• 제목/요약/키워드: Injection methods

검색결과 2,893건 처리시간 0.032초

금속 염 첨가 방법을 이용하여 사출성형된 텅스텐 중합금의 소결거동 (Sintering Behavior of the Injection Molded W-Ni-Fe Heavy Alloy by Addition of Metallic Stat)

  • 김대건;류성수;김은표;이정근;김영도;문인형
    • 한국분말재료학회지
    • /
    • 제6권4호
    • /
    • pp.294-300
    • /
    • 1999
  • This study was carried out to investigate the possibility whether Metal Injection Molding (MIM) process could be applied to 95wt.%W-3.5wt.%Ni-1.5wt.%Fe heavy alloy in order to obtain an intricate shape. Methylcellulose was used in the injection molding for binder. $FeCl_2-4H_2O$ was added in solvent substituting Fe powder and $FeCl_2$ was doped on W-Ni premixed powder. When $FeCl_2-4H_2O$ was added in solvent, the binder separation occurred for injection molding so that the matrix content was changed. Such problem was solved when $FeCl_2$ was doped. In this study. the debinding process did not affect residual carbon content. The sintered microsouctures as addition methods of Fe element and the sintering temperature from $1420^{\circ}C$ to $1470^{\circ}C$, which are around the temperature of liquid phase formation, were observed.

  • PDF

Pyrocatechol Violet Modified Graphite Pencil Electrode for Flow Injection Amperometric Determination of Sulfide

  • Emir, Gamze;Karakaya, Serkan;Dilgin, Yusuf
    • Journal of Electrochemical Science and Technology
    • /
    • 제11권3호
    • /
    • pp.248-256
    • /
    • 2020
  • In this study, pyrocatechol violet (Pcv) is proposed for the first time as an efficient electrocatalyst for oxidation of sulfide and flow injection analysis (FIA) of sulfide. A graphite pencil electrode (GPE) was modified with Pcv via immersion of the GPE into 0.01 M Pcv solution for 15 min. Cyclic voltammograms (CVs) demonstrated that Pcv/GPE exhibits a good electrocatalytic performance due to shift in the potential from +400 at bare GPE to +70 mV at Pcv/GPE and obtaining an enhancement in the peak current compared with the bare GPE. A linear range between 0.25 and 250 μM sulfide with a detection limit of 0.07 μM was obtained from the recorded current-time curves in Flow Injection Analysis (FIA) of sulfide. Sulfide in water samples was also successfully determined using the proposed FI amperometric methods.

만성 어깨통증을 위한 신경차단과 방아쇠점 주사 (Neural Blockade and Trigger Point Injection for Chronic Shoulder Pain)

  • 신근만
    • Clinics in Shoulder and Elbow
    • /
    • 제6권2호
    • /
    • pp.108-114
    • /
    • 2003
  • The shoulder is a complex area which makes it vulnerable to painful pathologic processes. Chronic shoulder pain has become more common recently due to increased use of computers and a ,generally more sedentary life style among most people . Trigger point injection and neural blockade are useful for the management of chronic shoulder pain which has not improved with conservative treatment. Published articles concerning trigger point injection or neural blockade for chronic shoulder pain were reviewed to evaluate promising methods. If we are careful to remain aware of the details and complications in addition to adhering to effective treatments, these should be good armamentarium for doctors enthusiastic about the management of chronic shoulder pain.

Numerical modeling of thrombolysis - Effects of nozzle types and ejection velocities

  • Jeong, Woo-Won;Rhee, Kye-Han
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권2호
    • /
    • pp.13-18
    • /
    • 2006
  • Direct injection of a fibrinolytic agent to the intra-arterial thrombosis may increase the effectiveness of thrombolysis by enhancing the permeation of thrombolytic agents into the blood clot. Permeation of fibrinolytic agents into a clot is influenced by the surface pressure, which is determined by the injection velocity of fibrinolytic agents. Computational fluid dynamic methods were used in order to predict clot lysis for different jet velocities and nozzle arrangements. Firstly, thrombolysis of a clot was mathematically modeled based on the pressure and lysis front velocity relationship. Direct injection of a thrombolytic agent increased the speed of thrombolysis significantly and the effectiveness was increased as the ejecting velocity increased. The nine nozzles model showed about 20% increase of the lysed volume, and the one and seventeen nozzles models did not show significant differences. Secondly, thrombolysis was modeled based on the enzyme transport and the fluid flow equations, and quasi steady numerical analysis was performed. Clot lysis efficiency was also increased as injection velocity increased.

  • PDF

사출성형을 이용한 마이크로 채널의 패키징 공정에 관한 연구 (A Study on a In-mold Packaging Process using Injection Molding)

  • 이관희;박덕수;윤재성;유영은;최두선;김선경
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1821-1824
    • /
    • 2008
  • A novel in-mold packaging process has been developed to manufacture devices with closed channels. In this unified process, fabrication of open channels and forming the rigid cover on top of them are sequentially integrated in the same mold. The entire process is comprised of two phases. In the first phase, the open channels are fabricated under an exquisitely controlled temperature and pressure using the conventional micro injection molding technology. In the second phase, the closed channels are fabricated by conducting the injection molding process using the molded structure with the open channels as a mold insert. As a result, the in-mold technology can eliminate the bonding processes such as heating, ultrasonic or chemical processes for cohesion between the channel and the cover, which have been required in conventional methods.

