• 제목/요약/키워드: Industrial Wastewater

검색결과 800건 처리시간 0.021초

Estogenic and Dioxin-like Activity of Influent and Effluent of the Industrial Wastewater Treatment Plant

  • Oh, Seung-Min;Kim, Gi-Sur;Kim, Soung-Ho;Kim, Yun-Hee;Chung, Kyu-Hyuck
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 2002년도 추계국제학술대회
    • /
    • pp.166-166
    • /
    • 2002
  • The response of environmental pollutants can be detected bioanalytically focusing on the source and matrices of concern. Cell culture bioassays are rapid and inexpensive, and thus have great potential for determination of environmental pollution. We have examined the estrogenic and dioxin-like activites of industrial wastewater using E-screen assay and EROD microbioassay. Influent and effluent wastewater were collected from four different industrial wastewater treatment plants, such as cosmetics, paints, textile producing and metal coating plant, and extracted using solid-phase extraction with Oasis@HLB plus cartridge. Pollutants adsorbed to the cartridge were eluted with MTBE. MCF-7 cells were treated with extracts showed various estrogenic potential. The textile wastewater showed strong estrogenic activity and the others showed weak estrogenic activity, No effect was observed in the wastewater from paints producing plant. All extracts showed CYPIA inducing effects, indicating these samples contain dioxin-like chemicals. Bioanalytical results of effluents compared with influents could give us information about the incomplete wastewater treatment and biological potency caused by pollutants. [Supported by a Grant from the Korea Science and Engineering Foundation]

  • PDF

산업폐수 중의 질소 성분의 제거를 위한 고도처리 공정의 응용 (Application of Advanced Treatment Process for Nitrogen Compounds Removal of Industrial Waste-water)

  • 방성훈;임은태;정귀택;박재희;박석환;김성준;박돈희
    • KSBB Journal
    • /
    • 제23권6호
    • /
    • pp.541-545
    • /
    • 2008
  • This paper was studied to research regarding the removal of contained nitrogen in industrial wastewater which uses the A2O4 advanced water treatment process. The field researches of two companies' wastewater occurred in each wastewater treatment site to apply the A2O4 process system, it was observed them for 20 days. As a result of the A2O4 system advanced wastewater process which applied an altitude control process obtained $10{\sim}76\;mg/L$, and 20 mg/L total nitrogen compound concentration in the two wastewater plants. In conclusion, it applied the A2O4 system in the two companies' wastewater system.

공공하수처리시설에서 수질오염물질 유입 및 배출 특성 고찰 - 산업폐수 및 매립지 침출수 연계처리 시설을 중심으로 - (A study on characteristics of influent and effluent pollutants in public sewage treatment works combined with industrial wastewater and landfill leachate)

  • 정동환;조양석;안경희;김은석;김창수;정현미
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.673-682
    • /
    • 2016
  • In this study, we investigated influent and effluent water pollutants in 53 Public Sewage Treatment Works (PSTWs) where industrial wastewater or landfill leachate is combined four times for two years from 2014 to 2015. Also, we analyzed the characteristics of heavy metals and volatile organic carbons at influent and effluent of these PSTWs caused by sewage treatment combined with industrial wastewater or landfill leachate. As a result, six heavy metals such as barium, copper, iron, manganese, nickel and zinc, and four volatile organic carbons (VOCs) including phenols, di(2-)ethylhexyl phthalate (DEHP), formaldehyde and toluene were observed above detection limits in most of PSTWs. Also, it was revealed that six heavy metals such as hexavalent chromium, mercury, cadmium, chromium, nickel and selenium, and four VOCs including 1,1-dichloroethylene, vinyl chloride, naphthalene, and epichlorohydrin were observed more frequently according to precipitation. As a result of reviewing the monitoring data on "Water Quality Monitoring Networks" in lower watersheds of PSTWs, both heavy metals and VOCs were below detection limits, indicating that the effluent water had little influence on the watershed. Nevertheless for the better management of influent and effluent pollutants in PSTWs, it is necessary to establish the advanced management plans for water pollutants in PSTWs, which include a list of priority substances management, monitoring plans, and guidelines for industrial wastewater and landfill leachate combined in PSTWs.

