• Title/Summary/Keyword: Initial flow

Search Result 1,847, Processing Time 0.028 seconds

Optimization of Gate Location for Melt Flow Balancing in Injection Mold Cavity By Using Recursive Design Area Reduction Method (설계영역 반복축소법에 의한 사출금형의 수지 유동균형을 위한 게이트 위치 최적화)

  • Park, Jong-Cheon;Lee, Gyu-Seok;Choi, Seong-Il;Kang, Jin-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.4
    • /
    • pp.114-122
    • /
    • 2013
  • This study introduces an optimization methodology for the determination of gate location that ensures the melt flow balance within a part cavity of injection mold. A new sequential direct-search scheme based on the recursive reduction of the designer-specified gate design area is developed, and it is integrated with a commercial flow simulation tool for optimization. To quantify the level of melt flow balance, we employ the maximum difference among the fill times for the melt fronts to reach the boundary elements of part cavity as objective function. The proposed methodology is successfully applied in the case study of melt flow balancing in molding of a bar code scanner model. The result shows that the melt flow balance at the optimized gate positions is significantly improved from that for the initial gate position.

An active back-flow flap for a helicopter rotor blade

  • Opitz, Steffen;Kaufmann, Kurt;Gardner, Anthony
    • Advances in aircraft and spacecraft science
    • /
    • v.1 no.1
    • /
    • pp.69-91
    • /
    • 2014
  • Numerical investigations are presented, which show that a back-flow flap can improve the dynamic stall characteristics of oscillating airfoils. The flap was able to weaken the stall vortex and therefore to reduce the peak in the pitching moment. This paper gives a brief insight into the method of function of a back-flow flap. Initial wind tunnel experiments were performed to define the structural requirements for a detailed experimental wind tunnel characterization. A structural integration concept and two different actuation mechanisms of a back-flow flap for a helicopter rotor blade are presented. First a piezoelectric actuation system was investigated, but the analytical model to estimate the performance showed that the displacement generated is too low to enable reliable operation. The seond actuation mechanism is based on magnetic forces to generate an impulse that initiates the opening of the flap. A concept based on two permanent magnets is further detailed and characterized, and this mechanism is shown to generate sufficient impulse for reliable operation in the wind tunnel.

A Study on the Characteristics of Two-Step-Flow-Control Fluidic Device (2단 유량제어 Fluidic Device의 특성에 관한 연구)

  • Cho, Bong-Hyun;Bae, Yoon-Yeong;Park, Jong-Kyun;Yoo, Seong-Yeon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.3 s.12
    • /
    • pp.53-61
    • /
    • 2001
  • Vortex type Fluidic Device(FD) which is installed at the bottom of Safety Injection Tank(SIT) controls the discharge flow rate from the tank. In case of loss of coolant accident the injection water flows into primary system in two steps; initial high flow rate for certain period of time and subsequent low flow rate. By two-step control of the discharge flow rate, FD can ensure the effective use of water in the tank. A small-scale FD has been tested to obtain a required flow characteristics maintaining full pressure and height of prototype, which are the major contributing parameters. Through the testing of many different arrangements of internal geometry of FD, most appropriate one was selected and its performance data was obtained. As characteristics of FD, time dependent Euler number, flow rate and pressure are presented and discussed. Also a method to predict the full size FD is presented.

  • PDF

Pyrolysis Reaction for the Treatment of Hazardous Halogenated Hydrocarbon Waste (유해 할로겐화 탄화수소 폐기물 처리를 위한 열분해 반응)

