• Title/Summary/Keyword: Injection Amount

Search Result 883, Processing Time 0.033 seconds

Evaluation of IC Electromagnetic Conducted Immunity Test Methods Based on the Frequency Dependency of Noise Injection Path (Noise Injection Path의 주파수 특성을 고려한 IC의 전자파 전도내성 시험 방법에 관한 연구)

  • Kwak, SangKeun;Kim, SoYoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.4
    • /
    • pp.436-447
    • /
    • 2013
  • In this paper, Integrated circuit(IC) electromagnetic(EM) conducted immunity measurement and simulation using bulk current injection(BCI) and direct power injection(DPI) methods were conducted for 1.8 V I/O buffers. Using the equivalent circuit models developed for IC electromagnetic conducted immunity tests, we investigated the reliability of the frequency region where IC electromagnetic conducted immunity test is performed. The insertion loss for the noise injection path obtained from the simulation indicates that using only one conducted immunity test method cannot provide reliable conducted immunity test for broadband noise. Based on the forward power results, we analyzed the actual amount of EM noise injected to IC. We propose a more reliable immunity test methods for broad band noise.

Study on the Optimal Injection Condition for HC-LNT Catalyst System for Diesel Engines with a Gasoline PFI Type Injector (가솔린 인젝터를 디젤엔진용 HC-LNT 촉매에 적용하기 위한 최적 분사 조건에 관한 연구)

  • Oh, Jung-Mo;Mun, Woong-Ki;Kim, Ki-Bum;Lee, Jin-Ha;Lee, Ki-Hyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.2
    • /
    • pp.121-127
    • /
    • 2011
  • NOx (Nitrogen Oxide) reduction system periodically needs a rich or stoichiometric operating condition to reduce NOx. A new method that optimizes the control of external HC injection into a diesel exhaust pipe for HC-type LNT (Lean NOx Trap) catalyst system has been developed. In this paper, these catalysts are called HC-LNT catalysts. The concentration and amount of HC can be controlled by controlling the external injection. In this study, we investigated the relationship between the spray behavior of hydrocarbons injected into the transparent exhaust pipe and NOx reduction characteristics. From the results of this experiment, we obtained useful information about the optimum injection and position of HC injector to the exhaust pipe. Further, we obtained useful information about the optimal injection condition for an HC-LNT catalyst system with a gasoline PFI (port fuel injection) typeinjector.

Computational Thermo-Fluid Analysis for the Effects of Helium Injection Methods on Glass Fiber Cooling Process in an Optical Fiber Manufacturing System (광섬유 냉각장치의 헬륨 주입기 설계를 위한 전산열유동해석)

  • Park, Shin;Kim, Kyoungjin;Kim, Dongjoo;Park, Junyoung;Kwak, Ho Sang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.124-130
    • /
    • 2014
  • In a mass manufacturing system of optical fibers, the sufficient cooling of glass fibers freshly drawn from a draw furnace is essential, asinadequately cooled glass fibers can lead to poor resin coating on the fiber surface and possibly fiber breakage during the process. In order to improve fiber cooling at a high drawing speed, it is common to use a helium injection into a glass fiber cooling unit in spite of the high cost of the helium supply. The present numerical analysis carried out three-dimensional thermo-fluid computations of the cooling gas flow and heat transfer on moving glass fiber to determine the cooling performance of glass fiber cooling depending on the method of helium injection. The results showed that afront injection of helium is most effective compared to a uniform or rear injection for reducing air entrainment into the unit and thus cooling the glass fibers at a high fiber drawing speed. However, above a certain amount of injected helium, there was no more increase of the cooling effect regardless of the helium injection method.

Icing Characteristics in Liquid-Phase Injection of LPG Fuel (액상분사식 LPG 인젝터의 아이싱 생성 특성 및 억제 방법)

  • Lee, Sun-Youp;Kim, Chang-Up;Choi, Kyo-Nam;Kang, Kern-Yong
    • Journal of ILASS-Korea
    • /
    • v.14 no.4
    • /
    • pp.147-152
    • /
    • 2009
  • Since a liquid-phase LPG injection system allows accurate control of fuel injection and increase in volumetric efficiency, it has advantages in achieving higher engine power and lower emissions compared to the mixer type LPG supplying system. However, this system also leads to an unexpected event called icing phenomenon which occurs when moisture in the air near the injector freezes and becomes frost around the nozzle hole due to extraction of heat from surrounding caused by instant fuel vaporization. As a result, it becomes difficult to control air/fuel ratio in engine operation, inducing exacerbation of engine performance and HC emission. One effort to mitigate icing phenomenon is to attach anti-icing injection tip in the end of nozzle. Therefore, in this study, the effect of engine operation parameters as well as surrounding conditions on icing phenomenon was investigated in a bench test rig with commercially-used anti-icing injection tips. The test results show that considerable ice was deposited on the surface near the nozzle hole of the anti-icing tip in low rpm and low load operating conditions in ambient air condition. This is because acceleration of detachment of deposited ice from the tip surface was induced in high load, high rpm conditions, resulting in decrease in frost accumulation. The results of the bench testing also demonstrate that little or no ice was formed at surrounding temperature below a freezing point since the absolute amount of moisture contained in the intake air is too small in such a low temperature.

