• Title/Summary/Keyword: Industrial SPECT

Search Result 11, Processing Time 0.034 seconds

Influence of Void on Performance of Industrial SPECT System (공정 내 기포가 산업용 SPECT의 성능에 미치는 영향)

  • Park, Jang Guen;Jung, Sung-Hee;Kim, Jong Bum;Moon, Jinho;Kim, Chan Hyeong
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.23-27
    • /
    • 2014
  • Industrial single photon emission computed tomography (SPECT) is an useful technique to investigate the dynamic behavior of process flow. In the present study, to evaluate the influence of a void on the performance of industrial SPECT, industrial SPECT with various radioisotope sources and gas holdups was modeled by the Monte Carlo simulation. The results are very encouraging; that is, the void little influences the performance of industrial SPECT, which means that industrial SPECT could be a suitable tool to investigate the dynamic characteristics of the flow in a water-air phase process.

Effect of Radioisotope Position on Performance of Industrial SPECT (방사성동위원소 위치에 따른 산업용 SPECT 성능에 미치는 영향)

  • Moon, Jinho;Kim, Jongbum;Jung, Sung-Hee
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.245-249
    • /
    • 2012
  • Demand of fluid flow visualization has increased in industrial processes, because medical imaging technology is highly developed. As a part of the industrial process imaging technology, industrial single photon emission computed tomography (SPECT) system was developed to measure the cross-sectional distribution of the process fluid. The SPECT consists of 36 NaI (Tl) detectors with the hexagonal configuration. Reconstructed images were acquired for various positions of radioactive source to estimate SPECT device performance. To evaluate the reliability of the experimental results, the Monte Carlo simulation results are compared with experimental results. In general, the experimental and simulation results were consistent. However, as the source position was getting far from the center of the reactor, the accuracy of reconstructed images was compromised. It seems to be due to the inconsistent spatial resolution of the collimators according to the source position.

Effect of the Number of Detectors on Performance of Industrial SPECT (산업용 SPECT의 검출기 개수가 영상 해상도에 미치는 영향 평가)

  • Park, Jang Guen;Kim, Chan Hyeong;Kim, Jong Bum;Moon, Jinho;Jung, Sung-Hee
    • Journal of Radiation Industry
    • /
    • v.5 no.4
    • /
    • pp.325-330
    • /
    • 2011
  • To predict the details of flow in industrial process unit, single photon emission computed tomography (SPECT) is a promising technique. Recently, industrial SPECT based on medical system has developed by researchers of the Korea Atomic Energy Research Institute (KAERI) and Hanyang University. In the present study, to confirm the effect of the number of detectors on image quality, and determine the optimal number of detectors in industrial SPECT, industrial SPECT system with various geometries were evaluated by the Monte Carlo simulation. CsI(Tl) detectors ($12mm{\times}12mm{\times}20mm$) with collimators (the geometric resolution of collimator $R_g$ was 4 cm at the center of the 30 cm diameter cylindrical vessel object) were modeled in a hexagonal array, and the point sources of $^{99m}Tc$, $^{68}Ga$, and $^{137}Cs$ were simulated at the center of the cylindrical vessel object using the MCNPX code. Then, the reconstruction images of each geometry were reconstructed using the expectation maximization (EM) algorithm. In this study, the reciprocity theorem was used to improve computation time required for system matrix of the EM algorithm. The result shows that the resolution of the reconstructed image was significantly improved by increasing the number of detectors in industrial SPECT system and more than 60 detectors will be required for the resolution of the reconstructed image.

3D Reconstruction Using Segmentation of Myocardial SPECT (SPECT 심근영상의 영상분할을 이용한 3차원 재구성)

  • Jung, Jae-Eun;Lee, Jun-Haeng;Choi, Seok-Yoon;Lee, Sang-Bock
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.2240-2245
    • /
    • 2010
  • Myocardial imaging in SPECT (Single Photon Emission Computed tomography) scan of the gamma-ray emitting radiopharmaceuticals to patients after intravenous radiopharmaceuticals evenly spread in the heart region of interest by recording changes in the disease caused by a computer using the PSA test is to diagnose. Containing information on the functional myocardial perfusion imaging is a useful way to examine non-invasive heart disease, but the argument by noise and low resolution of the physical landscape that is difficult to give. For this paper, the level of myocardial imaging by using the three algorithms to split the video into 3-D implementation of the partitioned area to help you read the proposed plan. To solve the difficulty of reading level, interest in using the sheet set, partitioned area of the left ventricle was ranked the partitioned area was modeled as a 3-D images.