  • 조완근
    • Journal of Environmental Science International
    • /
    • v.6 no.4
    • /
    • pp.399-407
    • /
    • 1997
  • The pyrolysis reactions of atomic hydrogen with chloroform were studied In a 4 cm 1.6. tubular flow reactor with low flow velocity 1518 cm/sec and a 2.6 cm 1.4. tubular flow reactor with high flow velocity (1227 cm/sec). The hydrogen atom concentration was measured by chemiluminescence titration with nitrogen dioxide, and the chloroform concentrations were determined using a gas chromatography. The chloroform conversion efficiency depended on both the chloroform flow rate and linear flow velocity, but 416 not depend on the flow rate of hydrogen atom. A computer model was employed to estimate a rate constant for the initial reaction of atomic hydrogen with chloroform. The model consisted of a scheme for chloroform-hydrogen atom reaction, Runge-Kutta 4th-order method for Integration of first-order differential equations describing the time dependence of the concentrations of various chemical species, and Rosenbrock method for optimization to match model and experimental results. The scheme for chloroform-hydrogen atom reaction Included 22 elementary reactions. The rate constant estimated using the data obtained from the 2.6 cm 1.4. reactor was to be 8.1 $\times$ $10^{-14}$ $cm^3$/molecule-sec and 3.8 $\times$ $10^{-15}$ cms/molecule-sec, and the deviations of computer model from experimental results were 9% and 12% , for the each reaction time of 0.028 sec and 0.072 sec, respectively.

  • PDF

Performance improvement of countercurrent-flow membrane gas absorption in a hollow fiber gas-liquid membrane contactor

  • Ho, Chii-Dong;Sung, Yun-Jen;Chen, Wei-Ting;Tsai, Feng-Chi
    • Membrane and Water Treatment
    • /
    • v.8 no.1
    • /
    • pp.35-50
    • /
    • 2017
  • The theoretical membrane gas absorption module treatments in a hollow fiber gas-liquid membrane contactor using Happel's free surface model were obtained under countercurrent-flow operations. The analytical solutions were obtained using the separated variable method with an orthogonal expansion technique extended in power series. The $CO_2$ concentration in the liquid absorbent, total absorption rate and absorption efficiency were calculated theoretically and experimentally with the liquid absorbent flow rate, gas feed flow rate and initial $CO_2$ concentration in the gas feed as parameters. The improvements in device performance under countercurrent-flow operations to increase the absorption efficiency in a carbon dioxide and nitrogen gas feed mixture using a pure water liquid absorbent were achieved and compared with those in the concurrent-flow operation. Both good qualitative and quantitative agreements were achieved between the experimental results and theoretical predictions for countercurrent flow in a hollow fiber gas-liquid membrane contactor with accuracy of $6.62{\times}10^{-2}{\leq}E{\leq}8.98{\times}10^{-2}$.

Flow Experience through PLC Practice (PLC실습을 통한 몰입경험)

  • Huh, Jun-Young
    • Journal of Practical Engineering Education
    • /
    • v.6 no.1
    • /
    • pp.43-49
    • /
    • 2014
  • It is known that the ability and habit to "flow" could be one of the important indices to evaluate one's life. And the flow experience of university students who are in the important time transferring from the adolescence to the initial adult period will give an important effect firstly to study one's major and map out one's career path, finally to spread out the high quality life. This study investigated the university students who are in School of Mechatronic Engineering to experience the flow in the learning of PLC (Programmable Logic Controller) practice. For this, the flow condition was arranged. And in order to experience the flow in the learning of PLC, lecture plan was established, studying environment was changed and level of difficulty was controlled. Then the implications of the flow were explored by a 5-point Likert scale survey performed to 90 students.

Ammonia Emissions from Composting Hog Manure Amended with Sawdust under Continuous and Intermittent Aeration (돈분과 톱밥혼합물의 연속 및 간헐 통기 퇴비화에서 암모니아 휘산)

  • 홍지형
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.4
    • /
    • pp.113-119
    • /
    • 2001
  • Ammonia emissions during composting of hog manure mixed with sawdust were studied in four runs comprising a total of 22 pilot-scale reactor vessels. These four runs extended previous work and both verified and extended the previous conclusions. The pilot-scale vessels were 205 L insulated stainless steel drums that were aerated either continuously (high/low thermostatically controlled fans) or intermittently (5 min high fan 55 min off). Temperature ammonia emissions air flow rates carbon dioxide production and oxygen utilization moisture and dry matter reduction initial and final chemical compositions were measured. Ammonia emissions from the intermittently aerated vessels were only about 50% as great as those from the continuously aerated ones but this was found to be a result more related to total air flow than to aeration technique. All of the data for total result more related to total air flow were fitted with a linear regression line y=0.139x+29.835 where y is ammonia expressed as g of N and x is air flow in kg with $R^2$=0.6808. this general trend indicates that about 50% reduction in ammonia emissions can be achieved with 75% reduction in air flow. For the aeration techniques used the minimum oxygen level in te exhaust gas from the vessels was 5% and this is probably a resonable lower limit constraining air flow reduction. However within this constraint lower air flow now appears to be a technique that can reduce odorous ammonia emissions.

