• 제목/요약/키워드: Ink Leakage

검색결과 21건 처리시간 0.023초

근관충전방법이 근관폐쇄성에 미치는 영향에 관한 실험적 연구 (EVALUATION OF THE APICAL SEAL PRODUCED BY THE SINGLE CONE FILLING AND BY THE LATERAL CONDENSATION)

  • 박준일;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제9권1호
    • /
    • pp.51-57
    • /
    • 1983
  • 64 multi-rooted teeth (198 canals) were tested in vitro to evaluate the apical seal produced by the single cone filling and lateral condensation with sealer and without sealer. The obturated teeth were immersed in India ink, decalcified, and cleared. The degree of ink penetrated into the canal provided a measure of the apical seal. The results were as follows: 1. The lateral condensation with sealer provided statically less apical leakage than the other obturating techniques used in this study. 2. The single cone filling provided good apical sealing. 3. The lateral condensation without sealer provided most apical leakage than any other techniques used in this study. 4. The degree of apical leakage was not related to the visual appearence of the adaptation of the gutta percha filling in cleared teeth.

  • PDF

크렉 방지를 위한 잉크젯 프린트 헤드 강건 설계 (Design of thermal inkjet print head with robust and reliable structure)

  • 김상현
    • 문화기술의 융합
    • /
    • 제8권2호
    • /
    • pp.337-342
    • /
    • 2022
  • 최근 프린팅 기술은 디스플레이나 연료전지를 포함한 IT 분야에 폭넓게 사용되고 있지만 핵심 부품인 프린터 헤드의 박막을 적층하는 제조공정에서 발생하는 잔류응력 및 열응력으로 인해 기판이 변형되거나 노즐층이 파손되어 잉크가 새거나 원하는 영역으로 토출되지 않는 문제가 발생하고 있다. 따라서 본 논문에서는 보다 견고하고 신뢰할수 있는 구조를 가진 열전사 잉크젯 프린트 헤드 형상을 제안하고자 한다. 기판과 노즐층의 변형을 줄이기 위해 리브, 기둥, 지지벽 및 개별 피드홀과 같은 다양한 형태의 잉크젯 프린트 헤드 구조가 설계되었으며, FEA 해석을 통해 타당성을 검증하였다. 해석 결과 헤드의 최대 응력 및 노즐층 변형이 최소 40~50%로 급격히 감소하였으며 기둥 및 지지벽 형태의 프린터 헤드를 제작하여 노즐층 변형에 의한 균열 및 잉크 누출이 없는 것을 확인하였다. 따라서 제안된 헤드 형상이 정상 방향의 잉크 토출에 기여하며 대면적 프린팅 기술에도 적용될 수 있을 것으로 기대된다.

수종(數種) 근관충진재(根管充眞材)의 근관폐쇄성(根管閉鎻性)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON SEALING ABILITY OF VARIOUS ROOT CANAL SEALERS)

  • 박선희;민병순;최호영;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제13권1호
    • /
    • pp.113-120
    • /
    • 1988
  • The purpose of this study was to evaluate and compare the sealing ability of ZOE, FR and AH-26. Seventy two upper and lower anterior and premolor teeth were randomly selected and instrumented in a conventional method with K-file. After instrumentation and dry the canal, the teeth were divided into 3 groups and twenty four teeth in each group were filled with ZOE, FR, and AH-26 respectively. All the specimens were immersed into Indian Ink and decalcified in nitric acid and cleared in methyl salicylate. The apical leakage was evaluated by measuring the degree of ink penetration with caliper at the intervals of 1 day, 7 days and 14 days. The results were as follows; 1. In AH-26 and FR groups, there was increase in penetration related to increased time of immersion in the ink. 2. FR group showed the least penetration in 3 groups. 3. Statistics showed that there was no significant difference among the each sealer groups.

