• 제목/요약/키워드: Initial ground temperature

검색결과 104건 처리시간 0.032초

응결시간과 겉보기 활성화 에너지를 이용한 고로슬래그 콘크리트의 압축강도 예측에 관한 연구 (Prediction of Compressive Strength Using Setting Time and Apparent Activation Energy of Blast Furnace Slag Concrete)

  • 김한솔;양현민;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.101-102
    • /
    • 2021
  • The compressive strength of concrete is greatly affected by the temperature inside the concrete at the initial age immediately after pouring. The apparent activation energy of cement and the setting time of concrete are major factors influencing the development of compressive strength of concrete. This study measured the apparent activation energy and setting time according to the change in W/B for each mixing rate of Ground Granulated Blast-Furnace Slag (GGBFS). And after calculating the compressive strength prediction model, the accuracy of the prediction model was evaluated by comparing the predicted compressive strength and the compressive strength.

  • PDF

Effects of Extrusion Variable on Functional and Nutritional Properties of Extruded Oat Products

  • Gutkoski, Luiz Carlos;El-Dash, Ahmed Atia
    • Preventive Nutrition and Food Science
    • /
    • 제4권3호
    • /
    • pp.159-162
    • /
    • 1999
  • The purpose of this research was to study the effects of initial moisture levels and extrusion temperatures on dietary fiber, nitrogen solubility index, available lysine, and the in vitro protein digestibility of extruded oat productes. The dehulled grains were ground in a Brabender quadrumat Senior mill and the coarse fraction, with higher crude protein, lipids and dietary fiber were conditioned on various mositre levels (15.5~25.5%) and extruded in a Brabender single-screw laboratory extruder. The extrudates showed a higher amount of soluble dietary fiber (8.14%) than in the raw material . However, the extrusion process affected the nutritional value of the protein due to a decrease in available lysine with increased temperature . The in vitro protein digestibility was unaffected by initial moisture levels and the extrusion temperatures examined.

  • PDF

지열 성능해석 시뮬레이션에 기반한 최적 설계 수법 개발 (Development of Optimum Design Method for Geothermal Performance based on Energy Simulation)

  • 문형진;김홍교;남유진
    • 대한건축학회논문집:구조계
    • /
    • 제35권3호
    • /
    • pp.43-48
    • /
    • 2019
  • Since the revision of the Rationalization of Energy Use Law, the spread of new and renewable energy in buildings has been promoted. In addition, the production of electric power and thermal energy is an important issue in the change of energy paradigm centered on the use of distributed energy. Among them, geothermal energy is attracting attention as a high-performance energy-saving technology capable of coping with heating / cooling and hot water load by utilizing the constant temperature zone of the earth. However, there is a disadvantage that the initial investment cost is high as a method of calculating the capacity of a geothermal facility by calculating the maximum load. The disadvantages of these disadvantages are that the geothermal energy supply is getting stagnant and the design of the geothermal system needs to be supplemented. In this study, optimization design of geothermal system was carried out using optimization tool. As a result of the optimization, the ground heat exchanger decreased by 30.8%, the capacity of the heat pump decreased by 7.7%, and the capacity of the heat storage tank decreased by about 40%. The simulation was performed by applying the optimized value to the program and confirmed that it corresponds to the load of the building. We also confirmed that all of the constraints used in the optimization design were satisfied. The initial investment cost of the optimized geothermal system is about 18.6% lower than the initial investment cost.

Hybrid thermal seasonal storage and solar assisted geothermal heat pump systems for greenhouses

  • Ataei, Abtin;Hemmatabady, Hoofar;Nobakht, Seyed Yahya
    • Advances in Energy Research
    • /
    • 제4권1호
    • /
    • pp.87-106
    • /
    • 2016
  • In this research, optimum design of the combined solar collector, geothermal heat pump and thermal seasonal storage system for heating and cooling a sample greenhouse is studied. In order to optimize the system from technical point of view some new control strategies and functions resulting from important TRNSYS output diagrams are presented. Temperatures of ground, rock bed storage, outlet ground heat exchanger fluid and entering fluid to the evaporator specify our strategies. Optimal heat storage is done with maximum efficiency and minimum loss. Mean seasonal heating and cooling COPs of 4.92 and 7.14 are achieved in series mode as there is no need to start the heat pump sometimes. Furthermore, optimal parallel operation of the storage and the heat pump is studied by applying the same control strategies. Although the aforementioned system has higher mean seasonal heating and cooling COPs (4.96 and 7.18 respectively) and lower initial cost, it requires higher amounts of auxiliary energy either. Soil temperature around ground heat exchanger will also increase up to $1.5^{\circ}C$ after 2 years of operation as a result of seasonal storage. At the end, the optimum combined system is chosen by trade-off between technical and economic issues.

