• Title/Summary/Keyword: Injection System

Search Result 3,498, Processing Time 0.028 seconds

Determination Method of Hydrocarbon Compounds in DME-LPG Blending Fuels by Gas Chromatography with Deans Switching (Deans Switching을 이용한 가스크로마토그래피에서 DME-LPG 혼합연료의 탄화수소 화합물 분석방법)

  • Youn, Ju Min;Park, Cheon Kyu;Yim, Eui Soon;Jung, Choong Sub
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.353-357
    • /
    • 2012
  • The new qualitative and quantitative analytical method for hydrocarbon compounds in DME-LPG blending fuel, mixing dimethyl ether (DME) with liquefied petroleum gas (LPG), by using gas chromatography (GC) was investigated. It is difficult to analyze all components of DME-LPG blending fuel by using single column in GC due to consisting of the non-polar LPG and the polar DME which is oxygen-containing compound. Therefore, it has been introduced the Deans switching system, which are useful for analyzing mixtures of a very different nature and/or target analytes in very complex matrix. This technique is to control the pressure between two columns and to selectively change the path of effluent flows to either one of two columns. As a result, we found that DME and LPG can be completely separated at the different columns and the determination of all hydrocarbon compounds in DME-LPG blending fuel can be achieved to this method qualitatively and quantitatively during the operation of one injection. In addition, this method can be applied to the determination of trace components of by-product, such as methanol, methyl formate and ethyl methyl ether, which will be derived from DME synthesis process.

Computational Fluid Dynamics(CFD) Simulation for a Pilot-scale Selective Non-catalytic Reduction(SNCR) Process Using Urea Solution (요소용액을 이용한 파일럿규모 SNCR 공정에 대한 CFD 모델링 및 모사)

  • Nguyen, Thanh D.B.;Kang, Tae-Ho;Lim, Young-Il;Kim, Seong-Joon;Eom, Won-Hyeon;Yoo, Kyung-Seun
    • Korean Chemical Engineering Research
    • /
    • v.46 no.5
    • /
    • pp.922-930
    • /
    • 2008
  • The selective non-catalytic reduction(SNCR) performance is sensitive to the process parameters such as flow velocity, reaction temperature and mixing of reagent(ammonia or urea) with the flue gases. Therefore, the knowledge of the velocity field, temperature field and species concentration distribution is crucial for the design and operation of an effective SNCR injection system. In this work, a full-scale two-dimensional computational fluid dynamics(CFD)-based reacting model involving a droplet model is built and validated with the data obtained from a pilot-scale urea-based SNCR reactor installed with a 150 kW LPG burner. The kinetic mechanism with seven reactions for nitrogen oxides($NO_x$) reduction by urea-water solution is used to predict $NO_x$ reduction and ammonia slip. Using the turbulent reacting flow CFD model involving the discrete droplet phase, the CFD simulation results show maximum 20% difference from the experimental data for NO reduction. For $NH_3$ slip, the simulation results have a similar tendency with the experimental data with regard to the temperature and the normalized stoichiometric ratio(NSR).

Alterations of Cerebral Metabolic Activation Following Electro-Acupuncture Stimulation on ST36 and LR3 Acu-Points in Rats (흰쥐의 족삼리 및 태충 전침자극에 따른 뇌대사활성의 변화)

