• Title/Summary/Keyword: Injection methods

Search Result 2,893, Processing Time 0.026 seconds

A Study on the Direction of Research for Pharmacopuncture through the Analysis on the Current Status of Chinese Herbal Injections (중약주사제 실태현황 분석을 통한 국내 약침 연구 방향 모색)

  • Hwang, Ji Hye;Choi, Suhyeon;Song, Ho Sueb
    • Korean Journal of Acupuncture
    • /
    • v.38 no.4
    • /
    • pp.250-266
    • /
    • 2021
  • Objectives : This study was conducted to suggest new alternative methods to improve pharmacopuncture and Korean medicine research by analyzing the injection route, pharmacological effect, and status studies of Chinese herbal injections. Methods : 130 types of marketed and licensed Chinese herbal injection were searched from National Medical Products Administration (NMPA) of China. CNKI, PubMed, EMBASE, and the 2020 edition of the Chinese Pharmacopoeia were used to collect additional information. 'Herbal injection' and 'Chinese herbal injection' were used as keywords. All data were collected mainly on the treatment of Chinese herbal injection. But data which were not related to the relevant research or Chinese herbal injection were excluded. Results : Intramuscular injection accounted for more than half of the single injection route (51%). Acupoint and intramuscular injections accounted for 55% of dual injection routes. Acupoint, intravenous, and intramuscular injections accounted for the largest proportion (76%) of the multiple routes of injections. As for the pharmacological effect, injection for cardiovascular diseases accounted for 29%. About the number of raw herbal materials, single herbal material was the most common. Twelve intervention studies all tested intravenous injections, and half of them investigated cardiocerebrovascular diseases. All were given by intravenous injection. In the side effect section, the most common symptoms were nausea and vomiting. Conclusions : Through the results, it is expected to be used for research and development of new pharmacopuncture and herbal medicine.

Comparative Study on the Effects of Bee Venom Pharmacopuncture According to the Treatment Method for Knee Osteoarthritis

  • Lee, Seung-Hwon;Kwon, Gi-Sun;Kang, Min-Soo;Yoon, Hyun-Min;Kim, Cheol-Hong
    • Journal of Pharmacopuncture
    • /
    • v.15 no.4
    • /
    • pp.7-14
    • /
    • 2012
  • Objectives: The purpose of this study is to compare the effects of bee venom pharmacopuncture (BVP) therapy according to the methods used to treat knee osteoarthritis (OA): intra-acupoint combined with intra-articular injection, intra-acupoint injection, and intra-articular injection. Methods: A total of 69 patients were recruited by the Department of Acupuncture & Moxibustion at Dong-Eui Oriental University Hospital from February 1 to July 23, 2012. The patients were assigned to 3 groups: the first group with intra-acupoint combined with intra-articular BVP Injection (the experimental group), the 2nd group with intra-acupoint BVP injection (control group II), and the 3rd group with intra-articular BVP injection (control group II). The participants were assigned in the order in which they were recruited. Treatments were done twice a week, for a total of 9 times. The effectiveness was assessed by using the visual analouge scale (VAS) and the Korea Western Ontario and McMaster Universities Osteoarthritis Index (KWOMAC). Results: All three groups exhibited significant VAS and KWOMAC effects. Moreover, the 4 week follow-up after the final treatment showed a persistence of BVP effects. However, when the groups were compared, no statistically significant differences in VAS and KWOMAC were noted, but when improvement was considered, the results showed that intra-articular injection was more effective than intra-acupoint injection. Especially, intra-acupoint combined with intra-articular injection was the most effective among the three treatments. Conclusions: Combining intra-acupoint with intra-articular injection, depending on the patient's symptoms, may produce better results when conservatively treating knee OA.

Accuracy of Live Fluoroscopy to Detect Intravascular Injection During Lumbar Transforaminal Epidural Injections

