• 제목/요약/키워드: Initial Response System

검색결과 478건 처리시간 0.033초

밀폐형 지중열교환기 설계를 위한 지중 유효열전도도 데이터베이스 구축 (Construction of Ground Effective Thermal Conductivity Database for Design of Closed-Loop Ground Heat Exchangers)

  • 최재호;손병후;임효재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.776-781
    • /
    • 2008
  • A ground heat exchanger in a GSHP system is an important unit that determines the thermal performance of a system and its initial cost. The Size and performance of this heat exchanger is highly dependent on the thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This paper is part of a research project aiming at constructing a database of these site-specific properties, especially ground effective thermal conductivity. The objective was to develop and evaluation method, and to provide this knowledge to design engineers. To achieve these goals, thermal response tests were conducted using a testing device at nearly 150 locations in Korea. The in-situ thermal response is the temperature development over time when a known heating load imposed, e.g. by circulating a heat carrier fluid through the test exchangers. The line-source model was then applied to the response test data because of its simplicity. From the data analysis, the range of ground effective thermal conductivity at various sites is $1.5{\sim}4.0\;W$/mK. The results also show that the ground effective thermal conductivity varies with grouting materials as well as regional geological conditions and groundwater flow.

  • PDF

Housing Policy Capacity and Indonesian Response to the COVID-19 Pandemic

  • SURURI, Ahmad
    • 웰빙융합연구
    • /
    • 제5권4호
    • /
    • pp.11-17
    • /
    • 2022
  • Purpose: This study discusses how Indonesia's response to the Corona Virus Disease-19 pandemic based on the perspective of housing policy capacity which consists of resources, organizations, and networks, politics, systems, and finance. Research design, data and methodology: This study used a qualitative method through a literature review. Data collection techniques were carried out by searching various sources and literature related to housing capacity theory and various data on Indonesia's response to the Covid 19 pandemic. Based on a literature review, this study adapted and modified the five components of capacity, namely resource capacity, organizational and network capacity, political capacity, system capacity and financial capacity in Indonesia in responding to the Covid-19 pandemic. Data analysis used analytical themes which consist of understanding the data, generating initial codes, looking for themes, reviewing themes, defining and naming themes, producing of manuscripts. Results: The results show that the weakness of the system capacity greatly affects Indonesia's housing policy capacity in responding to the Covid-19 pandemic and on the other hand the five housing capacities are an integrated process within the housing policy framework in Indonesia, especially to overcome the Covid-19 pandemic. Conclusions: The findings of this study are the importance of building a system capacity that is directly integrated with housing policy and the strengthening of the resources capacity, organizations, and networks, politics, and finance in the context of Indonesia's housing policy, especially in dealing with the Covid-19 pandemic situation.

재난상황 시 예비군 긴급대응부대 창설 및 운용방안에 관한 연구 (A Study on the Establish and Operating Plan of Reserve Components Emergency Response Forces)

  • Seo, SeungBae
    • 한국재난정보학회 논문집
    • /
    • 제14권1호
    • /
    • pp.9-16
    • /
    • 2018
  • 재난상황하에서는 신속한 지역단위 재난복구를 전문적으로 담당하는 인력이 필요하다. 그러나, 현재의 재난대응체계에서는 대민지원, 자원봉사 등 수준에서 재난복구를 시행하고 있으므로 전문성 부족으로 인한 초기대응 및 재난복구 지연, 재난 지속시 대응 미흡 등 다양한 문제점이 발생하고 있다. 그러므로, 재난상황시 지자체단위 초기 대응능력 구비와 신속히 재난복구를 할 수 있는 전문성을 가진 부대의 창설이 필요하다. 따라서, 본 연구에서는 재난상황하 긴급 재난복구를 통한 지역안정과 재해 주민구호, 재난이전으로의 신속한 전환을 위한 예비군 긴급대응부대를 창설과 운용방안 수준의 방향성을 제시하였다.

Establishing optimal gap size for precast beam bridges with a buffer-gap-elastomeric bearings system

  • Farag, Mousa M.N.;Mehanny, Sameh S.F.;Bakhoum, Mourad M.
    • Earthquakes and Structures
    • /
    • 제9권1호
    • /
    • pp.195-219
    • /
    • 2015
  • A partial (hybrid) seismic isolation scheme for precast girder bridges in the form of a "buffer-gap-elastomeric bearings" system has been endorsed in the literature as an efficient seismic design system. However, no guides exist to detail an optimal gap size for different configurations. A numerical study is established herein for different scenarios according to Euro code seismic requirements in order to develop guidelines for the selection of optimal buffer-gap arrangements for various design cases. Various schemes are hence designed for ductile and limited ductility behavior of the bridge piers for different seismic demand levels. Seven real ground records are selected to perform incremental dynamic analysis of the bridges up to failure. Bridges with typical short and high piers are studied; and different values of initial gaps at piers are also investigated varying from a zero gap (i.e., fully locked) condition up to an initial gap at piers that is three quarters the gap left at abutments. Among the main conclusions is that the as-built initial gaps at piers (and especially large gap sizes that are ${\geq}1/2$ as-built gaps at abutments) do not practically reduce the seismic design demand and do not affect the reserve capacity of the bridge against failure for bridges featuring long piers, especially when these bridges are designed a priori for ductile behavior. To the contrary, the "buffer-gap-elastomeric bearings" system is more effective for the bridge schemes with short piers having a large difference between the stiffness of the bearings and that of their supporting (much stiffer) squat piers, particularly for designs with limited ductility. Such effectiveness is even amplified for the case of larger initial as-built gap sizes at piers.

