• Title/Summary/Keyword: Inflow condition

Search Result 345, Processing Time 0.025 seconds

A Development and Validation of Cosmetic Container Based on L-Ascorbic Acid Oxidation Property (L-Ascorbic Acid의 산화특성에 따른 화장품 용기 개발 및 유효성 분석)

  • Yoon, Sungwook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.39 no.2
    • /
    • pp.149-158
    • /
    • 2013
  • L-ascorbic acid, the representative antioxidants, has a great effect on skin whitening, collagen synthesis, and anti-aging, but has low oxidative stability during storage. Therefore, in this study, thermal and oxidation properties of L-ascorbic acid under various storage conditions (powder, aqueous phase, changes of temperature, UV-irradiation, and inflow of external air etc.) were investigated. And the storage stability of ingredient was validated in the double-spaced pouch by analysing oxidation properties under each storage conditions (powder phase and blended with essence). In oder to analyze the thermal properties, TGA, DSC, and FT-IR analysis were carried out and UV-visible spectrophotometer & redox titration were used in parallel for oxidation property analyses. From the result of experiment, L-ascorbic acid was oxidized fast when it contained lots of metallic ion, hydroxy ion in aqueous solution under high temperature, UV-irradiation & inflow external air, whereas it was not oxidized for a long time when it was stored as pure powder although it has same condition as heating up, UV-irradiation & inflow external air. Based on this result, retention period of cosmetics which is using L-ascorbic acid, less stable material in oxidation can be innovatively increased when using double-spaced pouch that is designed and produced for separating storage of active ingredients.

The Effects of Operational and Mechanical Factors on the Performance of Rice-Husk Furnace (왕겨연소기(燃燒機)의 성능(性能)에 영향(影響)을 마치는 설계(設計) 및 작동인자(作動因子)에 관(關)한 연구(硏究))

  • Park, Seung Je;Noh, Sang Ha
    • Journal of Biosystems Engineering
    • /
    • v.8 no.2
    • /
    • pp.39-48
    • /
    • 1983
  • This study was performed to obtain the basic data which could be used for the modification of the manual center-burner-type rice-husk furnace into a small scale automatic type for the multi-purpose use in the farm. For this purpose, first, the utilization feasibility of the rice-husk furnace in the farm was analyzed briefly in aspects of available amount of rice-husk for the fuel, annual operation time and replaceble amount of residential heating energy with rice-husk in the farm. For the experiment a prototype furnace geared with an automatic feeding device was fabricated, and feed rate, mold size and chimney height were changed to investigate the combustion efficiency of rice-husk and thermal efficiency of the furnace. Also, optimum and limiting operational factors were observed in each treatments. The results obtained are summarized as follows. 1. If the rice-husk is intensively used for residential heating in the farm for winter season, on an average 51 percent of the total heating energy can be replaced with the rice-husk. Therefore, development of a small scale automatic rice-husk furnace was recognized to be feasible. 2. The operational condition depending on husk-feed rates was very important factor for successive steady burning operation of the given furnace. When the feed-rate was 1.5 kg/hr, the top of the burning zone should be kept at the position about 55 cm from the bottom of the combustion chamber with the periodic removal of ash (termed as steady state position), which was 18 cm above the mold waist. When the feed rates were 2.4 kg/hr and 3.0 kg/hr, the steady state position was at about 4 cm above the mold waist. 3. The mold size affected inflow rate of air into the furnace and consequently CO content in the exhaust gas. The relatively bigger mold gave positive effect on the air-inflow rate. 4. When the husk-feed rates were 1.5 kg/hr, 2.4 kg/hr, 3.0 kg/hr, the combustion efficiencies of the rice-husk were 98.5%, 97.4% and 95.0%, the thermal efficiencies of the furnace were 93.4%, 93.2% and 87.6%, and CO content in the exhaust gas were 1.21%, 1.03%, and 2.43%, respectively. The air-inflow rates were decreased with the increase of feed rates. When the amount of excess air was 30-40%, the CO content in the exhaust gas was at the minimum level. 5. When the chimney height was lowered from 260 cm to 96 cm, the air-inflow rate was slightly decreased, but the average temperature in the combustion chamber, CO content in the exhaust gas and combustion and thermal efficiencies were not changed significantly. 6. The incidental problems associated with the protytype furnace were accumulation of the ash inside the mold, accumulation of the cinder between the outer-drum of the furnace and the combustion chamber wall, and accumulation of the cinder in the chimney.

