• 제목/요약/키워드: Inflow concentration

검색결과 373건 처리시간 0.025초

대형건축물 저수조의 수질실태 및 개선방안에 관한 연구 (A Study on the Water Quality of Reservoir Tank in the Building Complex on Jeonnam Area)

  • 이지헌;이해훈;김환범;안길원;박귀님;김양기;배주순;문희;박철웅;오은하;박송인;서윤규
    • 환경위생공학
    • /
    • 제15권4호
    • /
    • pp.59-77
    • /
    • 2000
  • This study was carried out to investigate on several factors, which contaminative the water quality through the water pipe during feeding water, in 42 largescaled apart-ments(total 84 cases) and assayed the Volatile Organic Compounds(VOCs) and concen-tration of heavy metals that inflow and outflow in reservior water in Jeonnam area(Mokpo, Suncheon, Yeosu) from January 1999 to December 1999. The results obtained were summarized as follows ; 1. The quality of the water pipe composition in the order of frequency in the quality of water pipes were Copper(45.2%)> Zinc(38.9%)> Stainless steel(9.5%)> PVC(4.8%)> PM(2.4%) in observing 42 sites. All of the drain pipes were used the cast iron quality. 2. The result of certification curve from 12 items(17kind) of VOCs was $1.0-4.0{\mu{g}}/{\ell}$ range, a coefficient of correlation was shown 0.99 over. A MDL of each substance range was within $0.1-1.0{\mu{g}}/{\ell}$. 3. The result of the assay, 5 kinds(Viny chloride, Dichloromethane, Ethylbenzene, M,P-xylene, Styrene) of the VOCs of 14 kinds was not detected and the other items were detected slightly. The detection rate of one item and over in total VOCs samples, were 25.9% in inflow and 27.9% in outflow. And frequency of detect in inflow/outflow of THM(Chloroform, Bromodichloro-methane, Dibromochloromethane, Bromoform) were shown higher than 94.1%, 97.0% each stages. It comes to the conclusion that all of the samples were reason able for drinking water standards. 4. The coefficient of correlation were reasonable, it shown 0.999 over in $0.1-1.0{\mu{g}}/{\ell}$ of a measuring range conditions of 4kinds in organic substance(Zn, Cu, Fe, Mn). 5. The results were showed suitability in 78 cases(92.9%) and unsuitability in 6 cases (7.1%), in 84 cases of in organic substances. Compare to inflow stage, mean concentrations of heavy metal, were increased slightly in Zn, Cu, Fe except Mn than outflow stage. The result of the mean concentration in organic substance inflow and outflow in the apartment water tank using Pair-compared T-test, in 95% reliance index, were $0.179mg/{\ell}(0.151-0.307mg/{\ell})$ in Zinc, $0.136mg/{\ell}(0.113-0.230mg/{\ell})$ in Copper, $0.052mg/{\ell}(0.048-0.098mg/{\ell})$ in Fe, and there was a bit growing tendency but there was no differece in Mn. 6. The mean concentration of Copper which used Cu pipe as a water supply pipe in apartment were $0.216mg/{\ell}(0.161-0.338mg/{\ell})$ in case of the Zine pipe were $0.286mg/{\ell}(0.204-0.435mg/{\ell})$. It shows that the detection rate was more higher than the other material used in Cu or Zn as the water supply pipe. We supposed to Cu and Zn substance were gushing out water supply pipe.

  • PDF

인공습지에 의한 농촌오수처리에 관한 연구 (Study on Natural Wastewater Treatment Systems by Constructed Wetland for Rural Area)

  • 윤춘경;권순국;김형중
    • 한국농공학회지
    • /
    • 제39권4호
    • /
    • pp.55-63
    • /
    • 1997
  • Constructed wetland system which can be applied to the rural wastewater treatment system was examined by pilot plant in Kon-Kuk University. Hydraulic loading rate of wastewater was about 0.16m$^3$/m$^2$. day and theoretical detention time in the system was 1.38 days. The effluent of the septic tank for the school building was applied as inflow to the system. The influent concentration of DO was zero but effluent was up to 4.37mg/${\ell}$ which implies that oxygen was supplied enough from atmosphere by reaeration to support biological activity of the system. Average influent concentration of BOD was 104mg/${\ell}$ and effluent was 24mg/${\ell}$ with average removal rate of 76%. Average influent concentration of COD was 215mg/${\ell}$ and effluent was 63mg/${\ell}$ with average removal rate of 70 % . Average influent concentration of SS was 78mg/${\ell}$ and effluent was 10mg/${\ell}$ with average removal rate of 87%. Two components, BOD and SS, are regulated by law to keep maximum water quality standard of 80mg/${\ell}$ when daily outflow rate is less than 100$m^3$/day which is the case of most rural communities. Therefore, the results from the experiment showed that constructed wetland system can meet the water quality standard easily. Average influent concentration of total nitrogen was 165mg/lwhich is relatively higher than normal wastewater, and effluent was about 156mg/${\ell}$ with average removal rate of only 6%. Average influent concentration of total phosphorus was 41 mg/${\ell}$ and effluent was 6mg/${\ell}$ with average removal rate of 87%. Overall, constructed wetland system was thought to be effective to treat wastewater if nitrogen removal mechanism is improved. Considering low cost, less maintenance, and high treatability, this system can be a practical alternative for the wastewater treatment in rural area The experiment was performed during the summer and fall season, and treatment efficiency of the system is expected to decrease in low temperature. therefore, further study including temperature is required to evaluate feasibility of the system more in detail.