  • PDF

만곡근관에서 Thermafil의 근단폐쇄성에 관한 실험적 연구 (APICAL SEALING OF THERMAFIL OBTURATORS IN CURVED CANALS)

  • 하주희;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.671-684
    • /
    • 1995
  • The purpose of this study was to compare the apical sealing ability, overfilling and obturation of lateral canals using two gutta-percha techniques: Thermafil obturators and cold lateral condensation. Eighty numbered epoxide blocks with one major and five lateral canals were divided into four experimental groups and obturated according to experimental groups. Four experimental groups were as follows: Group 1 : Filling with Thermafil plastic obturators and sealer(ThermaSeal) Group 2 : Filling with Thermafil plastic obturators only, without sealer(ThermaSeal) Group 3 : Fillng using lateral condensation with sealer(AH-26) Group 4 : Fillng using lateral condensation without sealer(AH-26) All the blocks were stored in 100% relative humidor at room temperature for 7 days. Each block was placed in centrifuge tube filled with India ink, and then centrifuged for 20 minutes at 3,000 rpm. Apical leakage was measured from the apical foramen to the most coronal level of dye penetration in millimeter under a stereoscope. The length of gutta-percha and sealer in each of the lateral canals was measured, too. The presence or absence of overfilling of gutta-percha and sealer was recorded. The data was analyzed by one-way ANOVA. The obtained results were as follows: l. Apical dye leakage was almost: not occurred in Group Willed with Thermafil and sealer) and Group 3(filled using lateral condensation with sealer), and there was no significant difference in linear leakage between two groups(p>0.01). 2. In both Thermafil and lateral condensation groups, linear leakage of Group I, 3(filled with sealer) was less than that of Group 2, 4(filled without sealer), and there was no significant difference in linear leakage between Group 1, 2, 3(p> 0.01). 3. Overfilling during obturation of Group 1, 2(filled with Thermafil) was more than Group 3, 4(filled using lateral condensation), and there was no significant difference between groups(p> 0.05). 4. Groups filled with Thermafil had significantly more gutta-percha than groups filled using lateral condensation in all lateral canals(p <0.01), the total length of gutta-percha and sealer found in all lateral canals were similar in Group 1 and Group 3.

  • PDF

수종의 apical plug 재료의 근단 폐쇄성에 관한 실험적 연구 (EVALUATION OF APICAL PLUG MATERIALS USED FOR THE CONTROL OF EXTRUSION OF HIGH-TEMPERATURE THERMOPLASTICIZED GUTTA-PERCHA)

  • 허은정;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제19권1호
    • /
    • pp.205-216
    • /
    • 1994
  • The purpose of this study is to evaluate of apical plug materials for the contral of extrusion and sealing ability of high-temperature thermoplasticized gutta-percha in plastic root canal blocks. Seventy seven plastic blocks with canal preformed were instrumented with # 50K file 1 mm beyond apical foramen. Blocks were randomly divided into 5 groups of 15 blocks each. Group 1 was filled by high-temperature thermoplasticized gutta-percha only. The another 4 groups were placed with apical plug materials each other and then remaining space was back filled with high temperature thermoplasticized gutta-percha Apical plug materials were used as follows; Group 2: Thermoplasticized gutta-percha (Thermoplasticized gutta-percha group) Group 3 :. Calcium hydroxide powder (Calcium hydroxide group) Group 4 : Silver point (Silver point group) Group 5 : Gutta-percha cone softened by chloroform (Gutta-percha cone group) All the blocks were stored in 100 % relative humidor at room temperature for 14 days. Filling material extruded was removed carefully and then weighed in analytic balance. Each block was placed in centrifuge tube filled with India ink, and then centrifuged for 20 minutes at 3,000 rpm. Apical leakage was measured from the apical foramen to the most coronal level of dye leakage in millimeter by two examiners under a stereoscope. The data were analysed statistically by Student's t-test The obtained results were as follows; 1. The amounts of material extruded through the foramen decreased in all of groups used apical plug materials (P<0.01). 2. Silver point group and gutta-percha cone group were similar linear leakage to high-temperature thermoplasticised gutta-percha technique only (P>0..5). 3. Calcium hydroxide group and thermoplasticized gutta-percha group showed more liner leakage than high-temperature thermoplasticized gutta-percha only (P<0.01, P<0.05). 4. High-temperature thermoplasticized gutta-percha technique with silver point and gutta-percha cone as apical plugs showed less linear leakage and less extrusion of filling material.

