• Title/Summary/Keyword: Infrared spectra

Search Result 855, Processing Time 0.022 seconds

A NEW CATALOG OF AGB STARS BASED ON INFRARED TWO-COLOR DIAGRAMS

  • Suh, Kyung-Won;Hong, Jinju
    • Journal of The Korean Astronomical Society
    • /
    • v.50 no.4
    • /
    • pp.131-138
    • /
    • 2017
  • We present a new catalog of AGB stars based on infrared two-color diagrams (2CDs) and known properties of the pulsations and spectra. We exclude some misclassified objects from previous catalogs. We identify color areas in two IR 2CDs where most O-rich and C-rich objects listed in previous catalogs of AGB stars are found. By collecting new objects in these color selection areas in the two IR 2CDs, we find candidate objects for AGB stars. By using the color selection method, we identify 3996 new objects in the O-rich areas, 1487 new objects in the C-rich areas, and 295 new objects in the overlap areas of the two 2CDs simultaneously. We have found that 470 O-rich and 9 C-rich objects are Mira variables with positive spectral identification and they are newly identified AGB stars. We present a new catalog of 3828 O-rich AGB stars and 1168 C-rich AGB stars excluding misclassified objects and adding newly identified objects.

Nondestructive Quantification of Intact Ambroxol Tablet using Near-infrared Spectroscopy (근적외분광분석법을 사용한 암브록솔 정제의 비파괴적 정량분석)

  • 임현량;우영아;김도형;김효진;강신정;최현철;최한곤
    • YAKHAK HOEJI
    • /
    • v.48 no.1
    • /
    • pp.60-64
    • /
    • 2004
  • Near-infrared (NIR) spectroscopy was used to determine rapidly and nondestructively the content of ambroxol in intact ambroxol tablets containing 30 mg (12.5% m/m nominal concentration) by collecting NIR spectra in range 1100-1750 nm. The laboratory-made samples had 10.3∼15.9% m/m nominal ambroxol concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR) with autoscaling. Model validation was performed by randomly splitting the data set into calibration and validation data set (7 samples as a calibration data set and 5 samples as a validation data set). The developed NIR method gave results comparable to the known values of tablets in a laboratorial manufacturing Process, standard error of calibration (SEC) and standard error of prediction (SEP) being 0.49% and 0.49% m/m respectively. The method showed good accuracy and repeatability NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

Matrix Infrared Spectra and DFT Computations of CH2CNH and CH2NCH Produced from CH3CN by Laser-Ablation Plume Radiation

  • Cho, Han-Gook
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.5
    • /
    • pp.1361-1365
    • /
    • 2013
  • The smallest ketenimine and hydrogen cyanide N-methylide ($CH_2CNH$ and $CH_2NCH$) are provided from the argon/acetonitrile matrix samples exposed to radiation from laser ablation of transition-metals. New infrared bands are observed in addition to better determination of the vibrational characteristics for the previously reported bands, and the $^{13}C$ substituted isotopomers ($^{13}{CH_2}^{13}CNH$ and $^{13}CH_2N^{13}CH$) are also generated. Density functional frequency calculations and the D and $^{13}C$ isotopic shifts substantiate the vibrational assignments. $CH_2CNH$ is probably produced through single-step conversion of $CH_3CN$, whereas $CH_2NCH$ through two-step conversion via 2H-azirine. Inter-conversions between these two products evidently do not occur during photolysis and annealing.

Determination of Water Content in Skin by using a FT Near Infrared Spectrometer

  • Suh Eun-Jung;Woo Young-Ah;Kim Hyo-Jin
    • Archives of Pharmacal Research
    • /
    • v.28 no.4
    • /
    • pp.458-462
    • /
    • 2005
  • The water content of skin was determined using a FT near infrared (NIR) spectrometer. NIR diffuse reflectance spectra were collected from hairless mouse, in vitro, and from human inner arm, in vivo. It was found that the variation of NIR absorbance band 1450 nm from OH vibration of water and 1940 nm from the combination involving OH stretching and OH deformation, depending on the absolute water content of separated hairless mouse skin, in vitro, using the FT NIR spectrometer. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed good correlation. For practical use of the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo on the basis of the relative water content of stratum corneum from the conventional capacitance method. The PLS model predicted human skin moisture with a standard errors of prediction (SEP) of 3.98 at 1130-1830 nm range. These studies showed the possibility of a rapid and nondestructive skin moisture measurement using FT NIR spectrometer.

Dissolution Test for Indomethacin by the Portable Near-Infrared(NIR) System

  • Kim, Do-Hyung;Lim, Hun-Rang;Chang, Soo-Hyun;Woo, Young-Ah;Kim, Hyo-Jin
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.399.3-399.3
    • /
    • 2002
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test for tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50ppm using mixture of phosphate buffer(pH 7,2) and water(1:4), The near infrared(NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2mm pathlength, Partial least-square regression (PLSR) was explored to develop calibration models over the spectral range 1100-1700nm. (omitted)

  • PDF

A New Calibration Method Based on the Recursive Linear Regression with Variables Selection

  • Park, Kwang-Su;Jun, Chi-Hyuck
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1241-1241
    • /
    • 2001
  • We propose a new calibration method, which uses the linearization method for spectral responses and the repetitive adoptions of the linearization weight matrices to construct a frature. Weight matrices are estimated through multiple linear regression (or principal component regression or partial least squares) with forward variable selection. The proposed method is applied to three data sets. The first is FTIR spectral data set for FeO content from sinter process and the second is NIR spectra from trans-alkylation process having two constituent variables. The third is NIR spectra of crude oil with three physical property variables. To see the calibration performance, we compare the new method with the PLS. It is found that the new method gives a little better performance than the PLS and the calibration result is stable in spite of the collinearity among each selected spectral responses. Furthermore, doing the repetitive adoptions of linearization matrices in the proposed methods, uninformative variables are disregarded. That is, the new methods include the effect of variables subset selection, simultaneously.