  • PDF

Ductal Carcinoma in situ with Multicystic Changes in a Patient with Interstitial Mammoplasty via Paraffin Injection: MRI and Pathological Findings

  • Park, Jiyoon;Woo, Ok Hee;Kim, Chungyeul;Cho, Kyu Ran;Seo, Bo Kyoung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권2호
    • /
    • pp.127-130
    • /
    • 2015
  • Direct injection of foreign material, such as liquid paraffin and silicone, into the breast can induce a foreign body granulomatous reaction and fibrosis, resulting in hard, nodular breast masses and architectural distortion that can mimic neoplasm. Conventional methods, including physical examination, mammography, and ultrasonography are of little use to differentiate between foreign body-induced mastopathy and breast cancer. In patients with foreign body injection such as breast augmentation, dynamic contrast enhanced MR imaging is an excellent imaging modality. Here, the authors report the MR imaging and pathological findings of ductal carcinoma in situ (DCIS) with multicystic changes in a 41-year-old woman with a previous history of interstitial mammoplasty by paraffin injection.

All-optical Flip-flop based on Optical Beating and Bistability in an Injection-locked Fabry-Perot Laser Diode

  • Kim, Junsu;Lee, Hyuek Jae;Park, Chang-Soo
    • Journal of the Optical Society of Korea
    • /
    • 제20권6호
    • /
    • pp.698-703
    • /
    • 2016
  • We report a new all-optical flip-flop (AOFF) with a quite simple structure, using optical beating in an injection-locked Fabry-Perot laser diode (FP-LD) with optical bistability. While conventional AOFF methods using an injection-locked FP-LD require additional devices such as secondary FP-LDs or polarization controllers for reset operation, the proposed method can be implemented using only a single commercially available FP-LD with set and reset signals. The optical beating induces intensity fluctuations inside the FP-LD, and releases the locking state to the reset state. Even though we demonstrated the AOFF at 100 Mbit/s, we expect that its operation rate could extend to 10 Gbit/s, according to the limit of the FP-LD's frequency response.

지하 콘크리트 구조물에 적용되는 에폭시 수지계 주입형 누수보수재료의 화학저항성능 평가 (Evaluation of Chemical Resistance of Epoxy Resin Injection Type Leakage Repairing Materials Applied to Underground Concrete Structures)

  • 박소영;김수연;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.41-42
    • /
    • 2017
  • In this study, an investigation was made to study the chemical resistance performance of epoxy resin injection type leakage repair material used in the Korean construction market in accordance to the test method outlined in "ISO TS 16774, Part 2; Test Method for Chemical Resistance." This is a new standard document used for quality control method of injection type repair material used for leakage cracking of underground concrete structures. The results of this study can be expected to be utilized as reference data that can be used for quality improvement of the maintenance methods for future construction.

  • PDF

금형온도와 탈지조건이 사출성형에 의한 알루미나 부품 제조에 미치는 영향 (EFfect of Molding Temperature and Debinding Conditions on Fabrication of Alumina Component by Injection Molding)

  • 임형택;임대순
    • 한국세라믹학회지
    • /
    • 제32권5호
    • /
    • pp.559-566
    • /
    • 1995
  • Alumina powder was coated with stearic acid and then mixed with isotactic polypropylene, atactic polypropylene as binders at 15$0^{\circ}C$ for 2 hours. The mixture was then injection molded at various mold temperatures using injection molding machine to investigate the effect of the molding temperature and debinding parameters on the formation of the defects. The molded specimens were debinded in both air and nitrogen atmospheres. Wicking and solvent methods were also used to enhance debinding efficiency. The specimens were prefired at 120$0^{\circ}C$ and then sintered at 150$0^{\circ}C$ for 3 hours. Various defects were formed at mold temoperature of 3$0^{\circ}C$, 6$0^{\circ}C$ and 10$0^{\circ}C$ and any noticeable defect was not formed at 85$^{\circ}C$. The density of green body increased with mold temperature. Debinding in air atmosphere was more effective than in nitrogen atmosphere. Results also proved that wicking and solvent treatments helped minimize the number of defects.

  • PDF

복잡한 3차원 곡면을 가지는 플라스틱 사출 성형품을 위한 진원도의 수학적 모델링 (Mathematical Modeling of the Roundness for Plastic Injection Mold Parts with Complicated 3D curvatures)

  • 윤선진
    • Design & Manufacturing
    • /
    • 제13권2호
    • /
    • pp.6-11
    • /
    • 2019
  • In this study, we constructed the mathematical model to evaluate the roundness for plastic injection mold parts with complicated 3D curvatures. Mathematically we started off from the equation of circle and successfully derived an analytical solution so as to minimize the area of the residuals. On the other hand, we employed the numerical method the similar optimization process for the comparison. To verify the mathematical models, we manufactured and used a ball valve type plastic parts to apply the derived model. The plastic parts was fabricated under the process conditions of 220-ton injection mold machine with a raw material of polyester. we experimentally measured (x, y) position using 3D contact automated system and applied two mathematical methods to evaluated the accuracy of the mathematical models. We found that the analytical solution gives better accuracy of 0.4036 compared to 0.4872 of the numerical solution. The numerical method however may give adaptiveness and versatility for optional simulations such as a fixed center.