• Title/Summary/Keyword: Injection distance

Search Result 316, Processing Time 0.026 seconds

A study on the strategies to lower technologist occupational exposure according to the performance form in PET scan procedure (PET 검사실 종사자의 업무 행위 별 방사선피폭 조사에 따른 피폭선량 저감화를 위한 연구)

  • Ko, Hyun Soo;Kim, Ho Sung;Nam-Kung, Chang Kyeoung;Yoon, Soon Sang;Song, Jae Hyuk;Ryu, Jae Kwang;Jung, Woo Young;Chang, Jung Chan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.17-29
    • /
    • 2015
  • Purpose For nuclear medicine technologists, it is difficult to stay away from or to separate from radiation sources comparing with workers who are using radiation generating devices. Nuclear medicine technologists work is recognized as an optimized way when they are familiar with work practices. The aims of this study are to measure radiation exposure of technologists working in PET and to evaluate the occupational radiation dose after implementation of strategies to lower exposure. Materials and Methods We divided into four working types by QC for PET, injection, scan and etc. in PET scan procedure. In QC of PET, we compared the radiation exposure controlling next to $^{68}Ge$ cylinder phantom directly to controlling the table in console room remotely. In injection, we compared the radiation exposure guiding patient in waiting room before injection to after injection. In scan procedure of PET, we compared the radiation exposure moving the table using the control button located next to the patient to moving the table using the control button located in the far distance. PERSONAL ELECTRONIC DOSEMETER (PED), Tracerco$^{TM}$ was used for measuring exposed radiation doses. Results The average doses of exposed radiation were $0.27{\pm}0.04{\mu}Sv$ when controlling the table directly and $0.13{\pm}0.14{\mu}Sv$ when controlling the table remotely while performing QC. The average doses of exposed radiation were $0.97{\pm}0.36{\mu}Sv$ when guiding patient after injection and $0.62{\pm}0.17{\mu}Sv$ when guiding patient before injection. The average doses of exposed radiation were $1.33{\pm}0.54{\mu}Sv$ when using the control button located next to the patient and $0.94{\pm}0.50{\mu}Sv$ when using the control button located in far distance while acquiring image. As a result, there were statistically significant differences(P<0.05). Conclusion: From this study, we found that how much radiation doses technologists are exposed on average at each step of PET procedure while working in PET center and how we can reduce the occupational radiation dose after implementation of strategies to lower exposure. And if we make effort to seek any other methods to reduce technologist occupational radiation, we can minimize and optimize exposed radiation doses in department of nuclear medicine. Conclusion From this study, we found that how much radiation doses technologists are exposed on average at each step of PET procedure while working in PET center and how we can reduce the occupational radiation dose after implementation of strategies to lower exposure. And if we make effort to seek any other methods to reduce technologist occupational radiation, we can minimize and optimize exposed radiation doses in department of nuclear medicine.

  • PDF

Impaired Voluntary Wheel Running Behavior in the Unilateral 6-Hydroxydopamine Rat Model of Parkinson's Disease

  • Pan, Qi;Zhang, Wangming;Wang, Jinyan;Luo, Fei;Chang, Jingyu;Xu, Ruxiang
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.2
    • /
    • pp.82-87
    • /
    • 2015
  • Objective : The aim of this study was to investigate voluntary wheel running behavior in the unilateral 6-hydroxydopamine (6-OHDA) rat model. Methods : Male Sprague-Dawley rats were assigned to 2 groups : 6-OHDA group (n=17) and control group (n=8). The unilateral 6-OHDA rat model was induced by injection of 6-OHDA into unilateral medial forebrain bundle using a stereotaxic instrument. Voluntary wheel running activity was assessed per day in successfully lesioned rats (n=10) and control rats. Each behavioral test lasted an hour. The following parameters were investigated during behavioral tests : the number of running bouts, the distance moved in the wheel, average peak speed in running bouts and average duration from the running start to the peak speed. Results : The number of running bouts and the distance moved in the wheel were significantly decreased in successfully lesioned rats compared with control rats. In addition, average peak speed in running bouts was decreased, and average duration from the running start to the peak speed was increased in lesioned animals, which might indicate motor deficits in these rats. These behavioral changes were still observed 42 days after lesion. Conclusion : Voluntary wheel running behavior is impaired in the unilateral 6-OHDA rat model and may represent a useful tool to quantify motor deficits in this model.