  • PDF

THE LEVEL OF RESIDUAL MONOMER IN INJECTION MOLDED DENTURE BASE MATERIALS

  • Lee Hyeok-Jae;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.360-368
    • /
    • 2003
  • Statement of Problem: The residual monomer of denture base materials causes hypersensitivity on oral mucosa and intereferes with the mechanical properties of the cured resin. The amount of residual monomer is influenced by materials, curing cycle, processing method, and etc. Purpose: The aim of this study was to investigate the residual methyl methacrylate(MMA) content of injection molded denture base polymer, and to compare this with the self-cured resin and the conventional compression molded heat-cured resin. Materials and Methods: Disc shaped test specimens (50mm in diameter and 3mm thick) were prepared in a conventional flasking technique with gypsum molding. One autopolymerized denture base resins (Vertex Sc. Dentimex. Netherlands) and two heat-cured denture base resins (Vertex RS. Dentimex. Netherlands, Ivocap. Ivoclar Vivadent, USA) were used. The three types of specimens were processed according to the manufacturer's instruction. After polymerization, all specimens were stored in the dark at room temperature for 7 days. There were 10 specimens in each of the test groups. 3-mm twist drills were used to obtain the resin samples and 650mg of the drilled sample were collected for each estimation. Gas chromatography (Agillent 6890 Plus Gas Chromatograph, Agillent Co, USA) was used to determine the residual MMA content of 10 test specimens of each three types of polymer. Results: The residual monomer content of injection molded denture base resins was $1.057{\pm}0.141%$. The residual monomer content of injection molded denture base resins was higher than that of compression molded heat cured resin ($0.867{\pm}0.169%$). However, there was no statistical significant difference between two groups (p>0.01). The level of residual monomer in self cured resin($3.675{\pm}0.791$) was higher than those of injection molded and compression molded heat cured resins (p<0.01). Conclusion: With respect to ISO specification pass / fail test (2.2% mass fraction) of residual monomer, injection molding technique($1.057{\pm}0.141%$) is a clinically useful and safe technique in terms of residual monomer.

Studies of Thyroid Function Test Using Radioiodine by Intradermal Injection (방사성(放射性) 옥소(沃素) 피내(皮內) 주사(注射)에 의(依)한 갑상선(甲狀腺) 기능검사(機能檢査)에 관(關)한 연구(硏究))

  • Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.6 no.1
    • /
    • pp.41-49
    • /
    • 1972
  • The author observed the thyroid $^{131}I$ uptake rate using an intradermal injection method. The amount of activity remaining at the site of intradermal injection of 0.1 ml. of $5{\mu}Ci.\;of\;^{131}I$ in physiologic saline was measured in 79 cases of hyperthyroidism and in 24 cases of hypothyroidism. The cases had been confirmed by clinical and laboratory findings, at the department of medicine, (radioisotope clinic) Pusan National University Hospital. Twenty-nine normal control cases were examined currently by the same technique during the period from Jan. 1967 to June 1970. The following results were obtained: 1. In the normal group, the ranges and mean values of the thyroid uptake 10, 15, 20, 25, 30 and 60 minutes after intradermal $^{131}I$ injection, were $0{\sim}10%(6.33{\pm}1.63),\;0{\sim}15%(7.83{\pm}2.12),\;0{\sim}15%(8.46{\pm}2.82),\;5.1{\sim}20%(9.66{\pm}2.27),\;5.1{\sim}25%(10.47{\pm}2.52),\;5.1{\sim}30%(13.03{\pm}4.42)$. 2. In the hyperthyroid group, the ranges and mean values of the thyroid uptake 10, 15, 20, 25, 30 and 60 minutes after intradermal $^{131}I$ injection were $5.1{\sim}45%(22.25{\pm}7.04),\;10.1{\sim}50%(28.32{\pm}6.67),\;15.1{\sim}55%(34.78{\pm}11.63),\;15.1{\sim}65%(37.95{\pm}7.72),\;20.1{\sim}65%(41.49{\pm}0.05)\;and\;20.18096(48.71{\pm}12.51)$. 3. In the hypothyroid group, he ranges of thyroid $^{131}I$ uptake by intradermal $^{131}I$ injection at 10, 15, 20, 25, 30 and 60 minutes lay between 0 and 10%, and the the mean values were $4.23{\pm}1.76,\;5.08{\pm}1.68,\;5.56{\pm}1.70,\;6.02{\pm}1.75,\;6.37{\pm}1.91\;and\;6.95{\pm}2.07$. 4. In conclusion, thyroid function test using an intradermal injection method in cases of hyperthyroidism, showed characteristic values which seemed to be of diagnostic significance.

