In order to analyze the mechanism of semiconductor device damages by ESD, this paper adopts a new charged-device model(CDM), field-induced charged nudel(FCDM), simulator that is suitable for rapid routine testing of semiconductor devices and provides a fast and inexpensive test that faithfully represents ESD hazards in plants. The high voltage applied to the device under test is raised by the fie]d of non-contacting electrodes in the FCDM simulator. which avoids premature device stressing and permits a faster test cycle. Discharge current md time are measured and calculated The FCDM simulator places the device at a huh voltage without transferring charge to it, by using a non-contacting electrode. The only charge transfer in the FCMD simulator happens during the discharge. This paper examine the field charging mechanism, measure device thresholds, and analyze failure modes. The FCDM simulator provides a Int and inexpensive test that faithfully represents factory ESD hazards. The damaged devices obtained in the simulator are analyzed and evaluated by SEM Also the results in this paper can be used for to prevent semiconductor devices from ESD hazards.
On the study, The activated carbon assemblies(ACA) were prepared by activation of the coated glass mat(woven type) with phenolic resin at $700^{\circ}C$ under $N_2$ after drying and curing processes. Surface of the ACA was continuously modified with $N_2$, $CO_2$ or $NH_3$ at $700^{\circ}C$ for 2 hour for comparison of adsorptive characteristics between the ACA and commercial activated carbon cloth. The ACA showed high surface areas up to $2440\;m^2$/g when converted into the coated carbon base, and the surface was investigated by FT-IR and XPS. The basic ACA modified with $NH_3$ displayed the efficient removal capability of $SO_2$, which is 75% of that in commercial activated carbon cloth. Therefore, it has proved the applicability of ACA as an inexpensive materials for Dry de-SOX system.
Visarada, K.B.R.S.;Saikishore, N.;Kuriakose, S.V.;Rani, V. Shobha;Royer, M.;Rao, S.V.;Seetharama, N.
Plant Biotechnology Reports
/
v.2
no.1
/
pp.47-58
/
2008
To select agronomically useful transgenic plants, a large number of transgenic events are initially produced, gene transfer confirmed, and advanced to obtain homozygous lines for testing in field trials. Direct in planta assays for identifying the transgene carriers in the segregating progeny are based on the activity of selectable marker gene and are easy, simple and inexpensive. For this purpose, expression of bar gene as measured by tolerance to damage by glufosinate ammonium, the active ingredient in the herbicide BASTA, was investigated. Dose damage curves were generated by leaf paint tests with BASTA on four genotypes of sorghum. Transgenic plants were characterized in terms of sensitivity to the concentration of glufosinate ammonium. In transgenics, symptoms of BASTA swab tests at different growth stages and PCR analysis for cry1B were carried out and correlated. Germination tests could not be employed for large scale evaluation of transgenic progeny because of mortality of tolerant seedlings after transplantation to soil. Based on the above findings, a simple, inexpensive, time-saving, two-step scheme for effective evaluation of transgenics and their progeny containing bar gene as selection marker using BASTA swab tests is described.
Filter and microbalance sensitivity in measuring fine particulate matter mass is greatly influenced by particulate properties and environmental factors. Temperature and humidity control inside a measuring chamber with a microbalance, and neutralization of static charges on filters are essential for consistent filter weighing. Commercial weighing chambers are expensive with a unit price of tens of millions won. This study developed an inexpensive weighing chamber for weighing fine particulate matter and evaluatedits weighing performance. A microbalance with 1 ㎍ precision was used to measure the weight of a filter. The microbalance was set in a transparent acrylic enclosure (100 × 60 × 65 cm3) equipped with temperature and humidity control equipments. Weighing performance of the chamber was examined using Teflon filters with or without different particulate sample types. Temperature and humidity were maintained at approximately 23.2±1.2 ℃ and 36.2±1.8℃ for 8 days, respectively.