하수처리장 운영의 최적화를 위한 ASM, PHOENICS의 적용 (Application of ASM and PHOENICS for Optimal Operation of Wastewater Treatment Plant)

  • 김준현;한미덕;한영한
    • 산업기술연구
    • /
    • 제20권A호
    • /
    • pp.73-82
    • /
    • 2000
  • This study was implemented to find an optimal model for wastewater treatment processes using PHOENICS(Parabolic, hyperbolic or Elliptic Numerical Integration Code Series) and ASM(Activated Sludge Model). PHOENICS is a general software based upon the laws of physics and chemistry which govern the motion of fluids, the stresses and strains in solids, heat flow, diffusion, and chemical reaction. The wastewater flow and removal efficiency of particle in two phase system of a grit chamber in wastewater treatment plant were analyzed to inquire the predictive aspect of the operational model. ASM was developed for a biokinetic model based upon material balance in complex activated sludge systems, which can demonstrate dynamic and spatial behavior of biological treatment system. This model was applied to aeration tank and settling chamber in Choonchun city, and the modeling result shows dynamic transport in aeration tank. PHOENCS and ASM could be contributed for the optimal operation of wastewater treatment plant.

  • PDF

농공단지 조성에 따른 하천 수질관리 대책에 관한 연구 (충청남도 지역을 중심으로) (A Study on the Control of Stream Water Pollution Caused by Construction of the Industrial Complex in Agricultural Area (Centering around Area of chung chong Nam Do))

  • 양천회
    • 한국안전학회지
    • /
    • 제9권1호
    • /
    • pp.155-160
    • /
    • 1994
  • A study of stream pollution caused by construction of the Industrial Complex in Agricultural Area of Chung Chong Nam Do were descrived here. The five main results of this studies are summerized. First, since 1988, among the companies moved in the industrial complex area, the number of electric and electronic companies have increased compared with food companies requiring much BOD. This Is very desirable to reduce the water pollution. Second, the average Biochemical Oxygen Demand(BOD) of Masan stream was the highest and it was decreased in the order of Yudug, Jo and Jungan stream. Third, although the concentration of heavy metals such as Cd and C $r^{6+}$ are not off the limit and the amount of it is small, it is desirable to introduce a chemical process to remove these metals. Fourth, since the wastewater from industrial complex area is the major factor in stream pollution, the laws associated with environmental protection should be enforced even then if the Industrial complex area with food and chemical companies produce wastewater less than 500ton/day. Fifth, it is required to improve a facilities which separete living wastewater from inderstrial wastewater In Kaya-gok and Nojang industrial complex areas.

  • PDF

세라믹담체를 이용한 페놀계 산업폐수의 생물학적 처리 (Biological Treatment of Phenolic Industrial Wastewater by a Mixed Culture Immobilized on Ceramic Beads)

  • 오희목;구영환;안극현;장갑용;고영희;권기석;윤병대
    • 한국미생물·생명공학회지
    • /
    • 제23권6호
    • /
    • pp.755-762
    • /
    • 1995
  • A phenolic resin industrial wastewater containing about 41,000 mg/l of phenol and 2,800 mg/l of formaldehyde was biologically treated by a mixed culture GE2 immobilized on ceramic beads. This study was carried out with three experimental groups : Control-only added the sludge of papermill wastewater ; GE2 treatment-added GE2 to Control ; Ceramic treatment-applied ceramic carrier to GE2 treatment. When the original wastewater was diluted 80 times with aerated tap-water, influent COD$_{Mn}$ WaS 1,140 mg/l and that of the effluent was in the range of 22-35 mg/l, which was not much different among the experimental groups. However, at 20-times dilution, influent COD$_{Mn}$ was 4,800 mg/l and the effluent COD$_{Mn}$ of Control, GE2 treatment and Ceramic treatment was 179, 128 and 94 mg/l, respectively. COD$_{Mn}$, removal efficiency by Ceramic treatment was the highest, at 98.0%. At this time, the effluent phenol concentration of Control, GE2 treatment and Ceramic treatment was 10.71, 7.93 and 5.60, respectively. As the dilution times decreased, the removal efficiency of COD$_{Mn}$ and phenol did not change much, but COD$_{Mn}$ and phenol concentration of the effluent increased. Consequently, it is likely that the phenolic industrial wastewater containing phenol and formaldehyde can be biologically treated using a GE2 and ceramic carrier and that at 40-times dilution, the effluent completely meets the effluent standards for industrial wastewater treatment plant.