Improvement of bearing capacity of footing on soft clay grouted with lime-silica fume mix

  • Fattah, Mohammed Y.;Al-Saidi, A'amal A.;Jaber, Maher M.
    • Geomechanics and Engineering
    • /
    • v.8 no.1
    • /
    • pp.113-132
    • /
    • 2015
  • In this study, lime (L), silica fume (SF), and lime-silica fume (L-SF) mix have been used for stabilizing and considering their effects on the soft clay soil. The improvement technique adopted in this study includes improving the behaviour, of a square footing over soft clay through grouting the clay with a slurry of lime-silica fume before and after installation of the footing. A grey-colored densified silica fume is used. Three percentages are used for lime (2%, 4% and 6%) and three percentages are used for silica fume (2.5%, 5%, 10%) and the optimum percentage of silica fume is mixed with the percentages of lime. Several tests are made to investigate the soil behaviour after adding the limeand silica fume. For grouting the soft clay underneath and around the footing, a 60 ml needle was used as a liquid tank of the lime-silica fume mix. Slurried silica fume typically contains 40 to 60% silica fume by mass. Four categories were studied to stabilize soft clay before and after footing construction and for each category, the effectiveness of grouting was investigated; the effect of injection hole spacing and depth of grout was investigated too. It was found that when the soft clay underneath or around a footing is injected by a slurry of lime-silica fume, an increase in the bearing capacity in the range of (6.58-88)% is obtained. The footing bearing capacity increases with increase of depth of grouting holes around the footing area due to increase in L-SF grout. The grouting near the footing to a distance of 0.5 B is more effective than grouting at a distance of 1.0 B due to shape of shear failure of soft clay around the footing.

Estimation of Stellate Ganglion Block Injection Point Using the Cricoid Cartilage as Landmark Through X-ray Review

  • Park, Jeong-Soo;Kim, Ki-Jun;Lee, Youn-Woo;Yoon, Duck-Mi;Yoon, Kyung-Bong;Han, Min-Young;Choi, Jong-Bum
    • The Korean Journal of Pain
    • /
    • v.24 no.3
    • /
    • pp.141-145
    • /
    • 2011
  • Background: Stellate ganglion block is usually performed at the transverse process of C6, because the vertebral artery is located anterior to the transverse process of C7. The purpose of this study is to estimate the location of the transverse process of C6 using the cricoid cartilage in the performance of stellate ganglion block. Methods: We reviewed cervical lateral neutral-flexion-extension views of 48 patients who visited our pain clinic between January and June of 2010. We drew a horizontal line at the surface of the cricoid cartilage in the neutral and extension views of cervical lateral x-rays. We then measured the change in the shortest distance from this horizontal line to the lowest point of the transverse process of C6 between the neutral and extension views. Results: There was a statistically significant difference in the shortest distance from the horizontal line at the surface of the cricoid cartilage to the lowest point of transverse process of C6 between neutral position and neck extension position in both males and females, and between males and females in both neutral position and neck extension position. The cricoid cartilage level was 4.8 mm lower in males and 14.4 mm higher in females than the lowest point of transverse process of C6 in neck extension position. Conclusions: Practitioners should recognize that the cricoid cartilage has cephalad movement in neck extension. In this way, the cricoid cartilage can be still useful as a landmark for stellate ganglion block.

A study on Behavior of Turbulent Transient Jets with Butane and Propane (Butane 및 propane의 비정상 난류 제트 특성에 관한 연구)

  • Lee, Beom-Ho;Song, Hak-Hyun;Cho, Seung-Hwan;Hong, Sung-Tae;Lee, Dae-Yup;Lee, Tae-Woo
    • Journal of ILASS-Korea
    • /
    • v.15 no.2
    • /
    • pp.74-82
    • /
    • 2010
  • In order to understand the behavior of transient gaseous injection used in an LPG (Liquefied Petroleum Gas) engine, turbulent incompressible transient jets with butane and propane were measured and analyzed at pressures of 1.5 bar and 2.0 bar with injector diameters of 3 mm and 5 mm. Mie-scattering method with a tracer was used, and images were processed to investigate the behavior of butane and propane jets. Distances from the nozzle to transition region were measured as $L_e/d_{inj}$=4.35~19.4, where $L_e$ and $d_{inj}$ indicate respectively a distance from nozzle to transition point and nozzle diameter. Slits and tubes around jet at near-field were introduced to measure the effect of entrainment and the diameter of jet, which revealed that the entrainment of surrounding air is significant for developing jet diameter. When the entrainment is restricted, the behavior of jet became deviating from the baseline. It was found that the virtual origin located outside of a nozzle towards jet tip within the conditions of this work, and its location was estimated as $x_o/d_{inj}$=0.56~7.25, where $x_o$ is a distance from nozzle to virtual origin.

