• Title/Summary/Keyword: Infrared Thermographic

Search Result 146, Processing Time 0.029 seconds

Infrared Thermographic Monitoring for Failure Characterization in Railway Axle Materials (철도차량 차축 재료의 파괴특성 적외선열화상 모니터링)

  • Kim, Jeong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.116-120
    • /
    • 2010
  • The wheelset, an assembly of wheel and axle, is one of important parts in railway bogie, directly related with the running safety of railway rolling stock. In this investigation, the tensile failure behavior of railway axle materials was investigated. The tensile coupons were prepared from the actual rolling stock parts, which were operated over 20 years. The tensile testing was performed according to the KS guideline. During tensile testing, an infrared camera was employed to monitor temperature changes in specimen as well as demonstrate temperature contour in terms of infrared thermographic images. The thermographic images of tensile specimens showed comparable results with mechanical behavior of tensile materials. In this paper, the failure mode and behavior of railway axle materials were provided with the aid of infrared thermography technique.

Characteristics of Infrared Blocking, Stealth and Color Difference of Aluminum Sputtered Fabrics

  • Han, Hye Ree
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.4
    • /
    • pp.592-604
    • /
    • 2019
  • This study examines the stealth function of sputtered fabric with an infrared thermal imaging camera in terms of the thermal and infrared (IR) transmittance characteristics. Various base fabrics were selected, infrared imaging was performed, and infrared transmittance was measured. By infrared camera experiment it was found that the sample was concealed because it had a similar color to the surroundings when the aluminum layer was directed toward the outside. In addition, a comparison of the infrared thermographic image of the untreated sample and the sputtered sample in the laboratory showed that the difference in ${\Delta}E$ value ranged from 31 to 90.4 and demonstrated effective concealment. However, concealment was not observed in the case of the 3-layer (Nylon-Al-Nylon) model when a sputtered aluminum layer existed between two nylon layers. The direction of the sputtering layer did not affect the infrared transmittance in the infrared transmittance experiment. Therefore, it seems better to interpret the concealing effect in the infrared thermographic images by using thermal transfer theory rather than infrared transmittance theory. We believe that the results of this study will be applicable to developing high performance smart clothing and military uniforms.

Pilot Study on The Thermographic Change of Seven Acupoints by Digital Infrared Thermographic Imaging (적외선 체열 촬영을 이용한 중풍칠처혈 자침시 체표온도 변화에 관한 Pilot Study)

  • Lee, Yun-Kyu;Lee, Yoon-Kyoung;Seo, Bo-Myung;Yun, Jong-Seok;Kim, Kyung-Un;Choi, Sung-Hun;Lee, Kyung-Min;Lim, Seong-Chul;Jung, Tae-Young;Han, Sang-Won;Seo, Jung-Chul
    • Journal of Pharmacopuncture
    • /
    • v.8 no.3
    • /
    • pp.115-121
    • /
    • 2005
  • Objectives : This study was designed to find out the effect of seven acupoints of stroke in cerebrovascular hemiplegia patients. Methods : This study was performed on 6 patients with cerebrovascular hemiplegia (test group) and 6 health persons(control group). We measured temperature of skin surface of test and control group using digital infrared thermographic imaging(D.I.T.I) after acupunture on seven acupoints of stroke. And we calculated difference of skin temperature between healthful and affected side for each groups. Results : There was significant difference in area 3 in both two groups between before and after acupuncture. But in general there Was no significant difference between two groups on thermographic change. Conclusions : This is pilot study, so further studies are required to find out the effect of seven acupoints of stroke in cerebrovascular hemiplegia patients.