  • PDF

A Study on the Flow Characteristics around Tidal Current Turbine (조류발전용 터빈 주위의 유동 특성에 관한 연구)

  • Kim, Bu-Gi;Yang, Chang-Jo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.6
    • /
    • pp.610-616
    • /
    • 2012
  • All the countries in the world is currently facing the full scale of energy-climate era currently, and making strong energy policy that will lead to green growth of the future energy resources by utilizing renewable energy as the basis of entering the advanced country becomes the goal of development that satisfies the demand for energy in 21st century. Recently, ocean energy attracted the attention along with the necessity of developing renewable energy. Ocean energy is the one of most prominent recyclable and clean resources that has not been developed yet. So, it is highly required to develop good tidal current energy conversion system in coastal area. The inflow angle that acts against tidal current turbine, seabed effect and the change of efficiency along the occurrence of cavitation were investigated through the wake flow characteristics in this study. Power coefficient degradation by seabed effect did not appear in the condition of this calculation. Efficiency degradation appeared from above $10^{\circ}$ regarding inflow angle and power coefficient was calculated as lower by 7 % at $45^{\circ}$. Torque and power coefficient increased as inflow velocity rose, but power coefficient degradation appeared from above 3m/s when the cavitation happened. So, it was recognized that the larger inflow angle and occurrence of cavitation become the reason for power degradation through the flow characteristics.

Determination for Inflow Routes of Insects Caused by Manufacturing and Drinking Process in Korean Rice-wine (한국 전통약주에서 제조 및 음용 과정 중 발생하는 곤충의 혼입 경로에 대한 판정)

  • Kim Seung-jin;Lee Jeoung-hoon;Choi Yuung-hwan;Kim Gye-won
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.3
    • /
    • pp.123-127
    • /
    • 2005
  • To determine the possibility of inflow routes for insect in Korean rice-wine, we investigated catalase (CAT) activity and oxygen bubble formation through stereoscopic microscope in pasteurized insects (bee, fly, fruit fly) treated with $H_2O_2$. The pasteurization condition was 30 and 60 min heating at 65 and $70^{\circ}C$. Bubble was not shown under the CAT level of 50 $\mumoles/min/ml$. CAT activity level was more sensitive compared with oxygen bubble formation, but the CAT activity had correlation with oxygen bubble formation method. We also tested bubble formation at room temperature, 65 and $70^{\circ}C$ for 30 days. The bubble formation was slowly decreased in all insects at room temperature during experiment, but it was rapidly decreased at 65 and $70^{\circ}C$. The fruit fly was not shown bubble formation at 65 and $70^{\circ}C$. These results suggest that bubble farmation method was a new simple method for inflow routes of insects caused by manufacturing and drinking process in pasteurized Korean rice-wine.

A Study on Evaluation of Water Supply Capacity with Coordinated Weirs and Multi-reservoir Operating Model (댐-보 최적 연계운영을 통한 용수공급능력 평가에 관한 연구)

  • Chae, Sun-Il;Kim, Jae-Hee;Kim, Sheung-Kown
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.8
    • /
    • pp.839-851
    • /
    • 2012
  • When we evaluate the water supply capacity of a river basin, it is a common practice to gradually increase the water demand and check if the water demands are met. This practice is not only used in the simulation approach, but also in the optimization approach. However, this trial and error approach is a tedious task. Hence, we propose a two-phase method. In the first phase, by assuming that the decision maker has complete information on inflow data, we use a goal programming model that can generate the maximum water supply capacity at one time. In the second phase, we simulate the real-time operation for the critical period by utilizing the water supply capacity given by the goal programming model under the condition that there is no foresight of inflow. We applied the two-phase method to the Geum-River basin, where multi-purpose weirs were newly constructed. By comparing the results of the goal programming model with those of the real-time simulation model we could comprehend and estimate the effect of perfect inflow data on the water supply capacity.

Evaluation of Soil-Water Characteristic Curve for Domestic Bentonite Buffer (국내 벤토나이트 완충재의 함수특성곡선 평가)

  • Yoon, Seok;Jeon, Jun-Seo;Lee, Changsoo;Cho, Won-Jin;Lee, Seung-Rae;Kim, Geon-Young
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.1
    • /
    • pp.29-36
    • /
    • 2019
  • High-level radioactive waste (HLW) such as spent fuel is inevitably produced when nuclear power plants are operated. A geological repository has been considered as one of the most adequate options for the disposal of HLW, and it will be constructed in host rock at a depth of 500~1,000 meters below ground level with the concept of an engineered barrier system (EBS) and a natural barrier system. The compacted bentonite buffer is one of the most important components of the EBS. As the compacted bentonite buffer is located between disposal canisters with spent fuel and the host rock, it can restrain the release of radionuclides and protect canisters from the inflow of groundwater. Because of inflow of groundwater into the compacted bentonite buffer, it is essential to investigate soil-water characteristic curves (SWCC) of the compacted bentonite buffer in order to evaluate the entire safety performance of the EBS. Therefore, this paper conducted laboratory experiments to analyze the SWCC for a Korean Ca-type compacted bentonite buffer considering dry density, confined or unconfined condition, and drying or wetting path. There was no significant difference of SWCC considering dry density under unconfined condition. Furthermore, it was found that there was higher water suction in unconfined condition that in confined condition, and higher water suction during drying path than during wetting path.

