Ji Hyun You;Hae Jin Jeong;Sang Ah Park;Se Hee Eom;Hee Chang Kang;Jin Hee Ok
ALGAE
/
제39권2호
/
pp.109-127
/
2024
High production and efficient harvesting of microalgae containing high omega-3 levels are critical concerns for industrial use. Aeration can elevate production of some microalgae by providing CO2 and O2. However, it may lower the production of others by generating shear stress, causing severe cell damage. The mixotrophic dinoflagellate Gymnodinium smaydae is a new, promising microalga for omega-3 fatty acid production owing to its high docosahexaenoic acid content, and determining optimal conditions and methods for high omega-3 fatty acid production and efficient harvest using G. smaydae is crucial for its commercial utilization. Therefore, to determine whether continuous aeration is required, we measured densities of G. smaydae and the dinoflagellate prey Heterocapsa rotundata in a 100-L semi-continuous cultivation system under no aeration and continuous aeration conditions daily for 9 days. Furthermore, to determine the optimal conditions for harvesting through centrifugation, different rotational speeds of the continuous centrifuge and different flow rates of the pump injecting G. smaydae + H. rotundata cells into the centrifuge were tested. Under continuous aeration, G. smaydae production gradually decreased; however, without aeration, the production remained stable. Harvesting efficiency and the dry weights of omega-3 fatty acids of G. smaydae + H. rotundata cells at a rotational speed of 16,000 rpm were significantly higher than those at 2,000-8,000 rpm. However, these parameters did not significantly differ at injection pump flow rates of 1.0-4.0 L min-1. The results of the present study provide a basis for optimized production and harvest conditions for G. smaydae and other microalgae.
전신 뼈검사는 골수염과 골절 및 원발성 암의 조기 발견 등골 병변에 대해 높은 민감도와 해상도를 가진 검사이며, 핵의학 검사 중 가장 많은 비중을 차지하고 있다. 그러나 최저 계수치를 제외한 평가 기준이 마련되어 있지 않다. 따라서, 본 연구에서 전신 뼈검사에서 정량적인 평가 지표를 나타낼 수 있는 방법을 분석해보고자 하였다. 본 연구는 2014년 4월부터 2014년 9월까지 본원을 내원한 특이 골병변소견이 없는 환자 30명을 대상으로 GE INFINIA 장비에서 진행하였다. 환자의 전신계수와 허리뼈를 관심영역으로 하여, 계수치를 측정하였으며, 허리뼈 각각의 신호평균 값과 표준편차를 구하여, 대조도 대 잡음비(Contrast to Noise Ratio, CNR), 신호 대 잡음비(Signal to Noise Ratio, SNR)를 산출하였고, 팬텀 실험을 통해 검사 속도 변화에 따른 각각의 수치와 조직등가물질을 이용하여 복부 두께에 따른 수치를 비교 하였다. 그리고, 판독의 2명과 5년 이상의 경력을 가진 숙련된 방사선사 5명이 각각 10점 척도로 하여, Blind test로 육안적인 분석치와 정량적인 산출치 간의 상관관계를 분석하였다. 환자의 전신 계수치와 관심영역의 계수치는 Blind test를 통한 육안적인 분석치와 유의한 상관관계를 보이지 않았다(P>0.05). 대조도 대 잡음비와 신호 대 잡음비는 육안적인 분석치와 유의한 상관관계를 보였다(P<0.05). 팬텀 실험에서는 검사 속도가 느릴수록, 조직등가물질의 두께가 얇을수록 각 수치는 향상되는 것을 보였으며, 지연검사에서 영상의 질이 향상됨을 확인하였다. 현재 전신 뼈검사에서 최저 계수치를 제외한 평가 기준이 마련되어있지 않다. 이에 본 연구에서는 대조도 대 잡음비 및 신호 대 잡음비를 이용하여 Blind test와의 유의한 상관관계를 확인 할 수 있었으며, 검사 속도가 영상의 질을 좌우하는 인자라는 것을 수치를 통해 확인하였다. 본 연구에서는 동일한 주입량, 동일한 검사 속도 등 동등한 조건에서의 평가를 진행하였지만, 환자의 생리적 기능과 수분 섭취량 등에 따라 모든 특성을 고려하는 것에 한계가 존재한다. 그러나 객관적으로 정량적 수치를 제시하여, 유의한 평가 지표를 입증하였다는 데에 학술적 의미가 있을 것으로 사료된다.
