• Title/Summary/Keyword: Initial Condition

Search Result 2,981, Processing Time 0.037 seconds

A study on reduction of excess sludge in activated sludge system from a petrochemical plant using electro fenton process (전기펜톤공정을 이용한 석유화학공장 폐활성슬러지의 감량화 가능성 평가)

  • Chung, Chong Min;Kim, Kyung Il;Shim, Natalia;Park, Chul Hee;Lee, Sang Hyup
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.669-678
    • /
    • 2009
  • The reduction of excess activated sludge from petrochemical plant was investigated by the electro fenton (E-Fenton) process using electrogenerated hydroxyl radicals which lead to mineralization of activated sludge to $CO_2$, water and inorganic ions. Factors affecting the disintegration efficiency of excess activated sludge in E-Fenton process were examined in terms of five criteria: pH, $H_2O_2/Fe^{2+}$ molar ratio, current density, initial MLSS (mixed liquid suspended solids) concentration, $H_2O_2$ feeding mode. TSS total suspended solid and $TCOD_{cr}$ reduction rate increased with the increasing $H_2O_2/Fe^{2+}$ molar ratio and current density until 42 and $6.7 mA/cm^2$, respectively but further increase of $H_2O_2/Fe^{2+}$ molar ratio and current density would reduce the reduction rate. On the other hand, as expected, increasing pH and initial MLSS concentration of activated sludge decreas TSS and $TCOD_{cr}$ reduction rate. The E-Fenton process was gradually increased during first 30 minutes and then linearly proceed till 120 minutes. The optimal E-Fenton condition showed TSS reduction rate of 62~63% and $TCOD_{cr}$ (total chemical oxygen demand) reduction rate of 55~56%. Molar ratio $H_2O_2/Fe^{2+} = 42$ was determined as optimal E-Fenton condition with initial $Fe^{2+}$ dose of 5.4 mM and current density of $6.7{\sim}13.3 mA/cm^2$, initial MLSS of 7,600 mg/L and pH 2 were chosen as the most efficient E-Fenton condition.

Cosmology using SPHEREx

  • Song, Yong-Seon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.48.3-48.3
    • /
    • 2018
  • We present the methodology to probe the initial condition of the universe using SPHEREx.

  • PDF

A Study on the Optimal Initial Stress-Finding of Structures Stabilized by Cable-Tension (장력안정 구조물의 최적초기응력 탐색에 관한 연구)

  • 최옥훈;한상을;권택진
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.04a
    • /
    • pp.287-294
    • /
    • 1999
  • The tensegrity structure by prestressed cable, which may have large freedom in scale and form and therefore are received much attention from the view points of their light weight and aesthetics, is a very flexible and geometrically unstable structure because the cable material has little initial rigidity. For the stable self-equilibrated state of the usually very deformable structure, the method to find the optimal initial stress by the shape analysis is proposed in this paper. The proposed procedure is to derive the nonlinear finite element formula of cable and truss members considering geometric nonlinearity and used to modified load incremental method adding to Newton-Raphson method with the proposed condition for optimal initial stress. The result of the shape analysis for the tensegrity structure with the radius of 30m is shown the almost approximated shape to architectural shape and the changed procedure of initial stress

  • PDF

The Development of High Wind Velocity/High Drying Time Hair Dryer using Computational Fluid Dynamics Analysis Method (전산유체역학(CFD) 분석법을 이용한 High Wind Velocity/High Drying Time 헤어드라이어의 개발)

  • Park, Soo-Hong;Park, Jong-Chan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.262-267
    • /
    • 2016
  • This paper describes a design of a hair drier to improve its performance. the performance of the hair drier can be improved by increasing the wind velocity of its discharge port. the design of the hair drier is accomplished by using the CFD. the validity of design results were verified by comparison with the dry change of the hair drier. In this paper, the initial condition of the applied hair drier is as follows, the number of the blade is 9, the diameter of the suction port is 40[mm], the tip clearance is 12.5[mm], the con angle is $28.5^{\circ}$ and the fan angle is 27.5R. From design results, the enhanced condition of the hair drier can be obtained as follows, the number of the blade is 3, the diameter of the suction port is 50[mm], the tip clearance is 10.5[mm], the con angle is $21.5^{\circ}$ and the fan angle is 75R. At the enhanced condition of the hair drier, the wind velocity of the hair drier is 29[%] increase, and the dry time is 40[%] increase compare to the initial condition of the hair drier.