  • PDF

Application of Near Infrared Spectroscopy for Nondestructive Evaluation of Color Degree of Apple Fruit (사과 착색도의 비파괴측정을 위한 근적외분광분석법의 응용)

  • Sohn, Mi-Ryeong;Cho, Rae-Kwang
    • Food Science and Preservation
    • /
    • v.7 no.2
    • /
    • pp.155-159
    • /
    • 2000
  • Apple fruit grading is largely dependant on skin color degree. This work reports about the possibility of nondestructive assessment of apple fruit color using infrared(NIR) reflectance spectroscopy. NIR spectra of apple fruit were collected in wavelength range of 1100~2500nm using an InfraAlyzer 500C(Bran+Luebbe). Calibration as calculated by the standard analysis procedures MLR(multiple linear regression) and stepwise, was performed by allowing the IDAS software to select the best regression equations using raw spectra of sample. Color degree of apple skin was expressed as 2 factors, anthocyanin content by purification and a-value by colorimeter. A total of 90 fruits was used for the calibration set(54) and prediction set(36). For determining a-value, the calibration model composed 6 wavelengths(2076, 2120, 2276, 2488, 2072 and 1492nm) provided the highest accuracy : correlation coefficient is 0.913 and standard error of prediction is 4.94. But, the accuracy of prediction result for anthocyanin content determining was rather low(R of 0.761).

  • PDF

Studies on Photosentitive Polymers (XI). Studies on Photodegradative Reaction of Naphthoquinone-1,2-diazide-5-sulfonyl Esters (感光性 樹脂에 關한 硏究 (第11報). Naphthoquinone-1,2-diazide-5-sulfonyl Esters의 光分解反應)

  • Shim Jyong Sup;Kang Doo Whan
    • Journal of the Korean Chemical Society
    • /
    • v.19 no.4
    • /
    • pp.280-285
    • /
    • 1975
  • The degradation mechanisms of naphthoquinone-1,2-diazide-5-sulfonyl esters(PGND, BEND and PVAND) of polyglyceryl phthalate (PG), bisphenol A-epichlorohydrin (BE) and polyvinyl alcohol (PVA) were studied by infrared absorption spectra. Absorption band due to C=N=and C=O of o-quinonediazide group decreased or disappeared after sufficient exposing to light. And also, absorption band C=O of indene carboxylic acid was increased. From the results, it may be concluded that the above photosensi tive polymers were dissociated to indene carboxylic acid soluble in aqueous alkali solution. Further, the effect of sensitizers were examined by the variation of intensity in infrared absorption spectra of sensitized and unsensitized samples.

  • PDF

Crystallization Behavior of Polymers as Viewed from the Molecular Level

  • Tashiro, Kohji;Sasaki, Sono;Ueno, Yoko;Yoshioka, Akiko;Kobayashi, Masamichi
    • Macromolecular Research
    • /
    • v.8 no.3
    • /
    • pp.103-115
    • /
    • 2000
  • The structural changes viewed from the molecular level have been investigated for the isothermal crystallization phenomena of polyethylene (PE) and the solvent-induced crystallization phenomenon of syndiotactic polystyrene (sPS) glassy sample. The data, which were collected by the time-resolved measurements of Fourier-transform infrared spectra, Raman spectra, synchrotron-sourced small-angle X-ray scattering, wide-angle X-ray scattering, and so on, were combined together to extract the detailed structural information in these phase transition phenomena. In the case of PE, the isothermal crystallization from the melt to the orthorhombic form was found to occur via the conformationally-disordered trans chain form, followed by the formation of the lamellar stacking structure of regular orthorhombic-type crystals. In the case of sPS, the amorphous chains in the glassy sample were found to enhance the mobility through the interaction with the injected solvent molecules, which act as a trigger to cause the conformational ordering from the random coil to the regular T$_2$G$_2$-type helical form. The thus created short helical segments were found to grow into longer helices, which gathered together to form the crystallites, as revealed by the organized coupling of the infrared, Raman and X-ray scattering data.

  • PDF

Measuring Homopause Temperatures of Jupiter, Saturn, and Titan via Three-micron Emission Spectra of CH4

  • Kim, Sang-Joon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.48.3-49
    • /
    • 2016
  • Current high-resolution IR spectroscopy at ground-based observatories made it possible to observe $3-{\mu}m\;CH_4$ emission lines from the atmospheres of Jupiter, Saturn, and Titan through narrow atmospheric windows avoiding the counterparts of telluric $CH_4$ absorptions if proper Doppler shifts betwen Earth and these planetary objects are provided. We are also expecting low-resolution (R~300) infrared spectra of Jupiter from the upcoming observations by JUNO's infrared $2-5{\mu}m$ spectrograph during the encounter with Jupiter approximately starting from July 4, 2016. Although the spectral resolution is not enough to resolve the $3-{\mu}m$ P, Q, R branch lines of CH4, the gross envelopes of the P, Q, R branches should yield information on rotational temperatures. The rotational temperatures are useful because theycan be regarded as local temperatures, as discussed by Kim et al. (2014). Since the $3-{\mu}m\;CH_4$ emission is mostly formed at micro-bar pressure levels, the derived rotational temperatures represent the local temperatures near the hompause of Jupiter. We discuss possible sciences from the derived homopause temperatures in the auroral and non-auroral regions of Jupiter.

  • PDF