• 제목/요약/키워드: Inhomogeneous Correction

검색결과 23건 처리시간 0.021초

비균질 수정을 사용한 타원완화모형 개발 (Development of Elliptic Relaxation Model With The Inhomogeneous Correction)

  • 전건호;최영돈;신종근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.815-818
    • /
    • 2002
  • The elliptic relaxation model(ERM) with the inhomogeneous correction intermediate between near wall with and far from the wall. The source of the ERM usually was appled quasi-homogeneous pressure-strain correlation in homogeneous situations. This formulation was easily applied to the linear model or non-linear pressure-strain model. It is observed that the boundary conditions of the relaxation operator dominate the homogeneous pressure-strain model in the near wall region. While looking at high-Reynolds number flows, it was found necessary to modify the effect of the relaxation operator throughout the log region by accounting for gradients of the flatness variable and turbulent length scales. These effects are kinematic blocking of the wall normal velocity fluctuation and pressure reflections from the surface. This model is wall distances and unit vectors which make the model applicable to flows boundary by a complex geometry. Inhomogeneous correction model is computed inertial and non-inertial channel flow These are compared DNS(Kim et at., Kristofffrsen & Andersson) for channel flow. The present model could be predicted well for rotating flows.

  • PDF

Lnug Volume을 모델로 한 방사선치료계획 시 불균질 조직 보정에 따른 효과 (Effect of Inhomogeneity correction for lung volume model in TPS)

  • 정세영;이상록;김영범;권영호
    • 대한방사선치료학회지
    • /
    • 제16권1호
    • /
    • pp.57-65
    • /
    • 2004
  • 서론 : 폐암환자의 방사선치료계획 시 불균질 조직 보정(inhomogeneity correction)을 평가하기 위해 폐(lung), (bone) 그리고 뼈를 고정시키기 위해 사용하는 고밀도 물질인 steel 등을 포함한 불균질 조직 보정 팬텀(inhomogeneity correction phantom, ICP)을 자체 제작하였다. 이를 이용하여 방사선치료계획시스템에서 불균질조직 보정 알고리듬에 따른 값들을 비교하고, 또한 실제 측정된 값과 비교, 분석하여 불균질 조직에 따른 선량계산 변화를 평가하고자 하였다. 대상 및 방법 : 영상획득은 전산화단층촬영영상장치(CT, Volume zoom, Germany)와 자체 제작한 불균질 조직 보정팬텀(ICP, pig's vertebra, steel(8.21 g/cm3), cork(0.23 g/cm3))을 사용하였다. 방사선치료계획시스템으로는 Marks Plan(2D)과 XiO(CMS, USA, 3D)를 사용하였고, 측정값과의 비교를 위해서는 선형가속기(CL/1800, Varian, USA)와 이온전리함을 사용하였다. 전산화단층촬영영상장치로부터 획득한 영상을 이용하여 방사선치료계획장치에서 관심점(interest point, IP)에서의 점선량(point dose)과 선량분포를 얻고, 이와 동일한 조건에서 측정을 수행한 후 비교, 분석하였다. 그리고 불균질 조직 보정 알고리듬 사용 유무에 따른 차이와 방사선치료계획장치가 가지고 있는 다양한 불균질 조직 보정 알고리듬 간의 차이도 비교하였다. 결 과 : 불균질 조직 보정 팬텀 내 관심지점에 대한 측정치와 방사선치료계획장치에서 얻은 균질과 불균질 보정된 값을 비교한 결과 폐 제1지점에서의 측정치와 불균질 보정값의 오차는 2D에서 $0.8\%$, 3D에서 $0.5\%$, 스틸 제1지점에서의 측정치와 불균질 보정값의 오차는 2D에서 $12\%$, 3D에서 $5\%$의 오차를 보이나 보정을 하지 않은 값과 측정치의 오차는 각각 $16\%,\;14\%$의 오차가 나는 것을 알 수 있었다. 또한 2D에서 보다는 3D에서의 값들이 오차가 적은 것으로 나타났다. 결 론 : 방사선치료계획 시 조직 내 밀도에 따른 보정이 반드시 이루어져야 하며 보다 정확한 치료계획을 위해서는 2차원 방사선치료계획용 시스템보다는 3차원 방사선치료계획용 시스템을 사용하는 것이 정확한 보정이 가능한 것을 알 수 있었다. 그리고 불균질 조직 보정 알고리듬 간에도 차이가 있어 실제 측정을 통해 가장 적합한 불균질 조직 보정 알고리듬을 선택하는 것이 필수적이라 할 수 있다. 향후 열형광선량계와 필름 선량계를 통한 비교, 분석이 추가적으로 수행되어야 할 것으로 사료된다.

