• 제목/요약/키워드: Infrared optic

검색결과 78건 처리시간 0.036초

Optimization of a fiber optic probe for non-invasive blood glucose monitoring

  • Kang, Na-Roo;Baek, Ju-Hyun;Woo, Young-Ah;Lee, Hyun-Chul;Kim, Hyo-Jin
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.407.3-408
    • /
    • 2002
  • A portable near infrared (NIR) system which was newly integrated by our lab has been used to develop a non-invasive blood glucose monitoring. The portable NIR system includes a tungsten halogen lamp, a photo diode array type-InGaAs detector, and specialized reflectance fiber optic probes. The shape of probes is composed of two parts. one for illumination into sample and the other for receiving the radiation from sample. Three kinds of probes with different distance between illumination and receiving part. such as 0.03. 0.1. and 0.5mm, were investigated for optimization. (omitted)

  • PDF

Multipoint Process Monitoring System Based on a Near Infrared Ray(NIR) Acousto-Optic Tunable Filter(AOTF)

  • You, Jang-Woo;Kim, Daesuk;Kim, Soohyun;Kong, Hong-Jin;Lee, Yunwoo;Kwak, Yoon-Keun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.105.4-105
    • /
    • 2001
  • This paper describes a newly designed multipoint process monitoring system based on a NIR acousto-optic tunable filter. The NIR multipoint process monitoring system consists of a NIR AOTF device for wavelength selection, an InGaAs array sensor, and a specially designed iin-line type of optical fiber probe. Unlike a FTS(Fourier Transform Spectrometry) or grating based monitoring system, an AOTF has no moving parts, and it can be rapidly tuned to any wavelength in its operating range within microseconds. Thus, the AOTF is advantageous in terms of faster spectral imaging capability and rigidity required for industrial monitoring environment. In the current feasibility evaluation, an enhanced optical fiber probe with 3 monitoring points was used. However, ...

  • PDF

Time-Resolved Infrared Spectroscopy of Molecular Reorientation During FLC Electro-Optic Switching

  • Jang, Won-Gun;Clark, Noel A.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.1112-1117
    • /
    • 2003
  • Polarized Fourier transform infrared (IR) absorption is used to probe molecular conformation in a ferroelectric liquid crystal (FLC) during the reorientation induced by the external field. Spectra of planar aligned cells of FLC W314 are measured as functions of IR polarizer orientation and electric field applied to the FLC. The time evolution of the dichroism of the absorbance due to biphenyl core and alkyl tail molecular vibration modes, is observed. Static IR dichroism experiments show a W314 dichroism structure in which the principal axis of dielectric tensor from molecular core vibration are tilted further from the smectic layer normal than those of the tail. This structure indicates the effective binding site in which the molecules are confined in the Sm-C phase has, on average, "zig-zag" shape and this zig-zag binding site structure is rigidly maintained while the molecular axis rotates about the layer normal during field-induced switching.

  • PDF

원거리 홍채 인식에서 효율적 조명 조사방법에 관한 연구 (Research on the efficient illumination method in iris recognition at a distance)

  • 조현수;배광혁;박강령;김재희
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.969-970
    • /
    • 2008
  • This paper proposes illumination-efficient iris image capturing method. face capture method for extraction of iris pattern with one high resolution camera needs a large scale near infrared illumination. we replace high-resolution camera with co-optic-axial combination between wide view camera and narrow view camera. because this method needs small scale illumination that illuminate only narrow camera viewing angle, we can capture iris pattern image with small scale near infrared illumination.

  • PDF

비구면렌즈 설계를 위한 칼코게나이드 Ge-Sb-Se계 구조적, 광학적 특성 연구 (Structural and Optical Characteristics of ChalcogenideGe_Sb_Se for Basic Aspheric Lens Design)

  • 고준빈;명태식
    • 한국생산제조학회지
    • /
    • 제23권2호
    • /
    • pp.133-137
    • /
    • 2014
  • The recent development of electro-optic devices and anticorrosion media has made it necessary investigate infrared optical systems with solid-solid interfaces of materials with amorphous characteristics. One of the most promising classes of materials for these purposes seems to be chalcogenide glasses, which are based on the Ge_Sb_Se system, have drawn much attention because of their use in preparing optical lenses and fibers that are transparent in the range of 3-12 um. In this study, a standard melt-quenching technique was used to prepare amorphous Ge_Sb_Sechalcogenideto be used in the design and manufacture of infrared optical products. The results of structural, optical, and surface roughness analyses of high purity Ge_Sb_Sechalcogenide glasses after various annealing processes reported.

