• Title/Summary/Keyword: Infrared: imaging

Search Result 763, Processing Time 0.036 seconds

Monitoring of the Volcanic Ash Using Satellite Observation and Trajectory Analysis Model (인공위성 자료와 궤적분석 모델을 이용한 화산재 모니터링)

  • Lee, Kwon-Ho;Jang, Eun-Suk
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.1
    • /
    • pp.13-24
    • /
    • 2014
  • Satellite remote sensing data have been valuable tool for volcanic ash monitoring. In this study, we present the results of application of satellite remote sensing data for monitoring of volcanic ash for three major volcanic eruption cases (2008 Chait$\acute{e}$n, 2010 Eyjafjallaj$\ddot{o}$kull, and 2011 Shinmoedake volcanoes). Volcanic ash detection products based on the Moderate Resolution Imaging Spectro-radiometer (MODIS) observation data using infrared brightness temperature difference technique were compared to the forward air mass trajectory analysis by the HYbrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model. There was good correlation between MODIS volcanic ash image and trajectory lines after the volcanic eruptions, which support the feasibility of using the integration of satellite observed and model derived data for volcanic ash forecasting.

Endoscopic Fluorescence Angiography with Indocyanine Green : A Preclinical Study in the Swine

  • Cho, Won-Sang;Kim, Jeong Eun;Kim, Sae Hoon;Kim, Hee Chan;Kang, Uk;Lee, Dae-Sic
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.513-517
    • /
    • 2015
  • Objective : Microscopic indocyanine green (ICG) angiography is useful for identifying the completeness of aneurysm clipping and the preservation of parent arteries and small perforators. Neuroendoscopy is helpful for visualizing structures beyond the straight line of the microscopic view. We evaluated our prototype of endoscopic ICG fluorescence angiography in swine, which we developed in order to combine the merits of microscopic ICG angiography and endoscopy. Methods : Our endoscopic ICG system consists of a camera, a light source, a display and software. This system can simultaneously display real-time visible and near infrared fluorescence imaging on the same monitor. A commercially available endoscope was used, which was 4 mm in diameter and had an angle of $30^{\circ}$. A male crossbred swine was used. Results : Under general anesthesia, a small craniotomy was performed and the brain surface of the swine was exposed. ICG was injected via the ear vein with a bolus dose of 0.3 mg/kg. Visible and ICG fluorescence images of cortical vessels were simultaneously observed on the display monitor at high resolution. The real-time merging of the visible and fluorescent images corresponded well. Conclusion : Simultaneous visible color and ICG fluorescent imaging of the cortical vessels in the swine brain was satisfactory. Technical improvement and clinical implication are expected.

Assessing the Potential of Thermal Imaging in Recognition of Breast Cancer

  • Zadeh, Hossein Ghayoumi;Haddadnia, Javad;Ahmadinejad, Nasrin;Baghdadi, Mohammad Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8619-8623
    • /
    • 2016
  • Background: Breast cancer is a common disorder in women, constituting one of the main causes of death all over the world. The purpose of this study was to determine the diagnostic value of the breast tissue diseases by the help of thermography. Materials and Methods: In this paper, we applied non-contact infrared camera, INFREC R500 for evaluating the capabilities of thermography. The study was conducted on 60 patients suspected of breast disease, who were referred to Imam Khomeini Imaging Center. Information obtained from the questionnaires and clinical examinations along with the obtained diagnostic results from ultrasound images, biopsies and thermography, were analyzed. The results indicated that the use of thermography as well as the asymmetry technique is useful in identifying hypoechoic as well as cystic masses. It should be noted that the patient should not suffer from breast discharge. Results: The accuracy of asymmetry technique identification is respectively 91/89% and 92/30%. Also the accuracy of the exact location of identification is on the 61/53% and 75%. The approach also proved effective in identifying heterogeneous lesions, fibroadenomas, and intraductal masses, but not ISO-echoes and calcified masses. Conclusions: According to the results of the investigation, thermography may be useful in the initial screening and supplementation of diagnostic procedures due to its safety (its non-radiation properties), low cost and the good recognition of breast tissue disease.

Development of Smart-phone based Thermal Imaging Diagnostic System for Monitoring Disc Pads of Crane (크레인 디스크 패드 모니터링을 위한 스마트폰 기반의 열영상 진단 시스템 개발)

  • Oh, Yeon-Jae;Park, Kyoung-Wook;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.12
    • /
    • pp.1397-1404
    • /
    • 2014
  • Grab cranes are used for multi-purpose when the sand and soil are deposited into harbor wharf or the undersea construction is performed. Among the components of crane grab, the wire drum and disc brake pad are key expendables and have disadvantages that lot of heat is generated and very expensive when replacing them. In this study, the thermal image analysis for the disc brake, which works with wire drum of the crane is suggested. The suggested system performs the pad thermal diagnosis through the thermal image using the characteristics that the disc and pad surface temperatures are distributed abnormally before the brake failure and the disc pad damage. Therefore, the damage by the failure can be prevented by discovering the abnormality of the machine parts before failure and the life cycle of the pad and the cost can be extended and saved by operating the crane performing constant checkup for the overload.