Range Simulation on Spin Effort of golfball (골프공 스핀효과에 따른 비거리 시뮬레이션)

  • Han, Tae-Jong;Kim, Yong-Sun;Lee, Soon-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.3
    • /
    • pp.117-131
    • /
    • 2003
  • This study simulated the range of golf ball with different projection angles using a drive swing condition. For the simulation purpose, the differential equation of dynamics was induced by using Bernoulli's principle and average back spin frequency, instant velocity, and dimple of golf ball from amateur group, professional group, and Tiger Woods were chosen as the initial condition. The study result indicated that lift coefficient($C_{lift}$) relative to drag coefficient ($C_d$), 0.3 of differential equation was applied differently in terms of back spin Sequency, and when $C_{lift}$ was 0.4 for amateur, 0.5 for professional, and 0.7 for Tiger Woods the projection ranges of ball were closely matched with initial condition. With selected $C_{lift}$ and back spin frequency of initial condition, the ranges with different projection angle was measured as 193m ($13-17^{\circ}$) for amateur, 240m ($9-13^{\circ}$), professional and 273m ($9^{\circ}$)Tiger Woods, respectively. For the range in terms of back spin frequency and projection angle, the amateur group indicated relatively high spin frequency (70 RPS) and showed the maximal range (195m) with $13^{\circ}$ of projection angle. The tendency of longer range with higher projection angle was also found under the different conditions of spin frequency in this group. The professional group showed their maximal range (245m) with conditions of 60RPS of spin frequency and $9^{\circ}$ of projection angle. Their range was decreased dramatically when the spin frequency was reduced to 40-50 RPS. For Tiger Woods, the maximal range was found with 40RPS of spin frequency and the range was decreased notably when the spin frequency was above 40RPS.

Aerobic Composting of sewage sludge Mixed Rice Hulls and Sawdusts (하수오니에 왕겨 및 톱밥을 혼합한 호기성 퇴비화)

  • 정봉수;강용태
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.28 no.3
    • /
    • pp.99-106
    • /
    • 1986
  • This study was carried out to investigate the effects of moisture content, temperature, C/N ratio and pH of the sewage sludge mixed with hulle and sawdusts for making compost under aerobic condition and to improve the defect of the structure of experimental equipment heat lose and handling method. and obtained results were as follows 1.The temperature was reached 73$^{\circ}$ C around 50 hours fermentation in the condition of 0.8 L/min. of air and 60.4% of moisture content. and favorable moisture content of initial condition ranged from 50 to 65% 2.The temperature near bottom of the batch composter was decreased due to evaporate water vapor and lose the heat produced during aeration. and it is required to be improved. 3.The temperature in the batch composter from the center to the inside wall surface was gradually decreased. the temperatures of the points located in r=9cm and the wall surface were 4$^{\circ}$ C and 6$^{\circ}$ C respectively. and therefore it is required to be insulated. 4. The maximum C02 production was obtained as 7.3% per volume in the temperature of 63$^{\circ}$C at the moisture content of 60% 5.The temperature range of active microbes growth was found to be as 20$^{\circ}$C to 40$^{\circ}$C in the case of mesophiles and 50$^{\circ}$C to 65$^{\circ}$C in the case of thermophiles due to increase and decrease C02 production. 6.C/N ratio after decomposition was 1.3 to 2.6 smaller than that of initial one due to increase the amount of nitrogen. The more C/N ratio increased. the less the reaction velocity decresed. The optimum of it as found to be 30. 7.pH values after decomposition were slightly increased than that of initial ones. The reaction velocity was decreased at acid and alkall condition. Therefore it is neseseary to neutralize the medium to improve the reaction.