  • PDF

교량 바닥판 보수공사에서 발생하는 콘크리트 폐수처리 방안 (Treatment of Concrete Wastewater in Repair of Bridge Deck)

  • 이봉학;최판길;김정기
    • 산업기술연구
    • /
    • 제28권A호
    • /
    • pp.125-132
    • /
    • 2008
  • As of 2003, construction waste has been produced at the level of 130,614.8 tons/day, in which the amount of waste concrete was 92,639.1 tons/day and accounted for about 66.4% of the amount of construction waste. Waste concrete is mainly produced in construction work and civil engineering work. Especially, road surface crushing method using a large amount of water requires thorough management of concrete wastewater. The aim of this study was to analyze water pollution due to concrete wastewater generated in repair of bridge deck using road surface crushing equipment and to suggest reasonable countermeasures for solve the problem. In this study, it was surveyed current conditions of produced concrete wastewater in bridge deck repair, analyzed physical features of concrete wastewater, expected effects of water pollution on inflow rivers if it is not treated, established treatment plan of water pollution by categories, and calculated capacity of each treatment process and required amount of necessary chemicals. As a result of sampling wastewater generated in field sites and testing it at a lab scale, it was revealed that the original wastewater was produced in removing concrete from bridge deck slabs using surface crushing equipment whose pH was 12.53, CODMn was 12.910mg/L, SS was 547.0mg/L, and other heavy metals were included in extremely small quantities.

  • PDF

MBT 폐수의 생분해성 평가 (Evaluation on the Biodegradability of the MBT Wastewater)

  • 임지영;박정환;김진한
    • 한국산학기술학회논문지
    • /
    • 제17권3호
    • /
    • pp.86-92
    • /
    • 2016
  • 본 연구는 가황촉진제 제조공정에서 발생되는 MBT 폐수의 생물학적 처리가능성을 평가하였다. MBT 폐수는 미생물 활동을 저하시키기 때문에 생물학적으로 처리가 불가능하였지만, 7일의 순응기간을 거쳐 약 10%의 COD가 제거되었다. MBT 폐수의 화학적 전처리를 위한 최적조건은 pH 3.5, 2시간동안 교반 후 $Fe^{3+}$를 주입하여 펜톤산화를 한 경우였다. 또한, 펜톤처리 된 MBT 폐수를 제지폐수와 혼합하여 활성슬러지공정에서 처리했을 경우 MBT 폐수의 COD가 약 20% 제거되었다.

화학적 폐수처리 중 GC/MS에 의한 폐놀생성 규명에 관한 연구 (A Study on the Identification of Phenol Production by GC/MS under Chemical Treatment of Industrial Wastewater)

  • 박선구;고오석;신대윤
    • 한국환경과학회지
    • /
    • 제9권1호
    • /
    • pp.89-93
    • /
    • 2000
  • Twenty organic chemical substances(Table 2) were isolated from untreated wastewater, as well as treated wastewater, collected at 76 companys of 9 industry group located in the basin of Youngsan River. Those organic compounds were analyzed by Gas Chromatography/Mass Spectrometry(GC/MS) and confirmed through comparison with each standard reagents. Phenol, which was not detected in the raw wastewater, was identified in the effluent of treatment facility, indicating that phenol is generated from isopropylbenzene of plant wastewater.

  • PDF

처리기술에 근거한 산업폐수 배출허용기준 국내 적용성 연구(II) : 산업폐수 위해성 지표를 이용한 오염부하 기여도 분석 (Assessment of Technology Based Industrial Wastewater Effluent Limitation and Standards for the Application of Domestic Industries (II) : Analysis Pollution Loads Contribution by Risk Assessment Indicator in Industrial Wastewater)

  • 김경진;김원기;정상구;정진영;김재훈;김상훈;염익태
    • 한국물환경학회지
    • /
    • 제26권2호
    • /
    • pp.191-199
    • /
    • 2010
  • Introduction of Technology-Based Effluent Limitations (TBELs) concepts into Korea requires extensive and through analyses on the expected pollutants reduction effects and the cost factor for the industry side. In addition, the TEBLs should be optimized for the regulatory environments of Korea and be applied in a progressive manner to minimize the undesirable effects. It is also necessary to assess the contribution of each industrial categories's to the pollution of natural water bodies to find the priority of TEBLs application. For these purposes, the pollution loads of various industrial categories were analyzed using risk assessment indicator based on Toxic Weighting Factors (TWFs). First, the TWFs were calculated for the pollutants regulated using the method adopted by USEPA. And the effluent characteristics of the eighty two categories of industry in Korea were investigated. Although the analytical data on the wastewater from different industrial categories are relatively limited, the results from two previous studies were used. The first study, conducted by the National Institute of Environmental Research in 2001~2004, investigated the wastewater characteristics from 255 industrial sources covering the major 20 industrial categories. The second study includes more recent analytical data for the wastewater from 500 industrial sources, covering all the 82 industrial categories. In the result of the pollution loads analyses, the category of 'Synthetic and Chemical manufacture' was found to show the highest raw pollution load. On the other hand the category of 'Ion & Steel manufacture' was found to show the highest effluent pollution loads, which can be considered as the real impacts on natural water streams. The top five categories occupied 62.2% of the total effluent pollution loads. Through the analyses, the relative importances of each industrial categories and the priorities of TEBL-based pollution reduction were determined.