• Title/Summary/Keyword: Infrared block

Search Result 80, Processing Time 0.023 seconds

A study on the improvement of the thermal properties of ZnO arrester blocks (산화아연 피뢰기 소자의 열적 특성 향상을 위한 연구)

  • Kim, Dong-Seong;Lee, Su-Bong;Lee, Seung-Ju;Kim, Dong-Kyu;Yang, Soon-Man;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.335-338
    • /
    • 2009
  • In this study, in order to investigate the thermal and electrical properties of ZnO arrester block against 60[Hz] AC voltage, the changes in leakage current were measured. The temperature distribution appearing on the ZnO arrester blocks was observed using a forward looking infrared camera. In particular, the correlation between the thermal and electrical properties of a ZnO arrester block was analyzed experimentally. From this analysis, the thermal phenomena resulting from the heat generation and dissipation of the ZnO arrester block were interpreted. The degradation and thermal runaway phenomena of ZnO arrester block are closely related to the temperature limit of the ZnO arrester block. The installation of an additional metal electrode has resulted in the decrease of the leakage current due to the heat dissipation.

  • PDF

Ultrasound Thermography Technique for Detecting Micro Defects in Vehicle Engine Block (자동차 엔진블럭의 미세크랙 검출을 위한 초음파 서모그래피 기법에 관한 연구)

  • Kim, Sung Hyun;Kim, Jae Yeol;Choi, Seung Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.4
    • /
    • pp.443-446
    • /
    • 2013
  • An infrared thermography technique can be used to inspect a large area simultaneously and to detect defects such as cracks or delaminations in real time. Infrared thermography is a technique in which visual images are formed from the infrared range from subjects according to their thermal radiation. The molecules of all objects are disturbed by heat, and the molecular motion becomes more active when the temperature rises and less active when the temperature falls. In this study, the applicability and feasibility of ultrasound thermography for detecting defects in an engine block, which is a key component in the automobile industry, were verified. A nondestructive reliability test was conducted to study the defects, after which the results were analyzed.

A Prototype of Sensor Module to Control the Position of Hull Block for Tack Welding (선체 블록의 판접 위치 획득을 위한 센서 모듈 시제품 개발)

  • Jeon, Jeong-Ik;Lee, Jang-Hyun;Son, Gum-Jun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.49 no.1
    • /
    • pp.87-92
    • /
    • 2012
  • Alignment of the main plates during the tack welding is essential to block assembly since most of the curved blocks and outfitting parts are assembled on the jigs and fixtures. Tact welding of main plates is the initial process of the curved hull block assembly. Due to the heavy weight of the main plates it is difficult to locate the plate on the accurate position of the jig and fixtures before welding. The conventional masonry process requires much time and manual work in order to achieve the accurate alignment. This labour-intensive process results in relatively high errors and correction works. Due to their larger dimensions and heavier weights, these hull blocks are not ergonomically desirable and, therefore, various mechanical devices such as hydraulic balancers or hydraulic jigs are used for the plate alignment. In this study, the position-sensing scheme implemented by sensors is presented in order to align the main plates on the accurate position during the hull block assembly. Integrating the Infrared photo sensors and micro processor unit, a small scaled prototype of the position-sensing module is developed to determine the alignment of main plates.

The analysis of the Effect the Minute Quantities of Infrared Rays that Were not Filtered by IR Cut-Off Filter has on Digital Images (IR Cut-Off Filter가 차단하지 못한 미량의 적외선이 디지털화상에 미치는 영향 분석)

  • Lee, Yong-Hwan;Park, Se-Won;Hong, Jung-Eui
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.205-215
    • /
    • 2011
  • Films are sensitive to ultraviolet rays and in contrast, digital camera sensors are extremely sensitive to infrared rays due to the differences in spectral characteristics. As a result, all digital cameras that use CCD or CMOS are equipped with IR Cut-Off Filter on the overall sensor. Complete block out of infrared rays is ideal, but the actual experiment results showed that infrared rays were not being blocked out completely. Infrared permeability was also different for each camera. Therefore, this study aims to analyze the effect of the minute quantities of infrared rays, which get transmitted due to mechanical properties of IR Cut-Off Filters that are installed on digital cameras, on digital picture images. The results obtained by carrying out a comparative analysis of a UV Filter (infrared transmitting state) and a UV-IR Filter (infrared blocked out state) are as follows. It was confirmed that the minute quantities of infrared rays do affect dynamic range and resolution to some extent, despite the little or no difference in noise and color reproduction.