  • PDF

연안도서지역 소하천 유역의 홍수도달시간 산정 (Estimate of Time of Concentration for Stream at Island near Coastal Region)

  • 정연중;최계운;한만신;정상만
    • 한국방재학회 논문집
    • /
    • 제7권5호
    • /
    • pp.151-158
    • /
    • 2007
  • 인천연안도서지역 소하천의 홍수도달시간을 산정하기 위하여 영흥도의 9개 소하천을 대상으로 11개 지점에 수위표를 설치하고 실제 강우사상에 대하여 유량을 산정하였다. 실무에서 주로 사용되고 있는 홍수도달시간공식을 이용하여 유량산정 지점별 홍수도달시간을 산정하였으며, 유입시간을 고려하기 위하여 3가지 방법으로 비교하였고, 도표에 의한 방범을 채택하였다. 유출모형을 이용하여 산정된 첨두홍수량 발생시간과 관측된 첨두유량 발생시간을 비교 분석하였다. 연안도서지역에 적합한 도달시간공식으로 Kirpich공식을 채택하였으며, 통상적으로 알려진 Kirpich공식의 적용범위가 유역면적 $0.453km^2$이하로 하도경사 $3{\sim}5%$까지 였으나, 본 연구를 통하여 유역면적을 $2.0km^2$까지 확대하고 유역면적 증가에 따라 하도경사도 1.5%까지 확대 사용 가능하도록 적용범위를 확대하여 제안하였다.

한강수계 농업용저수지 관리방안 (Management Measures for the Control of Agricultural Reservoirs in Han River Watershed)

  • 김호섭;공동수;정동일;황순진
    • 한국물환경학회지
    • /
    • 제25권3호
    • /
    • pp.386-393
    • /
    • 2009
  • This study was carried out to assess water quality and to introduce the management measures for water quality improvement with the collected data from 87 agricultural reservoirs in Han river watershed. According to the water quality criteria (WQC) for lake based on the COD, TP, TN and chl.a concentration, 18, 16, 4 and 19 of 87 reservoirs exceed class IV, respectively. Based on the trophic state index (TSI) with chl.a concentration, 51 of selected reservoirs appeared to be eutrophic. Phosphorus was limiting nutrient on algal growth in 58 reservoirs. TP, chl.a and COD concentration in 23 of 49 agricultural reservoirs with chl.a concentration ${\geq}25{\mu}g/L$ and eutrophic exceed class IV by WQC. Also, the mean depth in 21 of 23 reservoirs was below 5m. Our results suggest that advanced wastewater treatment and crop land control in watershed of reservoirs with TP concentration ${\geq}0.1mg/L$ would be a effective tool to improve water quality. Dredging would to be effective measure in reservoirs with mean depth < 5 m and relatively old age. In reservoirs with chl.a concentration ${\geq}50{\mu}g/L$, application of technique such dissolved air flotation (DAF) and P inactivation be effective to improve water quality by removing particulate matters in water column. The management measure to control inflow such as sedimentation basin, Pre-dam and diversion would to be application in reservoirs with shallow depth, while large watershed and surface area.

안동시 저수지에서의 대량 어류 폐사에 대한 원인과 대책에 관한 연구 (Study on Causes and Countermeasures for the Mass Death of Fish in Reservoirs in Andong-si)

