• Title/Summary/Keyword: Initial flow

검색결과 1,838건 처리시간 0.027초

Effect of NCO/OH ratio and binder content with micro-AP on HTPB/AP/Al-based propellants mechanical properties

  • Zulfam Adnan;Nurul Musfirah Mazlan
    • Advances in materials Research
    • /
    • 제13권2호
    • /
    • pp.129-140
    • /
    • 2024
  • This study evaluates the ratio of Toluene di-isocyanate (TDI) functional group isocyanate (NCO) to the binder functional hydroxyl group (OH) in HTPB/AP/Al-based propellants on their mechanical properties, flow rate, and viscosity to determine the limitations of NCO/OH in the composition of solid propellants. The propellants consisted of hydroxyl-terminated polybutadiene (HTPB) polyurethane (PU), aluminum (Al) and tri-modal ammonium perchlorate (AP). The tri-modal AP consisted of 30% of coarse AP, 30% of medium AP, and 8% of fine AP. The ratio of NCO/OH varies from 0.73 to 0.85, with two binder percentages of 10.5% and 12%. An increase in NCO/OH ratio with 10.5% binder provided 20%, 95%, and 8 to 9% increments in UTS, modulus, and hardness, respectively. However, the propellant elongation, density, and flow rate decreased by 170%, 0.2%, and 11-12%, respectively. Viscosity increased 20% based on initial hour reading. The 12% binder provides 27%, 47%, and 5~6% an increment of UTS, modulus and hardness respectively. However, the propellant elongation, density, and flow rate decreased by 47%, 0.17% and 27%, respectively. The viscosity increased 30% based on initial hour reading. This study suggests the NCO/OH value of 0.77 and 10.5~11% binder content in propellant based on the mechanical properties, flow rate, and viscosity for better processing and pot life.

Demonstration of Robust Micromachined Jet Technology and Its Application to Realistic Flow Control Problems

  • Chang Sung-Pil
    • Journal of Mechanical Science and Technology
    • /
    • 제20권4호
    • /
    • pp.554-560
    • /
    • 2006
  • This paper describes the demonstration of successful fabrication and initial characterization of micromachined pressure sensors and micromachined jets (microjets) fabricated for use in macro flow control and other applications. In this work, the microfabrication technology was investigated to create a micromachined fluidic control system with a goal of application in practical fluids problems, such as UAV (Unmanned Aerial Vehicle)-scale aerodynamic control. Approaches of this work include: (1) the development of suitable micromachined synthetic jets (microjets) as actuators, which obviate the need to physically extend micromachined structures into an external flow; and (2) a non-silicon alternative micromachining fabrication technology based on metallic substrates and lamination (in addition to traditional MEMS technologies) which will allow the realization of larger scale, more robust structures and larger array active areas for fluidic systems. As an initial study, an array of MEMS pressure sensors and an array of MEMS modulators for orifice-based control of microjets have been fabricated, and characterized. Both pressure sensors and modulators have been built using stainless steel as a substrate and a combination of lamination and traditional micromachining processes as fabrication technologies.

환상류-간헐류 천이 모텔이 드라이아웃 모델에 미치는 영향 평가 (Evaluation of the Effect of Annular-to-Intermittent Plow Transition Model on the Dryout Model)

  • 우상익;임인철
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.220-223
    • /
    • 2004
  • The initial conditions such as the film thickness and the void fraction at the onset of annular flow are required for the analytical dryout model. The Disturbance Wave Instability model(DWI model) is one of the model describing the Annular-to-Intermittent Flow regime Transition(AIFT). The experimental CHF conditions for the uniformly heated tube were compared with the predictions by the modified Levy model, for which the initial conditions at AIFT were estimated by the DWI model. For the flow through long tubes with small inlet subcooling, the effect of AIFT model on the dryout prediction was little. However, the use of DWI model gave better prediction of CHF in a short tube.

  • PDF

TiO2/UV공정을 이용한 수중 MTBE의 광분해 특성 (Characteristic of Photodegradation of MTBE Using TiO2/UV Process)

  • 류성필;김성수;오윤근
    • 한국환경과학회지
    • /
    • 제13권3호
    • /
    • pp.289-295
    • /
    • 2004
  • The objective of this study is to delineate removal efficiency of the MTBE in solution by $TiO_2$ photocatalytic degradation as a function of the following different experimental conditions: Initial concentration of MTBE, air flow rate in solution, $H_2O_2$ dosage and pH of the solution. Photodegradation rate was increased with decreasing initial concentration of MTBE. The removal efficiency was 82% after 180 min in the case of MTBE concentration of 100 mg/L but 100% after 180 min in the case of 20 mg/L. Removal efficiency was increased with increasing pH, $H_2O_2$ dosage and air flow rate in solution.