A Study on Release Characteristics of Sediment and its Impacts on Water Quality in Daecheong Dam Reservoir (대청댐 저수지 퇴적물의 용출특성과 수질에 미치는 영향에 관한 연구)

  • Lee, Yo-Sang;Lee, Kyeong-Sik
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.2
    • /
    • pp.99-107
    • /
    • 2000
  • In order to solve water quality problem of domestic dam reservoir, many projects have been performed in a point of view to restoration of water quality. This study was carried out to evaluate the effect of release from sediment on water quality and release characteristics. Daecheong dam reservoir was investigated for two years, from 1998 to 1999. The nutrient release rates of Daecheong reservoir is less than foreign eutrophic reservoir at anoxic condition. For the evaluation of the effect of nutrient release on water quality, internal and external loading was calculated at Daecheong reservoir. As total phosphorus loading from sediment is calculated 9.3 ton/yr and inflow loading from Daecheong reservoir watershed 118 ton/yr, internal loading shows the portion of 7.88% to external loading. At this study, because sampling point was choosed at the point where much sediment is accumulated, experimental result is more than average release rates. Because Daecheong reservoir shows complete thermal stratification and anoxic condition below 30m from water surface in summer seasons, released phosphorus from sediment can not transfer to epilimnion and eventually resettles. Therefore sediment has insignificant impacts on water quality on Daecheong dam reservoir.

  • PDF

An Analysis on Influence of Geographical Variation Induced by Development Affecting to the Local Scale Wind Environment - Numerical Simulation using the Envi-met Model - (개발에 따른 지형변화가 국지 바람장에 미치는 영향 분석 - Envi-met 모형을 이용한 수치모의 -)

  • Jung, Woo-Sik;Park, Jong-Kil;Lee, Hwa-Woon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.888-903
    • /
    • 2006
  • This study analyze the change of wind pattern and intensity according to the transform of surface conditions, such as land use and height of terrain, over the leeward region. In order to do this, we have employed 'Envi-met' microscale atmospheric numerical model. When the same wind condition is considered, the wind speed of base case having natural surface condition of Chunsudae shows the weakest strength among different cases such as the 'bare case' and the '20 m case' which the plants is removed and the height of terrain is flatted as 20 m above the sea level over the Chunsudae, respectively. The weakening of wind speed is a maximum of $4{\sim}8 m/s$ when the inflow wind speed is 55 m/s.

Analysis on Design Parameters of Small Hydropower Sites with Rainfall Conditions (강우상태에 따른 소수력발전입지의 설계변수 특성 분석)

  • Lee, Chul-Hyung;Park, Wan-Soon
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.59-64
    • /
    • 2012
  • The correlation between hydrologic performance design parameters of small hydro power(SHP) sites and rainfall condition have been analyzed for major river systems. The model, which can predict flow duration characteristic of stream, was developed to estimate the inflow caused from rainfall. And another model to predict hydrologic performance for SHP plants is established. Based on the models developed in this study, the hydrologic performance characteristics for SHP sites have been analyzed. The results show that the hydrologic performance characteristics of SHP sites have some difference between the river systems. Especially, the specific design flowrate and specific output of SHP sites located on North Han river and Nakdong river systems have large difference compared with other river systems. It was found that the hydrologic performance design parameters such as specific design flowrate and specific output were affected by rainfall condition in basin area of SHP sites.

A Study of Actual Condition on Operation and Management of Environmental Infrastructure in the Geum River System (금강수계 내 환경기초시설 운영실태에 관한 연구)

  • Lee, Jae-Woon;Park, Dong-Gi;Kwon, Young-Ho
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.1
    • /
    • pp.1-12
    • /
    • 2009
  • The various environmental problems that we face on today are basically about environmental quality. Since early 1960s affluent material was produced because of remarkable economic growth by many cooperations. However, for the lack of environmental policy, environmental pollutions has been serious. The central government should transfer the producing and consuming structure to environmental affinity through the regulations for developing Korea as a model of environmental nation which takes an active part in global environmental programme and in which the environment and economy are well harmonized. Moreover, the central government should take the lead in prevention of environmental pollution through the direct policies such as strengthening the discharge limit or setting up environmental basic institutions by securing budget for conserving environment. This thesis emphasize on the public institution among many environmental basic institutions for environmental anti-pollution project. It will find the problems with running those institutions, and will suggest the preview of improvement. Also, it is necessary to investigate of variation trend for inflow and pollutant loading to environmental infrastructure as increased of the diffusion rate as established and maintenance of sewer system. The purpose of this study is to investigate for inflow and pollutant loading to environmental infrastructure, and also to provide the method of efficiently maintenance and management. The results obtained were summarized as follows; 1. Survey of actual condition on operation and management of environmental infrastructure was evaluated the propriety of treatment process and problem of plant management. 2. Analysis of pollutant loading contribution for river system of environmental infrastructure with data analysis of water quality measuring network. 3. To investigate on case study for efficiently maintenance and management of environmental infrastructure. The result on this study was provide the method of efficiently maintenance and management with survey for establish and repair of sewer system and survey of actual condition on operation and management of environmental infrastructure in the water area of discharge to Geum River System. Application as guideline for establish and management of environmental infrastructure, and management of Geum River System. Also, application for preliminary data for fulfill-assess of total effluent regulation of water pollution.