작업 편이성을 높일 수 있는 원통형 종이포트를 일정한 크기로 생산하여 연속적 공급이 가능한 원통형 종이포트 제조장치를 개발하고, 장치의 성능시험을 수행하였다. 원통형 종이포트 제조장치는 상토공급부, 종이 공급부, 종이 접착부, 종이포트 절단부로 구성되어 종이포트제조를 위한 상토공급부터 종이포트 절단까지의 공정이 연속적으로 이루어지도록 하였다. 상토 함수율에 따른 적정 상토공급압력시험에서는 상토를 공급하는 진공압이 높을수록 종이포트의 경도와 가밀도가 높게 나타났으며, 수분 함수율이 높아질수록 경도와 가밀도는 증가하다가 낮아지는 경향을 나타내어 포트제조부로 상토를 공급하기 위한 적정 함수율 및 공기압은 50%~60%와 0.5 Mpa인 것으로 판단된다. 제조장치의 성능과 고형접착제에 의한 종이 접착시간을 고려하였을 때, 종이의 원통성형이 이루어지고 가이드부와의 유착없이 연속적인 공정이 이루어질 수 있는 적정 온도는 $150^{\circ}C^{\sim}160^{\circ}C$인 것으로 판단된다. 원통형 종이포트 절단칼날의 최적 절단각도를 구명하기 위한 시험에서는 절단 속도와 작업의 안전성을 고려하여 최소 기울기인 $30^{\circ}$에서 깨끗한 단면을 나타내는 일자칼날을 사용하는 것이 적합할 것으로 판단된다. 원통형 종이포트 제조장치의 성능시험에서 종이포트의 길이는 설정한 길이로 균일하게 제조되었으며, 종이접착 및 상토공급 등 준비 시간을 제외한 종이포트(직경: 40mm, 길이: 40mm) 제조 작업성능은 3300개/hr로 나타났다.
본 연구는 강관다단 그라우팅 공법의 Seal재의 배합비 결과에 대한 연구이다. 현재 국내에는 Seal재의 적정 겔화시간 및 초결시간에 대한 명확한 기준이 없는 실정이며, 이를 확인할 수 없어 품질관리에도 어려움이 있다. 이에 Seal재의 배합비를 4가지로 구성하여 실내 실험을 진행하였으며, 이를 통해 겔화시간 및 블리딩양을 확인하였다. 또한 비카트침 관입 실험을 통해 초결시간을 확인하고 각 배합비의 비교를 진행하였다. 그리고 W/C 120%에 대한 추가적인 실험을 통해 교반 속도와 시간이 Seal재에 미치는 영향을 파악하였다. 실내실험을 기반으로 총 3가지의 배합비에 대한 현장 실험을 진행하였으며, 시료의 초결시간 확인 및 본주입을 통한 구근 형성 크기와 강도를 비교하였다. 비교 결과 W/C가 낮을수록 강도가 강하고 구근의 크기가 크며, 초결 시간이 빠르게 나타나는 결과를 확인하였다. 겔화시간과 초결시간 결과를 통해 실제 현장에 적용 시 W/C 120%의 배합비가 가장 적절할것으로 나타났다.
본 연구에서는 IR과 CR의 블렌딩을 통하여 물성 개선 및 내구 성능 개선을 목적으로 IR/CR의 비율을 다양하게 블렌딩하여 제조한 고무시료의 가교 특성, 물성 변화, Morphology의 변화 및 화학적 특성을 조사하였다. 한편으로 블렌딩 된 고무에 다양한 조건으로 염소 표면처리를 하였을 때 고무시료의 Morphology를 관찰하고 마찰 시험을 통해 염소의 표면처리가 마찰계수에 미치는 영향을 조사하였다. 고무의 가교특성에서는 CR의 함량이 증가할수록 가교 속도가 감소하였으나 가교밀도는 일정하였고,경도, 모듈러스가 증가하였는데 이것은 가교특성의 변화와 밀접한 관계가 있으며, 가교 반응의 활성화에 의한 결정화 영향으로 기계적 강도가 증가하는 것으로 나타났다. 노화 후 물성 변화는 IR/CR Blend가 상호 기계적 물성의 단점을 보완하여 노화에 의한 물성 변화를 감소시키는 역할을 하는 것으로 나타났다. 염소 표면처리 한 시료의 노화 전, 후 상태물성의 변화는 감소하였다. 현미경 사진 관찰 결과 CR 함량 증가에 따라 표면 분산도가 증가함을 알 수 있었다. 염소 표면처리된 고무의 표면은 일정한 방향으로 균일하게 표면처리되었고 매끄러움과 광택이 증가하였다. 고무 표면의 개질 정도는 표면염소잔류량으로 확인할 수 있었으며, 마찰계수는 고무와 결합된 염소함량에 의존하는 것으로 나타났다. CR 함량이 10 - 40 phr까지는 표면처리 초기단계에서 마찰계수가 급격히 감소하였으나, 처리용액의 염소농도가 증가할수록 마찰계수의 감소는 둔화되었고, CR 함량이 50 phr에서는 처리용액의 염소농도 변화에 따라 마찰계수의 감소가 둔화되었다.