  • Sohn, Young-Joo;Jung, Hyuk-Sang;Ku, Ja-Seung;Won, Ran;Kim, Yong-Suk;Park, Young-Bae;Sohn, Nak-Won
    • Journal of Acupuncture Research
    • /
    • v.19 no.1
    • /
    • pp.159-174
    • /
    • 2002
  • Objective : The meridian theory in oriental medicine explains that each acu-point has a characteristic functional effect. It will be supposed that an acupuncture stimulation on different acu-point evokes different activation on different areas in the central nervous system(CNS) according to the meridian theory. On this supposition, our group tried the semi-quantitative [14C]2-deoxyglucose([14C]2-DG) autoradiography on the acupuncture stimulation to the hindlimb acu-points of Sprague-Dawley rats. Methods : A venous catheter for the intravenous administration of isotope was equipped in the right external jugular vein on 3 days prior to the [14C]2-DG study. On the day of the study, two acupuncture needles were inserted into the ST36(Zusanli) or LR3(Taichong) on the left hindlimb. Electro-acupuncture stimulation (2 Hz, 5 ms, 1~3 mA, 15 minutes) started just before the i.v. injection of [14C]2-DG ($25{\mu}Ci/rat$). The brain and the spinal cord were removed and processed for the [14C] 2-DG autoradiography. Results : The EA stimulation on ST36 reveals over 120% metaboilc activation in Arcuate nucleus, Anterior pretectal nucleus, Dorsal cochlear nucleus, Interposed cerebellar nucleus, and Nucleus of Darkschewitsch. The EA stimulation on LR3 reveals over 120% metaboilc activation in Lateral habenula nucleus, Medial vestibular nucleus, Ventromedial thalamic nucleus, Anteroventral thalamic nucleus, Anterior cingulate cortex, Dentate gyrus, Antero cortical amygdaloid nucleus, Anterior pretectal nucleus, and Dorsal tegmental nucleus compared with the non EA stimulation control group. Conclusion : These results demonstrate that the different acu-points evoke the different activations in brain areas. And with this functional brain mapping study, a new scientific elucidation for the basis of the acupuncture-meridian theory in oriental medicine through differences of activated area in CNS according to the each acupuncture point.

  • PDF

Carbonization Patten and Operation Characteristics of a 1Φ 2 W MCCB Damaged by PCITS (PCITS에 의해 소손된 1Φ 2 W MCCB의 탄화 패턴 및 작동 특성)

  • Lee, Jae-Hyuk;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.8-13
    • /
    • 2014
  • The purpose of this study is to analyze the damage pattern when overcurrent is applied to a thermal magnetic type molded case circuit breaker (MCCB) using a Primary Current Injection Test System (PCITS). When an overcurrent of 150 A was applied to the PCITS for 5 seconds with the trip bar of an MCCB being damaged, it was found that the surface of the temperature control device (bimetallic strip) positioned at the right was significantly carbonized. When an overcurrent of 300 A was applied to the PCITS for 5 s under the same conditions, the entire temperature control device was deteriorated, becoming flattened and in close contact with the MCCB. When an overcurrent of 450 A was applied to the PCITS for 5 s, the coil of the temperature control device was melted and disconnected. In addition, it was observed that the contacts, the enclosure and upper cover were deformed and there was a trace of carbonization on them. When approximately 3 s had elapsed after an overcurrent of 600 A was applied, white smoke occurred inside the MCCB and a flame was radiated out, after which the overcurrent supply stopped with "phutt" (whomp) sound. It was observed that when the same type of MCCB is damaged by a general flame, the surfaces of its handle, terminal, arc divider (extinguisher) and temperature control device were carbonized uniformly. In addition, it was found that the trip bar of the operating mechanism was melted down and the metal operation pin was moved while being tripped.

Acupuncture in Patients with a Vertebral Compression Fracture: A Protocol for a Randomized, Controlled, Pilot Clinical Trial

  • Lee, Hyun-Jong;Seo, Jung-Chul;Park, Sung-Hoon;Kwak, Min-Ah;Shin, Im Hee;Min, Bo-Mi;Cho, Min-Su;Roh, Woon-Seok;Jung, Jin-Yong
    • Journal of Pharmacopuncture
    • /
    • v.18 no.1
    • /
    • pp.79-85
    • /
    • 2015
  • Objectives: A vertebral compression fracture (VCF) is characterized by back pain and fracture of a vertebral body on spinal radiography. VCFs of the thoraco lumbar spine are common in the elderly. In general, appropriate analgesics should be prescribed to reduce pain and, thus, promote early mobilization. The ideal treatment approach for VCFs has not been determined. In Korea, acupuncture and herbal medication have been used to treat VCFs for many years. There is empirical evidence that acupuncture might benefit patients with a VCF. However, no randomized, controlled, clinical trials evaluating the efficacy and the safety of acupuncture for treating a VCF have been published. Therefore, we designed a randomized, controlled, pilot, clinical trial to obtain information for the design of a further full scale trial. Methods: A five week protocol for a randomized, controlled, pilot, clinical trial is presented. Fourteen patients will be recruited and randomly allocated to two groups: a control group receiving interlaminar epidural steroid injections once a week for three weeks, and an experimental group receiving interlaminar epidural steroid injections plus acupuncture treatment (three acupuncture sessions per week for three weeks, nine sessions in total). The primary outcomes will be the pain intensity (visual analogue scale and PainVision$^{TM}$ system). The secondary outcome measurements will be the answers on the short form McGill pain questionnaire and the oswestry disability index. Assessments will be made at baseline and at one, three, and five weeks. The last assessment (week five) will take place two weeks after treatment cessation. This study will provide both an indication of feasibility and a clinical foundation for a future large scale trial. The outcomes will provide additional resources for incorporating acupuncture into existing treatments, such as nonsteroidal anti-inflammatory medications, narcotics and vertebral augmentation. This article describes the protocol.