Numerical Investigation of Factors affecting Photoresist Stripping Process on the ITO Surface using the Spray Method (노즐 분사 방식의 ITO 표면 포토레지스트 박리과정 요인의 수치해석)

  • Kim, Joon Hyun;Lee, Joon Hyuck;Kang, Tae Seong;Joo, Gi-Tae;Kim, Young Sung;Jeong, Byung Hyun;Lee, Dae Won
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.2
    • /
    • pp.158-165
    • /
    • 2017
  • This study investigated spraying factors applicable to stripper usage. Cyclodextrine, as environment-friendly material, was included in the stripper composition. An efficient spray technology was applied for the Photoresist strip. For industrial applications, stripping requires a temperature below $50^{\circ}C$, a strip time within 50 s, and chemically stable activation. Spraying factors were organized considering many conditions-orifice diameter, working pressure (inlet speed), spray distance, and spray angle. For commercial practicability, the flow rate was limited to 3 L/min. The nozzle parameters were nozzle orifice diameter of 1.8-2.2 mm, spray distance of 40-60 mm, and injection speed of 0.7-1.2 m/s. Through the thermal spray movement of the fluid, the thermal boundary layer for a chemical reaction just above the ITO-glass surface and momentum region for sufficient agitation (above 4 m/s) was achieved.

Design and Implementation of Portable Electrostatic Meter Applicable to Industrial Site (산업 현장에 적용할 수 있는 휴대형 정전기 측정기 설계 및 구현)

  • Jang, Mun-Seok;Lee, Eung-Hyuk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.971-977
    • /
    • 2020
  • In this paper, We propose a portable electrostatic meter which can measure high voltage static electricity caused by friction to prevent fire or explosion accidents in grinding, crushing, power injection, transport, filling, dust removal, painting, and foreign matter removal processes. The proposed device not only shows static electricity strength in 4 steps with respect to distance and voltage but also gives warning with a buzzer, on process facilities that are likely to generate high voltage static electricity due to friction. The device is implemented by filtering the signal detected by the wireless antenna, amplifying the signal by 6 times, and passing the signal through the integrator circuit. Tests are carried out with an electrostatic discharge simulator. And the results show that 4 LEDs are turned on at the distance of 10cm, 3 LEDs at 12cm, 2 LEDs at 13cm, and 1 LED at 15cm, when a fixed voltage of 500V is given. And also, the tests show that the static electricity can be detected at 5cm on 100V, 10cm on 200V, 15cm on 500V, 20cm on 1000V, and 25cm on 1500V. We expect to reduce accidents caused by static electricity by allowing safety managers on fields where fire or explosion accidents can happen to monitor static electricity.

The efficacy and efficiency of percutaneous lidocaine injection for minimizing the carotid reflex in carotid artery stenting: A single-center retrospective study

  • Hyung Kyu Lee;Tae Joon Park;Sang Pyung Lee;Jin Wook Baek;Seong Hwan Kim;Aiden Ryou
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.26 no.2
    • /
    • pp.130-140
    • /
    • 2024
  • Objective: To assess whether local anesthetic infiltration could minimize the carotid baroreceptor reflex (CBR) which has an incidence after carotid artery stenting (CAS) that varies from 29% to 51%. Methods: This retrospective single-center study included 51 patients (mean age, 70.47 years) who underwent CAS for carotid stenosis. The groups included patients who underwent CAS for asymptomatic ischemic stroke (n=41) or symptomatic disease (n=10). Preprocedural percutaneous lidocaine injections (PPLIs) were administered to 70.6% and 5.9% of patients who underwent elective CAS and emergency CAS, respectively. Results: Among patients who received PPLIs, the mean degree of stenosis was 80.5% (95% confidence interval [CI]: ±10.74, 51-98%). The mean distance from the common carotid artery bifurcation to the most stenotic lesion (CSD) was 8.3 mm (95% CI: ±0.97, 6.3-10.2 mm); the mean angle between the internal carotid artery and common carotid artery (CCA) trunk (IAG) was 65.6° (95% CI: ±2.39, 61-70°). Among patients who did not receive PPLIs, the mean degree of stenosis was 84.0% (95% CI: ±8.96, 70-99%). The mean CSD was 5.9 mm (95% CI: ±1.83, 1.9-9.9 mm); the mean IAG was 60.4° (95% CI: ±4.41, 51-70°). The procedure time was longer in the PPLI group than in the no PPLI group (28.19 [n=39] vs. 18.88 [n=12] days) (P=0.057); the length of intensive care unit stay was shorter in the PPLI group (20.01 [n=36] vs. 28.10 [n=5] days) (P=0.132). Conclusions: Targeted PPLI administration to the carotid bulb decreased aberrant heart rates and blood pressure changes induced by carotid stent deployment and balloon inflation. As CBR sensitivity increases with decreasing distance to the stenotic lesion from the CCA bifurcation, PPLIs may help stabilize patients during procedures for stenotic lesions closer to the CCA.