본 연구에서는 함산소기재 중 MTBE를 휘발유에 첨가하여 산소함량(0, 1.0, 2.3 및 2.7 wt %)의 변화에 따라 MPI 및 GDi 차량에서 배출되는 유해한 배출가스와 연비를 분석하였다. 국내 및 미국의 연비시험방법인 FTP-75 mode와 HWFET mode를 적용하였다. CO, NMHC, NOx 배출량은 산소함량의 변화에 따라 미미한 차이는 있었지만 상관관계는 없었다. FTP-75 mode에서 CO2 배출량은 산소함량의 변화에 따라 증감의 경향성은 없었다. 하지만 차량이 예열된 상태이고 고속 운전영역이 포함된 FTP-75 mode의 phase-3와 HWFET mode에서는 산소를 함유한 연료의 CO2 배출량이 적었다. 입자개수 배출량은 산소함량과 음의 상관관계를 보였으며 산소함량 2.3 wt %에서 가장 적었다. 카본발란스법에 의해 계산된 연비는 산소를 함유한 연료가 높았으며 2.3 wt %에서 가장 높았다.
l. Backgrounds of Studies Cerebrovascular accident. one of the three major causes of death among audults with cardiopathy and malignancy, has been on the increase in korea while it is on the decrease in European countries and Japan. Types of stroke undergo changes caused by prolongment of life expectancy. and social and economic variety. More patients of ischemic stroke show a tendency to increase now than those of hemorrhagic stroke in the past. Many clinical studies on medical cerebrovascular and oriental stroke of paralysis have been published. but few clinical studies on therapeutics of integrated oriental and western medicine are to be found. So I have made an attempt to study clinical observations and therapeutic responses of ischemic stroke under integrated oriental and western medicine. 2.Methods. Among the patients admitted into the clinic of Joong-Poong, Woo-Suk University Hospital from May 1. 1993 until April 30. 1994 those 56 patients who were diagnosed as ischemic stroke on Computed Tomography(CT) and showed no dubious symptom after examination of coagulation and bleeding time were classified into the following six steps and treated: l)diagnosis 2)emergency treatment 3)basic treatment 4)treatment of risk and provoking factors. and preceeding disease 5)complications and conservative therapy 6)rehabilitation. For a period of basic treatment both herb medication and urokinase therapy were applied at the same time. Intravenous injection has been given at a unit of 300.000 dosage a day as urokinase therapy during basic treatment. If they showed any dubious symptom in glucose tolerance test. fructose 500ml and urokinase 300.000 dosage were mixed and injected. In case of no symptom 5% DW 500ml was mixed with urokinase 300.000 unit. and injected at a speed of 15gtt per minute. 3. Results and Conclusions 1) The level of ambulation has been improved from 42.9% when admitted to 73.2% when discharged in the degree of recovery. The level of severe function disorder has been remarkably decreased from 55.4% when admitted to 19.6% when discharged. 2) The treatment effect on the basis of therapeutic response of clinical and subjective symptom shows as follows: 7.1% Excellent. 35.7% Good. 37.5% Effective. 10.7% Stationary. and 8.9% Aggravated. The total recovery above effective shows 80.3%. Judging from the above results I think it proper to develop the model of better preventing and treating ischemic stroke through effective therapeutic and clinical studies of integrated oriental and western medicine.