Correction of Single Photon Emission CT Image Distorted by Collimator Characteristic (시준기의 특성으로 인한 SPECT 왜곡 화상의 보정)

  • 백승권
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.1
    • /
    • pp.18-24
    • /
    • 2004
  • SPECT technology is used for the reconstructed image in the field of industry noncontact measurement system. One of the distortion problems in reconstructed image quality is a collimator characterictic. The image distortion is caused by a geometrical structure of the collimator. This paper indicated a correction method to remove the image distortion by the structure of the collimator, and compared with the existing correction method. The correction. method removed the image distortion to use deconvolution of projection data with the shift-variant blurring function in the frequency domain. In this pater, I simulated with the collimator angle and distance between the detector and the center of object. and verified with expeimental data. The validity and limitation of correction method is studied for actual industrial applications.

  • PDF

The changes of cerebral blood flow by brain imaging algorithm in the Normal Brains : Analysis by Statistical Parametric Mapping (정상 뇌혈류 영상에서 재구성 알고리즘 적용에 따른 섭취율 차이 : 통계적 파라미터 지도를 사용한 분석)

  • Lee, Hyo-Yeong;Kim, Yun-Jin;Sin, Sung-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5311-5316
    • /
    • 2012
  • Single Photon Emission Computed tomography(SPECT) was performed on 13 healthy adults (average age: 39) to investigate the changes of cerebral blood flow according to brain imaging analysis algorithm. The acquired images were filtered and reconstructed through Filtered Back Projection (FBP) and Ordered Subset Expectation Maximization (OSEM). The brain distribution data of radiopharmaceuticals were compared using Statistical Parametric Mapping (SPM), and the changes of blood flow was expressed in Cluster. As a result, uptake rate was increased in Sub-gyral, Sub-Lobar, Extra-Nuclear, Limbic lobe and Cingulate Gyrus, while uptake rate was decreased in Middle frontal gyrus, Inferior Frontal Gyrus and Precentral Gyrus. The discriminable SPM was shown according to cerebral blood flows in Cluster by the reconstruction algorithm.

Physicochyemical Properties of $ZrF_4-Based$ Fluoride Glasses Containing Rare-Earth Ions

  • Ishioka, Noriyuki;Ogawa, Kouji;Arakawa, Tsuyoshi
    • The Korean Journal of Ceramics
    • /
    • v.5 no.4
    • /
    • pp.375-378
    • /
    • 1999
  • In tho XRD study of $56ZrF_4 \cdot34BaF_2 \cdot4AIF_3 \cdot(6-x)LaF_3 \cdotxLnF_3$ glassdLn=Ce, Nd, Gd, Th), halo pattern charactarktic fo an amorphous sample appeared. When the halo peak angle ($\theta_p$) was converted into a wavenumber with $Qp=4\pi sinG\pi/\lambda(\lambda$ is the wavolongth of the radialion used), it was found that the Qp values varied almost liuearly with the concentration 01 $LnF_3$. The emissiou spect1.a of $Ce^{3-}$-containing fluoride glasses nnder 273 nm excitation had a peak maximum at ea. 300 nm $(Ce^{3+}$ 5d-4f- transition). The maximal intensity of the fluorescence was observed when the $CeF_3$, content was extremely low (ca. 1 mol%j. DTA measurement revealed tbat these fluoride glasses had two crystallization temperatures. In $56ZrF_4. 34BaF_2. 4NF_3. (6-x)LaF_3 .xNdF_3$ glasses, the actmation energies of crystallization obtained from a Kssinger plot were 1.7 and 5.0 eV for the glass with x=2, and 1.9 and 5.6 eV for the glass with x=4.

  • PDF

Synthesis of PET and SPECT Radiotracers Using Inverse Electron-demand Diels-Alder Reaction (Inverse Electron-demand Diels-Alder 반응을 이용한 핵의학 영상 프로브의 합성 및 활용)

  • Mushtaq, Sajid;Jeon, Jongho
    • Applied Chemistry for Engineering
    • /
    • v.28 no.2
    • /
    • pp.141-152
    • /
    • 2017
  • Inverse electron-demand Diels-Alder reactions (IEDDA) between tetrazine derivatives and strained dienophiles have attracted a lot of attention for the efficient conjugation of biomolecules, polymers, and nanomaterials. Excellent specificity, exceptionally fast reaction rate, and biocompatibility are key features of IEDDA. Therefore, it has also been applied to the development of new labeling methods using several radioisotopes and development of radiotracers to carry out various nuclear imaging as well as therapeutic studies. The purpose of this review is to introduce the reader to the recent advances and applications of IEDDA in the fields of radiochemistry and nuclear medicine.