  • PDF

The effect of thermocycling on the bonding of different restorative materials to access opening through porcelain fused to metal restorations

  • Al-Moaleem, Mohammed M.;Shah, Farhan Khalid;Khan, Nausheen Saied;Porwal, Amit
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권4호
    • /
    • pp.186-189
    • /
    • 2011
  • PURPOSE. Porcelain fused to metal (PFM) crowns provide the best treatment option for teeth that have a large or defective restoration. More than 20% of teeth with PFM crowns or bridges require non-surgical root canal treatment (NSRCT). This may be due to the effect of restorative procedures and the possible leakage of bacteria and or their by-products, which leads to the demise of the tooth pulp. Thus, this study was planned to compare the ability of the restorative materials to seal perforated PFM specimens. MATERIALS AND METHODS. The study evaluates the ability of amalgam, composite or compomer restorative materials to close perforated PFM specimen's in-vitro. Ninety PFM specimens were constructed using Ni-Cr alloys and feldspathic porcelain, and then they were divided into 3 groups: amalgam (A), composite + Exite adhesive bond (B) and compomer + Syntac adhesive bond (C). All the PFM samples were embedded in an acrylic block to provide complete sealing of the hole from the bottom side. After the aging period, each group was further divided into 3 equal subgroups according to the thermocycling period (one week for 70 cycles, one month for 300 cycles and three months for 900 cycles). Each subgroup was put into containers containing dye (Pelikan INK), one maintained at $5^{\circ}C$ and the other at $55^{\circ}C$, each cycle for 30 sec time. The data obtained was analyzed by SPSS, 2006 using one way ANOVA test and student t-test and significant difference level at (P<.01). RESULTS. The depth of dye penetration was measured at the interfaces of PFM and filling materials using Co-ordinate Vernier Microscope. The lowest levels of the dye penetration for the three groups, as well as subgroups were during the first week. The values of dye leakage had significantly increased by time intervals in subgroups A and C. CONCLUSION. It was seen that amalgam showed higher leakage than composite while compomer showed the lowest level of leakage.

근관충전용 글라스 아이오노머 시멘트의 근단 폐쇄성과 치질 적합성에 관한 연구 (EVALUATION OF APICAL MICROLEAKAGE AND ADAPTATION TO THE DENTINAL WALL OF THE GLASS-IONOMER ROOT CANAL CEMENT)

  • 김현아;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.596-608
    • /
    • 1997
  • The purpose of this study was to compare the apical leakage and adaptation to the dentinal wall of a glass ionomer root canal cement(Ketac-Endo) with those of AH-26 and Tubli-Seal. 102 single-rooted teeth were insrumented with step-back technique and randomly divided into four groups according to kinds of root canal cements: Ketac-Endo, AH-26, Tubli-Seal, and no root canal cement. Four experimental groups were as follows; Group 1 : Filling with gutta-percha and Ketac-Endo Group 2 : Filling with gutta-percha and AH-26 Group 3 : Filling with gutta-percha and Tubli-Seal Group 4 : Filling with gutta-percha without root canal cement All the specimens were obturated with lateral condensation technique, and stored in 100% humidity for 4 days. 20 teeth in each group were placed in centrifuge tube filled with India ink, and then centrifuged for 20 minutes at 3,000 rpm. And they were evaluated for linear dye leakage using a stereoscope and analyzed by one-way ANOVA. 22 teeth were split longitudinally and evaluated the adaptation to the dentinal wall using scanning electron microscope(4 teeth in each group) and stereoscope(2 teeth in 1, 2, 3 group). The obtained results were as follows ; 1. In case of not used root canal cement(Group 4), there was showed much degree of dye penetration comparerd with used root canal cements (Group 1, 2, 3)(P<0.01). 2. In the case of used root canal cements(Group 1, 2, 3), there was no significant difference in linear leakage in groups(P>0.01). 3. In the case of used root canal cements(Group 1, 2, 3), there was showed intimate adaptation to the dentinal wall independent on kinds of root canal cements. 4. Fractured surfaces indicated failure of cohesion in Ketac-Endo, and failure of adhesion to dentine in AH-26 and Tubli-Seal. 5. According to similar apical leakage and adaptability to the dentinal wall to another root canal cements, it is possible to be used glass-ionomer cement as root canal cement.

