• Title/Summary/Keyword: Infrared optic

Search Result 78, Processing Time 0.027 seconds

Development of a Fiber-optic Noncontact Temperature Sensor for Measuring the Temperature of Cooled Secondary Water in a Nuclear Power Plant (냉각된 원전 2차계통수의 온도측정을 위한 비접촉식 광섬유 온도센서의 개발)

  • Yoo, Wook-Jae;Lee, Bong-Soo;Park, Byung-Gi;Cho, Young-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1730-1734
    • /
    • 2010
  • Generally, a pH value of secondary water in a nuclear power plant should be estimated after sampling and cooling down. In this process, the measurement of temperature is very important because a pH value is varied according to the temperature of secondary water. In this study, a noncontact fiber-optic temperature sensor using a silver halide optical fiber is fabricated to measure the temperature of cooled secondary water. And we have measured an infrared radiation, which is transferred by a silver halide optical fiber from a heat source, using a thermopile sensor. The relationships between the temperature of a heat source and the output voltage of the fiber-optic temperature sensor according to the change of distance and angle are determined. The measurable temperature range of the fiber-optic temperature sensor is from 25 to $60^{\circ}C$. Based on the results of this study, a noncontact temperature sensor using a silver halide optical fiber can be developed for the temperature measurement of the pH sample in the secondary water system.

A Study of Test Method for Position Reporting Accuracy of Airborne Camera (항공기 탑재용 카메라 위치출력오차 측정방안 연구)

  • Song, Dae-Buem;Yoon, Yong-Eun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.646-652
    • /
    • 2013
  • PRA(Position Reporting Accuracy) for EO/IR(Electro-Optic/Infrared) airborne camera is an important factor in geo-pointing accuracy. Generally, rate table is used to measure PRA of gimbal actuated camera like EO/IR. However, it is not always possible to fix an EUT(Equipment for Under Test) to rate table due to capacity limit of the table on the size and weight of the object(EUT). Our EO/IR is too big and heavy to emplace on it. Therefore, we propose a new verification method of PRA for airborne camera and assess the validity of our proposition. In this method we use collimator, angle measuring instrument, 6 dof motion simulator, optical surface plate, leveling laser, inclinometer and poster(for alignment).

Depth-profiling of skin in the near infrared using fiber optic probes

  • Woo, Young-Ah;Ahn, Jhii-Weon;Suh, Eun-Jung;Kim, Hyo-Jin
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.235.1-235.1
    • /
    • 2002
  • In previous study, we showed the feasibility of the in vivo use of portable near infrared system for the determination of human skin moisture. In order to optimize the acquiring condition of NIR spectrum of skin. skin depth profiling was investigated changing the distance and gap size between illumination and receiving of radiation in the terminal of fiber probe. The colleted light information could be controlled depending the distance and gap of fiber optic probe. (omitted)

  • PDF

Electro-Optic Cutoff Modulator on Y-cut LiNbO$_3$ Proton-Diffused Channel Waveguides (Y-cut LiNbO$_3$ 양자확산 광도파로를 이용한 전기광학 차단형 광변조기)

  • 손영성
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.269-273
    • /
    • 1990
  • The proton conserving effect of diffusion with self-aligned SiO2-cladding is investigated by infrared transmission spectra. Based on the proton conserving effect, proton-diffused channel waveguides with self-aligned SiO2-cladding substrates. And an electro-optic cutoff modulator with self aligned electrode that utilizes a single-mode proton-diffused channel waveguide in a Y-cut XX-propagating LiNbO3 substrate is fabricated. Over 20 dB extinction has been achieved with applied voltage of 15V.

  • PDF

Target Geolocation Method Using Target Detection in Infrared Images (적외선 영상의 탐지 정보를 이용한 표적 geolocation 기법)

  • Kim, Jae-Hyup;Jeong, Jun-Ho;Seo, Jeong-Jae;Lee, Jong-Min;Moon, Young-Shik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.3
    • /
    • pp.57-67
    • /
    • 2015
  • In this paper, we proposed the geolocation method using target detection information in infrared images. Our method was applied to geolocation system of hostile targets in ground-to-ground field. The major distortion that has bad effect of geolocation was composed of optic, topography, GPS(Global Positioning System) and IMU(Inertial Measurement Unit) of reconnaissance unit. We proposed enhanced geolocation method to cope with optic and topography distortion using polynomial fitting and slant-range calculation model to overcome earth curvature problem, and the result showed that the performance of our method was good for system requirements.

Development of Near Infrared Radiation Image Board for Performace Improvement of Grain Sorter (곡물선별기의 선별력 향상을 위한 근거리적외선 영상보드 개발)

  • Lee, Chae-Wook
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.18 no.1
    • /
    • pp.25-30
    • /
    • 2017
  • Currently, most of the grain sorter uses CCD optic camera to find defective products. The aim of this paper is to use the CCD camera, and aim for improving the sorting power of the grain separator by using NIR(Near Infrared Radiation) sensor based on moisture content measurement algorithm. We intend to develop a system to develop an NFC imaging system in real time by developing an NIR imaging system and developing the grain sorter system that is considered to be defective in real time by checking the internal moisture content of the raw material in the real time.