비구면렌즈 설계를 위한 칼코게나이드 Ge-Sb-Se 광학계 및 결정화 특성 연구 (Chalcogenide Ge-Sb-Se Optical and Crystallization Characteristics for Basic a Planning Aspheric Lens)

  • 명태식;고준빈
    • 한국재료학회지
    • /
    • 제26권11호
    • /
    • pp.598-603
    • /
    • 2016
  • The recent development of electro-optic devices and anticorrosion media has led to the necessity to investigate infrared optical systems with solid-solid interfaces of materials that often have the characteristic of amorphousness. One of the most promising classes of materials for those purposes seems to be the chalcogenide glasses. Chalcogenide glasses, based on the Ge-Sb-Se system, have drawn a great deal of attention because of their use in preparing optical lenses and transparent fibers in the range of 3~12 um. In this study, amorphous Ge-Sb-Se chalcogenide for application in an infrared optical product design and manufacture was prepared by a standard melt-quenching technique. The results of the structural, optical and surface roughness analysis of high purity Ge-Sb-Se chalcogenide glasses are reported after various annealing processes.

Time Resolved Infrared Spectroscopy of Electro-optic Switching of 5CB

  • Jang, Won-Gun
    • Journal of Information Display
    • /
    • 제5권1호
    • /
    • pp.34-40
    • /
    • 2004
  • Time resolved infrared IR absorption spectroscopy is carried out to investigate the dynamics of electric field induced reorientation of the biphenyl molecular core and alkyl tail sub-fragments of the nematic liquid crystal 5CB (4-pentyl-4-cyano-biphenyl). The planar to homeotropic transition for high pre-tilt planar aligned cells, is studied for switching times ranging from 200 ${\mu}sec$ down to 80 ${\mu}sec$, the latter a factor of 1000 times faster than any previous nematic IR study. The reorientation rates of the core and tail are found to be the same to within experimental error and scale inversely with applied field squared, as expected for the balance of field and viscous torques. Thus any molecular conformation change during switching must relax on a shorter time scale. A simple model shows that no substantial differences exist between the reorientational dynamics of the tails and cores on the time scales longer than on the order of 10 ${\mu}s$.

Determination of the water content in Citrus leaves by portable near infrared (NIR) system

  • Suh, Eun-Jung;Lim, Hun-Rang;Woo, Young-Ah;Kim, Hyo-Jin
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.405.1-405.1
    • /
    • 2002
  • The amount of water for the cultivation of citrus is different based on the growing period. The water content in the leaves of citrus can be a index for watering during cultivation. The purpose of this study is to determine non-destructively the water content of Citrus leaves by using near infrared spectroscopy (NIRS). Citrus leaves were prepared from satsuma mandarin leaves (Citrus unshiu Marc. var. okitsu) ranging from 62.20 to 69.98% of water content by loss on drying, NIR reflectance spectra of Citrus leaves were acquired by using a fiber optic probe. (omitted)

  • PDF

노발리스 ExacTrac system을 이용한 척추 정위 방사선수술 방법 평가 (Assessment of the Optic-guided Patient Positioning for Spinal Stereotactic Radiosurgery Using Novalis ExacTrac System)

  • 이동준;손문준;최광영;이기택;최찬영;황금철;황충진
    • 한국의학물리학회지:의학물리
    • /
    • 제13권4호
    • /
    • pp.218-223
    • /
    • 2002
  • 두개외 병소 즉, 척추 등에 발생한 종양 혹은 혈관기형 등의 병소에 대해 침습적 수술이 불가한 경우 정위적 방사선 수술이 임상에서 시도되고 있다. 본 연구는 실험적으로 팬텀에 대해 척추 정위 방사선수술을 시행하고 결과 분석을 통하여 두개외 수술 목표점에 대한 방사선수술 위치 정확도를 평가하고자 한다. 이 실험을 위하여 팬텀을 특별히 고안하였으며 수술실에서 방사선 수술 목표점의 위치는 광학적 추적 장치를 이용하여 결정하였고 3 mm 미세다엽시준기(mMLC; mcro Multi-Leaf Collimator)를 사용하여 시술하였다. 팬텀의 목표점에 대한 방사선수술 오차는 $\pm$1 mm 이내였으며 분할방사선 수술 경우도 $\pm$1 mm 이내였다. 결과적으로 광학적 위치추적 장치를 이용한 두개외 목표점의 방사선 수술은 매우 정확하고 유용한 방법으로 판단된다.

  • PDF