• 제목/요약/키워드: Industrial SPECT

검색결과 11건 처리시간 0.019초

공정 내 기포가 산업용 SPECT의 성능에 미치는 영향 (Influence of Void on Performance of Industrial SPECT System)

  • 박장근;정성희;김종범;문진호;김찬형
    • 방사선산업학회지
    • /
    • 제8권1호
    • /
    • pp.23-27
    • /
    • 2014
  • Industrial single photon emission computed tomography (SPECT) is an useful technique to investigate the dynamic behavior of process flow. In the present study, to evaluate the influence of a void on the performance of industrial SPECT, industrial SPECT with various radioisotope sources and gas holdups was modeled by the Monte Carlo simulation. The results are very encouraging; that is, the void little influences the performance of industrial SPECT, which means that industrial SPECT could be a suitable tool to investigate the dynamic characteristics of the flow in a water-air phase process.

방사성동위원소 위치에 따른 산업용 SPECT 성능에 미치는 영향 (Effect of Radioisotope Position on Performance of Industrial SPECT)

  • 문진호;김종범;정성희
    • 방사선산업학회지
    • /
    • 제6권3호
    • /
    • pp.245-249
    • /
    • 2012
  • Demand of fluid flow visualization has increased in industrial processes, because medical imaging technology is highly developed. As a part of the industrial process imaging technology, industrial single photon emission computed tomography (SPECT) system was developed to measure the cross-sectional distribution of the process fluid. The SPECT consists of 36 NaI (Tl) detectors with the hexagonal configuration. Reconstructed images were acquired for various positions of radioactive source to estimate SPECT device performance. To evaluate the reliability of the experimental results, the Monte Carlo simulation results are compared with experimental results. In general, the experimental and simulation results were consistent. However, as the source position was getting far from the center of the reactor, the accuracy of reconstructed images was compromised. It seems to be due to the inconsistent spatial resolution of the collimators according to the source position.

산업용 SPECT의 검출기 개수가 영상 해상도에 미치는 영향 평가 (Effect of the Number of Detectors on Performance of Industrial SPECT)

  • 박장근;김찬형;김종범;문진호;정성희
    • 방사선산업학회지
    • /
    • 제5권4호
    • /
    • pp.325-330
    • /
    • 2011
  • To predict the details of flow in industrial process unit, single photon emission computed tomography (SPECT) is a promising technique. Recently, industrial SPECT based on medical system has developed by researchers of the Korea Atomic Energy Research Institute (KAERI) and Hanyang University. In the present study, to confirm the effect of the number of detectors on image quality, and determine the optimal number of detectors in industrial SPECT, industrial SPECT system with various geometries were evaluated by the Monte Carlo simulation. CsI(Tl) detectors ($12mm{\times}12mm{\times}20mm$) with collimators (the geometric resolution of collimator $R_g$ was 4 cm at the center of the 30 cm diameter cylindrical vessel object) were modeled in a hexagonal array, and the point sources of $^{99m}Tc$, $^{68}Ga$, and $^{137}Cs$ were simulated at the center of the cylindrical vessel object using the MCNPX code. Then, the reconstruction images of each geometry were reconstructed using the expectation maximization (EM) algorithm. In this study, the reciprocity theorem was used to improve computation time required for system matrix of the EM algorithm. The result shows that the resolution of the reconstructed image was significantly improved by increasing the number of detectors in industrial SPECT system and more than 60 detectors will be required for the resolution of the reconstructed image.