Comparison of blue light, visible light and infrared light transmittance difference of shading Goggles (청색광, 가시광선 및 적외선이 차광보안경에 따라 투과되는 투과율 차이 비교)

  • Jung, In-Ho;Lee, Sang-Deok;Lee, Sook-Jeong
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.65-71
    • /
    • 2020
  • Purpose: To know the transmittance of light when wearing shading goggles and to protect eyes from blue light emitted from dental scanner when using CAD/CAM works or inducing polymerization reactions of dental resin with curing unit and infrared light occurred when melting Dental precious metal and non-precious metal alloys. Methods: By measuring and comparing the average transmittances of blue light, visible light and infrared ight by using UV-Vis Spectrophotometer analysis measuring instrument, I compared 3 GREEN Color Goggles worn when casting Dental precious metal and non-precious metal alloys, and compared each of YELLOW, ORANGE Color Goggles worn when using Dental CAD/CAM scanners and Light Curing(LED) the Dental resin. Results: In blue light range, YELLOW Color Goggles are more effective than ORANGE Color Goggles. In infrared light range, No.12 Goggles are more effective than No.10 and No.11 Goggles. Conclusion: When wearing blue light shading goggles to avoid harmful blue light occurred in using dental scanner and curing light, and when wearing infrared light shading goggles to avoid harmful infrared light during casting, to avoid the Side Effects like transmittance rate of blue light and infrared light goggles becomes too high to block appropriate amount of harmful light or too low that causing lower image clarity.

FPGA implementation of high temperature feature points extraction algorithm for thermal image (열화상 이미지에 대한 고온 특징점 추출 알고리즘의 FPGA 구현)

  • Ko, Byoung-Hwan;Kim, Hi-Seok
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.578-584
    • /
    • 2018
  • Image segmentation has been presented in the various method in image interpretation and recognition, and the image is using separate the characteristics of the specific purpose. In this paper, we proposed an algorithm that separate image for feature points detected to high temperature in a Thermal infrared image. In order to improve the processing time, the proposed algorithm is implemented to FPGA Hardware Block using the Zynq-7000 Evaluation Board environment. The proposed High-Temperature Detection Algorithm and total FPGA blocks show a decrease of a processing time result from 16ms to 0.001ms, and from 50ms to 0.322ms respectively. It is also verified similar results of the PSNR to comparing software thermal testbench and hardware ones.

Study on the Growth of Monoclinic VO2 Phase Applicable for Thermochromic Ceramic Tile

  • Jung, DaeYong;Kim, Ungsoo;Cho, Wooseok
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.5
    • /
    • pp.361-365
    • /
    • 2015
  • Vanadium dioxide ($VO_2$) of monoclinic phase exhibits Metal Insulator Phase Transition (MIPT) phenomenon involving a sharp change in electrical and optical properties at $68^{\circ}C$. Solution-based process is applied to form uniform $VO_2$ coating layer on ceramic tiles. This can selectively block the near-infrared light to possibly reduce the energy loss and prevent dew condensation caused by the temperature difference. Heat treatment conditions including temperature and dwell time were examined to obtain a monoclinic $VO_2$ single phase. Both rutile and monoclinic $VO_2$ phases were observed from in the tiles post-annealed below $700^{\circ}C$. Desired monoclinic $VO_2$ single phase was grown in the tiles heat treated at $750^{\circ}C$. Nano facets of irregular size were observed in the monoclinic $VO_2$ phase involving the phase-transition. Grain growth of monoclinic $VO_2$ phase was observed as a function of dwell time at $750^{\circ}C$.