  • 배수호;황선진;김연정;정철호;김성윤;유건상
    • 한국환경농학회지
    • /
    • 제42권1호
    • /
    • pp.52-62
    • /
    • 2023
  • This study focused on determining the specific causes and prevention methods of mass fish deaths occurred in five reservoirs (Gagugi, Neupgokgi, Danggokgi, Sagokji, and Hangokji) in Andong-si. For this purpose, a survey of agricultural land and livestock in the upper part of the reservoirs and analysis of water quality in the reservoir irrespective of whether it rains or not were conducted. We attempted to examine the changes in dissolved oxygen (DO) in the surface and bottom layers of reservoirs and changes in DO depending on the amount of livestock compost and time. Based on the above investigations, treatment plans were established to efficiently control the inflow of contaminated water into reservoirs. The rainfall and farmland areas in the upper part of the reservoir were investigated using Google and aviation data provided by the Ministry of Land, Infrastructure, and Transport. The current status of livestock farms distributed around the reservoirs was also examined because compost from these farms can flow into the reservoir when it rains. Various water quality parameters, such as phosphate phosphorus (PO4-P) and ammonium nitrogen (NH3-N), were analyzed and compared for each reservoir during the rainy season. Changes in the DO concentration and electrical conductivity (EC) were also observed at the inlet of the reservoir during raining using an automated instrument. In addition, DO was measured until the concentration reached 0 ppm in 10 min by adding livestock compost at various concentrations (0.05%, 0.1%, 0.3%, and 0.5% by wt.), where the concentration of the livestock compost represents the relative weight of rainwater. The DO concentration in the surface layer of reservoirs was 3.7 to 5.3 ppm, which is sufficient for fish survival. However, the fish could not survive at the bottom layer with DO concentration of 0.0-2.1 ppm. When the livestock compost was 0.3%, DO required 10-19 h to reach 0 ppm. Considering these results, it was confirmed that the DO in the bottom layer of the reservoir could easily change to an anaerobic state within 24 h when the livestock compost in the rainwater exceeds 0.3%. The results show that the direct cause of fish mortality is the inflow of excessive livestock compost into reservoirs during the first rainfall in spring. All the surveyed reservoirs had relatively good topographical features for the inflow of compost generated from livestock farms. This keeps the bottom layer of the reservoir free of oxygen. Therefore, to prevent fish death due to insufficient DO in the reservoir, measures should be undertaken to limit the amount of livestock compost flowing into the reservoir within 0.3%, which has been experimentally determined. As a basic countermeasure, minerals such as limestone, dolomite, and magnesia containing calcium and magnesium should be added to the compost of livestock farms around the reservoir. These minerals have excellent pollutant removal capabilities when sprayed onto the compost. In addition, measures should be taken to prevent fish death according to the characteristics of each reservoir.

제올라이트 5A와 13X의 저농도 이산화탄소 흡착 및 탈착특성 (Adsorption and Desorption Characteristics of Carbon Dioxide at Low Concentration on Zeolite 5A and 13X)

  • 조영민;이지윤;권순박;박덕신;최진식;이주열
    • 한국대기환경학회지
    • /
    • 제27권2호
    • /
    • pp.191-200
    • /
    • 2011
  • A way to adsorptively remove indoor carbon dioxide at relatively lower concentration under ambient temperature was studied. A small lab-scale carbon dioxide adsorption and desorption reactors were prepared, and 5A and 13X zeolites were packed in this reactors to investigate their adsorption and desorption characteristics. The inflow carbon dioxide concentration was controlled to 5,000 ppm, relatively higher concentration found in indoor spaces with air quality problems, by diluting carbon dioxide with nitrogen gas. The flow rate was varied as 1~5 L/min, and the carbon dioxide concentration after this reactor was constantly monitored to examine the adsorption characteristics. It was found that 5A adsorbed more carbon dioxide than 13X. A lab-scale carbon dioxide desorption reactor was also prepared to investigate the desorption characteristics of zeolites, which is essential for the regeneration of used zeolites. The desorption temperature was varied as $25{\sim}200^{\circ}C$, and the desorption pressure was varied as 0.1~1.0 bar. Carbon dioxide desorbed better at higher temperature, and lower pressure. 5A could be regenerated more than three times by thermal desorption at $180^{\circ}C$. It is required to modify zeolites for higher adsorption and better regeneration performances.

Vertical Change in Extinction and Atmospheric Particle Size in the Boundary Layers over Beijing: Balloon-borne Measurement

