• Title/Summary/Keyword: Industrial electricity usage

Search Result 26, Processing Time 0.027 seconds

Analysis of Domestic and Foreign Electricity Rates based on Electricity Usage Patterns of AMI applied Apartments (AMI 적용 아파트의 전기사용 패턴 기반 국내외 전기요금제 분석)

  • Koo, In-Seok;Lee, Sung-Hee;Sohn, Joong-Chan;Rhie, Dong-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.52-59
    • /
    • 2020
  • Currently, the domestic electricity rates for houses are charged by applying a progressive level according to monthly electricity usage. Electricity rates rise sharply wWhen the amount of electricity used is large, electricity rates rise sharply. The standardized electricity rate progressive system has limitations in that it lacks consideration of the consumers' power usage patterns and limits consumers' their options. Accordingly, the Ministry of Trade, Industry and Energy and the Korea Electric Power Corporation have been demonstrating the basis of a rate system for housing, which is a method of charging electricity according to the amount of electricity used by season and time. In this paper, 10 electricity usage patterns were derived through from AMI data analysis for 5 five years of 362 apartment complexes located in metropolitan cities. The patterns were, and then applied to the existing domestic electricity rate and time-by-time rates applied to demonstrations, and by time-by-time rates in the US and Australia. The effect of the optional rate by pattern was compared and analyzed. As a result, it was confirmed that benefits occurred in five5 patterns compared to existing rate plans, and the electricity rates increased in 5 five patterns, and t. This phenomenon shows the same phenomenon withis the same as the overseas rates, including domestic rates being demonstrated.

Temperature Effects on the Industrial Electricity Usage (산업별 전력수요의 기온효과 분석)

  • Kim, In-Moo;Lee, Yong-Ju;Lee, Sungro;Kim, Daeyong
    • Environmental and Resource Economics Review
    • /
    • v.25 no.2
    • /
    • pp.141-178
    • /
    • 2016
  • This paper, using AMR (Automatic Meter Reading) electricity data accurately measured in real time, analyses the characteristics and patterns of temperature effect on the industrial electricity usage. For this goal, the paper constructs and estimates a model which captures the properties of AMR time series including long-term trends, mid-term temperature effects, and short-term special day effects. Based on the estimated temperature response function and the temperature effect, we categorize the whole industry into two groups: one group with sharp temperature effect and the other with weak temperature effect. Furthermore, the industry group with sharp temperature effect is classified into a summer peak industry group and a winter peak industry group, based on the estimates of the temperature response function. These empirical results carry practical policy implications on the real time electricity demand management.

Study on TES system application for industrial production facility (축냉시스템의 산업용 생산설비 적용에 대한 고찰)

  • Park, C.H.;Hong, S.S.;Kim, J.R.;Park, S.S.;Hwang, H.S.
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1288-1293
    • /
    • 2009
  • The TES (Thermal Energy Storage) cooling system utilizing cheaper off-peak electricity has been applied just for building air-conditioning currently and causes limitation of usage rate and inefficiency of national resources utilization. In this regard, more says the necessity to apply TES system in industrial cooling system which is longer using period and wider usage. In this study, we will approve the technical and economical improvement in efficiency of industrial cooling system applied TES system by utilizing cheaper off-peak electricity and it will attribute the promotion of TES system and stabilization of supply and demand of electric power by proving the necessity to develop more efficient industrial cooling system by combining TES system.

  • PDF

Power Supply Considering load Characteristics and Eletricity Usage Pattern of Domestic Remote Islands (계통비연계 도서지역의 수요특성과 패턴분석에 따른 전력보급방안)

  • Jo, I.S.;Rhee, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.432-434
    • /
    • 2002
  • Recently, electricity demand of remote islands in Korea has been rapidly increased. It's mainly due to increase of income level resulted from economic development. Electricity demand patterns and characteristics in remote islands are different from those of mainland in point of time of peak load, demographic and industrial characteristics of islands, and so on. The optimal power supply in remote islands has a important relationship with accurate analysis of island's load characteristics, the adoption of relevant load forecasting technique, and optimal power facilities reflecting local's electricity demand characteristics. This paper shows the recent load pattern and characteristics, load forecasting using probability distribution, and the perpetration of relevant power facilities in remote islands.

  • PDF

Estimation of GHGs Emission to Improvement of Facility Efficiency in the Food wastewater Treatment Process (식품폐수처리시설의 설비효율 개선에 따른 온실가스 배출량 평가)

  • An, Sang-Hyung;Song, Jang-Heon;Kim, San;Chung, Jin-Do
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.378-384
    • /
    • 2019
  • In the food wastewater treatment facilities, the water quality improvement effect and the greenhouse gas emission amount followed by the change in electricity usage through a change of the aeration tank ventilation system were evaluated. also, the amount of greenhouse gas emission followed by the change in electricity usage through the change of the sludge dewatering, storage, transporting method was also evaluated. The total GHG emission from food wastewater treatment facility improvement were divided into direct emissions from the treatment processes and indirect ones from electricity usage. The water quality improvement effect of wastewater treatment plant was found to be 63.3% for BOD removal rate, 42.0% for COD removal rate, 71.0% for SS removal rate and 39.6% for T-N removal rate. and according to the results of calculating output by applying both direct emissions of greenhouse gas (Scope 1) and the indirect emission (Scope 2) of greenhouse gas followed by changes in power consumption. It was estimated that there was a total of 276.0tCO2eq./yr(7.5%) greenhouse gas reduction effect from 3,668.8tCO2eq./yr before improvement to 3,392.8tCO2eq./yr after improvement. In this result is not due to the effects of water quality improvement of emission source, but because the reduction in electricity use has reduced the amount of greenhouse gas emissions.

