• Title/Summary/Keyword: Infrared analysis system

Search Result 432, Processing Time 0.029 seconds

Analysis of Lead Ions in a Waste Solution Using Infrared Photo-Diode Electrode

  • Ly, Suw-Young;Lee, Hyun-Kuy;Kwak, Kyu-Ju;Ko, Jun-Seok;Lee, Jeong-Jae;Cho, Jin-Hee;Kim, Ki-Hong;Kim, Min-Seok;Lee, So-Jung
    • Toxicological Research
    • /
    • v.24 no.3
    • /
    • pp.227-233
    • /
    • 2008
  • To detect lead ions using electrochemical voltammetric analysis, Infrared Photo-Diode Electrode(IPDE) was applied via cyclic and square wave stripping voltammetry. Lead ions were deposited at 0.5 V(versus Ag/AgCl) accumulation potential. Instrumental measurements systems were made based on a simple and compact detection system. The stripping voltammetric and cyclic voltammetric optimal parameters were searched. The results yielded a cyclic range of $40{\sim}240mgl^{-1}$ Pb(II) and a square wave stripping working range of $0.5{\sim}5.00mgl^{-1}$ Pb(II). The relative standard deviation at 2 and 4 $mgl^{-1}$ Pb(II) was 0.04% and 0.02%(n=15), respectively, using the stripping voltammetric conditions. The detection limit was found to be 0.05 $mgl^{-1}$ with a 40 sec preconcentration time. Analytical interference ions were also evaluated. The proposed method was applied to determine lead ions in various samples.

Development of Autometic Tomato Grade System with Using a Color Image Processing (칼라 영상을 이용한 토마토 자동 선별시스템의 개발)

  • 이지훈;최연호;김우현;윤경섭;권우현
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2529-2532
    • /
    • 2003
  • The quality of agricultural products is represented a degree of freshness and a special qualify that has a close relation to commercial value. To grade tomatoes, it used to nondestructive equipment of a charge-coupled device(CCD) camera and near-infrared(NIR) spectrum analysis method. The NIR spectrum analysis method is used to determine internal qualities such as a brix and an acidity. The CCD camera is used to measure external qualities like color and a size of tomatoes. This paper explaines the structure and movement of the automatic grade system and applies the algorithm for deformed tomtatoes and characteristics of tomatoes through image processing to the grade system.

  • PDF

Comparison of Three-Dimensional Dynamic Simulation with Falling Gait Analysis (헛디딤 보행특성과 3 차원 모의해석결과 비교)

  • 명성식;금영광;황성재;김한성;김영호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.359-363
    • /
    • 2004
  • Numerous studies have been performed to analyze various phenomena of human's walking, gait. In the present study, unrecognized walking and recognized walking were analyzed by three dimensional motion capture system(VICON motion system Ltd., England) and simulated by computer program. Two normal males participated in measuring the motion of unrecognized and recognized walking. Six infrared cameras and four force plates were used and sixteen reflective markers were attached to the subject to capture the motion. A musculoskeletal model was generated anatomically by using ADAMS(MSC software corp., USA) and LifeMOD(Biomechanics Research Group Inc, USA). The inverse dynamic simulation and forward dynamic simulation were also performed. The result of simulation was similar to the experimental result. This study provides the base line for dynamic simulation of the falling walking. It will be useful to simulate various another pathologic gaits for old peoples.

  • PDF

RELIABILITY ANALYSIS OF THE MSC SYSTEM

  • Kim, Young-Soo;Lee, Do-Kyoung;Lee, Chang-Ho;Woo, Sun-Hee
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.3
    • /
    • pp.217-226
    • /
    • 2003
  • MSC (Multi-Spectral Camera) is the payload of KOMPSAT-2, which is being developed for earth imaging in optical and near-infrared region. The design of the MSC is completed and its reliability has been assessed from part level to the MSC system level. The reliability was analyzed in worst case and the analysis results showed that the value complies the required value of 0.9. In this paper, a calculation method of reliability for the MSC system is described, and assessment result is presented and discussed.