Repeated Intramuscular-dose Toxicity Test of Water-soluble Carthami Flos (WCF) Pharmacopuncture in Sprague-Dawley Rats

  • Choi, Yoo-Min;Jung, Da-Jung;Kim, Seok-Hee;Kim, Jong-Uk;Yook, Tae-Han
    • Journal of Pharmacopuncture
    • /
    • v.18 no.1
    • /
    • pp.36-43
    • /
    • 2015
  • Objectives: Water-soluble carthami flos (WCF) is a new mixture of Carthami flos (CF) pharmacopuncture. We conducted a 4-week toxicity test of repeated intramuscular injections of WCF in Sprague-Dawley rats. Methods: Forty male and 40 female rats were divided into 4 groups of 10 male and 10 female SD rats: The control group received 0.5 mL/animal/day of normal saline whereas the three experimental groups received WCF at doses of 0.125, 0.25, and 0.5 mL/animal/day, respectively. For 4 weeks, the solutions were injected into the femoral muscle of the rats alternating from side to side. Clinical signs, body weights, and food consumption were observed; opthalmological examinations and urinalyses were performed. On day 29, blood samples were taken for hematological and clinical chemistry analyses. Then, necropsy was conducted in all animals to observe weights and external and histopathological changes in the bodily organs. All data were tested using a statistical analysis system (SAS). Results: No deaths were observed. Temporary irregular respiration was observed in male rats of the experimental group for the first 10 days. Body weights, food consumptions, opthalmological examinations, urinalyses, clinical chemistry analyses, organ weights and necropsy produced no findings with toxicological meaning. In the hematological analysis, delay of prothrombin time (PT) was observed in male rats of the 0.25- and the 0.5-mL/animal/day groups. In the histopathological test, a dose-dependent inflammatory cell infiltration into the fascia and panniculitis in perimuscular tissues was observed in all animals of the experimental groups. However, those symptoms were limited to local injection points. No toxicological meanings, except localized changes, were noted. Conclusion: WCF solution has no significant toxicological meaning, but does produce localized symptoms. No observed adverse effect level (NOAEL) of WCF in male and female rats is expected for doses over 0.5 mL/animal/day.

Design of MTP memory IP using vertical PIP capacitor (Vertical PIP 커패시터를 이용한 MTP 메모리 IP 설계)

  • Kim, Young-Hee;Cha, Jae-Han;Jin, Hongzhou;Lee, Do-Gyu;Ha, Pan-Bong;Park, Mu-Hun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.1
    • /
    • pp.48-57
    • /
    • 2020
  • MCU used in applications such as wireless chargers and USB type-C require MTP memory with a small cell size and a small additional process mask. Conventional double poly EEPROM cells are small in size, but additional processing masks of about 3 to 5 sheets are required, and FN tunneling type single poly EEPROM cells have a large cell size. In this paper, a 110nm MTP cell using a vertical PIP capacitor is proposed. The erase operation of the proposed MTP cell uses FN tunneling between FG and EG, and the program operation uses CHEI injection method, which reduces the MTP cell size to 1.09㎛2 by sharing the PW of the MTP cell array. Meanwhile, MTP memory IP required for applications such as USB type-C needs to operate over a wide voltage range of 2.5V to 5.5V. However, the pumping current of the VPP charge pump is the lowest when the VCC voltage is the minimum 2.5V, while the ripple voltage is large when the VCC voltage is 5.5V. Therefore, in this paper, the VPP ripple voltage is reduced to within 0.19V through SPICE simulation because the pumping current is suppressed to 474.6㎂ even when VCC is increased by controlling the number of charge pumps turned on by using the VCC detector circuit.