  • PDF

Green's function coupled with perturbation approach to dynamic analysis of inhomogeneous beams with eigenfrequency and rotational effect's investigations

  • Hamza Hameed;Sadia Munir;F.D. Zaman
    • Structural Monitoring and Maintenance
    • /
    • 제11권1호
    • /
    • pp.19-40
    • /
    • 2024
  • The elastic theory of beams is fundamental in engineering of design and structure. In this study, we construct Green's function for inhomogeneous fourth-order differential operators subjected to associated constraints that arises in dealing with dynamic problems in the Rayleigh beam. We obtain solutions for homogeneous and completely inhomogeneous beam problems using Green's function. This enables us to consider rotational influences in determining the eigenfrequency of beam vibrations. Additionally, we investigate the dynamic vibration model of inhomogeneous beams incorporating rotational effects. The eigenvalues of Rayleigh beams, including first-order correction terms, are also computed and displayed in tabular forms.

CT 영상을 이용한 불균질 조직의 선량보정 평가 (Evaluation of Corrected Dose with Inhomogeneous Tissue by using CT Image)

  • 김가중
    • 대한방사선치료학회지
    • /
    • 제18권2호
    • /
    • pp.75-80
    • /
    • 2006
  • 목 적: 방사선치료에 있어 종양조직이나 정상조직의 정확한 선량계산은 치료의 성패를 좌우하는 가장 큰 요인이다. 이로 인해 방사선치료계획은 컴퓨터 단층 영상의 재구성을 통한 불균질 조직에 선흡수계수를 밀도로 변환하여 CT 번호에 의한 선량 보정이 유효하게 이루어지고 있다. 대상 및 방법: 이에 본 연구는 불균질 조직등가 팬톰을 제작하여 현재 사용 중인 방사선 치료 계획시스템을 이용한 CT 번호의 측정과 질량밀도를 계산하여 물을 기준으로 상대값을 구하였다. 또한 실제 방사선 조사 시 측정된 선량(nC)과 CT영상을 이용한 치료계획 시 선량(PDD)을 상대적으로 비교함으로써 실제 CT 번호를 이용한 불균질 조직의 보정에 대한 유용성과 정확성을 평가하고자 한다. 결 과: 측정결과 CT 번호를 이용하여 계산된 조직등가물질의 질량밀도와 실제 질량밀도는 $0.005{\sim}0.069g/cm^3$의 차이를 보였으며, 방사선 치료계획 시 심부선량(PDD)과 방사선 치료 장치로 조사하여 측정된 선량의 상대오차는 $-2.8{\sim}+1.06%$로 3% 이내의 유효범위이내의 결과를 얻었다. 결 론: 본 실험은 CT 영상을 이용한 불균질 조직의 보정에 대한 유용성을 확인할 수 있었고, 방사선 치료 계획 장치의 정도 관리(Quality Assurance; QA)의 기본 틀을 제공할 수 있을 것으로 사료된다.

  • PDF

A Study on the Land Cover Characteristics in Korea : Application of Hybrid Classifier and Topographic Normalization

  • Jeon, Seong-Woo;Jung, Hui-Cheul;Chung, Sung-Moon;Lee, Sang-Ik
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.271-280
    • /
    • 1999
  • The topographical effect resulted from rugged terrains and inhomogeneous spectral characteristics due to the complexly mixed land cover condition of Korea substantially lower the remotely sensed land cover classification accuracy In this study, a topographic correction method using digital elevation model to alleviate the topographic effects. To deal with inhomogeneous spectral characteristic, a hybrid classifier with inclusion of prior probabilities was introduced. This investigation concluded that the topographical normalization and hybrid classification with prior probabilities are effective on rugged landscape. The overall and average classification accuracies were improved by 0.92% and 1.016% respectively. The most substantial and noticeable accuracy improvement was observed in forest areas.

  • PDF

Contrast-enhanced Bias-corrected Distance-regularized Level Set Method Applied to Hippocampus Segmentation

  • Selma, Tisa;Madusanka, Nuwan;Kim, Tae-Hyung;Kim, Young-Hoon;Mun, Chi-Woong;Choi, Heung-Kook
    • 한국멀티미디어학회논문지
    • /
    • 제19권8호
    • /
    • pp.1236-1247
    • /
    • 2016
  • Recently, the level set has become a popular method in many research fields. The main reason is that it can be modified into many variants. One such case is our proposed method. We describe a contrast-enhancement method to segment the hippocampal region from the background. However, the hippocampus region has quite similar intensities to the neighboring pixel intensities. In addition, to handle the inhomogeneous intensities of the hippocampus, we used a bias correction before hippocampal segmentation. Thus, we developed a contrast-enhanced bias-corrected distance-regularized level set (CBDLS) to segment the hippocampus in magnetic resonance imaging (MRI). It shows better performance than the distance-regularized level set evolution (DLS) and bias-corrected distance-regularized level set (BDLS) methods in 33 MRI images of one normal patient. Segmentation after contrast enhancement and bias correction can be done more accurately than segmentation while not using a bias-correction method and without contrast enhancement.