The Method of medical Infrared Thermographic imaging using an Infrared LED Lamps (적외선 LED 램프를 이용한 적외선 체열 영상 진단)

  • Song, M.J.;Ryu, S.M.;Soo, B.M.;Kim, J.S.;Choi, W.S.;Park, C.B.;Kim, T.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.282-282
    • /
    • 2010
  • LED Device was designed of electronic circuits of electrical power part for used Pspice student version and used Infrared LED lamps of load part. LED was used Computerized Electronic Medical Infrared Thermographic Imaging System for body surface Investigation of variable Body thermal asymmetry. It was knowledge body thermal Asymmetry of body surface and quantity body surface of electromagnetic wave to inflow electrical power part.

  • PDF

Development of an algorithm for Controlling Welding Bead Using Infrared Thermography (적외선 카메라를 이용한 용접비드를 제어하기 위한 알고리즘 개발)

  • ;;;;;Y.Prasad
    • Journal of Welding and Joining
    • /
    • v.18 no.6
    • /
    • pp.55-61
    • /
    • 2000
  • Dynamic monitoring of weld pool formation and seam deviations using infrared vision is described in this paper. Isothermal contours representing heat dissipation characteristics during the process of arc welding were analysed and processed using imaging techniques. Maximum bead width and penetration were recorded and the geometric position in relation to the welding seam was measured at each sampling point. Deviations from the desired bead geometry and welding path were sensed and their thermographic representations were digitised and welding path were sensed and their thermographic representations were digitised and subsequently identified. Evidence suggested that infrared thermography can be utilized to compensate for inaccuracies encountered in real-time during robotic arc welding.

  • PDF

The Cut Off Values for Diagnosing Cold Hypersensitivity of Hands by Using Digital Infrared Thermographic Imaging (적외선 체열 촬영을 이용한 수부냉증 진단의 절단값 산정)

  • Jo, Jun-Young;Park, Kyoung-Sun;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub;Lee, Jin-Moo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.25 no.3
    • /
    • pp.95-102
    • /
    • 2012
  • Purpose: The purpose of this study is to define the cut off values of cold hypersensitivity of hands by using digital infrared thermographic imaging(DITI). Methods: Thermographic images of 130 patients with cold hypersensitivity of hands(CHHG, n=65) and non-cold hypersensitivity of hands(NCHHG, n=65) were retrospectively reviewed. We used the temperature difference the palm(PC8) and the upper arm(LU4) for diagnosing cold hypersensitivity of hands. The temperature differences of between two groups were analysed using independent samples t-tests. The cut off values were calculated by ROC curve analysis. Analyses were undertaken using SPSS version 17.0. P value of < 0.05 was considered significant. Results: The temperature difference the palm(PC8) and the upper arm(LU4) were significantly different between groups(p < 0.001). Using receiver operating characteristic curve analysis, the sensitivity, specificity, and area under the curve were 70.8%, 73.8%, respectively both hands. The AUC was 0.822 on right hand and 0.818 on left hand. The optimum cut-off value was defined as $-0.05^{\circ}C$. Conclusions: These results suggest that DITI is a reliable instrument for estimating the cold hypersensitivity of hands.

Fabrication of [320×256]-FPA Infrared Thermographic Module Based on [InAs/GaSb] Strained-Layer Superlattice ([InAs/GaSb] 응력 초격자에 기초한 [320×256]-FPA 적외선 열영상 모듈 제작)

  • Lee, S.J.;Noh, S.K.;Bae, S.H.;Jung, H.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.1
    • /
    • pp.22-29
    • /
    • 2011
  • An infrared thermographic imaging module of [$320{\times}256$] focal-plane array (FPA) based on [InAs/GaSb] strained-layer superlattice (SLS) was fabricated, and its images were demonstrated. The p-i-n device consisted of an active layer (i) of 300-period [13/7]-ML [InAs/GaSb]-SLS and a pair of p/n-electrodes of (60/115)-period [InAs:(Be/Si)/GaSb]-SLS. FTIR photoresponse spectra taken from a test device revealed that the peak wavelength (${\lambda}_p$) and the cutoff wavelength (${\lambda}_{co}$) were approximately $3.1/2.7{\mu}m$ and $3.8{\mu}m$, respectively, and it was confirmed that the device was operated up to a temperature of 180 K. The $30/24-{\mu}m$ design rule was applied to single pixel pitch/mesa, and a standard photolithography was introduced for [$320{\times}256$]-FPA fabrication. An FPA-ROIC thermographic module was accomplished by using a $18/10-{\mu}m$ In-bump/UBM process and a flip-chip bonding technique, and the thermographic image was demonstrated by utilizing a mid-infrared camera and an image processor.

