• Title/Summary/Keyword: Infra Red

Search Result 484, Processing Time 0.031 seconds

Studies on the cocoon Boiling by the Infra red-ray Heater (적외선자견에 관한 연구)

  • 남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.10
    • /
    • pp.81-88
    • /
    • 1969
  • This study was carried out to investigate the effects of the cocoon cooking by infra red ray heater established in to the cocoon boiling machine. The results were summarized as follows. 1. According to the cocoons, the non bave end breaking percentage of cocoons was increased to 5∼9% in spring and 2∼10% in autumn. 2. There was no significant in the raw silk percentage. 3. The irradiation effect by the number of infra-red ray heater was different, namely, the raw silk percentage of the excellent cocoons was increased in case of 1 Kwatt irradiation, and that of the inferior cocoons was increased in the 2 Kwatt irradiation. 4. Reeling efficiency was showed to 14% maximum and 3% minimum(index).

  • PDF

Optical design of three-mirror telescope system for infra-red and visible imaging (적외선 및 가시광선 결상용 3반사망원경계의 설계)

  • 이종웅;홍경희;권우근
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.183-190
    • /
    • 1996
  • To design three-mirror telescope system (F/8, 120 inch in focal length) for visible and infra-red band imaging, methods for power configuring and correction of the third order aberrations were studied. In the design of the telescope system, a three-mirror system corrected for spherical aberration, coma, and astigmatism was used for infra-red imaging, and the aberrations were corrected by using conic surfaces. For visible imaging, a singlet corrector lens was appended at the front of the focal plane to correct filed curvature. The telescope system has diffraction limited performance for 10 ${\mu}{\textrm}{m}$ in wavelength within 2.4$^{\circ}$ of field-of-view. In the visible band imaging, the rms spot size of the telescope system is less than 25 ${\mu}{\textrm}{m}$ within 3$^{\circ}$ of field-of-view for monochromatic light, and the telescope system satisfies flat field condition for CCD application.

  • PDF

Detection of Radial Pulse Wave by Photoplethysmogram (광전용적맥파를 이용한 요골동맥 맥파 검출)

  • 정동근;김광년;연규선;최병철;서덕준
    • Journal of Life Science
    • /
    • v.13 no.1
    • /
    • pp.42-46
    • /
    • 2003
  • Photoplethysmogram is widely used to measure heart rate and arterial blood oxygen saturation in human. This paper describes radial pulse waves recorded by photoplethysmogram with 940 nm wavelength infra red light. Radial pulse waves were varied according to the recording site. When recorded on the skin over radial artery, the radial pulse wave was inverted, comparing to the photoplethysmogram at fingertip. The mechanism of inverted pulse wave seemed to be caused by the change of the blood volume in the subcutaneous tissue between radial artery and the skin, which was reduced during systolic period and increased during diastolic period of the cardiac cycle. These results suggest that radial arterial wall may reflect infra red ray.

Comparison of Non-destructive Measuring Methods of Tomato Plant to Detect N, P and Ca Deficient Stresses (토마토 잎의 비파괴 계측에 의한 N, P, Ca 결핍 장해 진단법 비교)

  • 서상룡;류육성;정갑채;성제훈;이성희
    • Journal of Biosystems Engineering
    • /
    • v.25 no.6
    • /
    • pp.517-526
    • /
    • 2000
  • A series of experiments was conducted to evaluate the capability of detecting nutrimental deficient stress of N, P and Ca of a tomato plant using several fast and intact type physiological properties measuring devices - a chlorophyll content meter an infra-red thermometer to measure leaf temperature a chlorophyll fluorescence meter a porometer an optical spectrometer a multi-scan radiometer and a canopy analyzer. to detect N deficient stress a chlorophyll content meter a spectrometer and a multi-scan radiometer were useful and their possibility to detect was estimated as about 50%, 100% and 100% respectively. To detect P deficient stress the infra-red thermometer the porometer and the spectrometer proved their usefulness an their possibility to detect was estimated as about 70%, 70% and 70% respectively. To detect Ca deficient stress an thermometer a porometer a spectrometer and a multi-scan radiometer were useful and their possibility to detect was estimated as about 60%, 70%,80% and 100% respectively. The experiments resulted that use of a spectrometer and a multi-scan radiometer in combination with a chlorophyll content meter an infra-red thermometer and a porometer were desirable to distinguish the nutrimental stress tested in the study.

