Cooling Analysis of Super Precision and Large Stage for OLED

  • Kim, Bo-Seon;Kim, Kug Weon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.4
    • /
    • pp.51-55
    • /
    • 2018
  • As the OLED industry develops, display equipment is becoming larger. As a result, the stage required for display equipment is getting bigger. This enlargement led to increase in OLED production and industrial development. However, due to the large scale of the stage, other problems due to overheating and overheating caused by heavy load on the linear motor, which is mainly used in the stage, must be solved. In this study, a linear motor equipped with a cooling channel is modeled and the three - dimensional heat conduction flow analysis for this model is simulated using Fluent to analyze the cooling efficiency and cooling efficiency according to the cooling water flow rate. As a result, the cooling channel was effective and the cooling effect and efficiency were the best when the flow rate was about 5 ~ 10 L./min. In addition, the cooling effect is increased when the flow rate is increased, but the efficiency is significantly lowered when the flow rate is more than the predetermined value.

The Diagnosis of Squirrel-cage Induction Motor Using Wavelet Analysis and Neural Network (웨이블릿 분석과 신경망을 이용한 농형 유도전동기 고장 진단)

  • Lee, Jae-Yong;Kang, Dae-Seong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.1
    • /
    • pp.75-81
    • /
    • 2008
  • The induction motor is given a great deal of weight on the industry generally. Therefore, the fault of the induction motor may cause the fault to effect another parts or another faults in the whole system as well as in itself. These are accompany with a lose of the reliability in the industrial system. Accordingly to prevent these situation, the scholars have studies the fault diagnosis of the induction motor. In this paper, we proposed the diagnosis system of the induction motor. The method of diagnosis in proposed system is extracted the feature of the current signal by the wavelet transform. These extracted feature is used the automatic discrimination system by the neural network. We experiment the automatic discrimination system using the three faults imitation that often generated in the induction motor. The proposed system have achieved high reliable result with a simple devices about the three faults.

  • PDF

Estimation of Motor Deterioration using Pulse Signal and Insulation Resistance Measurement Algorithm (펄스 신호 및 절연저항 측정 알고리즘을 이용한 전동기 열화 추정)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.5
    • /
    • pp.111-116
    • /
    • 2022
  • The causes of motor burnout include overload, phase loss, restraint, interlayer short circuit, winding ground fault, instantaneous overvoltage, and the rotor contacting the stator, leading to insulation breakdown, leading to breakdown or electrical accidents. Therefore, equipment failure causes not only loss due to cost required for equipment maintenance/repair, but also huge economic loss due to productivity decrease due to process stop because the process itself including the motor is stopped. The current level of technology for diagnosing motor failures uses vibration, heat, and power analysis methods, but there is a limit to analyzing the problems only after a considerable amount of time has passed according to the failure. Therefore, in this paper, a device and algorithm for measuring insulation resistance using DC AMP signal was applied to an industrial motor to solve this problem. And by following the insulation resistance state value, we propose a diagnosis of deterioration and failure of the motor that cannot be solved by the existing method.

Development of Automatic Remote Exposure Controller for Gamma Radiography (감마선투과검사 장치의 자동 원격조작기 개발)

  • Joo, Gwang-Tae;Shin, Jin-Seong;Kim, Dong-Eun;Song, Jung-Ho;Choo, Seung-Hwan;Chang, Hong-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.490-499
    • /
    • 2002
  • Recently, gamma radiographic equipments have been used about 1,000 sets manually and operated by about 2,500 persons in Korea. In order for a radiography to work effectively with avoiding any hazard of the high level radiation from the source, many field workers have expected developing a wireless automatic remote exposure controller. The KlTCO research team has developed an automatic remote exposure controller that can regulate the speed of $0.4{\sim}1.2m/s$ by BLDC motor of 24V 200W which has output of $54kgf{\cdot}cm$, suitable torque and safety factor for the work. And the developed automatic remote exposure controller can control rpm of motor, pigtail position by photo-sensor and exposure time by timer to RF sensor. Thus, the developed equipment is expected that the unit can be used in many practical applications with benefits in economical advantage to combine the use of both automatic and manual type because attachment is possible existent manual remote exposure controller, AC and DC combined use.

Application of medium-voltage drive to motor equipment of 800MW gas power plant. (800MW 가스발전소의 모터 설비에 고압 드라이브를 적용한 사례)

  • Kim, Kyoungsue;Oh, Hyunseok;Park, Jongje;Jeon, Jaehyun;Park, Cheolhyun
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.424-425
    • /
    • 2018
  • In the introduction, this paper introduces LS Industrial Systems' medium-voltage drive installed at Hyundai Green Power, an 800MW gas power plant. In the body, it explains the synchronous transfer technology and new speed search technology applied to Forced Draft(FD) Fan and Boiler Feed-water(BF) Pump, which are power generation facilities. Lastly, it shows the annual energy saving amount and operation status which are applied to each facility and proves that it is a successful application case.