A Coaxial and Off-axial Integrated Three-mirror Optical System with High Resolution and Large Field of View

  • Chen, Zhe;Zhu, Junqing;Peng, Jiantao;Zhang, Xingxiang;Ren, Jianyue
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.94-100
    • /
    • 2016
  • A novel optical design for high resolution, large field of view (FOV) and multispectral remote sensing is presented. An f/7.3 Korsch and two f/17.9 Cook three-mirror optical systems are integrated by sharing the primary and secondary mirrors, bias of the FOV, decentering of the apertures and reasonable structure arrangement. The aperture stop of the Korsch system is located on the primary mirror, while those of the Cook systems are on the exit pupils. High resolution image with spectral coverage from visible to near-infrared (NIR) can be acquired through the Korsch system with a focal length of 14 m, while wide-field imaging is accomplished by the two Cook systems whose focal lengths are both 13.24 m. The full FOV is 4°×0.13°, a coverage width of 34.9 km at the altitude of 500 km can then be acquired by push-broom imaging. To facilitate controlling the stray light, the intermediate images and the real exit pupils are spatially available. After optimization, a near diffraction-limited performance and a compact optical package are achieved. The sharing of the on-axis primary and secondary mirrors reduces the cost of fabrication, test, and manufacture effectively. Besides, the two tertiary mirrors of the Cook systems possess the same parameters, further cutting down the cost.

The clinical study of Digital lnfrared Thermographic Imaging on Depressed patients (우울증환자(憂鬱症患者)의 전신체열촬영(全身體熱撮影)에 의한 임상적(臨床的) 연구(硏究))

  • Kim, Tae-Heon;Lee, Yong-Keun
    • Journal of Oriental Neuropsychiatry
    • /
    • v.11 no.1
    • /
    • pp.59-73
    • /
    • 2000
  • Depression is a psychiatric syndrom consisting of dejected mood, psychomotor retardation, insomnia and weight loss, sometimes associated with irrational guilt feeling. And it is also similiar to Hwa-byung(火病) symptom in oriental medicine. But it is difficult to diagnose with objective method. Digital Infrared Thermographic Imaging(D.I.T.I.) is one of diagnotic method that measure the changes of skin temperature in body. Specially we checked the skin temperature on depressed patients by using D.I.T.I. and compared with Bell's palsy patients and normal persons group. The results are as follows; Average body temperature of the depressed patient group is $36.68{\pm}0.43^{\circ}C.$ and that of the control group is $36.73{\pm}0.40^{\circ}C.$. So there is no meaningful difference. The depressed patient group has higher temperature than the control group by ${\triangle}T>1.0^{\circ}C$ at the following acupuncture points in these body parts - upper and lower, left and right, anterior and posterior. When acupuncture points temperature was compared superior and inferior part of the body, depressed patient group have meaningful difference at the GV-4(Myung-moon) and also in the control group. When acupuncture points temperature was compared left and right part of the body, depressed patient group have no meaningful difference and also in the control group. When acupuncture points temperature was compared in the anterior and posterior part of the body, depressed patient group have meaningful difference at the GV-4(Myung- moon) and also in the control group. From this study, we think that D.I.T.I. could be used to diagnose objectively on the depressed patients and useful to another psychoneurogenic diagnosis in oriental medicine.

  • PDF

Clinical Study with Thermography on Shoulder Hand Syndrome after Stroke (뇌졸중후(腦卒中後) 견관절(肩關節) 수부(手部) 증후군(症候群)의 적외선(赤外線) 체열(體熱) 촬영(撮影)을 이용(利用)한 임상적(臨床的) 관찰(觀察))

  • Lee, Sang-Hoon;Lee, Yun-Ho
    • The Journal of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.25-39
    • /
    • 1997
  • Shoulder hand syndrome is characterized by pain, vasomotor instability, and tenderness, mainly in the distal upper extremity. The pathophysiologic mechanism of this syndrome is not yet proved. The purpose of this study is to evaluate the usefulness of thermographic imaging on shoulder hand syndrome after stroke for early diagnosis and its clinical pattern analysis including acupuncture and electroacupuncture therapy. This study was performed from June to September in 1996 on 46 stroke patients who were admitted at Oriental hospital of Kyung Hee Medical Center. The study group were 23 patients with shoulder hand syndrome. The control group were 23 patients without shoulder hand syndrome. Skin temperatures on the both upper extremities were measured by Digital Infrared Thermographic Imaging(D.I.T.I.) before the study and 3 weeks later again. The results were as follows; 1. The shoulder hand syndrome group were significantly more restricted in shoulder passive range of motion than the control group. 2. The shoulder hand syndrome group showed significant temperature difference of both dorsal hands. 3. The electroacupunture therapy group were significantly more improved on the temperature difference of both dorsal hands than acupuncture therapy group in 3 weeks later. 4. Both posterior arms showed the biggest temperature difference from 11 to 30 days in shoulder hand syndrome group. 5. The lesser passive ROM(range of motion) of shoulder group showed significantly increased temperature difference of both hands. The above results show that measurement of shoulder passive range of motion and D.I.T.I. is a useful method for early diagnosis on shoulder hand syndrome and its clinical pattern analysis including evaluation of acupuncture and electroacupuncture therapy. Continuous study will be needed for more clinical application and evaluation on shoulder hand syndrome.