SPECT 심근영상의 영상분할을 이용한 3차원 재구성 (3D Reconstruction Using Segmentation of Myocardial SPECT)

  • 정재은;이준행;최석윤;이상복
    • 한국산학기술학회논문지
    • /
    • 제11권6호
    • /
    • pp.2240-2245
    • /
    • 2010
  • 심근영상의 SPECT(Single Photon Emission Computed tomography)검사는 감마선을 방출하는 방사성의약품을 환자에게 정맥주사한 후 이 의약품이 심장에 고루 퍼지면 관심부위를 촬영하여 질병으로 인한 변화를 컴퓨터를 이용하여 진단하는 검사법이다. 기능적인 정보를 담고 있는 심근관류 영상은 비침습적인 심근질환 검사에 유용한 방법이지만, 물리적 인자들에 의해 잡음과 낮은 해상도는 판도하는데 어려움을 주게 된다. 본 논문은 심근영상을 레벨 셋 알고리즘을 이용하여 영상을 분할하고 분할된 영역을 3차원으로 구현하여 판독에 도움을 주는 방안을 제안하였다. 판독의 어려움을 해결하기 위하여 레벨 셋을 이용하여 관심부위인 좌심실 영역을 분할하였고 분할된 영역을 3차원영상으로 모델링 하였다.

시준기의 특성으로 인한 SPECT 왜곡 화상의 보정 (Correction of Single Photon Emission CT Image Distorted by Collimator Characteristic)

  • 백승권
    • 융합신호처리학회논문지
    • /
    • 제5권1호
    • /
    • pp.18-24
    • /
    • 2004
  • Single Photon Emission CT(SPECT)기술은 산업의 비접촉 계측 시스템 분야에 있어서 단층 영상을 얻는데 이용되고 있다. 재구성된 영상의 화질이 왜곡되는 문제점의 하나는 시준기 특성에 있다. 영상 왜곡은 시준기의 기하학적 구조에 원인이 있다. 본 논문은 시준기의 구조로 인한 영상 왜곡을 제거하는 보정법을 제시하고 기존의 보정법과 비교하였다. 보정법은 투영 데이터를 공간 주파수상에서 위치 의존적 왜곡 함수로 디콘볼루션 하여 영상 왜곡을 제거하였다. 본 논문에서 시준기의 각도, 검출기와 물체 중심의 거리에 대하여 시뮬레이션을 하고, 실험을 통하여 검증하였다. 실제산업에서의 응용을 고려하여 보정법의 유효성 및 한계를 검토하였다.

  • PDF

정상 뇌혈류 영상에서 재구성 알고리즘 적용에 따른 섭취율 차이 : 통계적 파라미터 지도를 사용한 분석 (The changes of cerebral blood flow by brain imaging algorithm in the Normal Brains : Analysis by Statistical Parametric Mapping)

  • 이효영;김윤진;신성규
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5311-5316
    • /
    • 2012
  • 뇌 영상분석 알고리즘 적용에 따른 뇌혈류의 변화를 관찰하기 위해 정상 성인 13명(평균연령 39세)을 대상으로 뇌혈류 단 광자 단층촬영(Single Photon Emission Computed Tomography, SPECT)을 시행하였다. 획득된 영상을 여과후 역투영법(Filtered Back Projection, FBP)과 반복적 방법(Ordered Subset Expectation Maximization, OSEM)으로 영상을 재구성하여 통계학적 파라미터 뇌지도법으로 비교하여 방사성 의약품의 뇌 분포양상을 확인하였으며, 혈류의 변화는 크러스트(Cluster)로 표현시켰다. 이에 대한 결과로는 여과후 역투영법이 반복적 방법보다 섭취가 증가된 부위는 우측 전두엽, 대뇌회전하부, 외핵, 좌측대뇌 변엽과 대상이랑이며, 섭취가 감소된 부위는 좌측전두엽, 중간전두이랑, 하측전두이랑, 중심전이랑, 하측전두이랑, 중심전이랑이었다. 이는 영상재구성시 적용되는 알고리즘에 따라 뇌 혈류분포가 다르게 나타난 것을 크러스트(Cluster)로 표현시켰고, 명확한 시각적 표시가 가능하도록 뇌 확룔 지도로 보여주는데 의의가 있다.