  • PDF

CALIBRATION TRANSFER FROM REFLECTANCE TO INTERACTANCE-REFLECTANCE WITHOUT STANDARDS: USE OF MATHEMATICAL PRETREATMENTS

  • Fernandez Cabanas, Victor-M.;Varo, Garrido;Dardenne, Pierre
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1242-1242
    • /
    • 2001
  • The use of fibre optic probes for NIR quality control in the industry is becoming very important, as it provides a powerful tool to reduce sample analysis time and it facilitates the implementation of on-line analyses. However, most of the applications of fibre optics and probes have been done on suspensions, clear liquids and films, chemical and pharmaceutical products and also on fruits and animal products. Traditional applications of near infrared spectroscopy in agriculture have been developed in reflectance mode and calibration transfer could be an interesting way to reduce efforts. Classical methods for calibration transfer between different instruments involve the use of sealed reference cups, but, as fibre optic analysis does not use cups, it is necessary to develop new methods for calibration transfer without standards (Blank et al., 1996). In this paper, we have studied how the most used mathematical pretreatments (three methods of Multiplicative Scatter Correction, Standard Normal Variate, Detrending and derivatives) and their combinations applied to calibration development can contribute to reduce spectral differences between instruments. Calibration equations were obtained for three sets of cereals (barley, wheat and maize) scanned in reflectance mode and then they were validated with samples analysed in reflectance and interactance-reflectance mode (fibre optic). Preliminary results show how some combination of pretreatments reduce the differences in the predicted values, measured as standard error of differences, facilitating the use of calibrations obtained in reflectance for samples analysed by interactance-reflectance. However, the application of pretreatments is not enough to satisfy the control limits for calibration transfer suggested by Shenk et al. (1992), and it should be necessary to combine them with a specific algorithm for instruments standardization.

  • PDF

Development of Medical Infrared Imaging System (의료용 적외선 영상장치의 구현)

  • Lee, Soo-Yeol;Woo, Eung-Je;Cho, Min-Hyung;Song, Hyung-Bin
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.17-20
    • /
    • 1993
  • With proper designs of infrared optic system and two dimensional scanning mechanism, a medical infrared imaging system has been developed. The infrared imaging system can be used for two dimensional imaging of surface temperature of human body by measuring the amount of infrared lights radiating from it. It hag been experimentally proven that the degree of temperature measurement accuracy of the developed system is under $0.1^{\circ}C$ with spatial resolution of 1 mrad, image matrix size of $256{\times}240$, and imaging time of 4 seconds.

  • PDF

A Study on the Productivity Improvement of Thermal Infrared Camera an Optical Lens (열적외선 카메라용 광학계 생산성 향상에 관한 연구)

  • Kim, Sung-Yong;Hyun, Dong-Hun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.3
    • /
    • pp.285-293
    • /
    • 2009
  • Thermal infrared cameras have been conducted actively in various application areas, such as military, medical service, industries and cars. Because of their characteristic of sensing the radiant heat emitted from subjects in the range of long-wavelength($3{\sim}5{\mu}m$ or $8{\sim}12{\mu}m$), and of materializing a vision system, when general optics materials are used, they don't react to the light in the range of long-wavelength, and can't display their optic functions. Therefore, the materials with the feature of higher refractive index, reacting to the range of long-wavelength, are to be used. The kinds of materials with the characteristic of higher refractive index are limited, and their features are close to those of metals. Because of these metallic features, the existing producing method of optical systems were direct manufacturing method using grinding method or CAD/CAM, which put limit on productivity and made it difficult to properly cope with the increasing demand of markets. GASIR, a material, which can be molded easily, was selected among infrared ray optics materials in this study, and the optical system was designed with two Aspheric lenses. Because the lenses are molded in the environment of high temperature and high pressure, they require a special metallic pattern. The metallic pattern was produced with materials with ultra hardness that can stand high temperature and high pressure. As for the lens mold, GMP(Glass Molding Press) of the linear transfer method was used in order to improve the productivity of optical systems for thermal infrared cameras, which was the goal of this paper.

  • PDF

Operating Characteristic Analysis of Optic Temperature Sensor for Overheat Detection in Panel Board (분전함에서 이상발열 감지를 위한 광온도센서의 동작특성 분석)

  • Moon, Hyun-Wook;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.10
    • /
    • pp.100-106
    • /
    • 2009
  • In this study, methods of overheat detection at the coupling or wire in electrical facility are investigated, operating characteristic about the optic temperature sensor for continuous on-line temperature monitoring in diagnostics system of electrical facility is analyzed. Heating sources in the experiment for operating characteristics of optic temperature sensor use black body and hot plate, output voltage of optic temperature sensor in accordance with temperature variation is analyzed. Overheat generation due to poor contact at the circuit breaker in panel board detects using a thermocouple, infrared thermal camera and optic temperature sensor, and experiment results are analyzed. The effect of optic temperature sensor is the same that of other methods. These results expect to use basic research material for adjusting field of electrical diagnostics system using RFID type optic temperature sensor in the near future.