Fateh, Abolfazl;Aghasadeghi, Mohammad Reza;Keyvani, Hossein;Mollaie, Hamid Reza;Yari, Shamsi;Tasbiti, Ali Reza Hadizade;Ghazanfari, Morteza;Monavari, Seyed Hamid Reza
Asian Pacific Journal of Cancer Prevention
/
v.16
no.5
/
pp.1873-1880
/
2015
Background: A recent genome-wide association study (GWAS) on patients with chronic hepatitis C (CHC) treated with peginterferon and ribavirin (pegIFN-${\alpha}$/RBV) identified a single nucleotide polymorphism (SNP) on chromosome 19 (rs12979860) which was strongly associated with a sustained virological response (SVR). The aim of this study was twofold: to study the relationship between IL28B rs12979860 and sustained virological response (SVR) to pegIFN-${\alpha}$/RVB therapy among CHC patients and to detect the rs12979860 polymorphism by high resolution melting curve (HRM) assay as a simple, fast, sensitive, and inexpensive method. Materials and Methods: The study examined outcomes in 100 patients with chronic hepatitis C in 2 provinces of Iran from December 2011 to June 2013. Two methods were applied to detect IL28B polymorphisms: PCR-sequencing as a gold standard method and HRM as a simple, fast, sensitive, and inexpensive method. Results: The frequencies of IL28B rs12979860 CC, CT, and TT alleles in chronic hepatitis C genotype 1a patients were 10% (10/100), 35% (35/100), and 6% (6/100) and in genotype 3a were 13% (13/100), 31% (31/100), and 5% (5/100), respectively. In genotype 3a infected patients, rs12979860 (CC and CT alleles) and in genotype 1a infected patients (CC allele) were significantly associated with a sustained virological response (SVR). The SVR rates for CC, CT and TT (IL28B rs12979860) were 18%, 34% and 4%, respectively. Multiple logistic regression analysis identified two independent factors that were significantly associated with SVR: IL-28B genotype (rs 12979860 CC vs TT and CT; odds ratio [ORs], 7.86 and 4.084, respectively), and HCV subtype 1a (OR, 7.46). In the present study, an association between SVR rates and IL28B polymorphisms was observed. Conclusions: The HRM assay described herein is rapid, inexpensive, sensitive and accurate for detecting rs12979860 alleles in CHC patients. This method can be readily adopted by any molecular diagnostic laboratory with HRM capability and will be clinically beneficial in predicting treatment response in HCV genotype 1 and 3 infected patients. In addition, it was demonstrated that CC and CT alleles in HCV-3a and the CC allele in HCV-1a were significantly associated with response to pegIFN-${\alpha}$/RBV treatment. The present results may help identify subjects for whom the therapy might be successful.
Networking for manufacturing is gaining importance as a nerve system of computer-integrated manufacturing(CIM). Among the various network types, the most inexpensive type called fieldbus is specifically aimed to interconnect simple devices such as sensors and actuators. For this purpose, there are several choices of the protocol such as Profibus, FIP, Foundation Fieldbus, and IEC/ISA fieldbus. This paper presents the simulation results of Profibus and FIP. Both protocols has been simulated in order to evaluate the performance such as transmission delay and throughput under different protocol parameter setting and traffic conditions.
Journal of the Korean Institute of Telematics and Electronics
/
v.9
no.4
/
pp.17-24
/
1972
A simply constructed and inexpensive amplifier that exhibits unusually low noise is studied. The high-performance differential amplifier combines high input impedence, adjustable gain, low in put noise and low output impedance. The amplifier is particularly useful in applications which call for large amplificaions of very low level signals.
This paper proposed the vector controller of induction motors using one chip microprocessor. For developing a small and cheep speed control system, we use the one chip microprocessor 80C196MC. By using the one chip microprocessor we can make an inexpensive and small-sized vector controller for induction motors. We apply indirect vector control method and space vector modulation method to this system. The experimental results show that the proposed inverter has high performance features.
This paper deals with preventive replacements models for the item whose failures are dependent on their wear level. When measuring the item wear level is very costly, it may be economical to use substitutive characteristics that are correlated with the item wear level and relatively inexpensive to measure. In this paper, replacement policies based on such substitutive characteristics are proposed. The optimal level of substitutive characteristic to replace the item, which minimizes total cost, is obtained. Some numerical examples are also given.
The Journal of the Korean life insurance medical association
/
v.32
no.1
/
pp.15-20
/
2013
The exercise ECG test is a well-established, inexpensive, and non-invasive procedure for answering important clinical questions related to heart problems. The heart disease is directly led to mortality and serious issue to insurance medicine. Here is some evidence for interpretation of exercise ECG test results can determine prognosis of the heart disease.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.