비선형 PSE를 이용한 압축성 경계층의 안정성 해석 (STABILITY ANALYSIS OF COMPRESSIBLE BOUNDARY LAYER IN CURVILINEAR COORDINATE SYSTEM USING NONLINEAR PSE)

  • ;박승오
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 추계 학술대회논문집
    • /
    • pp.134-140
    • /
    • 2007
  • Nonlinear parabolized stability equations for compressible flow in general curvilinear coordinate system are derived to deal with a broad range of transition prediction problems on complex geometry. A highly accurate finite difference PSE code has been developed using an implicit marching procedure. Blasius flow is tested. The results of the present computation show good agreement with DNS data. Nonlinear interaction can make the T-S fundamental wave more unstable and the onset of its amplitude decay is shifted downstream relative to linear case. For nonlinear calculations, rather small difference in initial amplitude can produce large change during nonlinear region. Compressible secondary instability at Mach number 1.6 is also simulated and showed that 1.1% initial amplitude for primary mode is enough to trigger the secondary growth.

  • PDF

수중방전에 의한 압력분포의 2차원 해석 (Two-Dimensional Analysis of Pressure Distribute by Underwater Electric Discharge)

  • Kim, Y.S.
    • 한국정밀공학회지
    • /
    • 제12권1호
    • /
    • pp.68-77
    • /
    • 1995
  • The two-dimensional pressure distribution, which is the most important parameter in the casting cleaning installations(CCI), was analyzed using the K-FIX computer program for two-phase flow. Modelling was done using R-Z coordinates for the initial and boundary conditions which don't have periodic influx and efflux, and also there was the electric discharge due to high pressure and temperature. The marked particles were introduced to prodict the structure and the size of main and local moving surfaces. The initial and boundary conditions were modified due to the internal structure of CCI.From the results of numerical analysis, it was shown that the maximum pressure on casting was increased with the increase of a water level. The pressure on casting in the radial direction was higher than that in axial direction. Also, it was proved that by introducing the marked particles it was possible to predict the surface structure in case of two-phase flow.

  • PDF

유한요소법을 이용한 난류유동해석 (The Turbulent flow analysis by the Finite Element Method)

  • 황상무
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 춘계학술대회논문집
    • /
    • pp.253-256
    • /
    • 1999
  • The Streamline Upwind Petrov-Galerkin(SUPG) finite element method is used to solve the two-dimensional laminar and turbulent flow. The flow is simulated by averaged Navier-Stokes equations with a penalty function approach and the lograithmic(k-$\varepsilon$) turbulent model is employed to take into account its turbulent behavior. The near-wall viscous sub-layer model is employed to approach the dominant viscous effects in the near wall zones. To find a good-enough initial guess of the Newton-Raphson iteration solving Nonlinear Matrix the Incremental method is considered for momentum and the Incomplete logarithmic turbu-lent equations for Turbulence. The validation of our method is investigated in comparision with published experimental data.

  • PDF

IPLAN을 이용한 UPFC 조류계산 모형 (UPFC model for power flow using IPLAN)

  • 국경수;김학만;전진홍;오태규;장병훈;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.316-318
    • /
    • 1998
  • This paper presents an approach that provides an equivalent initial operating condition of UPFC in load-flow study for stability analysis. The UPFC model for load-flow implemented by IPLAN in PSS/E is represented by an equivalent load injection. In doing so, the transmission line to which UPFC is connected is disconnected and the function of UPFC is represented by the equivalent load variation. This operating condition may not be adequate as an initial condition for subsequent dynamic simulation. The proposed approach provides a way of equivalencing UPFC load injection without line disconnection. The method was applied to a realistic power system for validity.

  • PDF

Capability of Thermal Field-Flow Fractionation for Analysis of Processed Natural Rubber

  • 이성호;은철훈
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권1호
    • /
    • pp.69-74
    • /
    • 2000
  • Applicability of Thermal field flow fractionation (ThFFF) was investigated for the analysis of masticated natural rubber (NR) adhesives produced bya hot melt mastication process. An optimum ThFFF condition for NR analysis was found by using tetrahydrofuran (THF) as a solvent/carrier and a field-programming. Low flowrate (0.3 mL/min) was used to avoid stopping the flow for the sample relaxation. Measured molecular weight distribution was used to monitor degradation of rubber during the mastication process. Rubber samples collected at three different stages of the mastication process and were analyzed by ThFFF. It was found that in an anaerobic process rubber degradation occurs at the resin-mixing (compounding) zone as well as in the initial break-down zone, while in an aerobic process most of degradation occurs at the initial breakdown zone. It was also found that E-beam radiation on NR causes a slight increase in the NR molecular weight due to the formation of a branched structure.

하나로 유동모의 시험설비의 노심채널 유동분포 해석 (The Analysis of Flow Distribution in the Core Channel of the HANARO Flow Simulated Test Facility)

  • 박용철;김경련
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 추계 학술대회논문집
    • /
    • pp.151-154
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulated test facility has been developed for the verification of structural integrity of those experimental facilities prior to loading In the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The half-core structure assembly is composed of plenum, grid plate, core channel with flow tubes, chimney and dummy pool. The flow channels are to be filled with flow orifices to simulate similar flow characteristics to the HANARO. This paper describes an analysis of the flow distribution of the cote channel and compares with the test results. As results, the analysis showed similar flow characteristics compared with those in the test results.

  • PDF