Innate Immune Response of NNV Infection in Fish and Its Disease Prevention

  • Lu, Ming-Wei;Wu, Jen-Leih
    • 한국해양바이오학회지
    • /
    • 제2권3호
    • /
    • pp.127-132
    • /
    • 2007
  • The innate immune response which is seen as the initial defense mechanism induced upon foreign invasion has been well documented in higher vertebrates. This has also been observed in fish infected with NNV. However, the fish immune system based on fully established genome project has not been fully elucidated. Therefore, in this review, we hope to correlate NNV infection in fish that has devastated the aquaculture industry, to its host immune system. Further, we discuss the potential preventive measures in overcoming the widespread of this neurodisease.

  • PDF

Application Studies for Active Fire Monitoring over Korea Using MODIS Direct Broadcast Data

  • Song J.H.;Kim Y.S.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.410-414
    • /
    • 2004
  • The MODIS Land Rapid Response System (RRS) has been developed to provide rapid access to MODIS data globally, with initial emphasis on 250 m color composite imagery and active fire data. Fire detection is based on a contextual algorithm that exploits the strong emission of mid-infrared radiation from fires. This algorithm examines each pixel of the MODIS swath, and ultimately assigns to each one of the following classes: missing data, cloud, water, non-fire, fire, or unknown. In this paper, we introduce the MODIS Rapid Response System established at the Korea Aerospace Research Institute (KARI) and present some application results for Korea using the direct broadcast data acquired at KARI ground station.

  • PDF

케이블돔 구조물의 안정화 이행과정 및 구조적 거동특성에 관한 연구 (A Study on the Stabilizing Process and Structural Characteristics of Cable-Dome Structure)

  • 한상을;이경수;이주선;황보석
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.260-267
    • /
    • 1999
  • In this paper, We propose the initial shape finding and dynamic analysis of cable dome structure are presented. Cable dome that is consist of three component such as cable, strut and fabric membrane have complex structural characteristics. Main structural system of cable dome is cable-strut tensegric system, and fabric membrane element Is conceived as cladding roof material. One of the important problem of cable dome is shape finding of those subjected to cable and membrane forces, which stabilize the structures. And the other is structural response from external load effect such as snow and wind When cable dome are subjected to dynamic load such as wind load each structural component has many important problem because of their special structural characteristics. One problem is that geometrical nonlinearity should be considered in the dynamic analysis because large deformation is occurred from their flexible characteristic. The other problem is that wrinkling occurs occasionally because cable and membrane elements can not transmit compressive forces. So this paper describe the physical structural response of cable dome structure.

  • PDF

지중열교환기 설치 조건이 지중 유효 열전도도에 미치는 영향 (Effect of Some Parameters on Ground Effective Thermal Conductivity)

  • 최재호;임효재;공형진;손병후
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.33-38
    • /
    • 2008
  • A ground-loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. The Size and performance of this heat exchanger is highly dependent on ground thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U-tube configurations on ground effective thermal conductivity. In this study, thermal response tests were conducted using a testing device with 9-different ground-loop heat exchangers. From the experimental results, the length of ground-loop heat exchanger affects to the effective thermal conductivity. Among the various grouting materials, the bentonite-based grout with silica sand shows the largest thermal conductivity value.

  • PDF

포/포탑 구동장치의 모드 스위칭 제어기 설계 (Mode Switching Control Design for Gun/Turret Driving System)

  • 백승문;김지영;임정빈;유준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.33-37
    • /
    • 2004
  • To meet an increasing demand for high performance in gun dynamic plant, both a precise and a fast response positioning are strongly required for the gun servomechanism control. A mode switching control(MSC) system, which includes a fine stabilizing controller, fast positioning one and a switching function, is widely used to meet this requirement. Stabilization is performed through PID controller, while proximate time optimal servo(PTOS) is used for target designation. Because gun dynamic have large damping comparing to acceleration, PTOS algorithm with damping is newly derived. This paper adopts the initial value compensation method that improve the transient response after switching. Some simulation results are given to show the effectiveness of our scheme.

  • PDF

철도차량 동적 진동특성을 고려한 다목적함수 최적설계 (A Study on the Optimum Design of Multi-Object Dynamic System for the Rail Vehicle)

  • 박찬경;이광기;김기환;현승호;박춘수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.894-899
    • /
    • 2000
  • Optimization of 26 design variables selected from suspension characteristics for Korean High Speed Train (KHST) is performed according to the minimization of 58 responses which represent running safety and ride comfort for KHST and analyzed by using the each response surface model from stochastic design experiments. Sensitivity of design variables is also analyzed through the response surface model which ineffective design prameters to the performance index are screened by using stepwise regression method. The response surface models are used for optimizing design variables through simplex algorism. Values of performance index simulated by optimized design parameters are totally lower than those by initial design parameters. It shows that this method is effective for optimizing multi-design variables to multi-object function.

  • PDF