  • Lee, Min-Hye;Yang, Kyung-Seung;Kim, Young-Hoon;Jung, Hyun-Do;Lim, Su-Jin;Moon, Dong-Eon
    • The Korean Journal of Pain
    • /
    • v.23 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • Background: Complications following lumbar transforaminal epidural injection are frequently related to inadvertent vascular injection of corticosteroids. Several methods have been proposed to reduce the risk of vascular injection. The generally accepted technique during epidural steroid injection is intermittent fluoroscopy. In fact, this technique may miss vascular uptake due to rapid washout. Because of the fleeting appearance of vascular contrast patterns, live fluoroscopy is recommended during contrast injection. However, when vascular contrast patterns are overlapped by expected epidural patterns, it is hard to distinguish them even on live fluoroscopy. Methods: During 87 lumbar transforaminal epidural injections, dynamic contrast flows were observed under live fluoroscopy with using digital subtraction enhancement. Two dynamic fluoroscopy fluoroscopic images were saved from each injection. These injections were performed by five physicians with experience independently. Accuracy of live fluoroscopy was determined by comparing the interpretation of the digital subtraction fluoroscopic images. Results: Using digital subtraction guidance with contrast confirmation, the twenty cases of intravascular injection were found (the rate of incidence was 23%). There was no significant difference in incidence of intravascular injections based either on gender or diagnosis. Only five cases of intravascular injections were predicted with either flash or aspiration of blood (sensitivity = 25%). Under live fluoroscopic guidance with contrast confirmation to predict intravascular injection, twelve cases were predicted (sensitivity = 60%). Conclusions: This finding demonstrate that digital subtraction fluoroscopic imaging is superior to blood aspiration or live fluoroscopy in detecting intravascular injections with lumbar transforaminal epidural injection.

A Study on the Injection Molding Process for Manufacturing of Alternator Pulley (얼터네이터 풀리의 제조를 위한 사출성형공정에 관한 연구)

  • 민병현;김영호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.159-165
    • /
    • 2002
  • So far, an alternator pulley has been formed by cold forging and casting with a metal due to the necessity of its high strength. Various advantages such as the light weight, the low cost, and the high productivity can be obtained by the injection molding process using engineering plastics. Engineering plastics have an excellent performance in the characteristics off strength vs. weight, a good forming ability and a productivity. The object of this study is to develop an alternator pulley, which has been made with a metal, using the injection molding process based on Taguchi methods. A sink mark is considered as a characteristic parameter to improve the quality. The FEM Simulation CAE tool, Moldflow, is used for the analysis of injection molding process.

A Study on the Measurement of Individual Spray Cone Angle from Gasoline Direct Injection Injector using Spray Pattern Analysis (분무패턴 분석을 이용한 가솔린 직접 분사식 인젝터의 개별 분무플럼 분무각 측정 방법에 대한 연구)

  • Park, Jeonghyun;Cho, Hanbin;Park, Suhan
    • Journal of ILASS-Korea
    • /
    • v.25 no.2
    • /
    • pp.51-59
    • /
    • 2020
  • The purpose of this study is to propose and compare methods for measuring individual spray cone angles using spray cross-section images. In direct injection gasoline engines, it was believed that the distribution of air-fuel mixture in the combustion chamber directly affected combustion performance and emission formation. However, since gasoline direct injection (GDI) injectors have a small injection angle, interference between individual spray plumes occurs. Therefore, GDI injectors have only measured the spray angle of the entire spray. To overcome these limitations, three methods of indirectly measuring the spray cone angles of individual spray plume were presented and compared by forming sheet beams using Nd:YAG laser and acquiring spray cross-section images. Each method currently has advantages and disadvantages, and research to apply the method suitable for various GDI injectors needs to be continued.

Development of Micro mold with Electroplating Ni for Injection molding (사출 성형을 위한 니켈 도금을 수행한 마이크로 몰드의 개발)

  • Hwang, Kyo-Il;Kim, Hun-Mo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.2 s.179
    • /
    • pp.138-145
    • /
    • 2006
  • An injection molding is necessary to mass-product for micro-nano system, so micro-nano mold must be developed for injection molding. The micro-nano mold has precision and strength to overcome a surround of injection. So in this paper, two methods were used. First, after etching the Al, Ni was electroplated in etched AI. The other, LIGA method was used. A temperature and thickness of Ni are important factors in these methods. So after fabrication, the simulation was processed to find optimal thickenss of Ni and temperature.

Variable-magnitude Voltage Signal Injection for Current Reconstruction in an IPMSM Sensorless Drive with a Single Sensor

  • Im, Jun-Hyuk;Kim, Sang-Il;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1558-1565
    • /
    • 2018
  • Three-phase current is reconstructed from the dc-link current in an AC machine drive with a single current sensor. Switching pattern modification methods, in which the magnitude of the effective voltage vector is secured over its minimum, are investigated to accurately reconstruct the three-phase current. However, the existing methods that modify the switching pattern cause voltage and current distortions that degrade sensorless performance. This paper proposes a variable-magnitude voltage signal injection method based on a high frequency voltage signal injection. The proposed method generates a voltage reference vector that ensures the minimum magnitude of the effective voltage vector by varying the magnitude of the injection signal. This method can realize high quality current reconstruction without switching pattern modification. The proposed method is verified by experiments in a 600W Interior permanent magnet synchronous machine (IPMSM) drive system.

Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method

  • Lee, Suji;Hong, Seoung-Jin;Paek, Janghyun;Pae, Ahran;Kwon, Kung-Rock;Noh, Kwantae
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.1
    • /
    • pp.55-64
    • /
    • 2019
  • PURPOSE. The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS. The maxillary edentulous master cast was fabricated and round shaped four notches were formed. The cast was duplicated to ten casts and scanned. In the injection molding method, designed denture bases were milled from a wax block and fabricated using SR Ivocap injection system. Denture bases were milled from a pre-polymerized block in the milling method. In the RP method, denture bases were printed and post-cured. The intaglio surface of the base was scanned and surface matching software was used to measure inaccuracy. Measurements were performed between four notches and two points in the mid-palatal suture to evaluate inaccuracy. The palatine rugae resolution was evaluated. One-way analysis of variance was used for statistical analysis at ${\alpha}=.05$. RESULTS. No statistically significant differences in distances among four notches (P>.05). The accuracy of the injection molding method was lower than those of the other methods in two points of the mid-palatal suture significantly (P<.05). The degree of palatine rugae resolution was significantly higher in the injection molding method than that in other methods (P<.05). CONCLUSION. The overall accuracy of the denture base is higher in milling and RP method than the injection molding method. The degree of fine reproducibility is higher in the injection molding method than the milling or RP method.

Sensorless Control of IPMSM with a Simplified High-Frequency Square Wave Injection Method

  • Alaei, Ahmadreza;Lee, Dong-Hee;Ahn, Jin-Woo;Saghaeian Nejad, Sayed Morteza
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1515-1527
    • /
    • 2018
  • This paper presents a sensorless speed control of IPMSM (Interior Permanent Magnet Synchronous Motor) using the high-frequency (HF) square wave injection method. In the proposed HF pulsating square wave injection method, injection voltage is applied into the estimated d-axis of rotor and high-frequency induced q-axis current is considered to estimate the rotor position. Conventional square wave injection methods may need complex demodulation process to find rotor position, while in the proposed method, an easy demodulation process based on the rising-falling edge of the injected voltage and carrier induced q-axis current is implemented, which needs less processing time and improves control bandwidth. Unlike some saliency-based sensorless methods, the proposed method uses maximum torque per ampere (MTPA) strategy, instead of zero d-axis command current strategy, to improve control performance. Furthermore, this paper directly uses resultant d-axis current to detect the magnet polarity and eliminates the need to add an extra pulse injection for magnet polarity detection. As experimental results show, the proposed method can quickly find initial rotor position and MTPA strategy helps to improve the control performance. The effectiveness of the proposed method and all theoretical concepts are verified by mathematical equations, simulation, and experimental tests.

Evaluation of Effectiveness of Vacuum Oral Cleaner Developed for Patients with Limited Mobility

  • Lee, Jae-Hyun;Jung, Ki-Won;Kim, Hee-Kyung;Koo, Ki-Tae;Kim, Sung-Hun
    • The Journal of the Korean dental association
    • /
    • v.54 no.12
    • /
    • pp.1035-1044
    • /
    • 2016
  • Purpose : The purpose of this study was to compare the plaque removal effects of vacuum oral cleaner developed for the patients with limited mobility with those of manual toothbrushes and high pressure injection oral cleaner (dental water jet). Meterials and methods : Thirty human subjects were measured with Patient Hygiene Performance index (PHP index) and O'Leary index before and after the use of toothbrush, high pressure injection oral cleaner and vacuum oral cleaner. These three different oral hygiene methods were conducted with seven-day intermittence. Then the statistical analysis was carried out to define plaque removal rate of three different oral hygiene methods (${\alpha}=.05$). Results : According to the efficacy analysis of plaque removal before and after the oral cleaning using each of three methods, significant reduction in plaque after the treatment compared to the previous state when using toothbrush, high pressure injection oral cleaner, and vacuum oral cleaner was observed (P < 0.001). PHP index of tooth brushing was higher than that of the high pressure injection oral cleaner, while PHP index of vacuum oral cleaner did not show significant difference from either of the other two methods. There was no significance difference in O'Leary index among the three methods. Conclusion : Effect of plaque removal using the vacuum oral cleaner is comparable to that of manual tooth brush or high pressure injection oral cleaner, so it will be helpful for self-oral hygiene care of the patients with limited mobility.

  • PDF