentration consistency of the samples, 240 samples for each anion were tested at weeks 0, 2, 4, 8, 12, and 16 while storing at 4℃ and 25℃. To evaluate analytical proficiency, two separate testings were administrated for six skilled analysts and 46 analysts affiliated with legally designated agencies. Results: Average recoveries of the three ions after 16 weeks of storage were fairly high (over 95%). In addition, average recoveries (chloride = 97%, nitrate = 96%, and sulfate = 103%) after 16 weeks of storage at low temperate were relatively higher than those (94%, 93%, and 98%) at room temperature. The coefficients of variation (CV) for the three ions were less than 5% except for the sulfate sample at 5.56 ㎍ (CV = 12.4%). The average ratios of the concentration values analyzed by the legally designated agencies to the injected concentrations were close to 1. However, their CVs were relatively greater (chloride ≤ 49%, nitrate ≤ 14%, and sulfate ≤ 28%), which implies a need for quality control. Conclusions: The quality control protocol used in this study for the three inorganic acids can be utilized in the quality control for ion chromatography.

가평지역의 지하수중에 함유된 미네랄성분 조사에 관한 연구 (A Survey on the Characteristics of Mineral Inorganic in Ground-Water of Gapyeong County)

  • 박경수;김종찬;오조교;권경안;정은희;황선민
    • 환경위생공학
    • /
    • 제20권1호
    • /
    • pp.55-63
    • /
    • 2005
  • Ground water samples of 275 were collected from Gapyeong county which it contained six-eup and myeon and analyzed for 12 mineral inorganics extending from March to October in 2004. Among the inorganics, Calcium, Magnesium, Sodium, Potassium, Copper and Zinc had more than $70\%$ of detection frequencies, which coincided with essential inorganics required by the human body. The average values of inorganic contents by sampling sites were insignificant. Fluorine contents of 8 samples, $2.9\%$ of 275 samples, exceeded KDWR, and it was considered to be affected by a base rock being made up granite and gneiss because there were not polluting sources around. It is necessary to find out relation between geological characteristics and mineral inorganics in ground water through the further investigation. Compared to noted concentrations of bottled water, inorganic minerals including Calcium, magnesium, Sodium and Potassium related to taste were fluent double in target samples and those average concentrations were 14.80, 3.80, 7.60, and $2.31\cal{mg/L}$ respectively.

Analysis of Inorganic Anions in Various Drinking Waters by Capillary Electrophoresis

  • Choi, One-Kyun;Cho, Jae-Sun
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.835-841
    • /
    • 1995
  • The quantitation of inorganic anions in various drinking waters were investigated using capillary electrophoresis(CE) and the results were compared with ion chromatography(IC). With CE, in contrast to IC, was demonstrated rapid analysis, good efficiency, a low detection limit and the low comsumption of a solvent and samples. CE analysis was used 5 mM sodium chromate(pH 8.0) containing 20 mM tetraalkylammoniumbromide at -25kV applied voltage with indirect UV detection at 254 nm. This results in exceedingly short analysis time within 3 min. with efficiencies approaching 200,000 theoretical plates. The coefficients of variants of migration time are less than 0.8% and those of peak area are less than 2.3%. Detection limits for quantitative determination were 300 ppb-50 ppm level. These optimum conditions are applicable to various samples without pretreatment.

  • PDF