  • Chen, Bin;Shi, Guang-Yu;Yamada, Maromu;Zhang, Dai-Zhou;Hayashi, Masahiko;Iwasaka, Yasunobu
    • Asian Journal of Atmospheric Environment
    • /
    • 제4권3호
    • /
    • pp.141-149
    • /
    • 2010
  • Aerosol size and number concentration were observed in the atmospheric boundary layer over Beijing (from near the ground to 1,200 m) on March 15 (a clear day) and 16 (a dusty day), 2005. The results were further compared with lidar measurements in order to understand the dependency of extinction on the particle size distribution and their vertical changes. The boundary layer atmosphere was composed of several sub-layers, and a dry air layer appeared between 400 and 1,000 m under the influence of dust event. In this dry air layer, the concentration of the fine-mode particles (diameter smaller than $1.0\;{\mu}m$) was slightly lower than the value on the clear day, while the concentration of coarse-mode particles (diameter larger than $1.0\;{\mu}m$) was remarkably higher than that on the clear day. This situation was attributed to the inflow of an air mass containing large amounts of Asian dust particles and a smaller amount of fine-mode particles. The results strongly suggest that the fine-mode particles affect light extinction even in the dusty atmosphere. However, quantitatively the relation between extinction and particle concentration is not satisfied under the dusty atmospheric conditions since laser beam attenuates in the atmosphere with high concentration of particles. Laser beam attenuation effect becomes larger in the relation between extinction and coarse particle content comparing the relation between extinction and fine particle content. To clarify this problem technically, future in situ measurements such as balloon-borne lidar are suggested. Here extinction was measured at 532 nm wavelength. Measurements of extinction at other wavelengths are desired in the future.

유입수 조건에 따른 인공습지 수질 정화효율 비교: 경안천 유역을 중심으로 (Comparison and Management of Water Purification Efficiency of Artificial Wetland according to Inflow Water Conditions: Focusing on the Gyeongancheon Basin)

  • 이설준;은범진;김종환;최이송;오종민
    • 생태와환경
    • /
    • 제57권1호
    • /
    • pp.28-38
    • /
    • 2024
  • 본 연구에서는 인공습지의 유입수 조건에 따른 수질정화 효율을 분석하기 위하여 하수처리수가 유입되는 2개 지점과 우수 유출수가 유입되는 1개 지점에 대해 정화효율을 비교하였다. 유입수 및 유출수 분석 결과와 제거효율을 검토한 결과, 하수처리수를 처리하는 2개 지점의 경우 T-N과 T-P 제거효율이 각각 54.7%, 77.4%로 산출되었으며 우수 유출수가 유입되는 1개 지점의 경우 SS 90.8%, BOD 51.1%, TOC 30.6%, T-N 38.8%, T-P 55.3%의 처리효율이 나타났다. 결과적으로 인공습지의 오염물질 제거효율은 유입수 농도에 비례하는 것으로 나타났으며, 효율적인 인공습지를 조성하기 위해서는 고농도 오염수에 대한 제거효율이 높았던 점을 고려하여 설계단계에서의 철저한 검토와 관리가 필요한 것으로 판단된다.

Electrokinetic 기술에 의한 점성토의 중금속 오염물 제거 (Removal of Heavy Metal Contaminants from Cohesive Soil by Electrokinetics)

  • 정하익;강병희
    • 한국지반공학회지:지반
    • /
    • 제13권6호
    • /
    • pp.123-138
    • /
    • 1997
  • 중금속으로 오염된 점성토의 정화에 대한 electrokinetic기술의 효율을 연구하기 위하여 포화 해성점토를 납으로 오염시켜 전기삼투시험을 수행하였다. 이를 위하여 실험조건으로서 납의 오염농도 500, 5,000, 50,000mg/kg, 공급전류 10, 50, 100mA, 가동시간 5, 15, 30일 및 3가지의 효율 향상기법을 적용하였다. 유입수와 유출수의 pH, 전기삼투유량 및 전기전도도를 시험중에 측정하고 또 시험 완료후에 공시체전 길이에 걸쳐 pH및 잔존 납농도를 측정하여 제시하였다. 시험결과에 의해서 electrokinetic 기술이 효과적인 방법이라는 결론을 얻었다. 또한 음극에 침강된 수산화납을 용해시키기위해 초산을 가하게 되면 정화효율이 향상된다는 사실을 알 수 있었다.

  • PDF

광양만 저질에서의 미량오염물질 분포특성에 관한 연구 (A Study on Distribution Property of Micropollutants in Gwang-Yang Bay Sediment)

  • 한상국;박지영
    • 한국환경과학회지
    • /
    • 제15권7호
    • /
    • pp.643-651
    • /
    • 2006
  • This study investigated the distributive property of micropollutants in sediment around Gwang-yang bay using simultaneous analytical method of 310 chemicals. In the results, the major micropollutants detected were CH type chemicals such as aliphatic, polycyclic compounds, benzenes, and CHN(O) type chemicals aromatic amines, and pesticides. Insecticides of pesticide type were frequently detected at all sampling site. The total concentration of micropollutants were higher in summer than in winter and measured within the range of $ND{\sim}36.50{\mu}g/L$. Also, because of effect of seomjin river, GY6 of all sampling site detected by the highest concentration, GY10 and 11 located in Gwang-yang outside bay were not detected the micropollutants. From the result of this study, we should estimated that the industrial complex located in Gwang-yang inside bay and an inflow of fresh water through the Seomjin river are major pollution sources of Gwang-yang bay.