  • PDF

Design and analysis of RIF scheme to improve the CFD efficiency of rod-type PWR core

  • Chen, Guangliang;Qian, Hao;Li, Lei;Yu, Yang;Zhang, Zhijian;Tian, Zhaofei;Li, Xiaochang
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3171-3181
    • /
    • 2021
  • This research serves to advance the development of engineering computational fluid dynamics (CFD) computing efficiency for the analysis of pressurized water reactor (PWR) core using rod-type fuel assemblies with mixing vanes (one kind of typical PWR core). In this research, a CFD scheme based on the reconstruction of the initial fine flow field (RIF CFD scheme) is proposed and analyzed. The RIF scheme is based on the quantitative regulation of flow velocities in the rod-type PWR core and the principle that the CFD computing efficiency can be improved greatly by a perfect initialization. In this paper, it is discovered that the RIF scheme can significantly improve the computing efficiency of the CFD computation for the rod-type PWR core. Furthermore, the RIF scheme also can reduce the computing resources needed for effective data storage of the large fluid domain in a rod-type PWR core. Moreover, a flow-ranking RIF CFD scheme is also designed based on the ranking of the flow rate, which enhances the utilization of the flow field with a closed flow rate to reconstruct the fine flow field. The flow-ranking RIF CFD scheme also proved to be very effective in improving the CFD efficiency for the rod-type PWR core.

A Development of Auto-Calibration for Initial Soil Condition in K-DRUM Model (K-DRUM 개선을 위한 초기토양함수 자동보정기법 개발)

  • Park, Jin-Hyeog;Hur, Young-Teck
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.2
    • /
    • pp.71-79
    • /
    • 2009
  • In this study, a distributed rainfall-runoff model, K-DRUM, based on physical kinematic wave was developed to simulate temporal and spatial distribution of flood discharge considering grid rainfall and grid based GIS hydrological parameters. The developed model can simulate temporal and spatial distribution of surface flow and sub-surface flow during flood period, and input parameters of ASCII format as pre-process can be extracted using ArcView. Output results of ASCII format as post-process can be created to express distribution of discharge in the watershed using GIS and express discharge as animation using TecPlot. an auto calibration method for initial soil moisture conditions that have an effect on discharge in the physics based K-DRUM was additionally developed. The baseflow for Namgang Dam Watershed was analysed to review the applicability of the developed auto calibration method. The accuracy of discharge analysis for application of the method was evaluated using RMSE and NRMSE. Problems in running time and inaccuracy setting using the existing trial and error method were solved by applying an auto calibration method in setting initial soil moisture conditions of K-DRUM.

  • PDF

Removal Properties of NOx by Hybrid Anion Exchanger (복합 음이온교환 수지를 이용한 NOx 제거 특성)

  • Song, Sang-Hun;Lee, Hyung-Keun;Park, Bo-Ryeung;Hwang, Eui-Hwan;Lee, Bum-Jae;Hwang, Taek-Sung
    • Applied Chemistry for Engineering
    • /
    • v.17 no.6
    • /
    • pp.653-657
    • /
    • 2006
  • The adsorption properties for $NO_{2}$ by hybrid ion exchange fiber with resins were investigated. The adsorption of $NO_{2}$ was increased with increasing of adsorption time and the initial concentration. At the initial $NO_{2}$ concentration of 900 ppm, approximately 40% of initial $NO_{2}$ was adsorbed around 20 min. And the adsorption of $NO_{2}$ was decreased with increasing of flow rate from 20 to 40 L/min. The maximum adsorbed amount of initial $NO_{2}$ was 45% at the flow rate of 10 L/min. The amount of adsorption was increased with increasing the water content.