Physicochyemical Properties of $ZrF_4-Based$ Fluoride Glasses Containing Rare-Earth Ions

  • Ishioka, Noriyuki;Ogawa, Kouji;Arakawa, Tsuyoshi
    • The Korean Journal of Ceramics
    • /
    • 제5권4호
    • /
    • pp.375-378
    • /
    • 1999
  • In tho XRD study of $56ZrF_4 \cdot34BaF_2 \cdot4AIF_3 \cdot(6-x)LaF_3 \cdotxLnF_3$ glassdLn=Ce, Nd, Gd, Th), halo pattern charactarktic fo an amorphous sample appeared. When the halo peak angle ($\theta_p$) was converted into a wavenumber with $Qp=4\pi sinG\pi/\lambda(\lambda$ is the wavolongth of the radialion used), it was found that the Qp values varied almost liuearly with the concentration 01 $LnF_3$. The emissiou spect1.a of $Ce^{3-}$-containing fluoride glasses nnder 273 nm excitation had a peak maximum at ea. 300 nm $(Ce^{3+}$ 5d-4f- transition). The maximal intensity of the fluorescence was observed when the $CeF_3$, content was extremely low (ca. 1 mol%j. DTA measurement revealed tbat these fluoride glasses had two crystallization temperatures. In $56ZrF_4. 34BaF_2. 4NF_3. (6-x)LaF_3 .xNdF_3$ glasses, the actmation energies of crystallization obtained from a Kssinger plot were 1.7 and 5.0 eV for the glass with x=2, and 1.9 and 5.6 eV for the glass with x=4.

  • PDF

Inverse Electron-demand Diels-Alder 반응을 이용한 핵의학 영상 프로브의 합성 및 활용 (Synthesis of PET and SPECT Radiotracers Using Inverse Electron-demand Diels-Alder Reaction)

  • ;전종호
    • 공업화학
    • /
    • 제28권2호
    • /
    • pp.141-152
    • /
    • 2017
  • 1,2,4,5-테트라진 유도체를 이용한 inverse electron-demand Diels-Alder (IEDDA) 반응은 다양한 생체물질, 고분자, 나노 물질 복합체의 효율적인 합성에 폭넓게 활용되고 있다. IEDDA는 유기용매에서뿐만 아니라 생리학적 조건 하에서도 매우 특이적이며 빠른 반응속도를 가지고 있는 것으로 알려져 있다. 이러한 특성으로 인해 본 반응은 다양한 생물학적 활성을 가지는 물질의 방사성동위원소 표지와 분자영상 및 질병 치료를 위한 방사성의약품 개발에도 활발히 응용되고 있다. 본 리뷰 논문은 IEDDA 반응을 방사화학 및 핵의학 분야에서 이용한 최근 연구 동향 및 연구 결과 그리고 향후 전망에 대해 소개하고자 한다.

핵의학 투고 논문 분류 및 방향성 고찰 (Classification of submitted nuclear medicine dissertation and directional consideration)

  • 조호연;우영란;서강록;홍건철
    • 핵의학기술
    • /
    • 제26권2호
    • /
    • pp.37-42
    • /
    • 2022
  • Purpose Since 1985, the Korean society of nuclear medicine technology (KSNMT) has been engaged in academic activities related to nuclear medicine imaging. From 2017 to 2021, the papers published in the journal were classified by the specific fields to examine the trends in the research and the direction of nuclear medicine in comparison with the papers submitted to the Korean Society of Nuclear Medicine (KSNM) during the same period. Materials and Methods From 2017 to 2021, papers submitted to KSNMT and KSNM were classified and databaseization using the Excel program by submission type, examination equipment, and examination field. Through this data, the number of papers published in journals by year, the number of papers submitted by detailed fields, and key words by era were analyzed and compared. Results The papers included by journal was 57 KSNMT and 280 KSNM. The major large classification of equipment, PET, Planar and SPECT was 26.3%, 21.1%, 19.3% in the KSNMT, KSNM was 49.6%, 6.4%, and 9.3%, with 66.7% and 65.3%, respectively. the major medium classification of equipment, industrial safety, urogenital system, nervous system, and quality control accounted for 54.4% of the total papers of the total ratio in the KSNMT, while the medium classification of oncology, endocrine system, urogenital system, therapy, and nervous system accounted for 61.1% of KSNM. In the major small classification of image acquisition, improvement effect, and exposure management accounted for 70.2% in KSNMT, while the items of image acquisition, report, and improvement effect accounted for 60.7% in KSNM. The major keywords except for equipment-related keywords such as PET/CT, PET/MR, and SPECT were SUV, Planar Image, and Respiration Gating Method in KSNMT and Ga68, Thyroid, and Lymphoma in the KSNM. Conclusion When checking the last 5 years of submissions, we can see that KSNMT is mainly concerned with image acquisition using existing radiotracers, while KSNM has focused on new radiotracers such as 68Ga, 177Lu, etc., and new medical technologies of theranostic. It has been confirmed that more PET-related papers than other examination equipment will account for a greater number of papers, and it is believed that future submissions will also account for a higher proportion of PET-related papers than other equipment.