A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type (하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

Effect of Bacterial Population from Rhizosphere of Various Foliage Plants on Removal of Indoor Volatile Organic Compounds (다양한 관엽식물의 근권부 박테리아 집단이 실내 휘발성 유기화합물질의 제거에 미치는 영향)

  • Chun, Se-Chul;Yoo, Mung-Hwa;Moon, Young-Sook;Shin, Mi-Ho;Son, Ki-Cheol;Chung, Ill-Min;Kays, Stanley J.
    • Horticultural Science & Technology
    • /
    • v.28 no.3
    • /
    • pp.476-483
    • /
    • 2010
  • Total bacterial populations were cultured from the Hydroball cultivation media in the rhizospheres of 9 different plants including $Hedera$ $helix$ L. and $Dracaena$ $deremensis$ cv. Warneckii Compacta, etc. These cultured bacterial populations were studied to test if the bacterial populations in the plant growing pots may play a role on removal of volatile organic compounds (VOCs) such as benzene and toluene in the air. To meet this objective, first, we tested the possibility of removal of VOCs by the cultured total bacteria alone. The residual rates of benzene by the inoculation of total bacterial populations from the different plant growth media were significantly different, ranging from 0.741-1.000 of $Spathiphyllum$ $wallisii$ 'Regal', $Pachira$ $aquatica$, $Ficus$ $elastica$, $Dieffenbachia$ sp. 'Marrianne' Hort., $Chamaedorea$ $elegans$, compared to the control with residual rate of 0.596 (LSD, $P$=0.05). This trend was also similar with toluene, depending on different plants. Based on these results, we inoculated the bacterial population cultured from $P.$ $aquatica$ into the plant-growing pots of $P.$ $aquatica$, $F.$ $elastica$, and $S.$ $podophyllum$ inside the chamber followed by the VOCs injection. The inoculated bacteria had significant effect on the removal of benzene and toluene, compared to the removal efficacy by the plants without inoculation, indicating that microbes in the rhizosphere could play a significant role on the removal of VOCs along with plants.

Assessment of Pubertal Development to Parabens-induced Estrogenic Effect in Male Mice (파라벤류가 수컷 성 성숙에 미치는 시험연구)

  • Kim, Sun-Jung;Hwang, Jae-Woong;Park, Jung-Ran;Lee, Seong-Hun;Lee, Yeong-Geon;Chung, Ji-Hye;Jeong, Yun-Hyeok;Lee, Soo-Jin;Jung, Ji-Won;Jung, Ji-Youn;Lee, Yong-Soon;Kang, Kyung-Sun
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.4
    • /
    • pp.197-203
    • /
    • 2006
  • Parabens are most wildly used in food, cosmetics and pharmaceutic products as preservatives caused of safety and cheap. we had examined that paraben had estrogenic activity through the in vivo and in vitro experiments in last year. We demonstrated that most of parabens(ethyl, butyl, propyl, isobutyl, isopropyl) increased significantly uterus weight as well as induced proliferation of MCF-7 cell and binding of estrogen receptor as endocrine disrupter compounds. In this study, we evaluated that whether parabens have effect on male reproductive system or not. the male rats were administrated parabens by oral injection then examined separation of preputial day for $PND23\simPND52$. As the results, most parabens delayed pubertal development compare to control group. The separation of preputial day of Butyl and Propyl parabens at high concentration were PND 44 days and PND 45days compared to control group as PND 40 days. Even though, parabens as endocrine disrupter wildly spread in food, cosmetics and pharmaceutic products, we didn't have the safe guideline. In abroad, they are re-evaluating safety assessment for parabens. In conclusion, parabens delayed pubertal development in juvenile parabens are consider as endocrine disrupter chemicals.