• Title/Summary/Keyword: Injection Unit

Search Result 362, Processing Time 0.03 seconds

Rupture of Achilles Tendon after Steroid Injection in Achilles Tendinitis (A Report of Five Cases) (아킬레스 건염에서 스테로이드 주입 후 아킬레스 건 파열 (5예 보고))

  • Kim, Jeon-Gyo;Gwak, Heui-Chul;Baik, Jong-Min
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.4
    • /
    • pp.309-315
    • /
    • 2013
  • Purpose: The purpose of the study was to investigate five cases with chronic Achilles tendon rupture that occurred after steroid injections. Materials and Methods: In our hospital, we experienced five cases of chronic Achilles tendon rupture from September 2010 to March 2012. All patients had got steroid injection for Achilles tendinitis at the other hospitals, and their heel pain was aggravated when they visited our outpatient department. After treatment, signs and symptoms of Achilles tendon rupture were developed and the diagnosis was confirmed by ultrasonography or magnetic resonance imaging (MRI). Surgical treatment was done for Achilles tendon rupture. Results: There was difference between intra-operative findings of Achilles tendon rupture and usual chronic Achilles tendon rupture. Unlike usual findings of chronic Achilles tendon rupture whose scar tissue or tissue attenuation are found around the defect area of Achilles tendon, there were partial necrosis of tendon severe adhesion with surrounding tissue, extensive defect and longitudinal rupture on ruptured area. Also, severe inflammation of paratenon, granulation and fibrinoid deposit were found on biopsy findings in four cases. Conclusion: Based on review of data about relative risk and benefit of local corticosteroid injection to inflammatory lesion in Achilles tendon, it requires more attention to Achilles tendon rupture following local corticosteroid injection.

Botulinum Toxin type A injection Versus Lidocaine Injection for Myofascial Pain Involving upper Trapezius (승모근 근막동통에 대한 보툴리눔 독소와 리도카인 주사의 치료효과 비교)

  • Ahn, Sung-Woo;Park, Eun-Hee;Kim, Mee-Eun
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.345-351
    • /
    • 2005
  • The purpose of this double-blind study was to evaluate clinical effects of botulinum toxin type A (BTX-A) injection on myofascial pain syndrome (MPS) involving upper trapezius and compare with those of lidocaine injection. 21 patients presenting with active TrP1 and/or TrP2 in the upper trapezius over 6 months were selected for this study. The subjects were randomly divided into two groups; one group injected with BTX-A (15 unit of $Botox^{(R)}$ / 0.3 ml per trigger point (TrP)) and the other group injected with 0.5% lidocaine (0.3 ml /TrP). The clinical effects were evaluated by VAS and PPT at baseline, 2, 4, 6 and 8 weeks after treatment. BTX-A group showed persistent decrease of VAS values and increase of PPT values following treatment. While there was no significant difference in VAS values between BTX-A and lidocaine groups (p=0.347), there was significant difference in PPT values after treatment between two groups (p=0.000). The subjects received BTX-A showed noticeable improvement in PPT values after treatment, suggesting more reliable effect of BTX-A injection compared with lidocaine injection. The results of this study support that the direct injection of BTX-A to a TrP is an effective and safe treatment for MPS involving upper trapezius.

Numerical Study of slot injection into turbulent supersonic flow on adaptive meshes (적응 격자계를 이용한 초음속 난류유동장의 측면제트분사에 대한 수치적연구)

  • Kim J. R.;Kim I. T.;Kim J. S.
    • Journal of computational fluids engineering
    • /
    • v.6 no.2
    • /
    • pp.40-46
    • /
    • 2001
  • Two-dimensional steady flowfields generated by slot injection into supersonic flow are numerically simulated by the integration of Navier-stokes equation with two-equation κ-turbulence model. High-order upwind scheme is used on unstructured adaptive meshes. The numerical results are compared with experimental data in terms of surface static pressure distributions, the length of the upstream separation region, and the height of the Mach surface for steady flowfields with a Mach number of 3.71 and a unit Reynolds number of 5.83×10/sup 6//m.

  • PDF

A Study on the Air Cushion Pad of Non-contact Glass Transportation Unit (비접촉식 유리 평판 이송 장치 공기 패드 형상에 대한 연구)

  • Jeon, Hyeon-Ju;Kim, Gwang-Seon;Im, Ik-Tae
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.10a
    • /
    • pp.138-144
    • /
    • 2006
  • Non-contact transportation of a large-sized glass plate using air cushion for the sputtering system of liquid crystal display panel was considered. The gas is injected through multiple small holes to maintain the force for levitating glass plate. Complex flow field and resulting pressure distribution on the glass surface was numerically studied to design the air injection pad. The exhaust hole size was varied to obtain evenly distributed pressure distribution at fixed diameter of the injection hole. Considering the force for levitating glass plate, the diameter of the exhaust hole of 30 to 40 times of the gas injection hole was recommended.

  • PDF

The Mold Close and Open Control of Injection Molding Machine Using Fuzzy Algorithm

  • Park, Jin-Hyun;Lee, Young-Kwan;Kim, Hun-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.575-579
    • /
    • 2005
  • In this paper, the development of an IMM(Injection Molding Machine) controller is discussed. Presently, the Mold Close and Open Control Method of a toggle-type IMM is open-loop control. Through the development, a PC based control system was built instead of an existing controller and a closed-loop control replaced the previous control method by using PC based PLC. To control the nonlinear system of toggle type clamping unit, a fuzzy PI control algorithm was selected and it was programmed by an IL(Instruction List) and a LD(Ladder Diagram) on a PC based PLC. The application of fuzzy algorithm as the control method was also considered to change a control object like a mold replacement or an additional apparatus. For the development of an IMM controller, PC based PLC of PCI card type, distributed I/O modules with CANopen and Industrial PC and HMI (Human Machine Interface) software were used.