  • PDF

The Indirect Effects of the Near Infra-Red Light-Treated Materials on Microbial Growth (근적외선을 처리한 생활용품의 향균 효과)

  • Park Kyoung-Hwa;Park Yu-Mi;Seul Kyeung-Jo;Ghim Sa-Youl
    • Microbiology and Biotechnology Letters
    • /
    • v.33 no.3
    • /
    • pp.222-225
    • /
    • 2005
  • Stimulatory effects of near infra-red (NIR) rays radiation have been studied within the limits of photosynthesis, phototaxis, and photodermatology. While most of these studies have been done by direct NIR radiation, we investigated the effects of the NIR rays-treated materials on microbial growth. NIR in wavelength of 1,400${\~}$1,700 nm was applied for different kind of materials. Under fast growing conditions in rich media, materials treated with the NIR rays or not did not show any differences in growth of microorganisms. However, under slow growing conditions in minimal media, data showed that NIR rays-treated cloths and hygienic bands affect negatively on the growth of bacteria (Salmonella enteritidis) and fungi (Candida albicans). In addition, it was estimated that the effect of NIR rays on bacterial growth is kept going on S. enteritidis.

Supervised classification for greenhouse detection by using sharpened SWIR bands of Sentinel-2A satellite imagery

  • Lim, Heechang;Park, Honglyun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.5
    • /
    • pp.435-441
    • /
    • 2020
  • Sentinel-2A satellite imagery provides VNIR (Visible Near InfraRed) and SWIR (ShortWave InfraRed) wavelength bands, and it is known to be effective for land cover classification, cloud detection, and environmental monitoring. Greenhouse is one of the middle classification classes for land cover map provided by the Ministry of Environment of the Republic of Korea. Since greenhouse is a class that has a lot of changes due to natural disasters such as storm and flood damage, there is a limit to updating the greenhouse at a rapid cycle in the land cover map. In the present study, we utilized Sentinel-2A satellite images that provide both VNIR and SWIR bands for the detection of greenhouse. To utilize Sentinel-2A satellite images for the detection of greenhouse, we produced high-resolution SWIR bands applying to the fusion technique performed in two stages and carried out the detection of greenhouse using SVM (Support Vector Machine) supervised classification technique. In order to analyze the applicability of SWIR bands to greenhouse detection, comparative evaluation was performed using the detection results applying only VNIR bands. As a results of quantitative and qualitative evaluation, the result of detection by additionally applying SWIR bands was found to be superior to the result of applying only VNIR bands.

Measurement of Soil Organic Matter Using Near Infra-Red Reflectance (근적외선 반사도를 이용한 토양 유기물 함량 측정)

  • 조성인;배영민;양희성;최상현
    • Journal of Biosystems Engineering
    • /
    • v.26 no.5
    • /
    • pp.475-480
    • /
    • 2001
  • Sensing soil organic matter is crucial for precision farming and environment friendly agriculture. Near infra-red(NIR) was utilized to measure the soil organic matter. Multivariate calibration methods, including stepwise multiple linear regression(MLR), principal components recession(PCR) and partial least squares regression(PLS), were applied to soil spectral reflectance data to predict the organic matter content. The effect of soil particle size and water content was studied. The range of soil organic matter contents was from 0.5 to 11%. Near infrared (NIR) region from 700 to 2,500nm was applied. For uniform soil particle size, result had good correlation (R$\^$2/ = 0.984, standard error of prediction= 0.596). The effect of soil particle size could be eliminated with 1st order derivative of the NIR signal. However. moist soil had a little lower correlation. R$\^$2/ was 0.95 and standard error of prediction was 0.94% using the PLS method. The results showed the possibility of soil organic matter measurement using NIR reflectance on the field.

  • PDF

Face recognition of Intra-red Images for Interactive TV Control System (인터랙티브 TV 컨트롤 시스템을 위한 근적외선 영상의 얼굴 인식)

  • Won, Chul-Ho;Lee, Sang-Heon;Lee, Tae-Gyoun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.5
    • /
    • pp.11-17
    • /
    • 2010
  • In this parer, face recognition method which can be applied to ITCS (interactive TV control system) is proposed. We extracted ULBP(uniform local binary pattern) histogram feature from infra-red images, and we detected left-right eyes and face region by using SVM classifier. Then, We implemented face recognition system which is using Gabor transform and ULBP histogram feature and applied to personal verification for ITCS.