Anatomical Measurement of the Masseter Muscle and Surface Mapping of the Maximal Thickness Point Using Computed Tomography Analysis (전산화단층촬영 영상분석을 이용한 교근의 해부학적 계측 및 최대 두께점 피부 표지화)

  • Suh, Hyeun-Woo;Kim, Hyo-Seong;Ha, Ki-Young;Kim, Boo-Yeong;Pae, Nam-Seok;Kim, Tae-Yeon
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.173-181
    • /
    • 2011
  • Purpose: Masseter muscle is an important muscle of mastication. Because it has a great influence on the shape of low facial contour, patients who have masseteric hypertrophy show square-shaped jaw appearance. As aesthetic procedures for the reduction of the masseter muscle volume, radiofrequency ablation or botulinum toxin injection is at the center of attention. Authors studied the anatomical measurement of the thickness and width of masseter muscle and the surface mapping of the maximal thickness point using computed tomography (CT) scan to identify the useful guide for the injection of botulinum toxin in masseteric hypertrophy patients. Methods: We analyzed 2 mm-thickness OMU (ostiomeatal unit) CT of 112 normal people (224 masseter muscles) taken from June 2009 to May 2010. First, we measured the thickness, width and depth of the masseter muscle from the skin surface and analysed each by side, sex and age, respectively. The distribution of the thickness of the muscle and the correlation of thickness and width of the muscle were studied also. Second, we underwent surface mapping of the maximal thickness point using CT analysis by means of checking the vertical and horizontal distance from the angle of the mandible. Results: The average thickness and width of the masseter muscle was 17.73 mm and 40.78 mm in the male patients and were 14.33 mm and 37.42 mm in the female patients. Statistically, both figures of the male patients were larger than those of the female patients. However, the depth of the muscle from the skin surface in female patients (7.37 mm) was larger than that of the male patients (6.15 mm). There were no statistical difference in side or age. The width and thickness of the masseter muscle were in the positive correlation. The location of maximal thickness point of the masseter muscle was 27.77 mm vertically and 27.68 mm horizontally in the male patients, and 25.19 mm vertically and 25.42 mm horizontally in the female patients from the angle of mandible. Conclusion: We were able to present statistical evidence of the diagnosis and treatment of the masseteric hypertrophy regarding the anatomical measurements such as the thickness and width. And the maximal thickness point of the masseter muscle may be a useful guide for the clinical procedures of botulinum toxin injection.

Time-dependent characteristics of viscous fluid for rock grouting (암반 그라우팅을 위한 점성유체의 시간의존 특성 분석)

  • Lee, Jong-Won;Kim, Ji-Yeong;Weon, Jo-Hyun;Oh, Tae-Min
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.465-481
    • /
    • 2022
  • Rock grouting is important to improve the waterproof efficiency and mechanical strength of rock medium with joint for utilizing the underground rock space such as tunnel. The grouting materials typically has been used the cement materials, which represent Bingham fluid model. This model can express the relationship of viscosity and yield strength. In addition, it is dependent with elapsed time. The grouting injection performance can be deteriorated with an increase of viscosity and yield strength in the grouting process if the time dependence is ignored. Therefore, in this study, the characteristics of viscosity and yield strength were investigated according to water-cement ratio and time dependence in the laboratory test. Numerical simulation was carried out to investigate the grouting performance according to the time dependence of characteristics in terms of the viscosity model. Given the results, the grouting injected distance and cumulative grout volume were significantly decreased when the time dependence of grouting material was considered. This study, considering the characteristics according to the time dependence of viscosity and yield strength, will be meaningful to the design of grouting injection in field applications.