  • PDF

Development of Electronic Control Fuel Injection and Spark Timing Controller for Automobile Engine (자동차 기관용 전자제어 연료분사 및 점화시기 제어기 개발)

  • Kim, T.H.;Min, G.S.;Yang, S.H.;Jang, H.S.
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.22-35
    • /
    • 1995
  • In this paper, an electronic control unit is developed using 16bit microcomputer for automobile engine. This system incorporate AFS(Air Flow Sensor) of Hot Wire type, DIS(Direct Ignition System), ISC(Idle Speed Control) system, CAS(Cranke Angle Sensor) and other peripheral device. This system includes hardware and software to facilitate precision control of both fuel injection and ignition timing. Especially, this controller consists of position signal(180 teeth) and 4 REF signals. Present system has maximum $720^{\circ}CA$ delay. But this system has maximum $180^{\circ}CA$. Thus, this system is able to precision control both fuel injection and ignition timing.

  • PDF

Wide Speed Direct Torque and Flux Controlled IPM Synchronous Motor Drive Using a Combined Adaptive Sliding Mode Observer and HF Signal Injection

  • Foo, Gilbert;Rahman, M.F.
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.582-592
    • /
    • 2009
  • This paper proposes a new speed sensorless direct torque and flux controlled interior permanent magnet synchronous motor (IPMSM) drive. Closed-loop control of both the torque and stator flux linkage are achieved by using two proportional-integral (PI) controllers. The reference voltage vectors are generated by a SVM unit. The drive uses an adaptive sliding mode observer for joint stator flux and rotor speed estimation. Global asymptotic stability of the observer is achieved via Lyapunov analysis. At low speeds, the observer is combined with the high frequency signal injection technique for stable operation down to standstill. Hence, the sensorless drive is capable of exhibiting high dynamic and steady-state performances over a wide speed range. The operating range of the direct torque and flux controlled (DTFC) drive is extended into the high speed region by incorporating field weakening. Experimental results confirm the effectiveness of the proposed method.

Performance Evaluation of Flow Injection Type Biosensor According to Operating Variables of Pump (펌프의 작동요인에 따른 흐름주입식 바이오센서의 성능 검증)

  • Song D. B.;Jung H. S.;Lee S. K.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.5 s.112
    • /
    • pp.312-317
    • /
    • 2005
  • A flow injection type biosensor was tested to confirm the performance of a batch and a continuous type flow injection unit. Reproducibility and consistence of the biosensor were investigated to determine the effect of pulsations and air bubbles, and the applicability of on-line monitoring. The air bubbles affected the performance of the sensor irrespective of the location, and also the pulsations of the pump influenced the performance of the sensor. The applicability of on-line motoring was accepted as the result of the repeated and long-term measurements.

Development of Ftheta Lens for Laser Scanning Unit (Laser Scanning Unit용 FΘ 렌즈 개발)

  • Jeong, In-Sook;Ban, Min-Sung;Son, Kwang-Eun;Lee, Byoung-Bag
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.13-19
    • /
    • 2013
  • Ftheta Lens, whose image height is proportional to its field view angle, is one of the most important parts in Laser Scanning Unit(LSU). In this paper $f{\theta}$ lens design, mold production and modification method of lens design and mold are introduced. Lens design was carried out with Zemax and Special Toric surfaces were applied for lens surfaces to minimize distortion both in main and sub scanning directions. And a high precision machine with 1nm resolution was used to fabricate lens mold cores. After injection the lens was evaluated and the difference from design was examined. This difference was compensated by modifying lens design and new lens mold cores were made according to modified lens design to obtain the quality of original design.

The Effects of Simultaneous Hand Washing by Nurse and Child Before IV Injection (아동과 간호사의 손씻기 프로그램이 정맥주사와 관련한 아동의 불안, 동통과 피부손상에 미치는 효과)

  • Lee, Ae-Ran;Park, Min-Im;Lee, Hyo-Soon;Kim, So-Hyun;Park, Jin-Kyong;Kim, Ji-Soo
    • Child Health Nursing Research
    • /
    • v.14 no.2
    • /
    • pp.129-137
    • /
    • 2008
  • Purpose: To examine the effects on skin injury, pain, and anxiety when nurses and children simultaneous wash their hands before IV injections. Method: A nonequivalent control group, non-synchronized design study was used with 61 children. For a month and a half, children in the experimental group(30) following hand-washing guidelines, washed their hands with nurses before IV insertion. Anxiety and pain were observed and recorded during IV insertion using the Anxiety Reaction Scale and FACES pain scale. After 48-72 hours on IV therapy with an arm-board, skin condition was checked by a research assistant according to guidelines for assessing skin injury developed by the researcher. t-test, ${\chi}^2$-test, Pearson correlation, and Kendall's tau b were used to analyze data with the SPSS program. Results: Children who washed their hands with the nurse before IV insertion showed less pain (p =.021) and skin injury (p <.001) compared to the control group. Conclusion: This finding suggests that simultaneous hand washing by nurse and child before IV injection has a strong effect on skin injury caused by arm-boards used to maintain IV therapy as well as on pain during IV insertion. This program demonstrates an effective intervention to prevent skin injuries in children on IV therapy.

  • PDF