Fourier 변환을 이용한 불균일 굴절률 Rugate 필터의 설계 (Design of Rugate Filters of Inhomogeneous Refractive Index Using the Fourier transform)

  • 조현주;이종오;황보창권
    • 한국광학회지
    • /
    • 제6권3호
    • /
    • pp.245-256
    • /
    • 1995
  • Fourier 면환을 이용하여 불균일 굴절률 박막의 rugate 필터를 설계하였으며 rugate 필터의 반사율, 대역폭, 광학 두께, Q 함수 등을 변화시키며 Fourier 변환의 여러 가지 특성을 조사하였다. 주어진 단선 및 이중 rugate 필터의 과녁 스펙트럼에 불균일 굴절률 박막의 스펙트럼을 맞추기 위하여 merit 함수를 사용하였으며 merit 값이 최소가 되도록 Q 함수를 반복계산하여 수정하였다. Sossi, Bovard, Fabricius가 각각 유도한 세 종류의 Q함수를 반복계산 횟수, merit 함수의 값, 최적 광학두께 등의 관점에서 비교하였다. 반사율이 높은 rugate 필터 설계에는 반복계산 수정 후 반사율이 과녁스펙트럼에 가까운 Bovard와 Fabricius의 Q함수가 적당하며, 광학 두께는 최소 광학두께만 넘으면 반복계산 수정과정을 이용하여 과녁반사율을 맞출 수 있으므로 반사대역폭이 허용하는 광학두께로 결정하면 될 것이다.

  • PDF

Destructive testing of adhesively bonded joints under static tensile loading

  • Ochsner, A.;Gegner, J.
    • 접착 및 계면
    • /
    • 제5권2호
    • /
    • pp.22-36
    • /
    • 2004
  • Several in-situ testing methods of adhesively bonded joints under static short-time tensile loading are critically analyzed in terms of experimental procedure and data evaluation. Due to its rather homogeneous stress state across the glue line, the tensile-shear test with thick single-lap specimens, according to ISO 11003-2, has become the most important test process for the determination of realistic materials parameters. This basic method, which was improved in both, the experimental part by stepped adherends and easily attachable extensometers and the evaluation procedure by numeric substrate deformation correction and test simulation based on the finite element method (FEM), is therefore demonstrated by application to several kinds of adhesives and metallic adherends. Multi-axial load decreases the strength of a joint. This effect, which is illustrated by an experimental comparison, impedes the derivation of realistic mechanical characteristics from measured force-displacement curves. It is shown by numeric modeling that tensile-shear tests with thin plate substrates according to ISO 4587, which are widely used for quick industrial quality assurance, reveal an inhomogeneous stress state, especially because of relatively large adherend deformation. Complete experimental determination of the elastic properties of bonded joints requires independent measurement of at least two characteristics. As the thick-adherend tensile-shear test directly yields the shear modulus, the tensile butt-joint test according to ISO 6922 represents the most obvious complement of the test programme. Thus, validity of analytical correction formulae proposed in literature for the derivation of realistic materials characteristics is verified by numeric simulation. Moreover, the influence of the substrate deformation is examined and a FEM correction method introduced.

  • PDF

Tropospheric Anomaly Detection in Multi-Reference Stations Environment during Localized Atmospheric Conditions-(2) : Analytic Results of Anomaly Detection Algorithm

  • Yoo, Yun-Ja
    • 한국항해항만학회지
    • /
    • 제40권5호
    • /
    • pp.271-278
    • /
    • 2016
  • Localized atmospheric conditions between multi-reference stations can bring the tropospheric delay irregularity that becomes an error terms affecting positioning accuracy in network RTK environment. Imbalanced network error can affect the network solutions and it can corrupt the entire network solution and degrade the correction accuracy. If an anomaly could be detected before the correction message was generated, it is possible to eliminate the anomalous satellite that can cause degradation of the network solution during the tropospheric delay anomaly. An atmospheric grid that consists of four meteorological stations was used to detect an inhomogeneous weather conditions and tropospheric anomaly applied AWSs (automatic weather stations) meteorological data. The threshold of anomaly detection algorithm was determined based on the statistical weather data of AWSs for 5 years in an atmospheric grid. From the analytic results of anomaly detection algorithm it showed that the proposed algorithm can detect an anomalous satellite with an anomaly flag generation caused tropospheric delay anomaly during localized atmospheric conditions between stations. It was shown that the different precipitation condition between stations is the main factor affecting tropospheric anomalies.

HOMOGENEOUS SOLUTION FOR SW LACERTAE

  • Kim, Kyung-Joo;Kang, Young-Woon
    • Journal of Astronomy and Space Sciences
    • /
    • 제13권1호
    • /
    • pp.19-31
    • /
    • 1996
  • We have analyzed collected photoelectric light curves for light variations of SW Lac. The method of Fourier analysis was adopted to quantify the light variation from season to season. We found the linear relation between the Fourier coefficient, B1 and the magnitude difference between two maxima. The total light of the system has been decreased as much as 0m.04 during approxiamately 20 years time interval. Photoelectric parameters including spot parameters for all light curves were obtained by the method of the Wilson and Devinney differential correction in order to secure the variations of parameters from season to season. SW Lac, not like RS CVn type stars, required to adjust all parameters as well as spot parameters for a reasonable fit to the observations of each epoch. A surface temperature of cooler star is one of the most sensitive parameters to affect a shape of light curve of SW Lac. We conclude that the shape of light curve of SW Lac varies even during one season as well as season to season. The light curve is mainly caused by inhomogeneous surface temperature due to strong chromospheric activity of the system.

  • PDF