Analysis and Forecast of Electricity Usage of Industrial End-Uses (산업용 End-Use별 에너지사용 실태분석 및 예측)

  • 박종진;이창호
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1998.05a
    • /
    • pp.179-184
    • /
    • 1998
  • '90년대 이후 전기에너지의 효율적 이용에 따른 절약과 전력사용패턴의 개선을 목적으로 하는 수요관리 즉 DSM(Demand Side Management)의 중요성이 증대되고 있다. 하지만 전기소비량의 약 60%를 차지하는 산업용에 대해서는 전동기 보급율 조사, 냉방수요 행태 조사 및 조명기기 보급실태 조사와 같이 단일기기나 온도에 대한 조사 및 분석만이 이루어져 왔으며, 산업용 전체를 대상으로 업종별 End-Use별 사용실태 조사, 분석, 예측 등 체계적 분석이 이루어지지 않았다. (중략)

  • PDF

U-type Cross-Counter Indirect Evaporative Cooler made of Plastic/Paper (U형 직교 대향류 플라스틱/종이 재질 간접증발소자)

  • Kim, Nea-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.732-739
    • /
    • 2016
  • In Korea, the summer is hot and humid, and much electricity is consumed for air conditioning. Thus, the simultaneous usage of an indirect evaporative cooler and a common air conditioner could reduce the sensible heat and save electricity. This study developed a U-type cross-counter flow indirect evaporative cooler (IEC) made of plastic and paper. The efficiencies were compared with those of a cross-flow IEC. The specimen was $500mm{\times}500mm{\times}1000mm$. the results show that the indirect evaporation efficiencies of the cross-counter flow sample were 6-21% higher than those of the cross-flow sample. The pressure drops of the cross-counter sample were 51-66% higher. Thermal analysis based on the -NTU method predicted the experimental data within 10%. The electrical energy saved by the use of the cross-counter flow IEC was larger than that of the counter flow IEC, and the difference increases with the velocity. However, the the cross-counter IEC is two times larger than the cross-flow IEC, which may increase the material cost and water usage.

Power demand pattern analysis for electric appliances in residential and commercial building (주택 및 사무용 빌딩 내 전기기기의 전력 수요 패턴 분석)

  • Noh, Sung-Jun;Lee, Soon-Jeong;Lee, Sang-Woo;Kim, Kwang-Ho
    • Journal of Industrial Technology
    • /
    • v.30 no.A
    • /
    • pp.9-15
    • /
    • 2010
  • Recently, Smart Grid is a emerging topic in power and communication industry. Smart Grid refers to a evolution of the electricity supply infrastructure that monitors, protects, and intelligently optimize the operation of the interconnected elements including various type of generators, power grid, building/home automation system and end-use consumers. In order to successful implementation of Smart Grid, energy management function will be the key factor that coordinates and optimally controls the various loads according to the operating condition and environments, and the load patterns in residential and commercial building will be required as fundamental element for load management. In this study, we collects many types of energy usage data of electric appliances, analyze their load curves, and make the general load patterns for electrical appliance.

  • PDF

Solar ESS Peak-cut Simulation Model for Customer (수용가 대응용 태양광 ESS 피크컷(Peak-cut) 시뮬레이션 모델)

  • Park, Seong-Hyeon;Lee, Gi-Hyun;Chung, Myoung-Sug;Chae, U-ri;Lee, Joo-Yeuon
    • Journal of Digital Convergence
    • /
    • v.17 no.7
    • /
    • pp.131-138
    • /
    • 2019
  • The world's electricity production ratio is 40% for coal, 20% for natural gas, 16% for hydroelectric power, 15% for nuclear power and 6% for petroleum. Fossil fuels also cause serious problems in terms of price and supply because of the high concentration of resources on the earth. Solar energy is attracting attention as a next-generation eco-friendly energy that will replace fossil fuels with these problems. In this study, we test the charge-operation plan and the discharge operation plan for peak-cut operation by applying the maximum power demand reduction simulation. To do this, we selected the electricity usage from November to February, which has the largest amount of power usage, and applied charge / discharge logic. Simulation results show that the contract power decreases as the peak demand power after the ESS Peak-cut service is reduced to 50% of the peak-target power. As a result, the contract power reduction can reduce the basic power value of the customer and not only the economic superiority can be expected, but also contribute to the improvement of the electric quality and stabilization of the power supply system.

A Study on the Application Cases Analysis of ESS(Energy Storage System) to Electric Power System (에너지 저장 시스템의 전력계통 적용 사례 분석)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.1
    • /
    • pp.53-58
    • /
    • 2016
  • Because a progressive tax of home electricity rates is charged and a continuous rise of industrial electricity rates is expected in order to solve the global warming, the high oil prices and the serious power shortage problem, the efforts to apply the energy storage systems which can significantly improve the energy usage efficiency to the smart grid are trying newly. In this study, characteristics of the secondary battery which can be used as energy storage devices, the structure and operation principle of a lithium-ion battery, and the concept of energy storage systems are research and analyzed. In addition, in this paper, the base technologies which are required to apply to the energy storage system to electric power system are established by studying about installation location and application methodology of energy storage system to electric power system.