Infrared Thermal Imaging in Patients with Medial Collateral Ligament Injury of the Knee - A Retrospective Study

  • Yang, HyunJung;Park, HaeIn;Lim, Chungsan;Park, SangKyun;Lee, KwangHo
    • Journal of Pharmacopuncture
    • /
    • v.17 no.4
    • /
    • pp.50-54
    • /
    • 2014
  • Objectives: Digital infrared thermographic imaging (DITI) has been used widely for various inflammatory diseases, circulatory diseases, skin diseases, musculoskeletal diseases and cancers. In cases of ligament injury, obviously the temperature of the damaged area increases due to local inflammation; however, whether the temperature also increases due to DITI has not been determined. The purpose of the present study was to identify whether or not the changes of temperature in patient's with medial collateral ligament injury were really due to infrared thermography and to determine the applicability of DITI for assessing ligament injuries. Methods: Twenty patient's who underwent DITI for a medial collateral ligament injury from September 2012 to June 2014 were included in the current study. The thermographic images from the patient's knees were divided to cover seven sub-areas: the middle of the patella, and the inferomedial, the inferolateral, the superomedial, the superolateral, the medial, and the lateral regions of patella. The temperatures of the seven regions were measured, and the temperature differences between affected and unaffected regions were analyzed by using the Wilcoxon signed rank test. Results: The 20 patient's were composed of 14 women (70%) and 6 men (30%), with a mean age of $62.15{\pm}15.71$ (mean${\pm}$standard deviation (SD)) years. The temperature of the affected side, which included the middle of the patella, and the inferomedial, the superomedial, the superolateral, and the medial regions, showed a significant increase compared to that of the unaffected side (P < 0.05). The inferolateral and the lateral regions showed no significant changes. Conclusion: Our study results suggest that DITI can show temperature changes if a patient has a ligament injury and that it can be applied in the evaluation of a medial collateral ligament injury.

A Case Report on the Effects of Gamiguibi-tang Combined with Sweet Bee Venom to Improve Raynaud's Disease (봉약침 치료와 병행한 가미귀비탕으로 호전된 레이노병 환자 치험 1례)

  • Lee, Myeong-hwa;Son, byeon-woo;Kim, Kyoung-min;Kim, Young-kyun
    • The Journal of Internal Korean Medicine
    • /
    • v.38 no.5
    • /
    • pp.698-708
    • /
    • 2017
  • Objectives: The aim of this study was to report the clinical effects of a combination of Gamiguibi-tang and sweet bee venom on a patient with Raynaud's disease. Methods: The patient with Raynaud's disease was treated with Gamiguibi-tang three times a day for 43 days and with sweet bee venom daily. The effects on Raynaud's disease were measured on both hands using a cold stress test and an infrared thermometer and by digital infrared thermographic imaging and a NRS (Numeric Rating Scale). We conducted the cold stress test at 6-8 day intervals from 2016.04.27 to 2016.06.08. Results: After treatment, the symptoms of pain were decreased in both hands and digital infrared thermographic imaging (DITI) confirmed a rise in the temperature of the fingers. The fingertip temperature increased from 29.6 to 30.4 degrees and the cooling/rewarming ratio (CRR) increased steadily. No adverse events were found at discharge. Conclusions: Gamiguibi-tang combined sweet bee venom may improve symptoms in patients with Raynaud's disease.