The release, sampling and analytical methods have been developed and tested for perfluorocarbons (PFCs) atmospheric tracers in order to gain insight into the atmospheric transport and dispersion over the urban conditions of Seoul, Korea. Although PFCs tracer experiments provide unique opportunities to test local and urban scale of transport and dispersion, no previous experiment with PFCs has been conducted in Korea. PMCH and PDCH were chosen as targeted tracers in our study due to their extreme low ambient concentrations and great sensitivities among various PFCs. For PFCs release system, a set of micro-metering pump, electronic balance, vaporizing furnace and high speed blower was constructed for precise and accurate release of tracers. The precision of released rate by this system was estimated to be 1%. Samplings of PFCs were carried out by fabricated portable air samplers with micro pumps and rotameters into glass tubes packed with 150 mg of Carboxen-569. The uncertainty of these sampling system was maintained below 14%. PMCH and PDCH were quantified in GC/ECD with preconditioned injection system to eliminate the interference compounds using traps and subsequent catalytic conversion system prior to column separation. Three intensive field test were undertaken during the springtime of 2002 to 2004 in eastern part of Seoul. Daily background samples were collected to characterize the background levels of PMCH and PDCH prior to their release. The observed background concentrations of PMCH ranged from 3.5 to 10.1 fL/L and varied randomly in location and time in this study. Its mean and standard variation of background concentration ($6.8{\pm}1.9\;fL/L$) are higher than those ($3.2{\sim}5.8\;fL/L$) of other historic tracer studies. Identified uncertainty for background PMCH was $1.7{\sim}2.0\;fL/L$ using this analytical system. Combined relative uncertainty in determining the tracer's concentrations was estimated as 17%. However, its background concentrations and uncertainty in concentration determination were found to be low and stable enough for tracer study.
실리콘 기판으로 만든 바이오센서에서 펩타이드-항체의 접합 동특성을 회전 타원분광계로 정밀하게 측정하고 분석하였다. 극도로 낮은 몰농도의 펩타이드를 측정할 때, 시료가 놓이는 바이오센서의 표면의 불완전한 편평도와 완충용액 굴절률 변화로 인한 측정오차를 줄이기 위하여 금속박막의 유리 프리즘 대신에 실리콘 기판 위에 덱스트란 SAM을 직접 적층하여 바이오센서를 만들었다. $100{\mu}l/min$의 완충용액 주입속도에서 바이오센서에 올려진 항체 및 펩타이드의 접합특성을 각각 측정하였다. 리터당 5 ng의 낮은 항체농도에서도 항체-덱스트란 SAM 사이의 동특성을 쉽게 측정할 수 있었다. 또한 100 nM까지의 펩타이드에 대한 미세한 흡착 및 해리 특성을 정밀하게 측정할 수 있었으며, 접합 동특성 식에 이 실험결과를 피팅하여 흡착계수와 해리계수를 구할 수 있었다. 이 결과로부터 펩타이드의 평형상태의 해리상수인 $K_D$는 97 nM이었고, 이 수치는 Class I에 속함을 알 수 있었다.
표고버섯(J NM3022) 의 톱밥재배시 적절한 배지크기 및 배지조성을 구명하기 위하여 '05년부터 2년동안 시험결과 다음과 같은 결과를 얻었다. 표고버섯 톱밥재배를 위하여 배지길이와 직경이 다른 12가지 크기의 배지를 이용하여 배양기간, 배양완성률을 시험한 결과 가장 적절한 배지크기는 길이 25 cm ${\times}$ 직경 14cm, 무게 2.5 kg 배지였다. 소나무톱밥의 포화수분함량은 495 $m{\ell}/100g$으로 침 나무동밥 251 $m{\ell}/100g$보다 약 2배 많았다. 참나무톱밥 100% 등 10조합의 배지조성 중 균사생장속도와 균사일도가 가장 좋았던 배지조성은 참나무톱밥 80%+밀기울 20%와 참나무톱밥 80%+미강 20% 처리였으며, 가장 적합한 배지수분함량은 55%였다. 배양기간을 단축하기 위하여 배지중앙에 유공관을 설치하였을 때 무처리에 비하여 길이 20 cm 배지는 11일, 30 cm 배지는 32일을 단축할 수 있었다. 배지표면 갈변화에 가장 좋았던 처리는 $10^{\circ}C$ 정도의 변온과 봉지천공으로 갈변 소요기간은 35일로 동일조건의 무천공처리에 비하여 54일을 단축시킬 수 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.