Analysis of Temperature Reduction and Reflection Spectrum of Steel Plate according to Differential Thermal Mechanism of Solar Heat Paint (태양열 차단 도료의 차열 메카니즘에 따른 강판재의 온도저감 및 반사스펙트럼 분석)

  • Mun, Dong-Hwan;Lee, Kwang-Soo;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.37-38
    • /
    • 2017
  • In Infrared rays, which are 50% of sunlight, act as heat rays to heat buildings. Solar heat paint is widely used to protect buildings from sunlight. Solar heat coatings are used to block buildings form sunlight. Solar heat paints are classified as heat-reflective paints and heat-insulating paints according to the differential thermal mechanism. In this study, we study the thermal differential mechanism by analyzing the temperature change of the coated steel plate and the solar reflection spectrum on the surface. In this experiment, exposed steel plate, heat-reflective coated steel plate, heat-insulating coated steel plate, and general paint coated steel plate were used. As a result, when the infrared rays of 780nm ~ 1400nm were irradiated, the heat reflective paint had a temperature lower by 10 degrees than other paints. Analysis of the reflection spectrum of the paint shows that the heat paint is lower in heat than other paints because it has higher reflectance of light and absorbs much of the infrared rays.

  • PDF

IR Image Processing IP Design, Implementation and Verification For SoC Design

  • Yoon, Hee-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • In this paper, We studied the possibility of SoC(System On Chip) design using infrared image processing IP(Intellectual Property). And, we studied NUC(Non Uniformity Correction), BPR(Bad Pixel Recovery), and CEM(Contrast Enhancement) processing, the infrared image processing algorithm implemented by IP. We showed the logic and timing diagram implemented through the hardware block designed based on each algorithm. Each algorithm was coded as RTL(Register Transfer Level) using Verilog HDL(Hardware Description Language), ALTERA QUARTUS synthesis, and programed in FPGA(Field Programmable Gated Array). In addition, we have verified that the image data is processed at each algorithm without any problems by integrating the infrared image processing algorithm. Particularly, using the directly manufactured electronic board, Processor, SRAM, and FLASH are interconnected and tested and the verification result is presented so that the SoC type can be realized later. The infrared image processing IP proposed and verified in this study is expected to be of high value in the future SoC semiconductor fabrication. In addition, we have laid the basis for future application in the camera SoC industry.

ASSESSMENT OF INFERIOR ALVEOLAR NERVE DAMAGE USING DIGITAL INFRARED THERMOGRAPHIC IMAGING (디지털 적외선 체열 검사를 사용한 하치조 신경 손상의 평가)

  • Lee, Ji-Yeon;Lee, Jae-Hoon;Kim, Chul-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.6
    • /
    • pp.488-496
    • /
    • 2004
  • Oral & Maxillofacial surgery can lead to complications that result in abnormal sensation or movement. Inferior alveolar nerve(IAN) injury can result in dysesthesia, paresthsia of the lower lip and chin, so patients presenting with IAN damage suffer from sensory loss. But diagnosis of the nerve injury is largely limited to the subjective statements made by the patient. Distribution of sympathetic nerves parallels the distribution of the somatosensory nerves. Loss of sensory tone causes a concomitant loss of sympathetic activity, resulting in vasodilation of the cutaneous blood vessels that demonstrates greater heat loss. Digital infrared thermographic imaging(DITI) detects infra-red radiation given off by body. DITI can detect minute difference in temperature from different parts of the body and translates the amount of heat into quantitative data. The area of different temperature correlated with pain or disease can be visualized by corresponding color. The objective of this study was to determine the efficacy of DITI in objectively assessing IAN injury. The 19 normal subjects and the 14 patients underwent DITI scan. The normal subjects received unilateral IAN block anesthesia with 2 ml of 2% lidocaine (IAN bolck group) to evaluate temporary alteration in nerve function. Patient group were patients with unilateral IAN damage (dysesthesia or paresthesia) after surgical treatment(Mn. 3rd molar Extraction, etc.). The surgical procedure performed within 6 months of test. The results were as follows. 1. No significant differences in temperature were found between left and right sides of the lower lip and chin in the control group. 2. Significant temperature differences were found between the anesthetized and non-anesthetized sides of the lower lip and chin in the IAN block group. 3. Significant temperature differences were found between the involved and uninvolved sides of the lower lip and chin areas of the experimental group. The results of the study show that DITI can be an useful and effective means of objectively assessing and visualizing IAN damage.