킥 모터 지상 시험의 플룸 복사 열유속 측정 (Measurement of Radiative Heat Flux of Kick Motor at Ground Test)

  • 김성룡;최상호;고주용;김인선
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.440-443
    • /
    • 2008
  • Plume radiation has been measured during ground tests of KSLV-I kick motor in order to predict the thermal load on the equipment around the kick motor at flight. The measuring positions are the kick motor base, and the measured heats were about 2${\sim}$5 w/cm$^2$. The measured heat showed a lot of shot fluctuation in their values, and the radiative heats at the latter half of time are higher than those of the first half. A plausible explanation for these phenomena was given as the variation of alumina particles with time. The radiative heats along the plume axis were also measured recently at 8 positions with 1.5m radius from plume axis, but only the initial parts of the results could be acceptable because the sensor were damaged by the accumulated heat. The strongest heat occurred at the middle of the plume, which can be explained with different view factors. Despite of the plausible explanation, it seems to need more analysis because the plume structure such as temperature, alumina particle, after burning has not been revealed until yet. The measure heat flux has been reflected in the prediction of the plume radiation at high altitude where the kick motor operates.

  • PDF

지열 냉난방 시스템의 성능 및 경제성 평가 (Performance Evaluation and Economic Estimation of Ground Source Heat Pump Cooling and Heating System)

  • 임효재;송윤석;공형진;박성구
    • 에너지공학
    • /
    • 제13권4호
    • /
    • pp.296-300
    • /
    • 2004
  • 본 연구는 지열원 물 대 물(water to water)히트 펌프 시스템의 냉방 및 난방 운전시 성능 특성과 경제성 평가에 관한 것이다. 5개의 보어홀당 지중 100m의 깊이로 밀폐 수직형 지중 열교환기(closed-vertical ground source)가 설치된 냉난방 시스템이 적용된 건축물에 대하여 냉난방 운전성능을 평가하였으며, 연간 소비전력을 측정하여 실제 시스템의 경제성을 분석하였다. 또한, 순환수의 입구온도에 따른 시스템의 운전 성능을 분석한 결과 난방시에는 COP가 3.0에서 4.2로 증가한 반면, 냉방시에는 5.0에서 3.7로 감소하였다. 본 실험을 통해서,대상 건축물에 대한 지열 냉난방 시스템의 수명주기비용은 기존 냉난방 시스템(보일러+에어컨)에 비해서 68%까지 절감되었으며, 시스템의 경제성을 고려해 볼 때 기존 건축물에도 지열원 냉난방 시스템을 적용하는 것이 타당하다.

대청댐 예비 방류를 위한 홍수 예보 (Flood Forecasting for Pre-Release of Taech'ong Reservoir)

  • 이재형;심명필;전일권
    • 물과 미래
    • /
    • 제26권2호
    • /
    • pp.99-105
    • /
    • 1993
  • 호우발생전의 기상상태, 유역의 저류상태 그리고 과거의 패턴을 반영한 실용성 있는 홍수 예보모형을 제안하였다. 호우 예보는 구름 물리학을 토대로한 지점 호우 예보 모형을, 유출예측은 저류함수모형을 채택하였다. 홍수 예보 모형의 입력 변수는 예보 발령 시점의 지상 기온, 지상 기압, 지상 이슬점 온도 그리고 유출점의 초기 유량이다. 홍수 예보 모형의 매개 상수는 과거의 홍수 사상이 갖는 최적 상수들의 산술평균값으로 하였다. 유출률은 홍수 초기 유량을 지표로 하여 예측될 수 있게 하였다.

  • PDF

강변여과수(충적층 및 하상)를 이용한 열펌프 냉난방시스템의 실증연구 (The Field Test of bankfiltration(including alluvial and riverbed deposits) Source Heat Pump Cooling & Heating System)

  • 황기섭;정우성;안영섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1186-1190
    • /
    • 2006
  • Rising in important of alternative energy due to the recenfly high oil price and environment problem. Application of alternative energy has become higher than before. In this study, facility test of Geothermal energy to bankfiltration was examined appliying changwon pumping well. Initial installation cost was efficiently saved by connecting a heat pump system to pumping well in changwon bankfiltration site. A falling-off in efficiency of heat pump was free due to the bankfiltration that is rare for the temperature fluctuation. Therefore, Heat soure as bankfiltration system solve the existing facilities problems of geothermal heat pump system.