  • PDF

Simultaneous degradation of nitrogenous heterocyclic compounds by catalytic wet-peroxidation process using box-behnken design

  • Gosu, Vijayalakshmi;Arora, Shivali;Subbaramaiah, Verraboina
    • Environmental Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.488-497
    • /
    • 2020
  • The present study investigates the feasibility of nitrogenous heterocyclic compounds (NHCs) (Pyridine-Quinoline) degradation by catalytic wet peroxidation (CWPO) in the presence of nanoscale zerovalent iron supported on granular activated carbon (nFe0/GAC) using statistical optimization technique. Response surface methodology (RSM) in combination with Box-Behnken design (BBD) was used to optimize the process parameters of CWPO process such as initial pH, catalyst dose, hydrogen peroxide dose, initial concentration of pyridine (Py) and quinolone (Qn) were chosen as the main variables, and total organic carbon (TOC) removal and total Fe leaching were selected as the investigated response. The optimization of process parameters by desirability function showed the ~85% of TOC removal with process condition of initial solution pH 3.5, catalyst dose of 0.55 g/L, hydrogen peroxide concentration of 0.34 mmol, initial concentration of Py 200 mg/L and initial concentration of Qn 200 mg/L. Further, for TOC removal the analysis of variance results of the RSM revealed that all parameter i.e. initial pH, catalyst dose, hydrogen peroxide dose, initial concentration of Py and initial concentration of Qn were highly significant according to the p values (p < 0.05). The quadratic model was found to be the best fit for experimental data. The present study revealed that BBD was reliable and effective for the determination of the optimum conditions for CWPO of NHCs (Py-Qn).

Normal Mode Vibrations of a Beam with a Nonlinear Boundary Condition (비선형 경계조건을 가진 보의 정규모드진동)

  • 김현기;이원경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.392-398
    • /
    • 1998
  • In order to check the validity of nonlinear normal modes of continuous, systems by means of the energy-based formulation, we consider a beam with a nonlinear boundary condition. The initial and boundary e c6nsl of a linear partial differential equation and a nonlinear boundary condition is reduced to a linear boundary value problem consisting of an 8th order ordinary differential equations and linear boundary conditions. After obtaining the asymptotic solution corresponding to each normal mode, we compare this with numerical results by the finite element method.

  • PDF

The Initial Irreversible Capacity of the First Doping/Undoping of Lithium into Carbon

  • Doh, Chil-Hoon;Kim, Hyun-Soo;Moon, Seong-In
    • Carbon letters
    • /
    • v.1 no.3_4
    • /
    • pp.148-153
    • /
    • 2001
  • The initial irreversible capacity, $Q_i$, is one of the parameters to express the material balancing of the cathode to anode. We introduced new terms, which are the initial intercalation Ah efficiency (IIE) and the initial irreversible specific capacity at the surface ($Q_{is}$), to express precisely the irreversibility of an electrode/electrolyte system. Two terms depended on kinds of active-materials and compositions of the electrode, but did not change with charging state. MPCF had the highest value of IIE and the lowest value of $Q_{is}$ in 1M $LiPE_6$/EC + DEC (1 : 1 volume ratio) electrolyte. IIE value of $LiCoO_2$ electrode was 97-98%, although the preparation condition of the material and the electrolyte were different. $Q_{is}$ value of $LiCoO_2$ was 0~1 mAh/g. MPCF-$LiCoO_2$ cell system had the lowest of the latent capacity. $Q_{is}$ value increased slightly by adding conductive material. IIE and $Q_{is}$ value varied with the electrolyte. By introducing PC to EC+DEC mixed solvent, IIE values were retained, but $Q_{is}$ increased. In case of addition of MP, IIE value increased and $Q_{is}$ value also increased a little.

  • PDF