  • PDF

Development of Speed Control System for SPMSM with Direct Torque Control (직접토크 제어에 의한 SPMSM 속도제어시스템 개발)

  • Kim, Dong-Hee;Lim, Tae-Hoon;Baik, Won-Sik;Kim, Min-Huei
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.66-74
    • /
    • 2005
  • This paper presents an implementation of digital servo speed control system of SPMSM(Surface-mounted Permanent Magnet Synchronous Motor) for industrial application with Direct Torque Control(DTC) using TMS320F2812 DSP. Although, the vector control scheme is adapted in many industrial servo system, but the DSP calculation ratio is increased by reference frame transformation and SVPWM of vector control. Therefore, this paper investigate the possibility of DTC scheme for industrial servo drive system instead of vector control scheme. DSP calculation ratio is compared between vector control and DTC algorithm in addition to the characteristic of speed control response. The suggested SPMSM control system shows the possibility of DTC scheme for industrial servo motor drive system instead of a vector control algorithm.

Robust speed control of DC motor using Expert Sliding mode controller (전문가 슬라이딩 모드 제어기를 이용한 직류전동기의 강인한 속도제어)

  • 지봉철;박왈서
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.89-93
    • /
    • 2000
  • Robust control for DC motor is needed according to the highest precision of industrial automation. However, when a motor control system has an effect of load disturbance, it is very difficult to guarantee the robustness of control system. Generally, it is known that sliding mode controller has robustness. But, after it is assumed that we known the disturbance uncertainty, sliding mode controller is designed. Thereafter, if we are not known th disturbance uncertainty then controller design is difficult. As a method solving this problem, in this paper, Expert sliding mode control method for motor control system is presented.The proposed controller can eliminate load disturbance effectively. The effectiveness of the control scheme is verified by simulation results.

  • PDF

A New Direct Torque Control Method of Induction Motor for Torque Ripple Reduction

  • Kim, Deok-Ki;Kim, Jong-Su;Kim, Sung-Hwan;Kim, Hyun-Soo;Kim, Won-Ouk;Yoon, Kyoung-Kuk;Oh, Sae-Gin
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.7
    • /
    • pp.1061-1067
    • /
    • 2008
  • Direct Torque Control[DTC] and Vector Control are the two schemes developed for high performance induction motor drives. DTC based induction motors are being increasingly used in various industrial applications. DTC offers fast torque response and better speed control with lesser hardware and processing costs as compared to vector controlled drives. However, conventional DTC suffers from high torque ripple, current harmonics and low performance during torque transients. In this paper a new Direct Torque Control[DTC] method of induction motor is presented. In comparison with the conventional DTC method, the PWM technique is applied to proposed control method. In this method, decoupling mechanism is not required and the torque, the flux magnitude are under control using PI controllers and generating the voltage command for inverter control. Therefore torque and speed ripple could be reduced in comparison with the conventional switching table DTC.

Speed Control of Three Phase Slotless PM BLDC Motor Using Single Sensor (Single Sensor를 이용한 3상 Slotless PM BLDC 전동기의 속도제어)

  • Lee S. J.;Yoon Y. H.;Woo M. S.;Won C. Y.;Choe Y. Y.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.33-37
    • /
    • 2004
  • Slotless Permanent magnet Brushless DC Motor(PM BLDC) with the characteristics of high speed and high power density has been more widely used in industrial and automatic machine. Generally, PM BLDC meter is necessary that the three Hall-ICs evenly be distributed around the stator circumference in case of the 3 phase motor. The Hall-ICs are set up in this motor to detect the main flux from the rotor. therefore the output signal from Hall-ICs is used to drive a power transistor to control the stator winding current. However, instead of using three Hall-ICs, if only we used one Hall-IC, we estimate information of the others phase in sequence through a revolving rotor. This paper identified the characteristics and performance by using one Hall-IC for the 3 phase PM BLDC whose six stator and two rotor designed.

  • PDF

Plug-in BLDC Control System using DC-link Communication (DC 전력선 통신을 이용한 Plug-in형 BLDC 구동 시스템)

  • Yu, Tao;Song, Doo-Young;Choi, Joon-Ho;Moon, Chae-Joo;Cho, Su-Eog;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.592-594
    • /
    • 2008
  • The powers used in the robot drive motor system are mostly DC sources such as batteries. Even AC powers in some systems are generated from DC sources by the inverter. It is can be forecasted that the DC-link communications will be widely used invarious industrial application. In this paper a novel BLDC motor drive system by using DC-link communications is proposed. The characteristic of this system is the communication only needs 2 DC lines. There are not additional lines to translate the reference signals and the reliability of the system is enhanced especially in some badly circumstance. The number of lines can be least when applied in the multi motor control system and the slip ring design can be simplified when applied as rotation machine. The reasonableness of proposed motor system is clarified by the PSIM simulation and the hardware prototype.