Analysis of Requirements for Night Vision Imaging System (야시조명계통 요구도 분석)

  • Kwon, Jong-Kwang;Lee, Dae-Yearl;Kim, Whan-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.51-61
    • /
    • 2007
  • This paper concerns about the requirement analysis for night vision imaging system(NVIS), whose purpose is to intensify the available nighttime near infrared(IR) radiation sufficiently to be caught by the human eyes on a miniature green phosphor screen. The requirements for NVIS are NVIS radiance(NR), chromaticity, daylight legibility/readability, etc. The NR is a quantitative measure of night vision goggle (NVG) compatibility of a light source as viewed through goggles. The chromaticity is the quality of a color as determined by its purity and dominant wavelength. The daylight legibility/readability is the degree at which words are readable based on appearance and a measure of an instrument's ability to display incremental changes in its output value. In this paper, the requirements of NR, chromaticity, and daylight legibility/readability for Type I and Class B/C NVIS are analyzed. Also the rationale is shown with respect to those requirements.

Investigation of the Effects of UAV Nozzle Configurations on Aircraft Lock-on Range (무인항공기의 노즐 형상 변화가 Lock-on Range에 미치는 영향에 관한 연구)

  • Kim, Min-Jun;Kang, Dong-Woo;Myong, Rho-Shin;Kim, Won-Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.3
    • /
    • pp.204-212
    • /
    • 2015
  • The infrared lock-on range of target aircraft plays a critical role in determining the aircraft survivability. In this investigation, the effects of various UAV engine nozzle configurations on the aircraft lock-on range were theoretically analyzed. A virtual subsonic aircraft was proposed first, based on the mission requirement and the engine performance analysis, and convergent-type nozzles were then designed. After determining thermal flow field and nozzle surface temperature distribution with the CFD code, an additional analysis was conducted to predict the IR signature. Also, atmospheric transmissivity for various latitude and seasons was calculated, using the LOWTRAN code. Finally, the lock-on and lethal envelopes were calculated for different nozzle configurations, assuming the sensor threshold of the given IR guided missile. It was shown that the maximum 55.3% reduction in lock-on range is possible for deformed nozzles with the high aspect ratio.

Free Vibration Characteristics of Rectangular Plates under Uniform Thermal Loading Part II. Experimental Modal Test (균일 열부가 하중을 받는 사각판의 자유 진동특성 연구 Part II. 고유진동 실험)

  • Jeon, Byoung-Hee;Kang, Hui-Won;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.2
    • /
    • pp.106-113
    • /
    • 2011
  • This paper was conducted on experimental analysis in the free vibration analysis of rectangular plates under uniform thermal loading. Materials of three rectangular plates were aluminum, steel and stainless-steel respectively. The dimension of rectangular plates was 0.1 $\times$ 0.1 $\times$ 0.002 m. Infrared quartz lamps were used for thermal loading. The PCS(Power Control System) electric control system was applied for control and scanning vibrometer (Poly Tech) was used for acquisition of frequency response function. Applied temperature was increased from room temperature to $300^{\circ}C$ by $50^{\circ}C$. Boundary condition was free-free condition using bungee cord. Front face of rectangular plate was heated uniformly.