  • PDF

Changes in External Radiation Dose Rate for PET-CT Test Patients (PET-CT 검사 환자의 외부 방사선량률 변화)

  • Kim, Su-Jin;Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.103-107
    • /
    • 2012
  • This paper analyzes changes in the external radiation dose rate of PET-CT test patients as a part of providing basic materials for reduction of radiation exposure to PET-CT test patients. In theory the measurement of external radiation dose rate of PET-CT test patients shows that the further the distance from the patient injected with radioactive pharmaceutical and a longer time elapsement from the injection leads to a smaller amount of radiation. Particularly, the amount of radiation marked the highest in the chest was at 4.17 minutes immediately after the intravenous injection and in the head after 77.47 minutes after urination in advance to the PET-CT test. As in the generalized information, it is desired to keep distance between the patient and caretakers or professionals to reduce the amount of radiation exposure from PET-CT test patients and to resume contact the patient after the time when the radiation has reduced. If contact is unavoidable, it is desired to keep at least 200cm from the patient. In addition, the amount of radiation reached the highest in the chest at first and then in the head from 77 minutes after injection. Accordingly, it would be helpful in achieving the optimization if contact is made based on the patient's physical characteristics. This study is significant as it measures changes in radiation the dose rate by; distance from the PET-CT test patient, time elapsed, and specific parts of body. Further studies based on the findings in this paper are required to analyze changes in radiation dose rate in accordance with individual characteristics unique to PET-CT patients and to utilize the results to reduce the amount of radiation patient, caretakers and professions are exposed.

Improved Injection Behavior with the Addition of Granulated β-Tricalcium Phosphate in Brushite Bone Cement

  • Jo, Hyun-Ho;Oh, Kyung-Sik
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.6
    • /
    • pp.590-596
    • /
    • 2018
  • To improve the injection behavior of brushite cement, dense ${\beta}-Ca_3(PO_4)_2$ (${\beta}-TCP$) granules were added to the starting material. The spherical ${\beta}-TCP$ granules prepared by spray-drying and subsequent sintering at $1000{\sim}1200^{\circ}C$ accounted for fractions of from 0.5 to 0.7 of the total ${\beta}-TCP$. The injection behavior was evaluated by measuring the injected mass divided by the loaded mass of paste in the syringe pump. The injected amount was increased with the increase in the fraction and sintering temperature of ${\beta}-TCP$ granules, except at $1200^{\circ}C$. The increase in the fraction of ${\beta}-TCP$ and its sintering temperature resulted in a decrease in the plastic limit, which is the volume of water required to liquefy the compact. The rest water could be utilized in the cement with the reduced plastic limit for improved injectability. The amounts of rest water assigned for powdery phase were estimated, and correlated with the injectability of paste.

Diffusion of Cr(VI) in Porous Media (심층 지하에서의 육가 크롬 확산)

  • 현재혁
    • The Journal of Engineering Geology
    • /
    • v.3 no.2
    • /
    • pp.203-214
    • /
    • 1993
  • Underground Injection Control regulations for Class I injection wells require that the vertical dufusion be considered as a mechanism for transport of contaninants in evaluating containment Due to the low permeability in the confining aquitard, the movement of contaminants over the long term is controlled by the molecular diffusion. The movement can be predicted, using the Fick' S second law of diffusion. The diffusion coefficient in Fick' s law has been determined experimentally in this study. Instantaneous injection of $^{51}Cr$ was used to trace the distribution of Cr(VI) in soil plugs and an analytical solution was applied to calculate the diffusion coefficients. This study shows the effect of environmental factors, such as temperature, chloride concentration, applied amount of $^{51}Cr$, and bulk density of injection formations on diffusion of Cr(VI)

  • PDF

A study on deformation of LSR injection moldings having the runners with same flow distance (동일 유동거리 런너를 가진 LSR 성형품의 변형에 관한 연구)

  • Park, Jeong-Yeon;Yoon, Gil-Sang;Lee, Jeong-Won;Choi, Jong Myeong
    • Design & Manufacturing
    • /
    • v.7 no.1
    • /
    • pp.60-63
    • /
    • 2013
  • Recently, Silicone that one of the thermo-sets is used to making optical products such as LED lenses because of excellent thermal properties. LED lenses are required to keep the precise dimensions, so they must be molded to have the minimum deformation. Thermo-sets have the expansion characteristic on the part of thermal property, it is important to optimize the cure condition so that the deformation of the part become minimum. In this study, to investigate the relationship between the shrinkage by the curing and expansion by the thermal properties of the resin, reactive injection experiment was performed by setting the variables such as mold setting temperature, cure time. As a result, it was confirmed that there was a interval while the thermal properties were transferred to more active during the cure process. It is expected to help in determining the reactive injection molding conditions of the thermo-set parts as well as LED lens in order to reduce the amount of deformation.

  • PDF