대한핵의학기술학회 투고 논문 분류 (Classification of submitted KSNMT dissertation)

  • 한동찬;이혁;홍건철;안병호;최성욱
    • 핵의학기술
    • /
    • 제21권1호
    • /
    • pp.65-69
    • /
    • 2017
  • 1977년 첫걸음을 시작한 대한핵의학기술학회의 영상관련 학술활동은 1985년 창간호를 발간하며 비로소 학회지의 형식을 갖추게 되었다. 지금까지 학회지에 게재된 방사분과 논문을 세부분야 별로 분류하여 연구논문의 동향을 알아보고자 한다. 1985년부터 2016년 상반기까지 학회지에 수록된 논문을 제출형식 별, 검사장비 별, 검사분야 별로 분류하고 엑셀(Microsoft Office 2010)프로그램을 이용하여 데이터베이스화 하였다. 이 자료를 통해 각 연도별 학회지 게재 논문 수, 세부분야별(detail) 제출 논문 수, 그리고 시대별 핵심어(keyword) 분포 등을 분석하였다. 학회지에 게재된 논문은 방사분과 1151편, 방사분과와 임상분과 두 분과의 공통주제 28편이였다. 방사분과 연대별 게재 논문 수는 1980년대 46, 1990년대 149, 2000년대 467, 2010~2016년 상반기까지 517편이였다. 제출형식별 논문 수는 원저 571, 초록 529, 심포지움 31, 특강25, 종설 11, 흥미영상 7, 포스터 3, 증례보고 2편이였다. 이중 심포지움과 특강 56편을 제외한 논문에서 검사장비 별 논문 수는 PET 319, Planar 302, SPECT 172, 방사성의약품 113, 방호 및 안전관리 103, 골밀도 28, 기타 86편이였다. 검사분야별 논문 수는 종양학 201, 장비 179, 심혈관 및 순환계 102, 환경안전 82, 골격계 76, 신경 핵의학 66, 정도관리 61, 비뇨 생식기계 56, 내분비계 49, 소화기계 44, 치료 34, 산업안전 24, 분자영상 15, 감염 및 염증 9, 호흡기계 9, 소아 핵의학 8, 기타 108편 이였다. 시대별 가장 많이 기재된 키워드(keyword)는 1999~2005년 PET, 2006~2016년 PET/CT였다. 보다 다양한 분야의 논문제출을 권장하기 위해서 대한핵의학기술학회에 게재된 논문뿐만 아니라 다양한 형태의 자료들을 데이터베이스화 하는 과정이 필요 할 것이다. 또한 많은 회원들이 영향력지표(Impact factor)가 높은 논문을 발표 할 수 있도록 대한핵의학기술학회 홈페이지를 통한 빅 데이터 자료제공 등과 같은 학회차원의 기술적, 제도적 보완과 함께 연구자 개인의 지속적인 노력과 다 기관 간의 협력하는 노력이 필요 할 것이다.

  • PDF