  • PDF

합착방법(合着方法)에 따른 복합(複合)레진 인레이의 변연폐쇄효과(邊緣閉鎖效果) (THE MARGINAL SEALING EFFECT OF COMPOSITE RESIN INLAYS ACCORDING TO THE LUTING TECHNIQUES)

  • 문영덕;조규징
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.121-132
    • /
    • 1991
  • The purpose of the study was to evaluate the marginal sealing effect of composite resin inlays according to the luting techniques and compare them to the conventional direct resin filling technique. 90 cavities of class V were prepared on the buccal surface of 90 extracted molar teeth, which were divided into four groups. Cavities of control group were directly filled with Scotchbond 2 and P - 50, and those of composite resin inlay groups were luted with one of the followings: Adhesive bond followed by Adhesive cement, All bond followed by Adhesive cement, Fuji - ionomer type L All the specimens were immersed in India ink dye solution for 7 days at $37^{\circ}C$ incubator after thermocycling between $5^{\circ}C$ and $60^{\circ}C$ and longitudinally sectioned with diamond disk inot two parts All the specimens were observed at the occlusal and gingival margins and statistical analysis was performed. The results were as follows: 1. Groups filled with composite resin inlay showed less marginal leakage than the group directly filled(p<0.01). 2. There was no significant difference in marginal leakage between composite resin inlay groups luted with Adhesive bond followed by Adhesive cement and the group luted with All bond followed by Adhesive cement(p>0.05). 3. At occlusal margins, Composite resin inlay group luted with Adhesive bond followed by Adhesive cement showed less marginal leakage than the group luted with Fuii ionomer type I(p<0.01). At gingival margins, composite resin inlay group luted with All bond followed by Adhesive cement showed less marignal leakage than the group luted with Fuji ionomer type I(P<0.01).

  • PDF

액체누설 감지용 테이프형 필름센서 (Tape-Type Liquid Leakage Film Sensor)

  • 유동근;김경신;유홍근;한국희;김동준;김정현;한상호;조광섭
    • 한국진공학회지
    • /
    • 제20권2호
    • /
    • pp.146-154
    • /
    • 2011
  • 접착테이프 형태의 액체누설 감지 필름 센서와 이를 이용하고 경보 장치를 포함한 감지 시스템을 개발하였다. 액체누설 감지 필름형 테이프 센서는 베이스 필름층, 전도성 라인층, 보호 필름층으로 구성되며, 테이프의 두께 $300{\sim}500{\mu}m$, 폭 3.55 cm, 그리고 단위 테이프의 길이는 200 m이다. 전도성 라인층의 필름에는 3개의 전도선과 1개의 저항선이 있다. 이들은 도전성 은나노 잉크를 전자인쇄방식으로 설치한다. 이들 저항선과 전도선 사이에 액체가 누설되어 전기적으로 상호 통전되면, 두 선사이의 저항변화를 전압의 변화로 계측하여 누설 위치를 감지한다. 물을 포함한 전도성 액체에 대한 누설 위치 감지에서 길이 200 m에서 오차 범위는 ${\pm}1m$ 이내이다.

근광충전방법에 따른 post space형성후의 근관폐쇄성에 관한 실험적 연구 (CORONAL DYE PENETRATION OF THE APICAL FILLING MATERIALS AFTER POST SPACE PREPARATION)

  • 윤수한;권오양
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.812-817
    • /
    • 1995
  • Endodontically treated teeth are usually restored for crown protection, aesthetics, and prevention of root canal recontamination. Restoration of these teeth, however, often requires intracanal posts. Various depths and techniques have been recommended for the preparation of post space. Therefore the purpose of this study was to evaluate the effect that pst preparation has on the coronal seal by linear dye penetration of root canals obturated by lateral condensation, vertical condensation, and thermafil techniques. Forty canals of roots of incisors and canines were cleaned and shaped with the use of a step-back technique. Thirty canals were obturated, 10 each with lateral, vertical, and thermafil techhniques. Five root canals were obturated without a root canal sealer and served as positive controls. Another five root canals were obturated, and their coronal half was sealed with sticky wax and served as negative controls. The apical 5 to 6mm of the filling materials were exposed to india ink for 48 hours. The depth of dye penetration was measured in all groups and statistically analyzed (ANOVA). The results were as follows. 1. The apical plugs in the thermafil groups had the highest degree of coronal dye leakage. 2. The group filled by vertical condensation technique had the lowest degree of coronal dye leakage. 3. No significant statistical difference was found in the amount of coronal dye leakage in canals filled by lateral condensation versus those filled by the veritcal condensation technique. 4. Significant statistical differences in coronal dye penetration were found between the canals filled by thermafil and those filled by the lateral or vertical condensation techniques (p<0.05).

  • PDF