Classification of submitted nuclear medicine dissertation and directional consideration (핵의학 투고 논문 분류 및 방향성 고찰)

  • Ho-Yeon, Cho;Yeong-Ran, Woo;Kang-Rok, Seo;Gun-Chul, Hong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2022
  • Purpose Since 1985, the Korean society of nuclear medicine technology (KSNMT) has been engaged in academic activities related to nuclear medicine imaging. From 2017 to 2021, the papers published in the journal were classified by the specific fields to examine the trends in the research and the direction of nuclear medicine in comparison with the papers submitted to the Korean Society of Nuclear Medicine (KSNM) during the same period. Materials and Methods From 2017 to 2021, papers submitted to KSNMT and KSNM were classified and databaseization using the Excel program by submission type, examination equipment, and examination field. Through this data, the number of papers published in journals by year, the number of papers submitted by detailed fields, and key words by era were analyzed and compared. Results The papers included by journal was 57 KSNMT and 280 KSNM. The major large classification of equipment, PET, Planar and SPECT was 26.3%, 21.1%, 19.3% in the KSNMT, KSNM was 49.6%, 6.4%, and 9.3%, with 66.7% and 65.3%, respectively. the major medium classification of equipment, industrial safety, urogenital system, nervous system, and quality control accounted for 54.4% of the total papers of the total ratio in the KSNMT, while the medium classification of oncology, endocrine system, urogenital system, therapy, and nervous system accounted for 61.1% of KSNM. In the major small classification of image acquisition, improvement effect, and exposure management accounted for 70.2% in KSNMT, while the items of image acquisition, report, and improvement effect accounted for 60.7% in KSNM. The major keywords except for equipment-related keywords such as PET/CT, PET/MR, and SPECT were SUV, Planar Image, and Respiration Gating Method in KSNMT and Ga68, Thyroid, and Lymphoma in the KSNM. Conclusion When checking the last 5 years of submissions, we can see that KSNMT is mainly concerned with image acquisition using existing radiotracers, while KSNM has focused on new radiotracers such as 68Ga, 177Lu, etc., and new medical technologies of theranostic. It has been confirmed that more PET-related papers than other examination equipment will account for a greater number of papers, and it is believed that future submissions will also account for a higher proportion of PET-related papers than other equipment.

Classification of submitted KSNMT dissertation (대한핵의학기술학회 투고 논문 분류)

  • Han, Dong-Chan;Lee, Hyuk;Hong, Gun-Chul;Ahn, Byeong-Ho;Choi, Seong-Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.65-69
    • /
    • 2017
  • Purpose KSNMT(Korea Society of Nuclear Medicine Technology) stepping first step in 1997, has published first journal related with nuclear medicine technology in 1985. With classifying In Vivo Session Dissertation reported in the entire journal, trend of the Dissertation will be studied. Materials and Methods Dissertations which published from 1985 to first half of 2016 in the journal are classified with presentation form and with scanner, And all the data is organized with Excel program. Through the data, the number of dissertations published in each year, the number of dissertation published in details, and keyword distributions in each period are analyzed. Results The number of In-vivo section dissertations was 1151 and the number of In-vivo section dissertations that have common subject with In-vitro section was 28. The number of In-vivo section dissertation in 1980s was 46, in 1990s was 149, in 2000 was 467 and from 2010 to the first half of 2016 was 517. The number of dissertation with original articles was 571, with abstract was 529, with symposium was 31, with special lecture was 25, with review was 11, with interesting image was 7, with poster was 3 and with case report was 2. With symposium and special lecture excluded, which count 56, the number of dissertation with PET was 319, with Planar was 302, with SPECT was 172, with radiopharmaceutical was 113, with guard and safety management 103, with BMD was 28, etc. was 86. The number of dissertation about oncology was 201, about scanner was 179, about cardiovascular and circulatory system was 102, about safe environment was 82, about musculoskeletal system was 76, about nervous nuclear medicine was 66, about quality assurance was 61, about genitourinary system was 56, about endocrine system was 49, about digestive system was 44, about Therapy, about industrial safety was 24, about molecular imaging was 15, infection and inflammation was 9, about respiratory system was 8 and etc. was 108. The mostly used keyword through 1999 to 2005 was PET and through 2006 to 2016 was PET/CT. Conclusion To encourage various dissertations to be submitted, Korea Society of Nuclear Medicine should analyze date about not only about dissertations that are already published, but also about various research materials. Moreover, Korea Society of Nuclear Medicine also have to provide technical support such as sharing big data from homepage and systematical support to its member to publish dissertation that has high impact factor. It is important each individual researcher to have continuing effort as well as each organization cooperation.

  • PDF