  • PDF

유해화학물질 대기확산 예측을 위한 RAMS 기상모델의 적용 및 평가 - CARIS의 바람장 모델 검증 (Application and First Evaluation of the Operational RAMS Model for the Dispersion Forecast of Hazardous Chemicals - Validation of the Operational Wind Field Generation System in CARIS)

  • 김철희;나진균;박철진;박진호;임차순;윤이;김민섭;박춘화;김용준
    • 한국대기환경학회지
    • /
    • 제19권5호
    • /
    • pp.595-610
    • /
    • 2003
  • The statistical indexes such as RMSE (Root Mean Square Error), Mean Bias error, and IOA (Index of agreement) are used to evaluate 3 Dimensional wind and temperature fields predicted by operational meteorological model RAMS (Regional Atmospheric Meteorological System) implemented in CARIS (Chemical Accident Response Information System) for the dispersion forecast of hazardous chemicals in case of the chemical accidents in Korea. The operational atmospheric model, RAMS in CARIS are designed to use GDAPS, GTS, and AWS meteorological data obtained from KMA (Korean Meteorological Administration) for the generation of 3-dimensional initial meteorological fields. The predicted meteorological variables such as wind speed, wind direction, temperature, and precipitation amount, during 19 ∼ 23, August 2002, are extracted at the nearest grid point to the meteorological monitoring sites, and validated against the observations located over the Korean peninsula. The results show that Mean bias and Root Mean Square Error are 0.9 (m/s), 1.85 (m/s) for wind speed at 10 m above the ground, respectively, and 1.45 ($^{\circ}C$), 2.82 ($^{\circ}C$) for surface temperature. Of particular interest is the distribution of forecasting error predicted by RAMS with respect to the altitude; relatively smaller error is found in the near-surface atmosphere for wind and temperature fields, while it grows larger as the altitude increases. Overall, some of the overpredictions in comparisons with the observations are detected for wind and temperature fields, whereas relatively small errors are found in the near-surface atmosphere. This discrepancies are partly attributed to the oversimplified spacing of soil, soil contents and initial temperature fields, suggesting some improvement could probably be gained if the sub-grid scale nature of moisture and temperature fields was taken into account. However, IOA values for the wind field (0.62) as well as temperature field (0.78) is greater than the 'good' value criteria (> 0.5) implied by other studies. The good value of IOA along with relatively small wind field error in the near surface atmosphere implies that, on the basis of current meteorological data for initial fields, RAMS has good potentials to be used as a operational meteorological model in predicting the urban or local scale 3-dimensional wind fields for the dispersion forecast in association with hazardous chemical releases in Korea.

수치해석을 통한 강원지역 도로터널 라이닝 배면지반의 동결깊이 분석 (Numerical Analysis of Frost Depth behind the Lining of Road Tunnel in Gangwon Province)

  • 손희수;전경재;윤찬영
    • 한국지반환경공학회 논문집
    • /
    • 제18권3호
    • /
    • pp.15-23
    • /
    • 2017
  • 강원지역은 한국의 북동부에 위치하고 있으며 산지가 90%에 달해 한국에서 가장 추운 지역이다. 그에 따라 겨울철 터널 피해가 지속적으로 발생하고 있으나 아직 터널 라이닝 배면에서 발생하는 동상에 대한 연구는 매우 부족하다. 본 연구에서는 강원지역의 도로터널에서 발생하는 동상깊이 분석을 위한 수치적 연구를 수행하였다. 강원지역 도로터널 현황과 기후자료를 분석하고 이를 토대로 터널 표준 형상과 지반 특성을 가정하였으며, 기온 변화와 지반특성 변화에 따른 터널 배면지반의 최대 동상깊이를 산정하였다. 해석결과 모래보다 변성암 및 퇴적암의 동결민감성이 더 크며, 라이닝 배면의 초기 지중온도가 낮을수록 동상깊이가 깊어져 동결에 대한 피해도 커지는 것으로 나타났다. 또한 라이닝 두께 및 지반의 비열, 열전도율과 같은 특성도 동결깊이 변화에 큰 영향을 미치는 것으로 나타났다.