  • PDF

Design and Manufacture of an Off-axis Aluminum Mirror for Visible-light Imaging

  • Zhang, Jizhen;Zhang, Xin;Tan, Shuanglong;Xie, Xiaolin
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.364-371
    • /
    • 2017
  • Compared to one made of glass, an aluminum mirror features light weight, compact design, low cost, and quick manufacturing. Reflective mirrors and supporting structures can be made from the same material, to improve the athermal performance of the system. With the rapid development of ultraprecise machining technologies, the field of applications for aluminum mirrors has been developed rapidly. However, most of them are rotationally symmetric in shape, and are used for infrared applications. In this paper, the design and manufacture of an off-axis aluminum mirror used for a three-mirror-anastigmat (TMA) optical system at visible wavelengths is presented. An optimized, lightweight design provides a weight reduction of more than 40%, while the surface deformation caused by earth's gravity can meet the required tolerance. The two pieces of an off-axis mirror can be diamond-turned simultaneously in one setup. The centrifugal deformation of the off-axis mirror during single-point diamond turning (SPDT) is simulated through the finite-element method (FEM). The techniques used to overcome centrifugal deformation are thoroughly described in this paper, and the surface error is reduced to about 1% of the original value. After post-polishing, the form error is $1/30{\lambda}$ RMS and the surface roughness is better than 5 nm Ra, which can meet the requirements for visible-light imaging.

Clinical evaluation of Acupuncture and Herb-Medication on Bell's palsy by DITI (컴퓨터 적외선(赤外線) 전신체열촬영(全身體熱撮影)을 통해 살펴본 Bell' palsy에 대한 한방적 치료의 임상적(臨床的) 고찰(考察))

  • Cho, Eun-Hee;Cho, Nam-Geun;Hur, Tae-Young;Cheon, Mi-Na
    • Journal of Acupuncture Research
    • /
    • v.17 no.2
    • /
    • pp.19-30
    • /
    • 2000
  • Object : This study is designed to evaluate effects of acupuncture and herb-medication by the data of DITI(Digital Infrared Thermographic Imaging) examination and the changes of clinical symptoms after the therapy of acupuncture and herb-medication in the patients with Bell's palsy. Contents : The conservative therapy with acupuncture and herb-medication was performed during 1-8weeks. The acupuncture points of S4, S6, G14, S2, BL2, SI18, TE23, LI4 and S36 was used. In the pre- and post therapy, DITI examinations were performed in patients who had Bell's palsy and were treated by acupuncture simultaneously, and then tried to correlate the results of clinical symptoms with the difference of thermographic findings at pre-and post acupuncture. Setting : The standard routine themographic examinations were performed with thermography (DITI) in the 16 patients with Bell's palsy at pre- and post acupuncture. patients : Thermographic imaging of 16cases was analyzed. They had diagnosed Bell's palsy. They were treated by acupuncture and moxibustion therapy in Wonkwang Oriental Hospital from Jauary, 1999 to February, 2000. Results : The results of treatment showes that 56.25% of patients achieved excellent recovery and 31.25% achieved good recovery. After compairing the DITI results before and after treatment, we found 43.75% of patients achieved excellent recovery and 43.75% achieved good recovery. Conclusion :Acupuncture showed good results over 87.5% in clinical evaluation and 87.5% in DITI. Thermographic examination showes terapeutic effect of acupuncture treatment.

  • PDF

RESEARCH FOR ROBUSTNESS OF THE MIRIS OPTICAL COMPONENTS IN THE SHOCK ENVIRONMENT TEST (MIRIS 충격시험에서의 광학계 안정성 확보를 위한 연구)

  • Moon, B.K.;Kanai, Yoshikazu;Park, S.J.;Park, K.J.;Lee, D.H.;Jeong, W.S.;Park, Y.S.;Pyo, J.H.;Nam, U.W.;Lee, D.H.;Ree, S.W.;Matsumoto, Toshio;Han, W.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.3
    • /
    • pp.39-47
    • /
    • 2012
  • MIRIS, Multi-purpose Infra-Red Imaging System, is the main payload of STSAT-3 (Korea Science & Technology Satellite 3), which will be launched in the end of 2012 (the exact date to be determined) by a Russian Dnepr rocket. MIRIS consists of two camera systems, SOC (Space Observation Camera) and EOC (Earth Observation Camera). During a shock test for the flight model stability in the launching environment, some lenses of SOC EQM (Engineering Qualification Model) were broken. In order to resolve the lens failure, analyses for cause were performed with visual inspections for lenses and opto-mechanical parts. After modifications of SOC opto-mechanical parts, the shock test was performed again and passed. In this paper, we introduce the solution for lens safety and report the test results.