NIRS Analysis of Liquid and Dry Ewe Milk

  • Nunez-Sanchez, Nieves;Varo, Garrido;Serradilla-Manrique, Juan M.;Ares-Cea, Jose L.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1251-1251
    • /
    • 2001
  • The routine analysis of milk chemical components is of major importance both for the management of animals in dairy farms and for quality control in dairy industries. NIRS technology is an analytical technique which greatly simplifies this routine. One of the most critical aspects in NIRS analysis of milk is sample preparation and analysis modes which should be fast and straightforward. An important difficulty when obtaining NIR spectra of milk is the high water content (80 to 90%) of this product, since water absorbs most of the infrared radiation, and, therefore, limits the accuracy of calibrating for other constituents. To avoid this problem, the DESIR system was set up. Other ways of radiation-sample interaction adapted for liquids or semi-liquids exist, which are practically instantaneous and with limited or null necessity of sample preparation: Transmission and Folded Transmission or Transflectance. The objective of the present work is to compare the precision and accuracy of milk calibration equations in two analysis modes: Reflectance (dry milk) and Folded Transmission (liquid milk). A FOSS-NIR Systems 6500 I spectrophotometer (400-2500 nm) provided with a spinning module was used. Two NIR spectroscopic methods for milk analysis were compared: a) folded transmission: liquid milk samples in a 0.1 pathlength sample cell (ref. IH-0345) and b) reflectance: dried milk samples in glass fibre filters placed in a standard ring cell. A set of 101 milk samples was used to develop the calibration equations, for the two NIR analysis modes, to predict casein, protein, fat and dry matter contents, and 48 milk samples to predict Somatic Cell Count (SCC). The calibrations obtained for protein, fat and dry matter have an excellent quantitative prediction power, since they present $r^2$ values higher than 0.9. The $r^2$ values are slightly lower for casein and SCC (0.88 and 0.89 respectively), but they still are sufficiently high. The accuracy of casein, protein and SCC equations is not affected by the analysis modes, since their ETVC values are very similar in reflectance and folded transmission (0.19% vs 0.21%; 0.16% vs 0.19% and 55.57% vs 53.11% respectively), Lower SECV values were obtained for the prediction of fat and dry matter with the folded transmission equations (0.14% and 0.25% respectively) compared to the results with the reflectance ones (0.43% and 0.34% respectively). In terms of accuracy and speed of analytical response, NIRS analysis of liquid milk is recommended (folded transmission), since the drying procedure takes 24 hours. However, both analysis modes offer satisfactory results.

  • PDF

Performance Analysis of IR/RF-DSRC for Improved High Density ITS Service (개선된 ITS 서비스 제공을 위한 IR/RF-DSRC 성능 분석)

  • Kwag, Su-Jin;Kim, Jea-Myoung;Lee, Sang-Sun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.4
    • /
    • pp.107-117
    • /
    • 2008
  • OBE(On Board Equipment) of IR(Infrared)/RF(Radio Frequence)-DSRC(Dedicated Short Range Communication) are set up 1.25 million cars because Korea Highway Cooperation supplied in HiPass(Domestic Electronic Toll Collection System). But this DSRC system has strength and weakness of service for BIS(Bus Information System) or UTIS(Urban Traffic Information System) because BIS and UTIS are required vary high communication's performance and management. In this paper, Efficiency of IR/RF-DSRC is analyzed performance of MAC(Medium Access Control) by computer simulation for services of BIS or UTIS, so Suggested to be commensurated with medium of there service. Specially, DSRC is needed high mobility and throughput in the vary short communication range, so Analysed the transmission rate of data in each communication medium over the specific character of the MAC frame.

  • PDF

Design and Analysis of an Optical System for an Uncooled Thermal-imaging Camera Using a Hybrid Lens (Hybrid 렌즈를 이용한 비냉각 열상장비 광학계 설계 및 분석)

  • Ok, Chang-Min;Kong, Hyun-Bae;Park, Hyun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.5
    • /
    • pp.241-249
    • /
    • 2017
  • This paper presents the design and evaluation of the optical system for an uncooled thermal-imaging camera. The operating wavelength range of this system is from $7.7{\mu}m$ to $12.8{\mu}m$. Through optimization, we have obtained a LWIR (Long Wave Infrared) optical system with a focal length of 5.44 mm, which consists of four aspheric surfaces and two diffractive surfaces. The f-number of the optical system is F/1.2, and its field of view is $90^{\circ}{\times}67.5^{\circ}$. The hybrid lens was used to balance the higher-order aberrations, and its diffraction properties were evaluated by scalar diffraction theory. We calculated the polychromatic integrated diffraction efficiency, and the MTF drop generated by background noise. We have evaluated the thermal compensation of a LWIR fixed optical system, which is optically passively athermalized to maintain MTF performance in the focal depth. In conclusion, these design results are useful for an uncooled thermal-imaging camera.